CS Paper Radar

One-Slide Calibration of Pathology Foundation Models

Ming Ren Hou, Tianyi Huang

cs.CV cs.AI ·submitted 2026-10-06 18:09 UTC · v2
published

Abstract

Scanner variation changes how pathology foundation models represent the same tissue. We introduce SlideRuler, which uses other regions within a slide as internal controls to predict a query region's scanner-induced shift. A transfer map learned from paired rescans enables calibration from a single scan at inference while keeping the foundation model fixed. Across two encoders and five SCORPION scanners, learned transfer reduces mean target-to-source embedding distance by 16.3-38.5% relative to raw embeddings. Replacing controls with unrelated same-scanner regions reveals a positive same-slide contribution in all four evaluation settings, including scanner holdout. A source-anchored variant reduces source-feature displacement by 47.7-83.6% relative to learned transfer while retaining most of its alignment gain. By drawing calibration information from the slide itself, SlideRuler offers a path toward more consistent use of frozen pathology models across imaging systems.

Comment
Accepted at the NeurIPS 2026 Workshop AI at Scale for Clinical Impact (ASCI): Cancer Pathology Foundation Models

Closest papers

Nearest neighbours by meaning across the whole index.

HERO: Histology Encoder for Robust Representation in Oncology

cs.CV ·2026-09-28 ·Zhi Li, Eghbal Amidi, Yating Cheng, Tyson Dawson, Gorkem Can Ates +9 more
benchmarkcode/data similarity 0.69
Abstract · 22 pages, 4 figures, 13 tables; author information updated; scientific content unchanged

Foundation models trained on large pathology image corpora now provide strong, transferable representations for computational pathology. Over the past few years a series of such models has been released, each trained on more slides than the last; on standard classification and segmentation benchmarks, the leading models are now separated by small margins. In clinical use, however, the foundation model is applied to images from hospitals, scanners, and staining protocols outside its training data. Encoders generally embed these acquisition factors alongside biological information, which may introduce downstream errors and hinder safe clinical adoption. A pathology foundation model should therefore be robust to acquisition shift without giving up representation quality, yet robustness is seldom the axis along which models are compared. In this report, we introduce HERO (Histology Encoder for Robust Representation in Oncology), a ViT-G/14 pathology foundation model trained with the DINO and iBOT objectives and refined with high-resolution Gram anchoring on a morphology-balanced corpus of 500 million tiles from approximately 575,000 clinical whole-slide images. Across the evaluated public benchmarks, HERO shows the strongest robustness to center, scanner, and stain variation among the compared state-of-the-art foundation models, performs comparably on tile-level classification, segmentation, and gene-expression prediction, ranks first on average across 39 evaluated slide-level clinical tasks, and, under an equal-weighted framework-level analysis, has the best average rank across the six benchmark frameworks.

0.22

Contrastive fine-tuning against stain and scanner bias improves robustness and downstream performance across pathology foundation models

cs.CV ·2026-11-06 ·Ryan Kim, Hassan Muhammad, Anish Dulal, Paul S. Scotti, Tanishq Mathew Abraham
code/data similarity 0.67
Abstract · ASCI Workshop, Neurips 2026

Histopathology foundation models achieve strong performance across diverse downstream tasks, yet their representations have been shown to encode scanner- and site-specific biases, creating generalization gaps and potentially limiting real-world utility. We introduce SPECTRA (Scanner and Pathology Embedding Contrastive Tuning for Robust Alignment), a model-agnostic contrastive learning post-training framework which explicitly encourages scanner- and stain-robust representations, to optimize performance and generalization on downstream applications. Using parameter-efficient LoRA adapters trained on matched multi-scanner and multi-stain whole-slide images sourced from the PLISM dataset, our method aligns spatially corresponding regions across acquisition conditions (scanner, stain), using other locations within each candidate condition as negatives. SPECTRA improved PathoROB robustness index, gene-expression prediction on HEST, slide-level classification AUC on CPTAC, and held-out PLISM retrieval for every model. Overall tile-level classification on THUNDER also improved, with exceptions for segmentation and calibration tasks. We open-source our training and evaluation codebases and release adapters and model weights for selected backbones.

