CS Paper Radar

When Layer Selection Misleads Speech Depression Detection

Paula A. Perez-Toro, David Gimeno-Gómez, Daniel Rückert, Andreas Maier

eess.AS ·submitted 2026-10-05 14:59 UTC · v1
position

Abstract

Pretrained speech representations are increasingly used for depression detection, but selecting the best encoder layer on the same data used for evaluation biases reported performance. On DAIC-WOZ, with repeated nested cross-validation across five deep encoder families, naive best-of-25-layer probing inflates AUC by up to $0.09$. On shuffled labels over the \emph{real} latent representations, naive best-of-25 still reaches AUC $0.59$ versus $0.50$ under nested selection, and this bias grows with the number of probed layers and with smaller samples, isolating selection, not signal, as the cause. The effect replicates on a second clinical corpus and language (Androids, Italian). Under leakage-free selection, a fair comparison across representation families identifies a compact, task-aligned affect--prosody model as competitive with substantially more complex SSL, deep-learning, audio-LLM, and codec-based approaches, while using $\sim\!10^{3}\times$ fewer trainable downstream parameters. Extending the analysis to individual PHQ-8 symptoms shows that the same selection bias persists at this finer-grained level. We argue nested model-selection protocols should be standard when probing encoder layer representations on small clinical speech datasets.

Comment
Submitted to ICASSP 2027

Closest papers

Nearest neighbours by meaning across the whole index.

A corpus-only AUC diagnostic for pooled speech-based depression detection

eess.AS ·2026-10-22 ·Cezary Polak, Milosz Dudek, Daria Hemmerling
similarity 0.71
Abstract

When clinical speech corpora are pooled for evaluation, corpus membership can itself become predictive if class prevalences differ across sources. We derive the AUC of an oracle predictor that uses only corpus identity and empirical prevalence, a diagnostic computable directly from corpus composition. Across five depression corpora in three languages (590 speakers), the corpus-only AUC is 0.697, and corpus identity is predicted from six acoustic and self-supervised representations with 97.5-99.8% accuracy. Permuting depression labels within each corpus removes label structure while preserving prevalences; the residual pooled-minus-LOCO discrepancy then increases across three nested configurations in the same order as the diagnostic. Pooled 5-fold cross-validation also outscores corpus-held-out evaluation across all six representations. Prevalence equalisation substantially reduces the discrepancy for eGeMAPS and WavLM-Base, whereas a sample-size-matched control does not. Corpus-specific base rates therefore create a measurable shortcut opportunity in pooled clinical-speech evaluation, motivating corpus-aware diagnostics alongside pooled performance.

0.18

Where Does the Sound Go? Tracing Acoustic Information Loss in Audio-Conditioned LLMs

cs.SD cs.AI ·2026-09-05 ·Song-ha Jo, Sehyun Lee, Soyoon Kim, Jaesik Choi, Sanghyuk Choi
top venue similarity 0.68
Abstract · EMNLP2026 Findings

Audio-conditioned language models often underuse acoustic cues such as prosody, emotion, and non-speech sounds, raising the question of whether ASR-supervised frontends discard this information before it reaches the LM. We test whether the frontend is responsible by comparing Whisper-Tiny and Whisper-Small with EnCodec, DAC-VAE, and WavTokenizer in a shared Qwen3.5-4B audio-LM pipeline on ASR, emotion recognition, and sound captioning. Encoder replacement alone does not resolve this underuse: Whisper variants remain strongest overall, including on emotion and environmental sound captioning. To localize the failure, we trace task-relevant information through the encoder, projector, LM layers, and LM head. Linear probes and geometric analyses show that discriminative acoustic structure remains recoverable at the final LM layer, even when MCQA accuracy trails probe accuracy by up to 83 points. Because the answer format and decoding procedure are controlled, this task-dependent gap points to content-specific readout failure rather than generic format bias. LogitLens analyses and a targeted LM head intervention support the conclusion that acoustic underuse is not explained solely by encoder-side information loss and that readout alignment can be a dominant bottleneck.

