Abstract

Purpose: Current abdominal ultrasound (US) simulation methods often require CT-based anatomical references for ray-casting, limiting deformation and pathology variability. We propose a learning-based pipeline trained to predict physics-based images derived from CT scans from semantic labels, enabling controlled simulations without patient-specific CT volumes at inference time. Methods: We introduce a two-stage pipeline that maps anatomical segmentations to realistic US images through a simplified US image. Stage~I synthesizes this image from semantic labels using models trained on CT-based ray-casting outputs. Stage~II refines it into a realistic US scan using anatomically guided unpaired translation. Deformations and pathologies are generated by editing anatomical maps. Results: We evaluated Pix2Pix and the Semantic Diffusion Model (SDM) in Stage~I, followed by segmentation-guided CycleGAN (SG-CycleGAN) refinement in Stage~II. SDM significantly outperformed Pix2Pix in morphological metrics, including MAE (19.85 vs. 21.65), SSIM (0.28 vs. 0.24), and mIoU (0.43 vs. 0.29), whereas Pix2Pix yielded better perceptual point estimates (LPIPS: 0.17 vs. 0.19; FID: 0.32 vs. 0.37; KID: 0.25 vs. 0.48). Conclusion: Training paired generative models with physics-based supervision enables approximation of CT-derived ray-casting outputs at inference time directly from semantic labels. Although the pipeline does not require patient-specific CT volumes at inference time, CT-derived segmentations and ray-casting simulations remain necessary to train Stage~I. Once trained, the framework enables controllable healthy and pathological simulations through semantic-map modification.

Closest papers

Nearest neighbours by meaning across the whole index.

An Anatomy-guided 3D Segmentation Pipeline for Prostate Surgical Phantoms from CT Scans

cs.CV ·2026-11-05 ·Iven Chen, Kuan-I Chung, Ayberk Acar, Susheela Sharma Stern, Alejandro O. Chara +2 more
similarity 0.69
Abstract · 11 pages, 2 figures, 3 tables, 10 algorithms. Extended abstract accepted at SPIE Medical Imaging 2027: Image Processing

Full autonomy has been a long-term goal in robotic surgery and a near-to-medium-term goal for prostatectomy. Due to the relatively closed structure of the procedure, its standard-of-care robotic/laparoscopic solutions, and procedure economics, prostate procedures are an optimal early target for surgical automation. Prototyping and testing of possible solutions is done in constructed laboratory phantoms, either synthetic tissues or animal phantoms. To enable measurement of perceptual and robotic motion error, phantoms undergo volumetric imaging; these images are critical to both a potential deployed automatic system, used in planning motion and treatment (cutting, ablation, suturing, etc.), as well as post-hoc assessment of system performance. Rapid iteration on these phantom models yields small, inconsistent datasets, while the current workflow for human annotation is often anatomically unreliable and prohibitively time-consuming, rendering deep learning unsuitable at reasonable scales. To address these limitations, we present an automated 3D segmentation pipeline that uses classical medical image-processing techniques to encode the known anatomy of the phantoms as explicit geometric and intensity priors, which requires no training corpus and is transferred to each new phantom revision without re-annotation. Across 57 scans spanning multiple phantom revisions, our pipeline recovers the capsule interior at 0.83 median Dice on 11 contrast-suppressed scans and detects all 32 annotated focal lesions without false positives, completing a full scan in 2-8 minutes on commodity CPU hardware versus 1-2 hours by hand.

0.35

Pretrained, Curriculum-Tuned, and Ensembled: A Tracer-Aware Interactive Segmentation Pipeline for AutoPET V

cs.CV cs.AI ·2026-08-31 ·Xinglong Liang, Chunyao Lu, Tianyu Zhang, Jiaju Huang, Tao Tan +2 more
code/data similarity 0.68
Abstract

Interactive lesion segmentation in whole-body PET/CT requires a model to provide a strong initial prediction while also responding efficiently to sparse corrective scribbles during inference. This setting is particularly challenging because tracer distributions, physiological uptake patterns, lesion appearance, and acquisition characteristics differ substantially between FDG and PSMA studies. We present TRIAGE, Tracer-aware Refinement via Interactive Anatomy-Guided sEgmentation. The core backbone is a 3D STU-Net initialized through masked autoencoding pre-training with an asynchronous masking strategy, aiming to learn transferable anatomical and cross-modal representations before task-specific fine-tuning. In parallel, we train an auxiliary organ segmentation model whose predictions provide explicit anatomical context and help distinguish physiological uptake from malignant lesions. A dedicated tracer classifier first routes each study to an FDG- or PSMA-specific branch. Within each branch, a first-stage segmentation model consumes CT, PET, and organ context to generate an initial lesion mask. The initial prediction is then combined with cumulative foreground/background scribbles and refined by a second interactive segmentation network. The FDG and PSMA branches share the same overall processing pipeline but are trained independently to account for tracer-specific appearance and error modes. We additionally employ curriculum-style training and model ensembling to improve robustness across interaction steps and heterogeneous cohorts. Experiments are conducted using the official AutoPET V data and ten-fold split; quantitative results, ablations, and final test-set performance are left as placeholders to be completed after the challenge evaluation. Code: https://github.com/Liiiii2101/AUTOPET2026-MEDAI.

