CS Paper Radar

Video-Time Priors for EEG-fNIRS Emotion Regression on Familiar Videos

Minghao Kong, Ying Gao, Jiurun Chen, Muyao Chen, Zheng Ge, Jianxin Wu, Rongjie Wang

cs.AI cs.CVcs.MM ·submitted 2026-10-02 17:14 UTC · v2

Abstract

Do viewer-specific physiological signals improve continuous emotion regression beyond the stimulus-driven response shared across viewers? We examine this question by predicting emotion ratings for new viewers watching videos that also appear in the training set. As a stimulus-only baseline, we define a video-time prior:the smoothed median of training labels for each video at each second. We then combine this prior, using a fixed fusion weight, with a graph-based model of electroencephalography (EEG) and functional near-infrared spectroscopy (fNIRS) signals. On MER-PS 2026, five-fold cross-validation grouped by participant over 24 participants yields a mean absolute error (MAE) of 29.01 for fusion, compared with 29.06 for the prior alone. On an external cohort of four participants excluded from training, the corresponding MAEs are 27.72 and 28.04. In this cohort, most of the MAE reduction relative to a global-constant baseline comes from the prior, that is, from video identity and playback time alone.Fusion lowers MAE for three of the four held-out participants and for nine of the fifteen videos. The added value of physiological signals is therefore small and varies across participants and videos. Because the model uses physiological signals recorded after each prediction time, it supports only offline prediction. Generalization to unseen videos remains untested.

Closest papers

Nearest neighbours by meaning across the whole index.

Modeling Shared and Individual Structure for Cross-Subject Continuous Affect Regression from EEG-fNIRS

cs.AI ·2026-10-02 ·Xuan Wang, Bing Wang, Shuai Chang, Hao Yuan, Xinbo Qi +1 more
similarity 0.69
Abstract

Continuous, second-by-second valence-arousal estimation from physiological signals is typically studied in a subject-dependent setting, where the model sees labeled data from the same person it is later evaluated on. We study the harder zero-shot cross-subject variant on a synchronized EEG-fNIRS dataset: predict raw-scale ([1, 255]) valence and arousal trajectories for subjects whose labels the model never observes, given only their unlabeled EEG/fNIRS recordings while watching the same video stimuli as a disjoint set of training subjects. We decompose the affect trajectory into a structure shared across subjects who watch the same stimuli and an individual structure estimated for each test subject from a label-free EEG marker (alpha-band cross-channel synchrony), which rescales the shared trajectory around the scale midpoint. We validate the per-subject calibration mechanism on four independent axes: leave-one-subject-out correlation between the marker and each subject's true optimal gain, a functional-form comparison against non-linear alternatives, a repeated leave-4-out component ablation isolating each part of the pipeline's contribution, and a ceiling analysis bounding the remaining headroom for per-subject scaling. On held-out subjects, the model reaches an overall MAE of 25.96 / 22.80 across two evaluation batches (valence 21.94 / 19.6, arousal 29.98 / 26.0), well below EEGNet and ASAC-Net baselines reported for the same subject-independent split (raw scale score 60.6 and 55.0 respectively). We further report a systematic negative-result search across model architectures, feature representations, and prediction targets that found no signal able to improve on the single alpha-synchrony marker.

0.27

Towards fNIRS foundation models: A curated corpus of 67 public datasets with channel positions in MNI space

cs.HC ·2026-10-29 ·Santiago Posso-Murillo
datasetcode/data similarity 0.65
Abstract

Brain foundation models have transformed medical artificial intelligence and computational neuroscience by reducing the reliance on task-specific data through large-scale pretraining. While they have been successful with non-invasive neuroimaging data, their adoption in functional near-infrared spectroscopy (fNIRS) has lagged due to the limited size and heterogeneity of public datasets, which are collected under varying protocols, devices, and sensor configurations. In addition, no single fNIRS dataset is comparable in size to the largest datasets in functional magnetic resonance imaging (fMRI), electroencephalography (EEG), or magnetoencephalography (MEG). The fNIRS datasets are also spread across different platforms and often have insufficient information, or lack the protocols that would make them easier to use. Given the advances in EEG foundation models that enable flexible modeling across diverse EEG montages, we curated 1,955 hours of fNIRS data from 67 public datasets spanning 2,798 participants, representing the largest fNIRS curation effort to date. The curated data include oxygenated (HbO) and deoxygenated (HbR) hemoglobin signals along with the three-dimensional position of every channel in the standard space of the Montreal Neurological Institute (MNI), which makes positions comparable across datasets. We release dataloaders that handle each dataset automatically, along with the minimal preprocessing pipeline used to prepare the data, at https://github.com/sposso/fnirs-datasets. This work aims to facilitate the future development of foundation models for fNIRS.

