CS Paper Radar

Deep Learning for Sleep Heart Rate Estimation from Accelerometers: Toward Population-Scale Cardiac Insight Without Optical Sensors

Tanbin Islam Rohan, Pranjol Sen Gupta, Tanusree Debi, Nazmus Sakib

cs.LG cs.AI ·submitted 2026-10-05 17:56 UTC · v1

Abstract

Large longitudinal cohorts often contain wrist accelerometry without optical heart-rate sensing, motivating recovery of cardiac information from motion signals already collected during sleep. We present SeqSmoother, a transformer-based temporal corrector for sleep heart rate (HR) estimation from wrist accelerometry. SeqSmoother combines spectral descriptors with an intermediate Nightbeat-derived frequency anchor and a physics-motivated sub-harmonic feature designed to identify harmonic frequency lock-on. All inference-time features are derived from wrist accelerometry, while ECG is used only to construct reference HR labels and training-label quality weights. We evaluate SeqSmoother using 13 participant-disjoint held-out folds and compare it with the official Nightbeat implementation under a matched 60-s window and 15-s step protocol. Across all out-of-fold predictions, SeqSmoother achieved a participant-macro MAE of 1.60 bpm. On Nightbeat-retained matched intervals, Nightbeat achieved lower absolute error than SeqSmoother (0.615 versus 1.091 bpm), while SeqSmoother provided estimates over a larger portion of the eligible recording; Nightbeat produced final estimates for 72.85% of the SeqSmoother-eligible out-of-fold grid. Separately, the proposed sub-harmonic ratio achieved an AUROC of 0.972 for identifying reference-defined harmonic lock-on candidates. These findings reveal an accuracy-availability trade-off between learned temporal modeling and quality-gated signal processing while providing empirical support for a physics-informed approach to identifying frequency-tracking failures in accelerometer-based sleep HR estimation.

Comment
8 pages, submitted in BHI 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Non-invasive Seizure Detection Using Wearable Wrist-worn Accelerometry and Deep Learning

cs.LG cs.AI ·2026-10-05 ·Nilushika Udayangani Hewa Dehigahawattage, Kishor Nandakishor, Marimuthu Palaniswami
similarity 0.65
Abstract · Under Review

Seizure monitoring and detection are crucial for reducing the morbidity and mortality associated with seizures. Current epilepsy care, often involving expensive video-electroencephalography (VEEG) monitoring, requires specialized expertise and is limited to in-hospital settings, and intrusive in nature. Seizure diaries, on the other hand, suffer from unreliability due to under-reporting, leading to incorrect therapeutic decisions. Wearable non-invasive seizure detection may offer a more tolerable and feasible solution for long-term ambulatory monitoring. This study explores a wearable remote monitoring system utilizing a single wrist-worn accelerometer device and capable of detecting multiple types of seizures, including shorter duration events. We enrolled 79 patients under video-electroencephalography monitoring to wear accelerometer devices and collect data. Concurrent VEEG recordings were reviewed by board-certified epileptologists to produce annotations, including seizure onset, offset, and seizure type. Using this data, we constructed a deep neural network based on the time-series ResNet architecture, which could discriminate among seizure and non-seizure events. Our proposed approach achieved a seizure detection sensitivity of 95.65% and an overall false alarm rate of 0.15/24 hours during the evaluation, which spanned 5576 hours of total recording. Additionally, it resulted in an area under the receiver operating characteristic curve (AUC-ROC) of 0.98 and an area under the precision-re call curve (AUC-PRC) of 0.67 when averaged over 20 patients who experienced 46 convulsive seizures. These promising results suggest that the proposed seizure detection system can be effectively used for long-term ambulatory seizure monitoring. Future steps include validating our findings in larger datasets and assessing the utility of detection for additional seizure types.

0.25

Calibration-Free Cuffless Blood Pressure Estimation Using Multimodal ECG-PPG Fusion on a Google Pixel Watch

cs.HC ·2026-08-26 ·Jathushan Kaetheeswaran, Boyi Ma, Ali Abedi, Shehroz S. Khan, Milad Lankarany
hot direction similarity 0.64
Abstract

Inadequate blood pressure (BP) monitoring and management outside of clinical settings can worsen major cardiovascular risk factors such as hypertension. While cuff-based devices are commonly used for at-home monitoring, these devices can be inconvenient for daily use due to their sensitivity to body positions, upper-arm constrictions, and limited portability. A promising alternative is emerging in the form of consumer-grade smartwatches, where physiological signals related to cardiac activity can be used to estimate BP non-invasively and continuously across daily living conditions. In this work, we use data collected from a Google Pixel Watch in 40 participants to develop and compare several algorithm approaches for BP estimation. We found that our proposed deep learning model achieved the strongest overall performance, and that fusing smartwatch signals with demographic information improved model generalizability to unseen individuals. However, we also identified that model accuracy was not consistent across participant subgroups, with obese individuals yielding higher estimation errors than others. This study highlights the feasibility of consumer-grade smartwatches as accessible platforms for deploying robust BP estimation algorithms, though clinical reliability will require larger, more diverse populations and additional sensing modalities.

