CS Paper Radar

ClinEdge: An Expert-Graded Benchmark of Real Patient Edge Cases Where Frontier Multimodal Models Fail

Anurag Sharma, Aditya Sharma, Sapna Baalwan

cs.AI ·submitted 2026-10-11 00:17 UTC · v1
benchmark

Abstract

Most benchmarks for large language models in medicine are built from licensing examinations and theoretical questions. The few that draw on real clinical data do so only in part, and rarely require a model to read a patient's own imaging. ClinEdge addresses this gap with 32 real, de-identified patient cases from active clinical practice, each evaluated across seven frontier systems for a total of 224 expert-graded evaluations. Each case pairs primary imaging with a short vignette, contains a feature known to defeat pattern-matched reasoning, and is scored against the patient's documented clinical course. The suite is built for depth rather than volume. Grading followed a two-stage expert process. First, a senior orthopaedic surgeon graded all 224 responses on a weighted rubric and a pass-or-fail verdict. Second, a panel of nineteen physicians, largely senior specialists at teaching medical colleges, independently reviewed every case and every one of the 224 grades. All seven production systems were evaluated through their public interfaces, and all 224 conversations are preserved as replayable links. Performance was poor across all systems, and the failures were shared: different vendors missed the same findings and converged on the same wrong plans. From the experts' notes we catalogue 18 recurring failure modes in five families. The models stop reading an image at the first finding. They give generic plans and lean toward over-treatment. They trust a misleading history over correct imaging. Their answers vary across systems and runs, and change with question format. Failing answers were delivered fluently and without any expressed uncertainty. Four cases are released in full; the remaining 28 are held out, and we invite frontier AI labs and healthcare AI companies to evaluate their models against them (research@futrbridge.com)

Comment
14 pages, 5 figures. 32 real, de-identified clinical cases; 224 expert-graded evaluations across seven frontier multimodal AI systems

Closest papers

Nearest neighbours by meaning across the whole index.

MedRoundsQA: A Persona and Difficulty Aware Evaluation for Multi-Turn Medical Consultations

cs.AI ·2026-09-11 ·Youssef Mohamed, Ahmed Heakl, Qinrong Cui, Junhong Liang, Rafiq Ali +11 more
top venuebenchmark similarity 0.64
Abstract

Medical benchmarks are dominated by single-turn, multiple-choice clinical cases that poorly reflect real consultations. Practically, clinicians elicit evidence interactively and patient communication varies widely. We introduce MedRoundsQA, a multi-turn diagnostic benchmark derived from 1,387 board-exam cases across 17 specialties. Each case is converted into a structured 24-slot clinical record, and then instantiated as controlled doctor-patient dual-agent dialogues under varying patient personas, with the underlying clinical content held fixed. We further classify cases by difficulty using model-based uncertainty to enable easy-to-hard analysis. Evaluations of fifteen LLM doctor agents show that (i) moving from a single-turn diagnosis on the standardized records to multi-turn consultations causes large degradations of roughly 13-39 points; (ii) more turns reliably improves question relevance, but diagnostic accuracy exhibits diminishing returns and typically plateaus after 6-12 turns; and (iii) patient persona differences can shift diagnosis accuracy by about 7-8 points (lowest to highest education), highlighting equity risks that single-turn benchmarks miss.

0.40

An evidence-traceable benchmark of clinical reasoning in large language models

cs.CL ·2026-11-10 ·Zhiqun Zhao, Xiaodong Yang, Bruce Gu, Ming Li, Yi Fu +11 more
benchmark similarity 0.64
Abstract · 25 pages, 8 figures, 4 tables. Zhiqun Zhao, Xiaodong Yang and Bruce Gu contributed equally. Corresponding authors: Zheng Wang, Haiquan Lu an…

Benchmark scores for medical large language models (LLMs) are difficult to interpret when scoring criteria cannot be traced to clinical evidence. Here we developed Med Evidence Bench (MEB; https://www.medevidencebench.org.cn/), comprising 1,536 physician-constructed items across three levels: guideline knowledge, standardized clinical scenarios and real-world laboratory scenarios. Each criterion stating a medical claim is linked to a versioned source-text span. Across ten LLMs, the Evidence Trace Score (ETS) was 0.975-0.997 for guideline knowledge, 0.292-0.658 for standardized scenarios and 0.182-0.447 for real-world scenarios, and rankings varied across levels. For real-world scenarios, scores for identifying clinical information (mean, 0.770) exceeded those for matching evidence (0.165) or formulating recommendations (0.160). On 1,296 criterion-level judgments, automated grading agreed with the majority vote of three physicians (macro-F1, 0.930; 95% confidence interval, 0.915-0.945), although agreement was lower for evidence application. These findings from Chinese-language materials indicate that guideline recall does not ensure patient-specific evidence use and do not establish clinical effectiveness.

