CS Paper Radar

Missing Modality-Aware Calibration for Trustworthy Brain Tumor Segmentation

Sol Lee, Hyunji Kim, Sungrae Hong, Donghee Han, Mun Yi

cs.CV cs.AI ·submitted 2026-10-08 07:46 UTC · v1
top venue

Abstract

Multimodal brain tumor segmentation typically leverages multiple MRI modalities, yet incomplete modality acquisition is common in clinical practice due to protocol heterogeneity and scan failures. Although recent methods maintain segmentation accuracy under missing modality conditions, they frequently overlook prediction reliability, leading to miscalibrated confidence estimates that hinder clinical adoption. Existing calibration techniques are largely modality-agnostic or assume that prediction difficulty decreases monotonically as additional modalities become available. However, in brain tumor segmentation, prediction difficulty depends primarily on which modalities are absent rather than how many, leading to combination-specific and spatially heterogeneous calibration errors. To address this, we propose Missing Modality-Aware Local Temperature Scaling (MMA-LTS), a post-hoc voxel-wise confidence calibration method. It estimates a spatially adaptive temperature field conditioned on a modality-availability learnable token and a voxel-wise difficulty score. Experiments on BraTS 2020 and FeTS 2024 show that MMA-LTS improves calibration while preserving the segmentation accuracy of state-of-the-art models across diverse missing-modality scenarios, thereby enhancing trustworthiness toward clinical deployment.

Comment
MICCAI2026 poster

Closest papers

Nearest neighbours by meaning across the whole index.

CAPS: Clinically-Verifiable Anatomy-Prioritized Synthesis for Missing MRI Imputation in Brain Tumor Segmentation

eess.IV cs.CV ·2026-10-20 ·Cecilia Diana-Albelda, Arthur Longuefosse, Mario Rubén Paz Campos, Álvaro García-Martín, Jesus Bescos
similarity 0.71
Abstract · 20 pages, 6 figures, 8 tables. Cecilia Diana-Albelda and Arthur Longuefosse contributed equally

Multi-parametric MRI is the gold standard for neuro-oncology, yet acquiring complete 4-modality protocols may be unfeasible in real-world clinical practice. When handling missing modalities, existing automated systems force a critical compromise: robust segmenters operate as uninterpretable "black boxes" that bypass image generation, while standard synthesis models often produce blurry reconstructions lacking diagnostic reliability. To address this issue, we propose CAPS, a Clinically-Verifiable Anatomy-Prioritized Synthesis framework that reconciles computational precision with clinical transparency. Our multi-modal generative architecture is driven by a hybrid objective function (L_1 + L_AFP + L_DualDice) that explicitly enforces the preservation of deep anatomical features and strict topological boundaries, rather than relying solely on pixel-wise optimization. Evaluated comprehensively on the BraTS Adult Glioma dataset, the framework achieves superior synthesis fidelity across intensity-based metrics, and demonstrates robust downstream segmentation performance (82.38% mean Dice), successfully restoring verifiable visual context. Furthermore, the framework exhibits exceptional zero-shot cross-domain generalization, maintaining high structural fidelity across completely unseen Meningioma, Pediatric, and Sub-Saharan African cohorts without domain-specific adaptation. Finally, a blinded radiological assessment confirms that our anatomy-aware approach significantly enhances both perceived image quality and clinical utility, providing clinicians with the reliable visual evidence required to trust downstream automated workflows.

0.20

MicroBT: Centroid-Guided Synergistic Learning for Multi-Modal Micro Brain Tumor Segmentation and Counting

cs.CV cs.AI ·2026-11-10 ·Zhenye Lou, Qing Xu, Stefanie Thust, Dorothee P. Auer, Zhen Chen +1 more
publishedcode/data similarity 0.70
Abstract · Accepted at the 37th British Machine Vision Conference (BMVC), 2026

Multi-modal brain tumor segmentation is essential for clinical diagnosis, radiotherapy planning, and longitudinal monitoring. While recent studies have achieved remarkable overall segmentation performance, they rely on overlap-based objectives that inherently favor large regions, causing sub-3 mm micro-lesions to be systematically suppressed during training. Moreover, existing pixel-level segmentation frameworks lack explicit instance-level modeling, leading to unreliable lesion counting that directly impacts clinical staging and therapeutic decisions. To address these challenges, we propose MicroBT, a unified multi-modal framework for micro brain tumor segmentation and counting. Our core insight is that a fundamental geometric property is inherently scale-invariant: regardless of size, each lesion possesses a well-defined centroid. Leveraging this, we first devise a centroid-anchored synergistic paradigm that utilizes predicted centroids as shared anchors to simultaneously condition dense segmentation and instance-level localization. To counteract the tumor size imbalance, we further devise a Volume-Calibrated Loss (VC-Loss) that adaptively amplifies the gradient contribution of micro-lesions, alongside a Size-Aware Curriculum Optimization (SACO) that stabilizes multi-task training by establishing global representations before progressively unlocking fine-grained localization. Extensive experiments demonstrate that MicroBT outperforms state-of-the-art methods, particularly on metastases, where micro-lesion ($\leq 3$ mm) localization precision improves by approximately 7% and counting estimation errors decrease by approximately 26%. The code is available at https://github.com/leonlou921/MicroBT.