0.22

MoWaveQFormer: A Motion-Conditioned Quality-Gated Transformer for Smartphone-Based PPG Heart Rate Estimation

eess.SP ·2026-09-14 ·Swandip Singha, Rifat Bin Reza, Saifur Rahman Sabuj
similarity 0.64
Abstract · Submitted to arXiv. 8 pages, 5 figures

Photoplethysmography (PPG)-based heart-rate (HR) estimation on smartphones remains unreliable in free-living conditions because motion artifacts vary in spectral structure across activities, and benchmarks such as BUT PPG v2.0 label signal quality only as binary good or bad, discarding partially usable data. This study develops an HR estimation architecture that explicitly conditions motion type and signal quality rather than treating both uniformly. We propose MoWaveQFormer, a three-stage architecture trained under ECG supervision. Stage 1 assigns each window a discrete motion group based on accelerometer-derived spectral energy, without trainable parameters. Stage 2 uses this index to select one of the three learnable FIR filter banks for motion-specific spectral shaping of the PPG signal. Stage 3 embeds the resulting sub-bands into patch tokens, re-weights them via a differentiable soft gate derived from the quality label, and encodes them with a Transformer whose pooled output is regressed to HR, trained jointly with an ECG-supervised loss and a pulse-transit-time consistency term. In a subject-independent split of BUT PPG v2.0 (3,888 recordings, 50 subjects), MoWaveQFormer achieved a mean absolute error of 7.85 bpm, the lowest among five methods, with significant improvements over three baselines (Wilcoxon test, p<0.05). Ablation and Bland-Altman analyses characterize each component's contribution. With 816,445 parameters and sub-3-ms latency, MoWaveQFormer suits real-time deployment, pending validation on smartphone hardware. Replacing motion-agnostic filtering and binary quality discarding with differentiable conditioned processing offers a compact pathway to more reliable free-living PPG-based cardiovascular monitoring.

0.18

PPG-Bench: A Unified Benchmark for PPG Foundation Models

cs.LG ·2026-10-09 ·Arvasu Kulkarni, Mahir Jain, Aditya Ray Mishra, Sandeep Singh, Siddharth Panwar
benchmarkcode/data similarity 0.64
Abstract

Photoplethysmography (PPG) is increasingly recorded by wearable and clinical devices at enormous scale, and a growing number of PPG foundation models (FMs) have been developed to compute reusable representations for various downstream tasks. These models are difficult to compare: different evaluations use different datasets, task definitions, preprocessing, downstream heads, hyperparameter tuning, and baselines. We present PPG-Bench, a unifying open-source benchmark evaluating five public PPG FMs across nine open-access datasets and 26 tasks spanning cardiovascular state estimation, activity, sleep, screening, and identification. We evaluate models under four downstream regimes of increasing adaptability (linear probing, random forests, frozen MLP probes, and end-to-end finetuning), with model-specific hyperparameter optimization and subject-disjoint cross-validation. We also evaluate against three controls: random/constant baseline, a deterministic pulse-rate-variability (PRV) feature set, and a generic time-series FM (MOMENT). Across all 68 task-regime combinations, 35.3% show no meaningful FM advantage over the random/constant baseline, and in 83.8% no PPG-specific FM outperforms both PRV and MOMENT. We also find that added downstream head capacity generally improves performance, but can cause significant degradation if the model is performing at chance/constant level. Current PPG FMs therefore cannot yet claim to provide generalised and transferrable representations of PPG signals, and future evaluation in this field should include checks against simple, non-learned controls. Code for the benchmark and instructions to evaluate more models can be found here - https://github.com/mannas-ai/ppg-bench.

0.31

Characterizing the Performance Gap in Human Activity Recognition for Older Adults

cs.HC cs.LG ·2026-10-02 ·Hossein Khayami, Sungjin Hwang, Eshed Ohn-Bar, David E. Conroy, Amanda Lazar +2 more
publishedbenchmark similarity 0.63
Abstract · 8 pages, 6 figures, to be published in Proceedings of the 2026 ACM International Symposium on Wearable Computers (ISWC '26)

Human activity recognition (HAR) from wrist-worn accelerometers is increasingly used for health and behavioral tracking. Yet, most wearable HAR models are developed and evaluated on datasets dominated by younger adults, leaving it unclear whether benchmark progress generalizes across age groups. In this work, we leverage MyMove, our carefully annotated, free-living older-adult HAR dataset (mean age 71), to evaluate deep-learning architectures and training regimes under both leave-one-subject-out and cross-dataset transfer. We find that improvements on younger-adult benchmarks fail to transfer equally to data collected from older adults, resulting in a persistent and often widening performance gap. However, richer representations, particularly frozen self-supervised features pretrained on the age-diverse UK Biobank dataset, substantially improve performance on data from older adults and consistently narrow the performance gap, at modest cost to younger-adult performance, though disparities remain. These findings suggest that benchmark gains and architectural scaling alone provide an incomplete picture of progress in wearable HAR, and broader advances may require representations that better capture population diversity, alongside personalized adaptation to individual movement patterns and routines.