0.25

MedReaMM: Evaluating Large Multimodal Models on Expert-Level Clinical Diagnostic Synthesis

cs.CV ·2026-08-23 ·Lai Wei, Yuchao Chen, Zhenbiao Cao, Xiaojin Zhang, Zhongyu Wei +3 more
top venuebenchmark similarity 0.63
Abstract

The application of Large Language Models (LLMs) to diagnostic decision-making has garnered growing interest. However, existing benchmarks largely focus on textual reasoning or isolated visual question-answering (VQA) tasks, lacking holistic integration of clinical narratives and medical imaging, and thus failing to assess the multimodal diagnostic synthesis capability central to expert clinical judgment. To bridge this gap, we introduce MedReaMM, a benchmark specifically designed to evaluate models' ability to synthesize heterogeneous clinical evidence consisting of detailed patient histories alongside multiple medical images into accurate differential diagnoses under a complete-information paradigm. Constructed from case reports sourced from top-tier medical journals and curated clinical case databases, MedReaMM comprises 625 expert-validated cases with an average of 2.79 medical images per case and a total of 1,042 standardized diagnoses annotated with ICD-11 codes. These cases predominantly represent rare, atypical, or multi-system presentations that demand expert-level evidence integration beyond routine pattern recognition. We evaluate 23 Large Multimodal Models (LMMs) and find that most achieve diagnostic accuracy scores below 50%, underscoring a substantial gap in multimodal diagnostic synthesis capability. Further analysis reveals that medical knowledge proficiency, medical image understanding, and evidence integration are all highly correlated with diagnostic performance.

0.40

Are We Grading Properly? Understanding Failure Modes in Medical Benchmarks

cs.CL cs.LG ·2026-09-10 ·Prithvi Dixit, Pedram Hosseini
similarity 0.62
Abstract

Medical evaluation is shifting from static option-based questioning to realistic clinical scenarios with open-ended output modes. Grading these at scale naively, however, is expensive, and rubric-based evaluation has become the dominant scalable alternative. We ask what happens when the rubrics themselves are not airtight, and whether such flaws can be detected and corrected. We apply RIFT, a global rubric failure taxonomy, to two clinical benchmarks (HealthBench Professional and LiveMedBench), and find failure modes are meaningful: on HealthBench Professional an LLM judge flags 29.6% of criteria as non-atomic and 65.4% as misaligned/rigid. Then, we show that these flaws are meaningful and not simply cosmetic. As an example, rewriting bundled criteria of the form "at least one of / all of the following" as equally weighted children and regrading identical responses shifts scores by up to 15.9 percentage points on affected conversations, with disjunctive bundles inflating scores and conjunctive bundles deflating them. We also find that RIFT generally under-detects bundling on clinical rubrics, flagging 3.3% of LiveMedBench criteria as non-atomic where surface-form analysis finds structure in 25.8%.

0.33

Would an LLM Match into a Residency? Uncertainty, Reasoning and Image Use of Open Language Models on the Spanish MIR Examination

cs.CL cs.AIcs.CYcs.LG ·2026-10-22 ·Miguel Fernandez-de-Retana, Unai Zulaika, Ruben Sanchez-Corcuera, Aritz Bilbao-Jayo, Aitor Almeida
hot direction similarity 0.62
Abstract · 13 pages, 8 figures

Accuracy on medical examinations is common evidence offered for the clinical use of language models, yet a health system that intends to run an open model on its own hardware needs to know considerably more: whether the model recognizes when it is likely to be wrong, whether medical fine-tuning improves this ability, whether its correct answers rest on sound clinical reasoning, or whether it actually uses the images it is given. We examine these questions for four open models of 8 to 27 billion parameters on the Spanish MIR residency examination, scoring 1,552 questions from eight editions under the exam's own rules. Answering every question, the three larger models would rank among roughly the first 600 to 3,000 candidates, with 41 to 43 specialties still open to them. Abstention, however, never pays, because even their least confident answers are right more often than the 25% break-even. Medical fine-tuning reduced overconfidence at the cost of accuracy, without improving how well confidence separates right from wrong answers. Moreover, 13-38% of correct answers rejected a distractor for a clinically unsound reason that confidence did not reflect, and removing or swapping the provided contextual images left accuracy unchanged.

