CS Paper Radar

ScienceBuddy-PV: A Verifier-Governed Recursive Improvement Protocol for Panvascular Intervention Research

Lingsen You, Yujun Guo, Xinyu Zhong, Zijie Feng, Wentong Wang, Li Shen, Junbo Ge

cs.AI cs.CV ·submitted 2026-10-10 03:35 UTC · v1

Abstract

ScienceBuddy-PV adapts the ScienceBuddy recursive-in-recursive design to panvascular intervention research through a structured evidence ledger, device-vessel ontology, abstention contract and retained failure bank. Recursive harness optimization and outer-loop model learning, including reinforcement learning, are specified but not executed. We audit a fixed component, rather than the complete agent system, using separate ARCADE syntax and stenosis tasks (1,000 training, 200 validation and 300 test images per task). A shared task-masked convolutional model was trained once per representation setting; its parameters and the heuristic support gate were then held fixed, with the stenosis threshold selected on validation data. On the locked test sets, syntax Dice was 0.475 (95% CI 0.459-0.490) and stenosis Dice was 0.231 (95% CI 0.214-0.249). Stenosis pixel AUROC was 0.957 and AUPRC was 0.180 at prevalence 0.00975. The gate accepted 76.7% of stenosis-frame outputs versus 100% for a score-only comparator. In a constructed mask audit, it accepted 44.3% of reference candidates and rejected 55.7%, exposing the cost of abstention. Acceptance does not establish correctness or clinical safety. This public-data component audit makes support and abstention measurable and provides a reproducible protocol for future collaborative agent studies. It does not demonstrate recursive improvement, patient-level validity or clinical device recommendations.

Comment
17 pages, 17 figures, 19 references. Public-data component audit; recursive improvement is specified as a protocol and not experimentally demonstrated

Closest papers

Nearest neighbours by meaning across the whole index.

CARDEA: Auditable Reasoning Grounded in Spatial Evidence for End-to-End Coronary Angiography Interpretation

cs.CV ·2026-09-07 ·Jia-Jen Lee, Shih-Yen Hou, Kee Koon Ng, Wei-Chun Wang, Shih-Sheng Chang
code/data similarity 0.60
Abstract · 25 pages, 3 figures and 4 tables in the main text; supplementary appendix with 5 figures and 1 table. Model weights: https://huggingface.co/…

Invasive coronary angiography (CAG) is the gold standard for diagnosing coronary artery disease, but interpretation varies substantially among observers. Existing AI systems can improve consistency but lack auditable decision processes and are limited in comprehensive open-ended assessment, undermining clinician trust and clinical adoption readiness. We developed CARDEA, a unified large vision-language model that serves as the inference core of a CAG pipeline. It was trained solely on public datasets and closed-ended tasks in three stages: visual feature alignment, a self-distilled Chain-of-Box (CoB) cold start, and reinforcement learning with verifiable rewards (RLVR) with a CoB reward encouraging bounding-box use in the reasoning trace. We assessed its two study-level diagnoses, dominance classification and complexity assessment, against a dedicated classifier and two interventional cardiologists. Report generation was excluded from training and evaluated zero-shot across stages on an external cohort using vessel-severity macro-$F_1$. CARDEA trailed the classifier on in-distribution dominance but drew level under domain shift (accuracy, 0.91 [95% confidence interval (CI), 0.86 to 0.95]) and was comparable to the cardiologists on complexity assessment (accuracy, 0.90 [CI, 0.82 to 0.97]). Only RLVR improved zero-shot report generation, raising its vessel-severity macro-$F_1$ (0.686 [CI, 0.664 to 0.707]) above the untuned base model (0.513) and over twice the always-normal floor (0.312). CARDEA runs an end-to-end CAG pipeline from raw multi-view videos through keyframe selection to study-level diagnosis while exposing auditable spatial evidence behind its conclusions. RLVR on verifiable closed-ended tasks surfaced open-ended reporting ability that supervised imitation did not. Clinical use requires prospective validation against expert cardiologists.

0.43

BaT: Towards Self-Evolving Medical Research Agent with Stage Rubrics

cs.AI ·2026-08-17 ·Junqi Liu, Yufan He, Yexiao He, Pengfei Guo, Dong Yang +7 more
benchmark similarity 0.56
Abstract

Long-horizon agents are beginning to automate complete workflows that produce code, reports, and research artifacts. Medical imaging workflows are multi-stage and data-sensitive, while expert trajectories remain scarce and difficult to share. Structured benchmarks can localize failures through stage-level rubrics, but standard post-training discards these diagnostics before the next training round. We present Benchmark-as-Teacher (BaT), a recursive self-improvement system for agent post-training. BaT contains two linked components: the asynchronous Stage Bank data pipeline and BiCuRL (Bilevel Curriculum Reinforcement Learning), its self-improving post-training method. Stage Bank synthesizes content-isolated training states outside the policy-update loop. BiCuRL uses a fixed held-out evaluation to select the next stage curriculum, verifies rollouts with task rubrics, updates the policy with GRPO, and returns the candidate checkpoint to evaluation. On AutoMedBench-Lite, BaT-4B and BaT-9B more than double the Overall scores of their Qwen Instruct baselines. BaT-9B Agent reaches 79.6 Overall, exceeding Claude Opus 4.6 with Claude Code at 77.5.