0.21

Interaction-Gated Time-Frequency Learning for Parameter-Efficient PPG-Based Heart Rate Estimation

cs.LG cs.AIeess.SP ·2026-10-20 ·Anh Khoi Pham, Phat Lam, Thien Truong Nguyen Ly, Lam Pham
benchmark similarity 0.63
Abstract · Conference preprint, accepted at SoICT 2026

Photoplethysmography (PPG) enables low-cost and non-invasive heart rate (HR) monitoring but remains sensitive to waveform distortion, physiological variability, and measurement interference. Temporal waveform characteristics and frequency-domain periodicity provide complementary information for HR estimation; however, effectively exploring and integrating these representations within a compact model remains challenging. This paper proposes TF-IG, a parameter-efficient interaction-gated time-frequency learning framework for PPG-based HR estimation. TF-IG employs a dual-branch architecture in which a temporal branch captures pulse morphology via dilated depthwise-separable convolutions, while a frequency branch extracts cardiac periodicity information from bounded log-spectrogram representations. To combine the two domains, we introduce an interaction-gated fusion module that explicitly models feature agreement and discrepancy, while also learning feature-wise weights to balance temporal and spectral information. A parameter-shared regression head further maps the temporal, spectral, and fused representations into the final HR prediction space. Experiments on the benchmark BIDMC PPG and Respiration Dataset using a subject-exclusive training, validation, and test protocol show that TF-IG achieves a mean absolute error (MAE) of 1.227 BPM, a root mean square error (RMSE) of 2.060 BPM, a Pearson correlation coefficient of 0.9934, and 92.28 percent of estimates within 3 BPM, while remaining parameter-efficient with only 84.6K parameters. Ablation results further demonstrate the complementary contributions of the temporal and frequency branches, interaction-gated fusion, and shared regression head. These results indicate that explicitly modeling cross-domain interactions provides an effective accuracy-complexity trade-off for lightweight PPG-based HR estimation.

0.11

LiteEMG-FM: An Efficient and Deployable Foundation Model for Robust EMG Sensing

cs.LG ·2026-10-01 ·Tianhao Wu, Xu Wu, Amirmohammad Radmehr, Jiawei Yu, Yi Wu +2 more
similarity 0.63
Abstract · The authors are withdrawing this manuscript because the current experimental evaluation and validation are insufficient to adequately suppor…

Electromyography (EMG) signals vary substantially across individuals, body regions, recording sessions, and sensing hardware, limiting the generalization of models for assistive devices and human-computer interaction. Existing time-series foundation models are also computationally expensive for real-time wearable deployment and often fail to capture EMG-specific time-frequency characteristics. We present LiteEMG-FM, an efficient hybrid CNN-Transformer foundation model for practical EMG sensing. Pretrained on 16 diverse upper- and lower-limb EMG datasets, LiteEMG-FM learns representations that generalize across users and datasets. For resource-constrained deployment, we implement a hierarchical wake-up architecture in which a lightweight, always-on 1D-CNN filters rest and non-target activity and activates LiteEMG-FM only for valid gestures. We evaluate full inference offloading, split inference, and full on-device processing, characterizing their trade-offs in latency, power consumption, and memory footprint. Across diverse evaluation settings, LiteEMG-FM outperforms state-of-the-art time-series foundation models and supervised baselines, particularly under zero-calibration cross-participant and data-scarce conditions. These results demonstrate that LiteEMG-FM is an effective, efficient, and deployable foundation model for EMG applications.

0.11

Learning Cardiac Features: ECG Biometrics Across Time and~Exercise

cs.AI q-bio.TO ·2026-09-18 ·Luca Thiebaud, Paul Chauchat, Mustapha Ouladsine, Stéphane Delliaux
published similarity 0.62
Abstract

Electrocardiograms (ECGs) carry subject-specific patterns enabling reliable individual discrimination, forming the basis of ECG biometrics. Beyond authentication, this paradigm holds significant potential to secure sensitive cardiac data and to serve as a pretext task in self-supervised learning. Yet, most studies remain confined to singlesession, resting data, leaving robustness to temporal and physiological variations largely untested. We address this gap by evaluating ECG biometrics under realistic conditions involving exercise-induced stress and cross-session variability. A Siamese ResNet with late multi-lead fusion strategy is trained on a large ECG dataset extracted from cardiopulmonary exercise tests and evaluated with a exercise-and time-aware protocol, as well as on public benchmarks. This first extensive assessment of ECG biometrics under combined physiological and temporal variability achieves an intra-session rest-to-peak EER of 1.7% and stateof-the-art 3.9% on the CYBHi dataset. Findings support the presence of an intrinsic cardiac signature resilient to physiological and temporal drift.

0.32