0.18

The Predictability Bias of Joint-Embedding Predictive Learning in Medical Imaging

eess.IV cs.CVcs.LG ·2026-10-09 ·Fabian Drexel, Bernhard Kainz, Jakob N. Kather, Daniel Rueckert, Lisa C. Adams +2 more
similarity 0.66
Abstract · 45 pages, 6 figures

Joint-embedding predictive architectures (JEPAs) learn by predicting teacher representations of masked regions from visible context. Point prediction summarizes the conditional target distribution and cannot reproduce variation that the context does not resolve. We call this constraint predictability bias. In computed tomography (CT), recurrent anatomy is predictable from context, whereas the sporadic, localized pathology that determines clinical interpretation often is not. We introduce TAP-JEPA, a ViT-B/3D trained on 113,611 CT volumes that is competitive with state-of-the-art encoders (COLIPRI, Merlin, VoxelFM) in scan-level classification. We then audit the learned predictive pathway by replaying the exact masking, teacher, and predictor computations used during training. Prediction lowers the mean Skill (prevalence-normalized average precision) from 0.388 to 0.271 for pathology, but only from 0.921 to 0.873 for anatomy. Along the teacher direction, separating pathology from matched control regions in the same organ, prediction moves pathology 34.7% toward the controls and controls 13.6% toward pathology, with larger shifts farther from visible context. Replacing visible matched-control representations increases surrounding-target prediction loss more than fully replacing pathology representations across four pathology categories. Downstream, removing all final-layer pathology tokens reduces the decision margin by at most 0.45% in four of seven scan-level probes. Together, these results show that contextual predictability is not a sufficient proxy for clinical relevance in medical representation learning. Training objectives should therefore retain diagnostic features regardless of their predictability from surrounding anatomy.

0.19

Can Protein-Derived Knowledge Improve Pathology Foundation Models?

cs.CV ·2026-09-27 ·Di Zhang, Zhangpeng Gong, Jiashuai Liu, Zhi Zeng, Jiusong Ge +8 more
similarity 0.65
Abstract

Molecularly guided pathology foundation models (PFMs) exploit transcriptomic or proteomic information to enrich whole-slide image (WSI) representations, yet effectively leveraging large standalone molecular corpora remains challenging. First, existing molecular foundation models encode protein sequences or single-cell states, not the patient-level bulk expression profiles paired with WSIs. Second, because cross-modal supervision is restricted to paired WSI-omics samples, knowledge from standalone molecular corpora reaches the pathology encoder only indirectly, creating a paired-support bottleneck. To address these challenges, we propose a three-stage framework that decouples proteomic knowledge acquisition from cross-modal transfer, yielding ProSlide, a slide-level hierarchical pathology foundation model. First, to close the modality gap, we pretrain a Proteomic Foundation Encoder (PFE) on 12,695 sample-level bulk protein profiles using virtual profile generation and expression-space multi-view pretraining. Second, we pretrain ProSlide, a patch-region-slide encoder, to predict protein expression from paired WSI-protein samples. Third, to relax the paired-support bottleneck, we introduce Prot2Path, a cross-modal relational distillation objective. For each paired sample, it aligns the similarity distributions of the WSI and its protein profile over a shared, frozen bank of PFE-encoded paired and standalone profiles. We evaluate ProSlide on 12 downstream tasks across breast, lung, and renal cancers. Despite being pretrained with only 2,229 WSIs and 12,695 sample-level protein profiles, ProSlide achieves the highest mean accuracy and AUC within each cancer group.

0.23

Role-Guided MOE for Encoder-Level Pathology Representation Learning in WSI Classification

cs.CV ·2026-09-28 ·Xinyu Ma, Xing Yang, Hongtao Jin, Guoquan Zhang, Shijie Zhang +2 more
similarity 0.64
Abstract

Whole slide image classification is a fundamental task in computational pathology, where patch representation quality directly affects downstream aggregation and slide-level discriminability. Pathology foundation models are widely adopted as frozen feature extractors for WSI classification; however, their fixed encoders may produce representations insufficiently adapted to target-specific tissue patterns and discriminative cues. Fine-tuning can improve target adaptation, but introduces a trade-off between pathology-specific representation capacity and adaptation efficiency, particularly in data-scarce settings. To address this, we propose a pathology role-guided mixture-of-experts feed-forward network (MoE-FFN) framework for efficient encoder-level representation learning. We design a two-stage training paradigm to establish and adapt pathology-aware expert specialization. In source-domain expert initialization, pathology-specific priors are distilled from a frozen Virchow2 teacher into a lightweight DINOv2-small student, while role prototypes serve as weak pathological anchors to encourage distinct expert functions. MoE-FFN blocks are introduced into selected high-level transformer layers to provide transformation diversity for heterogeneous pathological patterns. In target-domain adaptation, the initialized experts are refined through asymmetric prototype-guided optimization, enhancing task-relevant positive evidence and separating confusable hard negatives. The resulting encoder extracts offline patch representations that can be directly integrated with standard MIL aggregators. Experiments on the public BRACS dataset and a private PAROTID WSI dataset across five representative backbones demonstrate consistent improvements over the strongest baseline.