0.49

CARD: Calibration via Agreement in Reverse Diffusion for Out-of-Domain MRI Segmentation

cs.CV ·2026-08-26 ·Jiaheng Dai, Weidong Guo, Qingbiao Li, Jie Xu, Yi Guo +2 more
similarity 0.69
Abstract · 10 pages, 5 figures

Probability calibration aligns model confidence with predictive accuracy, enabling clinicians to identify unreliable segmentation regions. This alignment breaks down under domain shift, where artifacts and unseen protocols produce confident errors. Existing post-hoc methods adapt the correction at test time, conditioning on predictive entropy, the logit pattern, or augmentation response, but each proxy is read from the terminal prediction, the very quantity that shift corrupts. This motivates reliability evidence beyond the terminal prediction, which categorical diffusion provides in two ways. First, a generative shape prior keeps a capacity-limited reference intact when appearance is corrupted, so its disagreement with the primary segmentor highlights primary-model errors. Second, every reverse step yields a class distribution, separating persistent disagreement from transient discrepancy. Aggregated over the trajectory, this disagreement correlates with Dice at 0.788, against 0.521 for a matched discriminative control. We therefore propose CARD (Calibration via Agreement in Reverse Diffusion), which maps the temporal aggregate of this disagreement to a temperature field applied per pixel across all classes, so that confidence changes while the segmentation does not. Across cardiac, prostate and brain MRI shifts, CARD lowers calibration error in 45 of 49 comparisons against the strongest baseline in each setting.

0.22

Uncertainty-Guided Handshake: Efficient Human-in-the-Loop Refinement for Surgical-Grade Glioma Segmentation

cs.CV ·2026-10-01 ·Samuel Hart, Ahmad Yahya, Ahmed Karam Eldaly
theory similarity 0.68
Abstract · 12 pages

While state-of-the-art automated models for medical image segmentation achieve high mean performance, they frequently suffer from localized, catastrophic failures that preclude safe clinical deployment, particularly in neuro-oncology. Interactive segmentation frameworks mitigate this by incorporating human oversight, but traditionally impose prohibitive cognitive and temporal workloads by requiring clinicians to manually search for errors. In this project, we present an efficient, Hybrid Structural-Aleatoric Human-in-the-Loop framework for glioma segmentation that bridges the gap between automated baseline performance and surgical-grade precision, achieving sub-2.0 mm HD95 on curated benchmarks while providing safety-net routing for structural failures across real-world clinical data. By extracting voxel-wise Test-Time Augmentation (TTA) uncertainty and applying hierarchical topological filtering, our method proactively isolates high-risk structural anomalies. We comprehensively evaluated our approach on a challenging out-of-distribution clinical stress-test cohort (N = 362). Operating under a simulated Human Oracle, the framework improved the Whole Tumor (WT) Dice score from 0.891 to 0.914 and reduced the 95th percentile Hausdorff Distance (HD95) from 5.82 mm to 4.76 mm. Critically for surgical safety, the system rescued severe boundary failures in the Tumor Core, reducing mean HD95 from 17.96 mm to 14.83 mm (improving absolute TC Dice to 0.356). These spatial rescues were achieved while demanding a median interactive workload of just 11.3% of the target volume. Acknowledging this as a simulated upper bound lacking real-world cognitive friction, the framework nevertheless demonstrates a highly Pareto-efficient pathway for safely deploying clinical AI.

0.15

Reliability analysis for BraTS-GoAT segmentation: a controlled robustness study of deep-ensemble uncertainty

cs.CV ·2026-08-13 ·Riya Deepak Shet, Chenxi Liang, Le Zhang
publishedbenchmarkcode/data similarity 0.68
Abstract · 12 pages, 4 figures, 2 tables. Conditionally accepted at MICCAI 2026 BraTS-GoAT challenge workshop. Code: https://github.com/riyashet-hds/br…

Deep networks segment brain tumours accurately in-distribution, but can fail silently when the input differs from their training data. That risk is central to clinical deployment and is the premise of the BraTS-GoAT generalizability task. We ask not only how well a model segments, but whether its uncertainty knows when it is wrong. On BraTS-GoAT (Task 3) we train a 5-fold cross-validated nnU-Net baseline (one held-out prediction per case) and a 3-seed deep ensemble. Both are evaluated for calibration and error detection on a per-region relevant mask, aggregated per case. In-distribution the 3-seed ensemble improves modestly over the already strong single model on the same held-out split, with the clearest gain in calibration. The separation appears under shift. In a controlled robustness study using graded synthetic corruptions as a proxy for acquisition shift, the single model's confidence stays flat while its accuracy and calibration degrade. Inter-member disagreement instead rises steeply, about a quarter to a third above the clean condition, several times the single model's response. On the official validation leaderboard the 5-fold ensemble of those folds attains whole-tumour Dice 0.87. The generalization gap is concentrated on the harder regions, with a characteristic failure of missing small, satellite lesions on unseen cohorts. In the synthetic study, disagreement among the 3-seed members is a more sensitive case-level indicator of acquisition shift than single-model confidence. Its per-voxel error localisation weakens as severity grows. The contribution is a rigorous, honest reliability comparison rather than a claim that any one uncertainty method dominates.