0.24

FleXray: Universal Clinical X-ray Segmentation

cs.CV cs.AI ·2026-09-22 ·Victor Ion Butoi, Vivek Gopalakrishnan, John V. Guttag, Adrian V. Dalca, Neel Dey
similarity 0.68
Abstract · 35 pages, 12 figures, 10 tables. Code, models, data, and a browser-based demo at https://flexray.csail.mit.edu

X-ray is medicine's most widely used imaging modality, yet remains among its least quantitative. Unlike volumetric modalities like CT or MRI, X-ray collapses 3D anatomy into a 2D projection, causing structures to overlap and anatomical boundaries to be ambiguous, even to experts. As a result, labeling X-ray databases for training general-purpose segmentation systems is impractical, leaving morphometric and functional X-ray analysis confined to narrow anatomical regions and applications. To this end, we present FleXray, a generalist model for anatomical segmentation across the entire body in clinical X-rays. Instead of curating large, manually annotated X-ray datasets, we build a scalable, physics-based generative X-ray data engine. Using existing 3D whole-body CT segmentation datasets and generative image-editing models, we simulate fully-annotated 2D X-rays with diverse appearances, physiological properties, and imaging geometries. Trained on these simulations, FleXray accurately segments 60 anatomical structures across unseen research datasets and in-the-wild X-rays. We further show that FleXray makes X-rays directly amenable to quantitative analysis, enabling automated measurements for disease grading, robust navigation during X-ray-guided interventions, and data-efficient learning of pathological targets. We release the model, code, a full-body X-ray segmentation dataset, and a local, easy-to-use browser-based tool at https://flexray.csail.mit.edu .

0.27

ReSeg: Retraining-free segmentation of abdominal organs via generalizable semantic representation learning

cs.CV cs.AI ·2026-10-21 ·Derong Yu, Guoyan Zheng
similarity 0.67
Abstract

Abdominal organ segmentation is essential in modern medical applications. While existing deep learning approaches demonstrate promising performance, their heavy reliance on large-scale image data raises concerns over generalization capability and privacy risks. This motivates the development of generalizable segmentation training paradigms based on domain-randomized image synthesis, facilitating generalization across unseen real image domains. However, existing paradigms either suffer from limited segmentation performance when applied to abdominal organs, or require dataset-specific finetuning. To address these limitations, we propose ReSeg, a novel two-stage retraining-free framework for domain-agnostic zero-shot abdominal organ segmentation. At the first stage, our organ-agnostic synthetic data-driven pretraining approach exploits semantically and visually diverse synthetic images generated by a dedicated data engine to optimize a Generalizable Semantic Representation Network (GSRNet). The network is thereby capable of learning semantic features robust against variations in anatomical structure, imaging contrast, resolution and spatial context, which provide universal representation capabilities that serve as a foundation for segmentation learning. Subsequently, in the second stage, we continue to train an Organ-specific Encoder-decoder Segmentation Network (OESNet), whose encoder is initialized with the pretrained weights. This training process is facilitated by another dedicated data engine, which generates diversified visual images while strictly retaining the inherent spatial layout of abdominal organs. Comprehensive evaluation on seven abdominal organ segmentation datasets across three different modalities including CT, MRI, and PET demonstrates that ReSeg consistently outperforms existing state-of-the-art (SOTA) methods while eliminating the need for real training images.

0.18

B-MIM: Biased Masked Image Modeling for Generalizable Segmentation of Fine-Grained Anatomical Structures

cs.CV ·2026-08-25 ·Sebastián González, Karen Sanchez, José M. Saavedra, Marcelo Pizarro, Bernard Ghanem
published similarity 0.67
Abstract · Published at MedAGI in MICCAI 2026

Self-supervised pretraining enables transferable representations for medical imaging, yet most CT encoders remain biased toward coarse semantic understanding, limiting their sensitivity to fine-grained anatomical structures such as vessels or small tumors. In this paper, we introduce Biased Masked Image Modeling (B-MIM), a modification of the iBOT objective that stochastically reduces global semantic alignment to prioritize local patch reconstruction. This bias encourages the encoder to capture high-frequency morphological details and structural continuity. We curate a multi-institutional CT abdominal dataset of 9,955 filtered studies from 17 public sources and pretrain a 3D Swin Transformer backbone using B-MIM. Across inter-dataset experiments on liver vessel segmentation, the proposed encoder improves topological fidelity (clDice) and achieves competitive Dice scores in tumor segmentation, compared to fully fine-tuned baselines, despite updating only a fraction of the parameters. Our results suggest that reducing global semantic pressure during pretraining enhances generalization to intricate anatomical structures.

