CS Paper Radar

Beyond Discrimination: Evaluating Probability Calibration in Radiomics-Image Fusion for Renal Cell Carcinoma Classification

Yuan Liang, Morgan May, Abraham Campbell, Sourav Bhattacharjee, Simon Caton, Pierpaolo Dondio

eess.IV cs.AIcs.CVq-bio.QM ·submitted 2026-10-09 15:50 UTC · v1
top venue

Abstract

Reliable probability estimates are important for the clinical interpretation of machine-learning classifiers, yet radiomics--image fusion models for renal cell carcinoma (RCC) are commonly evaluated primarily by discrimination. Using 396 patients from the KiTS23 dataset, we evaluated whether adding radiomics to four image-model families improved probabilistic performance in addition to discrimination. Seventeen individual models and four probability-average ensembles were assessed using discrimination, probability calibration, and proper scoring measures. Across 12 matched image-only versus fusion comparisons, AUC and AP improved in all 12, while Brier score and negative log likelihood (NLL) improved in 11 of 12 and expected calibration error (ECE) in eight of 12. The 3D MedVAE gated-fusion model achieved the strongest overall individual-model profile. Probability averaging across concatenation, cross-attention, and gated fusion produced favourable point estimates across all five primary metrics relative to image-only models in all four families, although paired-bootstrap support was stronger for Brier score and NLL than for ECE. These findings show that radiomics--image fusion can improve probabilistic prediction quality beyond discrimination, while calibration behaviour varies across image architectures and fusion strategies. We show that our proposed probability-average ensemble models improve discrimination and calibration simultaneously across all architectures in the study.

Comment
12 pages. 1 figure. Accepted at the 2026 Irish Conference on Artificial Intelligence and Cognitive Science (AICS 2026). Proceedings forthcoming

Closest papers

Nearest neighbours by meaning across the whole index.

Complementary Roles of Radiomics and Foundation Representations in Renal Cell Carcinoma Classification: A Comparative Study of 2D and 3D CT Encodings

cs.CV cs.AI ·2026-09-22 ·Yuan Liang, Sourav Bhattacharjee, Abraham Campbell
published similarity 0.79
Abstract · Accepted at Medical Image Understanding and Analysis (MIUA 2026). 15 pages, 2 figures

Accurate preoperative subtype classification of renal cell carcinoma (RCC) from contrast-enhanced computed tomography remains clinically challenging. Radiomics provides structured tumour descriptors, whereas foundation representations offer transferable image features. However, it remains unclear whether radiomics still adds value beyond pretrained representations, and how 2D and 3D MedVAE encoders compare in this setting. We compared handcrafted radiomics, 2D MedVAE, 3D MedVAE, and their fusion for binary clear-cell RCC versus non-clear-cell RCC classification on KiTS23 under a unified preprocessing pipeline. Concatenation, cross-attention, and gated fusion were evaluated as representative integration strategies, and radiomics feature importance was analysed to support decision-centric interpretability. Fusion consistently improved discrimination over image-only MedVAE branches. The best overall performance was achieved by 3D gated fusion, with an AUC of 82.7\%, outperforming the best 2D fusion model (79.6%), the radiomics baseline (74.4%), and the single-modality MedVAE branches. Ablation analysis further showed clear gains of the full fusion model over both image-only and radiomics-only variants, indicating complementary contributions from radiomics and image representations. These findings suggest that radiomics remains relevant for RCC CT classification in the presence of foundation representations, and that its integration with MedVAE is more effective in the 3D setting. More broadly, the study supports a complementary role for radiomics and foundation representations in clinically meaningful imaging decision support.

0.33

Radiomics--Foundation Fusion for Interpretable RCC Classification: Internal Benchmarking and Exploratory External Transfer

cs.CV ·2026-09-22 ·Yuan Liang, Fangyijie Wang, Kathleen M. Curran, Guénolé Silvestre, Sourav Bhattacharjee +1 more
published similarity 0.78
Abstract · Accepted for an oral presentation at CaPTion 2026, a MICCAI 2026 workshop. 11 pages, 3 figures

Accurate preoperative subtype classification of renal cell carcinoma (RCC) from contrast-enhanced CT remains clinically challenging because clear cell RCC (ccRCC) and non-clear cell RCC often show overlapping imaging appearances. This study evaluates whether foundation representations reduce reliance on handcrafted radiomics, or whether radiomics remains complementary for interpretable tumour characterisation. We compared radiomics, conventional CNN features, MedicalNet-pretrained features, MedVAE representations, and fusion variants for binary ccRCC classification on KiTS23, reporting area under the receiver operating characteristic curve (AUC) with bootstrap confidence intervals and average precision (AP) as a complementary class-imbalance-sensitive metric. We further assessed branch-removal ablation, TCGA/AIMI external transfer, and interpretability using radiomics permutation importance and gate-level analysis. Internally, 3D MedVAE gated fusion achieved the best performance, with an AUC of 82.7% and AP of 92.2%. On the external TCGA cohort, the same model achieved an AUC of 79.5% and AP of 98.9%, although specificity remains uncertain because only two external non-ccRCC cases were available. Gate analysis showed a radiomics-dominant fusion regime, suggesting that foundation representations acted as case-dependent refinement signals rather than replacements for structured tumour descriptors. These findings support radiomics as a complementary and clinically interpretable component of CT-based RCC characterisation in the foundation-model era.