0.41

BioMed-Agent-RL: A Meta Learning, All You Need for Biomedical Applications

cs.LG cs.AIcs.CV ·2026-08-22 ·Md Asaduzzaman Jabin, Zihao Wu, Tianming Liu
hot direction similarity 0.56
Abstract

The current progress of Clinical Vision Large Language Models (C-VLLMs) has substantially improved digital diagnostics, still these frameworks often endure lesion noises, modality misalignment, hallucination, and missed contextual grounding in complex clinical cases. Moreover, prevailing agent systems usually depend on static and non-adaptable pipelines and lack the versatility necessary for complex medical reasoning. To resolve these difficulties, we present BioMed-Agent-RL, a unified medical agent that incorporates adaptive orchestration, policy, and reward-based reinforcement learning (RL) models for biomedical applications. To ensure reliability, it invokes clinical context-aware preference optimization (CPO), direct preference optimization (DPO), and group relative policy optimization (GRPO) with dynamic entropy regulation. This pipeline utilizes a multimodal meta-learning approach that operates as a field-specific expert and human judgment synthesizer. The agent adaptively utilizes a set of model-level expertise, such as clinical grounding and reasoner, lesion segmenter, and field-specific synthesizer, across various clinical modalities (e.g., X-ray) by utilizing an iterative and adaptive RL approach. The agent learns to seriously synthesize misleading, conflicting vision cues and trust in inherent reasoning, while specialist advice is faulty. An intensive ablation study is conducted across multiple benchmarks, and the agent significantly outperforms existing state of the art models, such as GPT-5, attaining up to ~73% accuracy (gain of ~5%) over contemporary baselines. As a result, the framework suggests a new standard for building factual, reliable, robust, and expert-like intelligent agent systems for independent clinical reasoning.

0.23

Visual Harness Scales General VLMs to Medical Images

cs.CV ·2026-11-17 ·Shaowen Wan, Hanqi Jiang, Zihao Wu, Junhao Chen, Weihang You +4 more
similarity 0.56
Abstract

We show that an appropriate visual harness can substantially improve the performance of general vision-language models (VLMs) across diverse medical imaging tasks. We introduce VERA, a medical visual harness that equips general VLMs with interactive visual tools and systematic diagnostic evidence management. With VERA, general VLMs interactively explore medical images and progressively acquire diagnostic evidence, which is preserved in a lossless memory for subsequent retrieval and use. After submitting an initial answer, the VLM receives an assessment of potential omissions and the reliability of identified findings. This assessment guides further image inspection and measurement, followed by answer revision in an iterative agentic loop until sufficient evidence is obtained. Across 11 tasks and four imaging modalities, VERA improves performance on all tasks with Qwen3.8-27B, with notable gains in spleen measurement (63.3% to 98.3%), renal search (57.5% to 71.2%), and pulmonary nodule detection (0.0% to 28.2%). High-capability API-based VLMs achieve even higher performance with VERA. For example, GPT-6.1 Sol improves pulmonary nodule detection from 10.8% to 69.2% with VERA, demonstrating the complementary benefits of stronger model capabilities and an effective medical visual harness. Our results highlight the potential of visual harnesses as a new paradigm for scaling general VLMs to medical imaging tasks.

0.27

From Reward Signal to Visual Utility: A Controlled Audit of Medical VLM Post-Training

cs.CV cs.AI ·2026-09-25 ·Wang Jingxin
similarity 0.55
Abstract

Medical vision-language model (VLM) post-training is commonly evaluated through answer accuracy. We examine how changes in accuracy and training objectives relate to image-conditioned decisions in a controlled Qwen2.5-VL-3B study on PMC-VQA. We compare supervised fine-tuning (SFT) with low-rank adaptation (LoRA) restricted to the language model, expanded multimodal adaptation scopes, standard answer-only Group Relative Policy Optimization (GRPO), and a counterfactual evidence objective. On 2,000 clean-test questions, language model LoRA SFT changes correct-image accuracy by +1.10 percentage points (95% paired bootstrap CI:-0.85 to +3.05), while visual-benefit events decrease by 2.40 points and image sensitivity decreases by 5.60 points. Paired records reveal 155 acquired and 203 lost visual-benefit events. Broader adaptation yields lower correct-image accuracy than language-model LoRA SFT. Standard GRPO produces mixed-reward groups and parameter updates, with an uncertain clean test accuracy change. A generation audit reveals that canonical option scores can follow a different token path from generated answers. With scores taken along the greedy generation path, the evidence target improves on the training set; its gains over standard GRPO remain inconsistent on validation data at matched training doses. Sample-level analyses trace how evidence scores, decision margins, and generated answers change during post-training. This empirical and measurement audit identifies gaps between optimization activity, target acquisition, and useful held-out visual behavior.