0.25

DART: Scaling a Shape Representation Across Anatomical Classes and Imaging Modalities

cs.CV ·2026-10-20 ·Koushik Swarna, Pedro R. A. S. Bassi, Lam Ngo, Wenxuan Li, Jiancheng Yang +2 more
code/data similarity 0.67
Abstract

Current state-of-the-art segmentation models still produce anatomically implausible shapes, such as broken vessels and fragmented glands, on the structures that are hardest to segment. Learned shape representations capture what structures look like and can help correct these errors, but most cover a fixed set of anatomical classes. Extending this coverage across classes and imaging modalities is costly because it often requires new voxel-level annotations. We propose Diffusion for Anatomical Reshaping with Text (DART), which learns a shared shape representation from segmentation probabilities. It uses anatomical descriptions to correct these probabilities without receiving medical images. Across 13 public benchmarks, absolute Dice gains reach 31% for individual gallbladder cases in CT and 10% for individual prostate cases in MRI. Using existing segmentation predictions, we scale a single shape representation from 50 to 377 anatomical classes without new voxel-level annotations for correction training. The shared representation also corrects four lesion classes absent from training and transfers from CT to MRI without retraining. Corrected labels also improve segmentation models, raising one model's Dice from 57.1% to 67.5%. The same pipeline supports annotations for 45,000 CT scans. These results suggest that sharing shape information within and across classes can reduce the need for new voxel-level annotations when extending segmentation to more anatomical classes and imaging modalities. The model is available at https://huggingface.co/Koushik45/DART-Seg

0.26

Registration is a Representation Problem: Solving Whole-Body PET/CT Registration

cs.CV cs.LG ·2026-10-13 ·Neel Dey, Adrian V. Dalca
publishedbenchmarkcode/data similarity 0.66
Abstract · Technical report. First place winning solution for the MICCAI Learn2Reg 2026 PSMAReg challenge. Code and volumetric visualizations are avail…

Raw image intensities are a poor surrogate for similarity across images in correspondence problems. Further, while auxiliary segmentation labels can provide semantic identification and improve matching, they can assign only coarse identities to fine-grained anatomy and often cover only a subset of structures, particularly in whole-body settings. We present an approach that instead establishes correspondence using complementary representations of anatomy and demonstrate its utility for longitudinal whole-body PET/CT registration in the Learn2Reg 2026 PSMAReg Challenge. We use our 3D foundation model, anatomix, to derive fine-grained, per-voxel semantic representations that are consistent across volumes and further employ off-the-shelf segmentation models to obtain coarse anatomical identities. Together, these representations drive a GPU-accelerated iterative registration solver (FireANTs) in a hybrid multistage framework: the first stage estimates alignment from dense multi-channel features, after which a second refines the deformation using both anatomix- and segmentation-based losses. Lastly, because registration should not introduce non-biological tumor volume changes across time, we develop lesion-specific, component-wise volume preservation schemes. Without any task-specific training, our system placed first on the PSMAReg Challenge leaderboard. Code and interactive visualizations are available at https://www.neeldey.com/reps-for-reg.

0.31

MAGEFormer: Learning Metric-Consistent Representations for Anisotropic CT Segmentation

cs.CV cs.AI ·2026-10-02 ·Jiaying Li, Paolo Remagnino
top venue similarity 0.66
Abstract

Vision Transformers (ViTs) have shown strong performance in volumetric segmentation, but their effectiveness on clinical CT is limited by an isotropic Euclidean lattice assumption. This conflicts with anisotropic CT acquisition, leading to two key issues: (1) a metric mismatch between voxel indices and physical anatomy, and (2) accuracy degradation from isotropic resampling. To address this, we propose MAGEFormer, a geometry-calibrated framework that embeds physical metric constraints directly into representation learning. Our method introduces Metric-Adaptive Spatial Embedding (MASE) to calibrate positional frequencies using voxel spacing, Geometry-Constrained Attention (GCA) to suppress physically implausible feature correlations, and Geometric View Voting (GVV) to reduce discretization bias during inference. We evaluate MAGEFormer on two multi-organ abdominal CT benchmarks, BTCV and FLARE 22, under a unified protocol against strong CNN and Transformer-based baselines. MAGEFormer achieves the strongest boundary accuracy among the compared methods, with 10.58 mm HD95 on BTCV and 3.40 mm HD95 on FLARE 22, and shows consistent gains in Dice under the same protocol. These results show that geometry-aware internal calibration is more effective than relying on conventional isotropic preprocessing alone for anisotropic CT segmentation.

0.32