CS Paper Radar

Federated Bayesian Surveillance of Mechanical Thrombectomy Adverse Events: A Population Risk Layer for Surgical Digital Twins

Damini Rijhwani

cs.CR cs.RO ·submitted 2026-10-06 14:49 UTC · v1
publishedbenchmarkunusual

Abstract

Learned surgical simulators and world models can roll out plausible procedural futures, but they carry no grounded estimate of how often interventional devices actually harm patients. We propose treating population-scale adverse-event surveillance as a distinct belief layer of the surgical digital twin, and we evaluate a federated Bayesian protocol for learning it under formal privacy guarantees. Each site holds per-class Gamma-Poisson posteriors over adverse-event rates and exchanges only Rényi-differentially-private natural-parameter updates. We benchmark on the complete FDA MAUDE cohort for thrombus-retrieval catheters (product code NRY): 8,617 reports, of which 6,491 are classified by transparent keyword rules into five thrombectomy complication classes and partitioned across $K=8$ manufacturer sites. At a matched privacy budget of $(\\varepsilon \\approx 2.09, \δ= 10^{-5})$, the conjugate protocol attains a held-out Poisson score of -5.78 per test event versus -26.58 for FedAvg with differential privacy. The non-private federated model also outperforms centralized pooling (+3.19 vs +2.93), evidence that manufacturer-specific complication profiles are real and that federation preserves them. Because MAUDE lacks procedure denominators, outputs are relative rate orderings rather than absolute risks, and we report all privacy-utility operating points.

Comment
Presented at the IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS 2026) Workshop on Surgical Digital Twins (SurgTwin). 3 pages, 1 figure

Closest papers

Nearest neighbours by meaning across the whole index.

TwinGuard-Lite: A Rule-Based State-Admission Gateway for Generative Patient Digital Twins

cs.CR ·2026-10-06 ·Wenhui Chu, Sheikh Rabiul Islam
published similarity 0.60
Abstract · 6 pages, 2 figures, 1 table. Accepted to HealthSec'26 (Cybersecurity in Healthcare), co-located with ACSAC 2026

Future generative patient digital twins may combine longitudinal health records with language-model agents and keep information across sessions. The wording of a proposed update does not reveal whether it comes from an allowed source, conflicts with the patient's record, or belongs to someone else. We present TwinGuard-Lite, a rule-based gateway that admits an update to a twin's persistent state only if it passes checkable approximations of two integrity properties. Grounded state consistency (GSC) is approximated by a provenance check and a contradiction check; cross-patient noninterference (CPN) is approximated by a namespace check against trusted transport metadata. We evaluate three attack families over 20 seeded person-level splits of a semi-synthetic stream built from the openly licensed eICU database demo, with 29,131 $\pm$ 2706 candidate updates per seed. A keyword filter and an anomaly detector detect 16% and 24% of attacks, respectively; a provenance-only ablation detects 59.9% but misses every cross-patient attack. Combining GSC and CPN yields 99.1% precision, 90.5% recall, a 94.6% F1 score, and a 0.033% false-positive rate. Every attack the full gateway admits falsely claims a trusted source; when the retrieval channel does so, 92.9% of retrieval attacks are admitted. The results hold under stated trust assumptions, and no language model, agent, or retriever is executed: TwinGuard-Lite is a mechanism-level proof of concept that motivates authenticated, patient-bound ingestion, not a clinical safeguard.

0.41

Concordance Plausibility Check for Intervention-Conditioned Human Digital Twins

cs.AI ·2026-10-17 ·Saeed Farzi, Christopher Kipps, John McBeth, Gabriela Czanner, Sofia Michopoulou +5 more
similarity 0.55
Abstract

Intervention-conditioned human digital twins predict treatment alternatives that cannot be observed in the same patient. Ordinary predictive accuracy therefore cannot establish counterfactual credibility. We propose the Concordance Plausibility Check (CPC), a claim-centered framework combining real-world evidence, qualified simulation and clinical knowledge. CPC matches evidence to the causal claim, audits contradictions and shared dependencies, and reports Pass, Fail or reason-coded Indeterminate.