0.44

Parameter-Efficient Multimodal Brain Tumor Segmentation With Stage-Wise Shared Adapters

cs.CV ·2026-10-13 ·Milad Rostamian, Mohammadreza Mohammadi, Ender Konukoglu, Mohsen Soryani
similarity 0.67
Abstract

Different MRI modalities reveal different parts of a brain tumor. Segmentation models combine information from these modalities to outline tumor regions. Many models use a separate encoder for each modality. However, exchanging features among these encoders at several stages can increase model complexity. We introduce the Block-Wise Shared Adapter (BWSA), which combines compressed features from the modality encoders in a shared path and returns adapted features to each stream. In its fixed-blending form, BWSA adds the adapted features to the original features. Its trainable-gated variant (TG-BWSA) instead learns separate weights for the original and adapted features at each modality and encoder stage. We evaluate both variants on BraTS 2020 and BraTS 2023 with four segmentation backbones. On the official BraTS 2023 online validation set, BWSA increases average region-wise Dice by 1.3--7.6 percentage points relative to the corresponding unmodified backbones. TG-BWSA increases it by 2.8--7.7 points. Both variants add approximately 0.85--3.73% parameters and reduce average HD95 relative to the unmodified backbones.

0.34

Towards Trustworthy AI for Glioma Diagnosis: A Task-Aware Evaluation of Uncertainty Quantification

cs.CV cs.AI ·2026-09-30 ·Gonzalo Esteban Mosquera Rojas, Sebastian R. van der Voort, Carolin M. Pirkl, Sandeep Kaushik, Marion Smits +1 more
top venue similarity 0.66
Abstract · Accepted for publication at the Journal of Machine Learning for Biomedical Imaging (MELBA) https://melba-journal.org/2026:033

Uncertainty Quantification (UQ) is a key requirement for trustworthy AI in high-stakes medical image analysis. In this work, we evaluate UQ in a multi-task Deep Learning framework for MRI-based glioma diagnosis that performs tumor segmentation and predicts IDH mutation status, 1p/19q co-deletion status, and tumor grade. Monte Carlo Dropout (MCD) is used for a detailed task-aware analysis of predictive, aleatoric, and epistemic uncertainty. We assess MC sample convergence, calibration, error detection, selective prediction, associations with segmentation performance, and the effect of voxel-wise uncertainty aggregation on case-level reliability. We also compare MCD with Deep Ensembles (DE) and Monte Carlo Deep Ensembles (MCDE), examine interactions between segmentation quality and classification, and evaluate a composite trust score integrating segmentation and classification uncertainty. Across tasks, uncertainty estimates supported meaningful error detection, while calibration depended on the dropout rate, with moderate rates yielding the most reliable probabilities. Uncertainty decomposition provided task-dependent interpretability but did not consistently improve error detection over predictive uncertainty alone. DE and MCDE showed comparable operational utility, with no method consistently dominating across tasks and metrics. The composite trust score did not consistently outperform classification uncertainty for selective prediction. Overall, our results provide a task-aware evaluation strategy and practical guidance for the development of trustworthy AI for glioma diagnosis.

0.41

Generalizable Brain Tumor Segmentation with Self-Training and Tumor-Aware Deformations

cs.CV ·2026-09-02 ·Henrique Zan Grande, Jeovane Honorio Alves, Rayson Laroca, Andre Gustavo Hochuli
publishedcode/data similarity 0.65
Abstract · Accepted for presentation at the 2026 International Conference on Medical Image Computing and Computer Assisted Intervention (MICCAI) - BraT…

This work presents an approach to the Generalizability Across Tumors (BraTS-GoAT) task of the BraTS 2026 Challenge, which focuses on robust segmentation of brain tumor sub-regions across a heterogeneous patient population. The proposed method employs the nnU-Net framework with a large residual encoder architecture, integrating a semi-supervised learning technique with pseudo-labels generated from the unlabeled training data and a tumor-aware deformable augmentation that locally deforms the lesion while preserving the surrounding anatomy. We evaluate the individual contributions of each component, as well as their combination, using varying proportions of the most confident pseudo-labeled cases. The submitted configuration for the generalization task achieves Dice and NSD scores of 0.881 and 0.473 for Whole Tumor, 0.817 and 0.490 for Tumor Core, and 0.775 and 0.533 for Enhancing Tumor on the BraTS-GoAT validation set, improving over the labeled-only baselines across all tumor regions and confirming that self-training and the proposed augmentation are complementary. Our source code is publicly available at https://github.com/Henrique-zan/brats-goat-2026/.

0.43