0.19

fNIRSAtlas: A Large-Scale Benchmark for Functional Near-Infrared Spectroscopy Classification

cs.LG ·2026-11-06 ·Kalle Mäkelä, Tuukka Ruotsalo
top venuebenchmarkcode/data similarity 0.63
Abstract · Accepted to NeurIPS 2026 (Evaluations & Datasets Track)

Functional near-infrared spectroscopy (fNIRS) is a promising modality for brain-computer interfaces and cognitive state decoding, but progress in machine learning for fNIRS has been limited by small, isolated datasets and inconsistent evaluation protocols. We introduce fNIRSAtlas, the largest open benchmark for fNIRS classification to date, comprising 23 classification tasks from 19 public data collections, spanning diverse experimental paradigms, including motor execution, motor imagery, mental arithmetic, working memory, and emotion recognition. fNIRSAtlas provides a fully automated pipeline from raw data to evaluation and defines standardized benchmark tasks for both cross-subject and within-subject classification, ensuring reproducible comparison of methods. We evaluate a variety of baseline models from fNIRS and related neuroimaging and time-series machine learning literature on the benchmark. Our results demonstrate that performance varies substantially across tasks and that methods validated on limited data -- especially deep learning approaches -- often fail to generalize beyond their original evaluation. fNIRSAtlas serves as an extensible, open, and reproducible benchmark to support more robust and cumulative progress in machine learning for fNIRS data. Our code and data can be found at https://fnirsatlas.github.io.

0.32

MUPA$^{2}$E: Multimodal Unified Perception with Asymmetric Attention for Emotion Assessment

cs.AI ·2026-08-17 ·Stefanos Gkikas, Eric Nichols, Christian Arzate Cruz, Randy Gomez
similarity 0.61
Abstract

Automatic emotion assessment can benefit from combining neural and behavioral signals, but many multimodal approaches rely on separate, modality-specific feature-extraction pipelines before fusion. This paper presents MUPA\textsuperscript{2}E, a unified perception framework that processes facial video and electroencephalography (EEG) through a single shared asymmetric-attention backbone. Facial video is represented through axis-folded frame tokens, while EEG is processed either as a raw multichannel waveform or projected into the spatial domain for multimodal fusion. The framework is evaluated on the DMER dataset under a stratified subject-independent protocol, comparing unimodal video, unimodal EEG, and fused video--EEG configurations with per-channel and merged EEG projections. Using the original recordings, with shorter trials zero-padded to match the longest duration, merged fusion at stride~$30$ achieves the highest validation performance and a test accuracy of $70.07\%$. Further analysis revealed that recording duration is unevenly distributed across the affective classes, making the padding pattern a potential classification cue. Controlling for this factor by cropping all recordings to a common duration of $20$ seconds yielded a test accuracy of $62.71\%$, providing a stricter duration-controlled assessment of the framework in which differences in recording length are removed as a potential classification cue. These findings demonstrate the feasibility of processing structurally different neural and visual signals within a compact unified architecture while highlighting the importance of controlling duration-related cues in affective datasets.

0.24

How Much of Cross-Subject EEG Emotion Recognition Is Stimulus Memorization?

eess.SP ·2026-10-20 ·Haiyan Xu, Konstantinos N. Plataniotis
similarity 0.61
Abstract · 5 pages, 1 figure, 2 tables

Cross-subject EEG emotion recognition now reports accuracies above 90% on stimulus-defined benchmarks such as SEED, and the field has examined several ways in which such numbers can be inflated, attributing inflation to subject identity, to data partitioning, and to repeated stimulus presentation. We observe that one variable has been left out. On these datasets the emotion label is assigned to the video at design time, so any encoder that recovers which video was shown obtains the label for free. We adapt three representation-level shortcut diagnostics to a cohort of published contrastive cross-subject encoders, and find that stimulus identity is linearly recoverable at six to fifteen times chance. We then measure its impact on the reported accuracy by holding out subjects and stimuli jointly, and find that each released classifier loses two to forty-four points once the test videos are unseen, so a headline obtained under subject hold-out alone is not a measure of cross-subject emotion decoding.