0.22

Counterfactual Auditing of Bias in Open-Source Large Language Models for Clinical Triage

cs.AI cs.CLcs.LG ·2026-10-01 ·Manar Aljohani, Brandon Ho, Kenneth McKinley, Dennis Ren, Xuan Wang
code/data similarity 0.53
Abstract

Emergency department (ED) triage is a high-stakes prioritization task in which demographic, socioeconomic, and system-context information may improperly influence acuity assignment. Although open-source large language models (LLMs) are increasingly considered for local and privacy-preserving clinical decision support, it remains unclear how counterfactual bias varies across model families, sizes, medical-domain models, and domain-adapted models. We present a comparative counterfactual audit of ten open-source LLMs for pediatric Emergency Severity Index (ESI) prediction. Starting from real and handbook-style clinical vignettes, we construct paired counterfactual variants that change only one injected demographic, socioeconomic, healthcare-access, behavioral, social, or system-context variable while holding the clinical presentation fixed. Models include Qwen2.5-7B, Qwen2.5-14B-Instruct, a QLoRA fine-tuned Qwen2.5-7B, MedGemma variants, MedLLaMA2-7B, GPT-OSS-20B, and GPT-OSS-120B. We measure any counterfactual shift, undertriage, overtriage, shifts greater than one ESI level, mean shift, and mean absolute shift. Counterfactual sensitivity varied substantially and did not consistently decrease with larger model size or medical-domain pretraining. The fine-tuned Qwen2.5-7B showed the lowest overall sensitivity, with a 5.27% any-shift rate and mean absolute shift of 0.0534, versus 16.02% and 0.1706 for the base model. Several larger or medical-domain models showed more significant shifts. Stratified and correlation analyses further revealed clinically important directionality and shared failure patterns hidden by aggregate rates. These findings support counterfactual auditing as a lightweight, clinically interpretable framework for comparing fairness risks in open-source LLMs before clinical deployment.

0.27

Differentially private federated learning with Byzantine-robust aggregation: A cross-domain framework for secure model training in banking and healthcare systems

cs.CR cs.LG ·2026-09-02 ·Srikumar Nayak
publishedhot direction similarity 0.53
Abstract · 9 pages, Journal research article

Federated learning allows banks, hospitals, and other regulated organizations to train a shared model without moving raw records off their own servers, which is attractive wherever data protection law or competitive sensitivity rules out pooling data centrally. Two problems limit how far this promise can be trusted in practice. First, the parameter updates that clients exchange still leak information about local records through gradient inversion and membership inference attacks. Second, an honest averaging rule such as FedAvg has no defense against a subset of clients that submit corrupted or adversarial updates, so a small number of malicious or compromised participants can quietly steer the shared model off course. This paper presents a federated learning framework, DP-BR-FedAvg, that combines a Gaussian-mechanism differential privacy layer with a coordinate-wise trimmed-mean Byzantine-robust aggregation rule, evaluated on a simulated cross-institutional classification task resembling fraud and clinical-risk scoring. Across sixty communication rounds with twenty clients, a quarter of them Byzantine, plain FedAvg collapses on the minority class (F1-score 0.030) while the proposed framework recovers substantially more of the signal (F1-score 0.119) while bounding the privacy loss of any single client's contribution. A Byzantine-robust aggregator with no privacy layer performs best in raw accuracy, quantifying the cost privacy imposes on robustness. The results show that privacy and robustness mechanisms interact rather than simply add, and that system design for regulated, adversarial, cross-institutional settings needs to budget for that interaction.

0.37

OmniMed-FL: A Robust Multimodal Federated Learning Framework for Clinical Diagnosis

cs.LG cs.AI ·2026-09-09 ·Ayush Debnath, Ruelia Saha, Sudip Misra
published similarity 0.53
Abstract · Accepted in IEEE Globecom 2026, E-Health

Simultaneous assessment of medical imaging and patient records is often required in clinical diagnosis. However, standard machine learning algorithms cannot analyze these data types together. Meanwhile, compliance with HIPAA and GDPR can constrain centralized aggregation of sensitive patient data. This leaves a crucial void of secure fusion of visual and textual context across distant networks. Thus, we present OmniMed-FL, a controlled systems study of multimodal federated learning for five-class clinical condition classification (Normal, Pneumonia, COVID-19, Pleural Effusion, Cardiomegaly). Our proxy corpus pairs 3,000 public chest radiographs with 3,000 class-conditioned synthetic notes, matched by class, not by patient. The framework benchmarks eight fusion strategies, three initializations, four missing-text imputation rules, and matched federated baselines under non-IID Dirichlet partitioning across 3 to 20 hospital clients. As all notes are synthetic and pairing is not patient-level, these are descriptive proxy comparisons, not estimates of diagnostic performance or deployment readiness. Within those limits with clients ($K=5$) and severe skew ($α=0.1$), local-only training achieves a macro-F1 score of 0.297, FedAvg achieves $0.662\pm0.074$, FedProx $0.737\pm0.085$, a matched FedMME-style one-shot ensemble $0.647\pm0.080$, and our SCAFFOLD-AdamW adaptation $0.070\pm0.015$, the 0.075 FedProx-FedAvg gap falling inside the wider of the two two-seed standard deviations. Over a $4\times3$ grid, label skew costs up to 0.27 F1 whereas a near-sevenfold client increase costs at most 0.10, while bidirectional volume grows linearly to 183.5 GiB at $K=20$. Multimodal fusion leads on both corpora, scoring 0.956 against 0.934 for text and 0.664 for images on the synthetic corpus and 0.906 against 0.880 and 0.737 on the radiograph corpus, for $2.3\times$ the model state of text alone.