0.42

Beyond Gate Weights: Decision-Level Interpretation of Radiomics-Image Feature Fusion for RCC Classification

eess.IV cs.AIcs.CV ·2026-10-09 ·Yuan Liang, Sourav Bhattacharjee, Abraham Campbell
top venue similarity 0.78
Abstract · 12 pages, 1 figure. Accepted at the 2026 Irish Conference on Artificial Intelligence and Cognitive Science (AICS 2026). Proceedings forthcom…

Gate coefficients describe how a fusion layer weights intermediate features, but they do not necessarily reflect the magnitude of branch contributions at the classifier output. We investigate this distinction in a fixed 3D MedVAE--radiomics model for clear cell versus non-clear cell renal cell carcinoma classification from contrast-enhanced CT. Because the model uses a linear classification head, the binary decision logit can be decomposed exactly into a gated image term, a direct radiomics term, and a bias. We define effective radiomics dominance as the direct radiomics term's share of the summed absolute non-bias branch contributions and compare it with structural radiomics weighting. Internally, mean structural radiomics weighting was 0.823, whereas mean effective radiomics dominance was 0.148, with a modest case-wise association (\r{ho} = 0.290). The gated image term retained substantially stronger discriminative ranking information than the direct radiomics term. The same structural-to-effective discrepancy was observed in exploratory external evaluation. Branch-targeted permutation, integrated-gradient, and Shapley-style analyses further identified radiomics descriptors influencing the direct radiomics term. Because radiomics also generates the gate, the gated image term remains radiomics-dependent, so additive branch contribution should not be interpreted as total input influence. These findings show that structural gate weighting and decision-level branch contribution represent distinct aspects of gated feature fusion and should be interpreted separately.

0.28

Radiomics-Conditioned Modulation of RenalCLIP Features for Clear Cell Renal Cell Carcinoma Classification

cs.CV cs.AI ·2026-09-22 ·Yuan Liang, Sourav Bhattacharjee, Abraham Campbell
published similarity 0.76
Abstract · Accepted at the 7th International Conference on Medical Imaging and Computer-Aided Diagnosis (MICAD 2026). 10 pages, 2 figures

Radiomics provides quantitative descriptions of tumour appearance that may complement disease-specific foundation models in small labelled cohorts. We investigate this complementarity for computed tomography-based classification of clear cell renal cell carcinoma. Our framework uses radiomics to modulate RenalCLIP features through feature-wise linear modulation (FiLM), while retaining a direct radiomics contribution. Internal testing and external validation compare it with conventional fusion strategies and reference classifiers. The FiLM model achieves an area under the receiver operating characteristic curve (AUC) of 0.804 internally and 0.854 externally, with the highest mean AUC among the evaluated RenalCLIP fusion strategies in both cohorts. Pathway ablations examine the contributions of conditional modulation and the direct radiomics residual, while feature permutation highlights the role of tumour texture. These findings support radiomics as a useful complement to RenalCLIP in a small labelled cohort and identify FiLM as an effective approach to integrating their representations for robust renal tumour classification.

0.44

MSR-ABC: Complementary Feature Fusion for Clear Cell Renal Cell Carcinoma Classification

cs.CV ·2026-11-06 ·Yuan Liang, Sourav Bhattacharjee, Abraham Campbell
similarity 0.73
Abstract · Submitted to IEEE ISBI 2027

Clear cell renal cell carcinoma (ccRCC) classification from computed tomography (CT) may benefit from representations that capture different aspects of tumour phenotype. However, simply concatenating reconstruction-derived features, image--text embeddings, and radiomic descriptors may not fully exploit their complementary information. We propose MSR-ABC, a global--local framework integrating MedVAE, MedSigLIP, and radiomics. Spatially matched local image descriptors interact through cross-representation attention, while radiomic auxiliary supervision encourages the pooled local representation to retain quantitative tumour attributes. A gated residual mechanism integrates local information with global summaries. Area-aware pooling and visual and soft-text prompting complete the framework. We evaluate discrimination using a patient-level split of 396 KiTS23 cases and an external cohort of 111 TCGA/TCIA cases, reporting mean AUROC over three training seeds with 95% patient-bootstrap confidence intervals. MSR-ABC achieves mean AUROCs of 0.806 internally and 0.879 externally. Internally, it exceeds global MedVAE--radiomics and three-source concatenation by 3.35 and 3.61 AUROC percentage points, respectively. Removing any source lowers mean AUROC in both cohorts, with the largest decreases following radiomics removal. Individual removal of cross-representation attention, auxiliary supervision, or gated fusion also lowers internal mean AUROC. These findings are consistent with complementary contributions within the integrated architecture and support further investigation of structured representation fusion for non-invasive renal tumour characterisation.