0.16

Controlled Evaluation of EEG Foundation Models: Random Initialisation, Band-Power and Validation-Selected Probes

cs.LG cs.AI ·2026-10-23 ·Mingyu Jeon, Suwan Cho, Jae Young Suh
similarity 0.60
Abstract

EEG foundation models report downstream gains, yet their protocols seldom include three controls. These are the same encoder untrained, spectral features fitted on the same data, and a layer picked without looking at test scores. We therefore evaluate five publicly released EEG foundation models and an in-house JEPA-style model under one protocol with all three controls and several seeds, on five benchmarks and four added task families. The controls change the reading in three ways. First, picking the probed layer by its test score raises the layer-wise peak by an average of +0.034 and reverses the peak-versus-output gap in 9 of 36 cells. Second, with the layer picked on validation, random initialisation matches or beats pretraining for half of the models on sleep and emotion, and no model beats a five-band log-power baseline on emotion or motor imagery. Third, after full fine-tuning only 5 of 30 pairs gain beyond twice their seed spread, and the one clear loss of -0.290 AUROC persists under matched learning rates. From these results we draw four reporting practices, and we release every cell for re-analysis.

0.06

iMINDBench: iEEG Multi-Institution Neural Decoding Benchmark

cs.LG ·2026-09-16 ·Geeling Chau, Saba Hashemi, Yonghyeon Gwon, Eshani Patel, Jan DeWitt +7 more
benchmark similarity 0.58
Abstract · 26 pages, 13 figures

Intracranial electroencephalography (iEEG) is widely used to record electrical activity directly from electrodes inside the human brain, making it an attractive modality for neural decoding. However, progress in iEEG decoding, especially toward general-purpose foundation models, remains difficult to measure reliably: datasets are task- or institution-specific, limiting evidence of generalization across tasks and recording environments, and preprocessing choices can strongly influence performance, making model improvements difficult to distinguish from preprocessing gains. Thus, we introduce iMINDBench, an iEEG Multi-Institution Neural Decoding Benchmark that evaluates models on a shared suite of fifteen decoding tasks across three naturalistic movie-watching datasets. The benchmark additionally defines standardized preprocessing tracks and fixed evaluation splits to support consistent model comparisons. Using iMINDBench, we find that the evaluated pretrained systems generally outperform baselines within their respective preprocessing tracks, while strong spectral baselines remain competitive across institutional datasets. In our scaling study, adding up to 25 times more supervised data from other subjects or institutions yields only small or task-dependent gains over within-session training. Together, these findings highlight the need for iEEG models that improve on strong preprocessing baselines and make more effective use of data across subjects and institutions. Project website: https://imindbench.github.io/

0.28

Occlusion-Robust Multimodal Emotion Recognition in VR via Fusion of Facial Images and EMG

cs.CV cs.HC ·2026-09-03 ·Birgit Nierula, Karam Tomotaki-Dawoud, Mert Akguel, Mustafa Tevfik Lafci, David Przewozny +3 more
publisheddataset similarity 0.58
Abstract · Joint Proceedings of the ACM Intelligent User Interfaces (IUI) Workshops 2026

Head-mounted displays (HMDs) fundamentally limit emotion recognition in virtual reality (VR): by occluding the upper face, they render conventional image-based facial expression analysis incomplete, particularly for applications requiring real-time affective assessment. We address this challenge by fusing lower-face video with facial electromyography (EMG) from the occluded upper face to classify seven emotional categories (six basic emotions plus neutral). We introduce a synchronized multimodal dataset from 20 participants, pairing lower-face video with seven-channel upper-face EMG elicited by validated emotion stimuli. Under subject-independent test, our proposed late-fusion architecture merging convolutional visual embeddings with RBF-kernel EMG representations achieves 51% macro-F1, outperforming both image-only (41%) and EMG-only (43%) baselines. These results demonstrate that upper-face EMG provides robust complementary information under HMD-induced visual occlusion and establish a foundation for multimodal emotion recognition in naturalistic VR environments. This approach facilitates affect-adaptive applications, including communication training and therapeutic interventions. The dataset will be shared upon request under an ethical-use agreement.

0.49