0.27

Bounds on the Posterior-to-Prior Ratios for Inclusion Belief under Bounded Differential Privacy

cs.CR math.ST ·2026-08-31 ·Jan Reiter Sørensen, Heidi Søgaard Christensen, Rasmus Rask Kragh Jørgensen, Martin Bøgsted
hot direction similarity 0.53
Abstract · 24 pages, 3 figures

Differential privacy has become the standard for generating privacy-protected data releases. However, differential privacy does not translate intuitively to disclosure risk. In particular, it remains unclear how much an adversary's belief about an individual's inclusion in a dataset can change after observing a protected release. To address this question, we derive upper and lower bounds on the posterior-to-prior ratios of inclusion beliefs under bounded probabilistic and approximate differential privacy. By assuming a worst-case adversary with all-but-one auxiliary information, i.e., knowledge of all except for one of the participants in a dataset, we obtain bounds that apply to any adversary. Because these bounds may fail with non-zero probability, we study the corresponding failure probability for the Gaussian mechanism. We derive a theoretical upper limit on this probability and compare it with Monte Carlo estimates across a wide range of parameter settings. The observed failure rate is several orders of magnitude smaller than its theoretical upper limit, indicating that the latter is highly conservative. These findings suggest that the inferential privacy guarantees provided by differentially private mechanisms may be substantially stronger in practice than what is implied by the theoretical upper limit.

0.26

Accuracy Is Not Risk: Why Medical AI Should Not Report Only Its Most Likely Label

cs.CY stat.MEcs.LGstat.AP ·2026-10-31 ·Jeffrey Humpherys, Makoto Jones
similarity 0.52
Abstract

Background. Many medical AI models are trained to reproduce a single reference label and hand the most likely label to the next step in a clinical workflow. A classifier can select that label correctly while providing an inadequate summary for estimating downstream risk. Methods. We use Jeffrey's rule of conditioning to specify when probabilities over intermediate states, such as diagnoses or imaging categories, can be carried forward to an outcome risk. We separate two errors of reporting only the most likely label, discarding the probability of the other states and applying the risk of patients who have the leading diagnosis to a patient who only probably has it. We also give conditions under which the label and the full distribution lead to the same decision, and we propose guardrails for device developers, regulatory reviewers, and health insurers. Results. In a hypothetical chest-pain differential, reporting only the benign leading diagnosis greatly understates the patient's risk of death or cardiac arrest, so a patient who warrants evaluation could be discharged or denied imaging. In a hypothetical BI-RADS example, the most likely category is "probably benign," yet the propagated malignancy risk exceeds the ceiling that defines that category. Conclusions. A predicted label is not an observed state, and a calibrated classifier is not automatically a valid outcome model. Clinical and insurance coverage decisions should rest on the patient's outcome risk, judged against a threshold justified by the consequences of acting and not acting. Developers should state what each model output means and check that every step between the model and the decision preserves the patient's risk.

0.07

PrivMeSA: Privacy-Aware Self-Evolving Multi-Agent System for Medicine via Local-Remote LLM Collaboration

cs.AI ·2026-09-29 ·Dannong Wang, Yuran Zhang, Bian Sun, Alex Stinard, Yuzhang Shang +2 more
benchmark similarity 0.52
Abstract

Clinical large language model (LLM) agents deployed locally can consult more capable remote models, but doing so risks exposing patient information. Privacy-conscious delegation places disclosure decisions with a local agent, yet removing explicit identifiers is insufficient: quasi-identifiers can accumulate across multi-turn consultations and repeated patient visits to enable re-identification. We introduce PrivMeSA, a privacy-aware self-evolving multi-agent system that learns to control disclosure and retains remote expertise for local reuse. A local agent manages each encounter and consults remote specialists that may request additional information. Reinforcement learning balances task accuracy against direct disclosure and registry-based re-identification risk, with privacy evaluated over the complete outbound transcript of each encounter. A local lesson memory distills completed consultations into generalized clinical guidance and retrieves relevant lessons before transmission, allowing subsequent cases to reuse expertise without another remote exchange. Memory grows without additional outcome labels or parameter updates. On an emergency-department benchmark built from MIMIC-IV-ED records, PrivMeSA improves mean task accuracy over delegation by up to 15.8 percentage points. In the same setting, PrivMeSA reduces the disclosure of personal details from 98.0% to 0.2% of cases and the share of cases in which the patient can be narrowed to ten or fewer registry patients from 74% to 0%.

0.16