0.23

TrustMed-RL: Long-Horizon Reinforcement Learning for Evidence-Grounded Clinical Diagnosis

cs.AI cs.MA ·2026-10-03 ·Wenxin Zhan, Yizheng Jiao, Haifeng Song, Shuai Xu, Chencheng Pan +2 more
similarity 0.55
Abstract

Medical language models can produce correct diagnoses despite incomplete investigations and unsupported reasoning. To support long-horizon, evidence-grounded diagnosis, we introduce \textbf{TrustMed-RL}. Built from PubMed rare-disease cases and over 24,000 manually annotated image panels, it integrates interviews, examinations, testing, specialist consultation, and literature search through state-dependent actions. Our 8B vision--language policy, trained with clinically adapted GiGPO and coverage-adjusted diagnostic rewards, achieves 37.1\% diagnostic accuracy on 2,500 evaluation cases, outperforming all evaluated open-weight baselines and improving over supervised fine-tuning by 12.4 percentage points.. When success additionally requires acquiring at least 50\% of supporting test evidence, TrustMed-RL achieves 32.5\%, exceeding GPT-4o by 6.8 percentage points. Furthermore, it surpasses all evaluated baselines on MTMedDialog and multiple larger 27--32B models on AgentClinic. In physician review of 200 diagnostically accepted test-set trajectories, 83.0\% receive evidential-grounding scores of 4--5 out of 5. Physicians' assessments suggest that these diagnostic trajectories are trustworthy and aligned with human diagnostic reasoning.

0.16

SimPT: An Automated Simulation Framework for Intervention-Based VLA Post-Training

cs.RO ·2026-10-21 ·Caicheng Wang, Zipeng Ye, Zhexuan Zhou, Zilong Huang, Xi Zhang +1 more
similarity 0.55
Abstract · 11 pages, 6 figures

Human-in-the-loop (HIL) post-training improves vision-language-action (VLA) policies through expert corrections, but costly human supervision and repeated real-robot evaluation limit algorithm exploration and development. We introduce SimPT (Simulation-based Post-Training), a simulation framework that automates intervention-based VLA post-training by integrating policy rollouts, corrective data collection, policy training, and standalone evaluation. To automatically determine intervention timing and recovery strategies, we develop an Agent-Compiled Progress Graph that tracks task progress using privileged simulator state and retains stable snapshots during policy execution. After a rollout fails, a CuRobo-based expert attempts recovery from these snapshots, starting at more advanced task stages and falling back to earlier ones as needed to generate corrective trajectories. We implement and compare four post-training methods, RECAP, HG-DAgger, DPO+SFT, and FlowPRO, across seven RoboTwin manipulation tasks. Relative to a fixed-interval snapshot baseline, the Progress Graph reduces recovery attempts by 75.0% and increases recovery success from 93.4% to 98.9%. Using SimPT, we develop RECAP-CF-LPF, a refinement of RECAP that combines cross-fitting and low-pass filtering of value predictions. This refinement increases the overall success rate from 76.50% to 79.36% in held-out simulation trials. In real-robot HIL post-training, it increases the success rate from 72% to 96% across 25 scenarios of an Ethernet cable-insertion task. These results demonstrate the utility of SimPT for exploring and developing VLA post-training algorithms.

0.19

From Tool State to Scientific Action: Auditing Decision Provenance in Biomedical Research Agents

cs.AI cs.LGq-bio.QM ·2026-11-01 ·Xingyu Yi, Xinya Zhang, Yunshen Zhou, Haoyu Bao
published similarity 0.55
Abstract · Accepted at NeurIPS 2026 AgenticLS Workshop; adds one experiment

A scientific agent can give the same verdict while reading and citing different evidence. BioAgent-DF tests this separation using paired reference and candidate values saved at the same scientific computation site. It restores or transplants those values at their original coordinates, then runs the agent on healthy hardware. Across eight SciFact batches, Qwen3.5-4B shows repeatable citation changes in three capture-claim combinations, and Gemma 3 4B IT shows repeatable read and citation changes in four. These seven combinations cover two claims. Full restoration recovers the reference evidence sets while verdicts remain unchanged. Verdict changes observed under the baseline prompt did not recur under the explicit-example prompt. Complementary tool and optimizer experiments distinguish recovery of numerical state, recovery of ranked lists, and restoration of an agent's visible history. These results show that an audit should track both the evidence an agent uses and its final answer. In hERG cardiac-safety assay allocation, silent numerical faults changed testing decisions while the fixed-budget shortlist kept the same number of compounds labeled as blockers. After the agent had used faulty values, restoring its earlier execution state and supplying certified scores recovered all 39 changed decisions, whereas replacing the prediction file recovered none; no incorrect action was committed. A streaming implementation of the arithmetic checks reduced the total time for forward execution and verification by 42.4% relative to the original FP64 implementation, with identical flags and recovery outputs.

0.38