0.57

DiaWhisper-DPO: Role-Attributed Transcription of Clinical Interviews via Failure-Mined Preference Optimization

cs.CL ·2026-09-15 ·Weiming Li, Ana Catarina Fidalgo Barata, Miguel Constante, João Miguel Sanches
similarity 0.67
Abstract · 5 pages, 2 figures. Submitted to ICASSP 2027

Automated depression screening from clinical interviews requires attribution of utterances to the clinician or patient. We evaluate two datasets: DAIC-WOZ, where participant-only recordings require re-synthesizing both sides for controlled two-party evaluation, and PDCH-HAMD, comprising voice-converted real Chinese interviews for cross-lingual validation. Cascaded systems combine speaker diarization with role-assignment heuristics, so errors can propagate across stages. We propose an end-to-end model, which we named DiaWhisper, that fine-tunes Whisper-large-v3 with LoRA and an auxiliary frame-level role head for transcription and attribution, together with DiaWhisper-DPO, a failure-mined refinement that uses genuine decoding failures as DPO rejected completions without human preference annotation. On 29 DAIC-WOZ test sessions, DiaWhisper-DPO achieves 0.973 role accuracy and 0.119 DER, 72% below the strongest cascaded baseline, and reduces seed variation from σ = .205 to .002. Retrained on PDCH-HAMD, it achieves 0.757 role accuracy and improves all 78 session-seed pairs.

0.30

SIGMA: speaker-isolated, symptom-structured multimodal estimation of depression severity from clinical interviews

cs.SD cs.AIcs.LG ·2026-11-17 ·Zhuoyuan Tang, Tao Wang, Kai Yang, Li Yuan, Yuezhou Zhang +6 more
similarity 0.67
Abstract

Clinical interviews are central to depression assessment but time-consuming and rater-dependent. Automated severity estimation offers scalable screening, yet existing methods often retain interviewer speech (confounding participant cues), fuse modalities late (losing fine-grained cross-modal dynamics), or score symptoms independently (ignoring inter-symptom correlations). We present SIGMA, a speaker-aware, symptom-structured framework for depression-severity estimation from semi-clinical interviews. SIGMA uses speaker diarization to restrict input to participant speech, cross-attention so that text, audio and video condition one another during encoding, and a graded-response head that predicts the eight questionnaire items jointly through a shared latent severity trait with item-specific ordered thresholds. On the Extended Distress Analysis Interview Corpus, SIGMA achieves state-of-the-art performance (CCC 0.762, RMSE 4.13, MAE 3.30 over five seeds). Ablations confirm that isolating participant speech and joint, structured symptom prediction each substantially improve concordance and estimation accuracy.

0.18

Disentangling Depression from Cognitive Decline in Elderly Speech Using Concurrent Clinical Assessments

eess.AS cs.AIcs.CLcs.SD ·2026-10-15 ·Woori Jeon, Seunghee Ha, Sang-Kyu Lee, Ji Hye Yoon, Tae-Jin Yoon +3 more
top venue similarity 0.64
Abstract · 6 pages, 5 tables, accepted to Interspeech 2026

Detecting depression from speech in elderly patients with mild cognitive impairment (MCI) is complicated by overlapping acoustic effects of cognitive decline. Without disentangling these, classifiers risk learning cognitive rather than depression-specific patterns. We present a Korean elderly speech corpus of 89 MCI speakers collected over three years with concurrent depression (SGDS) and cognitive (MMSE) assessments. Both linear mixed-effects models and partial correlations identify the same pattern: of seven feature groups, only formant features are associated with depression after controlling for cognitive function, while widely used F0 features carry no signal. The F1+F2 subset achieves UAR 0.760 with just 12 features, outperforming both the full eGeMAPS baseline and self-supervised representations. These findings show that concurrent clinical assessments can identify interpretable, depression-specific acoustic markers in populations where cognitive and affective symptoms co-occur.

0.29

Do Audio LLMs HEAR Pain? Tracing Acoustic Evidence from Speech to Language Reasoning

cs.CL cs.AIcs.SD ·2026-10-28 ·Wenqi Li, Xiangjue Dong, Sulaiman Vesal
similarity 0.64
Abstract · 26 pages, 9 figures

Large audio language models (LALMs) can process speech directly, but it remains unclear how well they use the non-lexical acoustic information that speech carries. We study this question through pain, using TAME-Pain, which contains pain-neutral Harvard sentences and spoken pain ratings recorded at different self-reported pain levels. We introduce HEAR, a four-stage diagnostic framework that traces pain-related information from the speech signal to the model's prediction, and apply it to seven closed-source and open-weight LALMs. On the Harvard sentences, where pain can only be inferred from the voice, all models perform at chance level, and same-speaker references or few-shot examples improve balanced accuracy by no more than six points. On the spoken ratings, the same models reach 87.5-99.7% balanced accuracy. Layer-wise probing of open-weight LALMs shows that pain can be decoded from early audio representations (74.1% balanced accuracy for binary prediction and 45.0% for three-class severity), but that this information, along with most pain-associated acoustic cues, decreases in deeper layers. In an acoustic perception test, weaker models cannot distinguish even large changes in these cues, whereas stronger models can but still fail to infer pain. Finally, we recover pain-related acoustic cues and directly reinject them as structured text into the prompt, which improves pairwise pain prediction by up to 32 points. These results indicate that current LALMs encode paralinguistic information in early layers that is largely unavailable when the model produces its answer.