0.13

Cross-Modal Contrastive Learning from Histopathology and CT for Automated Renal Cell Carcinoma Grading

cs.CV cs.AI ·2026-09-22 ·Amit Das, Tanmay Shukla, Naofumi Tomita, Faraz Farhadi, Jessica Sin +7 more
hot direction similarity 0.71
Abstract

Background: Clear cell renal cell carcinoma (ccRCC) exhibits substantial clinical heterogeneity, and accurate grade assessment is essential for risk stratification and treatment planning. However, conventional grading requires invasive tissue sampling. We developed RCC-Align, a cross-modal contrastive learning framework that leverages paired histopathology and computed tomography (CT) data during training to improve noninvasive CT-based ccRCC grade prediction. Methods: RCC-Align aligns paired whole-slide histopathology images (WSIs) and CT scans through contrastive cross-modal objectives, transferring grade-discriminative information from microscopic tissue morphology to macroscopic radiologic representations. The framework was trained and evaluated on paired TCGA and CPTAC cohorts using patient-level five-fold cross-validation. Performance for low- versus high-grade ccRCC classification was compared against CT-only baselines (DINOv2-Base and DINOv2-Finetuned) and a WSI-based reference model (GigaPath-Finetuned). Cross-modal alignment was assessed using cosine similarity analysis. Results: RCC-Align achieved an AUC of 0.601 (95% CI, 0.524-0.673) and AUPRC of 0.599 (95% CI, 0.541-0.676), outperforming DINOv2-Finetuned (AUC 0.545; AUPRC 0.543) with significantly improved low-grade prediction (p = 0.004). RCC-Align also demonstrated stronger paired WSI-CT embedding alignment compared with baselines. The WSI-based GigaPath reference achieved an AUC of 0.719. Conclusion: Pathology-guided contrastive learning improves CT-based ccRCC grading while requiring only CT at inference. This approach may complement tissue diagnosis when biopsy is unsafe, infeasible, or limited by intratumoral heterogeneity. Validation in larger, multi-institutional cohorts with external testing is needed before clinical translation.

0.25

Reliability-Aware Hybrid-K Ensemble Selection for Cervical Cytology Classification: Integrating Discrimination, Calibration, and Selective Prediction

eess.IV cs.AIcs.CV ·2026-09-01 ·Nisreen Albzour, Sarah S. Lam
similarity 0.67
Abstract

High classification accuracy alone is insufficient for clinical image analysis, where calibrated confidence and reliable uncertainty estimates are essential. This study proposes a reliability-aware Hybrid-K ensemble selection framework for multiclass cervical cytology classification using the SIPaKMeD dataset. Nine deep learning architectures were evaluated using a fixed stratified five-fold partition and three training seeds. After post-hoc temperature scaling, models were assessed using macro-F1, accuracy, AUROC, expected calibration error (ECE), worst-class ECE (WC-ECE), area under the risk-coverage curve (AURC), Brier score, and negative log-likelihood (NLL). Models were ranked using an equal-weight composite score, and Hybrid-K ensembles were formed from the top-ranked models using soft voting. Robustness was examined using 5,000 Dirichlet-sampled metric-weight vectors, leave-one-metric-out analysis, and corrected paired testing across 15 fold-by-seed evaluations. The final Hybrid-2 ensemble, comprising Swin-Tiny and TinyViT-5M, reduced AURC by 43%, NLL by 17%, and WC-ECE by 36% relative to the best individual model. It was selected in 96.8% of random weighting scenarios, remained unchanged across all leave-one-metric-out analyses, and improved the full composite score. However, per-metric gains were not statistically significant after Holm-Bonferroni correction (all adjusted p >= 0.168). Because post-hoc calibration did not use a fully independent calibration set, calibration-dependent results should be interpreted as exploratory internal estimates. Overall, the framework identified a compact ensemble robust to alternative metric weightings and improved reliability point estimates under internal validation on a single dataset.

0.23

When Slides Met Scans: Cross-Attention for Renal Cancer Prognosis

eess.IV cs.CV ·2026-10-26 ·Anusha Krishnamoorthy, Basudha Pal
similarity 0.66
Abstract

Histopathology and computed tomography (CT) provide complementary views of renal cancer. We connect these modalities through bidirectional cross-attention between 16 histology prototypes and up to 32 kidney-centered CT tokens from frozen foundation models. In 210 TCGA-KIRC patients with 46 disease-specific survival (DSS) events, 5-fold evaluation yielded a C-index of $0.760\pm0.081$ and 3-year AUROC of 0.773 (95\% CI 0.678--0.860), the highest averages among evaluated unimodal and fusion baselines. External testing in 180 CPTAC-CCRCC patients yielded DSS C-index of 0.629 with CT withheld. Attribution analysis linked predictions to image regions while exposing acquisition artifacts. These findings support further study of cross-scale fusion and independent multimodal validation.

0.13