0.12

MOSAIC: Towards a Universal Latent Space for Computational Pathology Foundation Models

cs.CV cs.AI ·2026-10-19 ·Dibaloke Chanda, Praveen Madiraju
publishedcode/data similarity 0.63
Abstract · Accepted at WACV 2027

Pathology foundation models (PFMs) differ substantially in architecture, pretraining objective, training data and representation dimensionality, yet it remains unclear whether they learn fundamentally different feature spaces or alternative coordinate systems of a shared underlying representation. We present MOSAIC, a systematic study of latent-space similarity, alignment and interoperability across $12$ patch-level and $6$ slide-level PFMs. We first quantify representational agreement using complementary similarity measures and analyze how architecture, pretraining objective, network depth and magnification influence latent geometry. We then evaluate multiple alignment strategies for mapping independently learned representations into a common latent space. The resulting representations are evaluated through cross-model agreement, retrieval, geometry preservation, and downstream multiple-instance learning across molecular and morphological prediction tasks. MOSAIC provides a unified framework for studying whether heterogeneous PFMs can move beyond representational similarity toward a shared and functionally transferable pathology representation space. Our code, benchmarks and additional results are available at https://researchsubmissions66.github.io/MOSAIC/.

0.42

Impact of Pretraining Length, Model Size, and Annotation Budget on Downstream Clinical Tasks of Foundation Models in Radiotherapy

cs.CV ·2026-11-17 ·Alejandro Cortina Uribe, Sidsel Højklint Poulsen, Ivan Richter Vogelius, Jens Petersen
code/data similarity 0.63
Abstract · 9 pages, 5 figures, 2 tables. Supplementary Material included

Cone-beam CT (CBCT) scans acquired during radiotherapy capture changes such as tumor shrinkage and radiation-induced tissue changes, offering great potential for foundation models that help monitor individual treatment responses. However, to our knowledge, no large-scale pretrained models for radiotherapy CBCT exist, and evaluating modeling choices is difficult since downstream tasks are not known in advance. We examine how pretraining length, model size, and finetuning strategy relate to downstream clinical performance, and how metrics tracked during pretraining correlate with it. We pretrain vision transformer encoders with masked image modeling on about 150,000 raw 3D radiotherapy CBCT scans, tracking representation quality via validation loss, effective rank, and linear probing. Downstream tasks are classification of feeding tube presence ($n=51,135$ CBCTs, $1,562$ patients) and clinical characteristics (T-, N-stage, sex, age, tumor site; $n=1,278$ patients) in head and neck cancer. We compare low-rank adaptation (LoRA) and full finetuning against no pretraining, varying annotated dataset size. Pretext validation loss was the most consistent predictor of downstream performance; effective rank and linear probing were also associated, but not consistently across model sizes and finetuning methods. LoRA performed comparably to full finetuning while training only 0.5-2.5% of the parameters. Fully finetuned models consistently outperformed models without pretraining across all sizes, with AUROC 0.91-0.97 vs. 0.58-0.85 for feeding tube classification and 0.99-1.00 vs. 0.71-0.97 for sex classification. Model size had only a small, inconsistent effect, suggesting smaller models suffice at lower computational cost. Code and pretrained models (non-commercial license): https://github.com/alexCortinaU/RT-CBCT_SSL

0.44

Multimodal LLMs Outperform Pathology Foundation Models in Cross-Domain Histological Similarity

cs.CV cs.AIcs.CLcs.LG ·2026-09-26 ·Yishu Zhang, Yun Li, Daiwei Zhang
publishedbenchmark similarity 0.63
Abstract · To appear in NeurIPS 2026 (https://neurips.cc/virtual/2026/poster/152201)

State-of-the-art pathology foundation models, trained on millions of histology tiles, can fail to preserve tissue similarity when comparisons cross slide or institution boundaries. We show that general-purpose multimodal LLMs, without being trained as pathology foundation models, consistently outperform these specialized models in cross-domain histological similarity judgments. Using a relative similarity framework that we release as the MOSAIC (Model Similarity Assessment across Institutions and Cohorts) benchmark, we evaluate 17 models across 6 datasets and find that pathology encoders often rank same-institution, different-disease tiles as more similar than same-disease, different-institution tiles, a clinically dangerous failure mode invisible to standard within-domain evaluations. LLMs appear less susceptible to this failure, likely because they perform semantic visual comparison of morphology and tissue architecture rather than relying on shortcut features tied to acquisition context. Scaling training data does not resolve the problem for pathology encoders, implicating the learning objective rather than data coverage. Our results expose a fundamental robustness gap in current pathology foundation models and establish multimodal LLMs as a viable alternative for cross-institutional retrieval, dataset harmonization, and multi-site quality control. Code and data will be released upon acceptance.

0.35