0.18

Benchmarking Open-Source Speech Emotion Recognition in Naturalistic Mandarin Spine Clinic Consultations: A Pilot Validation Study

cs.SD cs.CY ·2026-08-24 ·Tsz Yuet Yeung, Zonglin He, Dong Chen, Huili Peng, Huiren Tao +1 more
code/data similarity 0.64
Abstract

Speech emotion recognition (SER) may enable passive affect monitoring in clinical encounters, but most systems are validated on acted laboratory speech rather than naturalistic Mandarin outpatient consultations. We benchmarked three open-source SER models (emotion2vec+, SenseVoice, FunASR) against a researcher-consensus reference in naturalistic spine-clinic speech, assessing minority-state detection under class imbalance. In a retrospective analysis of prospectively collected single-center recordings, audio was loudness-normalized and only conversations among patients, family members, and clinicians were retained. Sixty-five utterances (5-50 s; one per participant; 31 patients, 34 family members) were labeled by six calibrated annotators into six categories (Happy, Sad, Fear, Anger, Neutral, Surprised). Consensus used majority vote with Fleiss kappa filtering and clinician adjudication for low-agreement segments. Metrics included unweighted accuracy (UA), macro-average per-class accuracy, class- and sample-level weighted accuracy (WA), and F1 with bootstrap 95% CIs. Labels were imbalanced (Neutral 58.5%); median Fleiss kappa was 0.230 (IQR 0.134-0.519). SenseVoice and FunASR achieved UA 61.5% (95% CI 49.2-73.8%), macro-average per-class accuracy 87.2%, class-level WA 92.5%, and sample-level WA 24.6%. emotion2vec+ yielded UA 55.4% (95% CI 42.5-67.7%) and macro-average per-class accuracy 85.1%, with class-level WA 90.6% and sample-level WA 24.2%. Despite high inter-model agreement (90.8%), all models had near-zero recall for Sad, Fear, Anger, and Surprised. In this pilot, majority-class accuracy was misleading: SER poorly detected minority emotions against a noisy naturalistic reference. Clinical deployment readiness cannot be inferred from acted-corpus benchmarks without domain adaptation, multimodal modeling, stronger reference standards, and outcome validation.

0.32

VocalAffectBench: Evaluating Vocal Emotion Recognition in AI Audio Models

cs.CL cs.SD ·2026-08-28 ·Luc Debaupte, Tyler Baumgartner, Brandon Tai, Candice Fan, Bill Wang +1 more
benchmarkcode/data similarity 0.64
Abstract · 6 pages, 6 tables. Benchmark, baseline predictions, and aggregate results are publicly available

Voice products increasingly need affective cues that are present in speech but absent from transcripts. We introduce VocalAffectBench, a public, test-only benchmark for evaluating whether AI audio models can identify expressed vocal emotion from raw audio. The benchmark contains 273 human-recorded English WAV clips from 51 speaker accounts totaling 1.95 hours across seven labels: angry, disgusted, fearful, happy, neutral, sad, and surprised, with 39 clips per class. All baselines are evaluated from audio alone, without transcripts or contextual metadata. Across six released baselines, average accuracy is 35.5%. The strongest baseline, gemini_3_5_flash, reaches 46.5% on the seven-way task, above the 14.3% random baseline but far from robust emotion recognition. A secondary valence-bucket analysis maps labels into positive, neutral, and negative classes, excluding surprised because its valence is ambiguous. Aggregate accuracy under this coarser view is 50.9%. Performance is highly uneven across classes. By recall, neutral is identified most reliably at 75.6% averaged across baselines, while surprised and fearful reach only 10.7% and 15.4%, respectively. These results show that the evaluated baselines can extract some affective signal from speech, but discrete expressed-emotion recognition remains fragile, especially for non-neutral emotions that are often most important in voice agent workflows.

0.59