0.34

The Value of System 1 Models in Medicine

cs.LG ·2026-10-22 ·Xiufeng Yang, Konstantinos Vrettos, Zeineb Ben Chaaben, Fabian Drexel, Jannik Lübberstedt +15 more
similarity 0.62
Abstract · 27 pages, 6 figures; includes Supplementary Appendix (3 figures, 5 tables)

Many clinical decisions are a choice among a few fixed options, taken quickly and in large numbers. Such decisions also need an uncertainty estimate to know when to defer to a clinician. Generative language models answer slowly in free text and state their confidence poorly. In contrast, System 1 models answer zero-shot with a probability for each answer. However, their performance across clinical tasks is unknown. Four System 1 models, two proprietary and two with open weights, were evaluated zero-shot on 86 public tasks from 14 clinical domains in 20 languages, spanning examination questions and medical imaging. Tasks were assigned to six capability tiers before analysis. The primary outcome was the area under the receiver-operating-characteristic curve (AUROC). Secondary outcomes included calibration, language effects and comparisons with published results and generative models. Across 179,111 cases, the mean AUROC of the best model per task was 0.94 for medical knowledge, 0.93 for text understanding, 0.83 for clinical judgement from text, 0.89 for image perception, 0.84 for 2D image findings and 0.69 for volumetric findings. Imaging tasks scored 0.09 (95% CI, 0.06 to 0.11) lower than text tasks (P < 0.001). The best model matched or exceeded the best published result on 13 of 26 text tasks and on 8 of 35 imaging tasks. Triage nurses outperformed the best model (accuracy, 0.85 vs. 0.56). One decision took 0.34 to 0.44 seconds and 24 to 81 joules on open-weight models run locally. Accuracy on identical questions fell by up to 39 percentage points from English to Yoruba. Generative models of the same family were 11 to 76 times slower, with 3 to 5 percentage points higher balanced accuracy. System 1 models decide quickly, cheaply and with usable confidence when the answer is stated in a text or recalled from medical knowledge, but not when it must be judged or read from an image.

0.52

ROUNDS: Source-Framed Diagnostic Revision after Multi-Turn Clinical Evidence

cs.CL cs.AI ·2026-11-14 ·Jinrui Fang, Runhan Chen, Yining Wu, Jiawei Xu, Xu Yang +4 more
top venuebenchmark similarity 0.61
Abstract · Accepted at Machine Learning for Health (ML4H) 2026, Proceedings Track; to appear in Proceedings of Machine Learning Research (PMLR). 17 pag…

Large language models (LLMs) achieve high scores on medical benchmarks, but does this performance translate into reliable diagnosis as a conversation unfolds? In diagnostic conversations, users can provide clinical findings across multiple turns, ask for a diagnosis without supplying answer options, and introduce opinions from others. Models must therefore form diagnoses from the available evidence and decide how to respond to subsequent advice. We introduce ROUNDS, a framework that evaluates these abilities after a fixed sequence of clinical evidence delivered over multiple turns. ROUNDS compares diagnosis with and without answer options, presents the same incorrect diagnosis under clinician and lay framing, and varies support for competing diagnoses in written five-clinician panels. Across seven models and 1,035 cases from five datasets, average accuracy was 76.9% with answer options and 57.0% without them. Clinician-framed misleading advice produced lower final accuracy than lay-framed advice in every model, with differences of 4.6 to 38.2 percentage points. Initially correct diagnoses more often became incorrect answers than abstentions, and many adopted the suggested disease. Conversely, accuracy increased as more panel members supported the correct diagnosis, including when the majority opinion remained unchanged. These findings reveal a gap between medical benchmark performance and reliable diagnosis in conversation: models respond to external opinions, but remain vulnerable to abandoning correct diagnoses without new clinical evidence.

0.34

Decision language models as affordable and rapid alternatives to LLM judges of clinical generative AI

cs.AI ·2026-10-20 ·Rotem Gershon, Seffi Cohen, Dean Ariel, Havatzelet Bilavsky-Yarden, Amiel Sberro +9 more
benchmark similarity 0.60
Abstract

Automated judges of clinical artificial intelligence (AI) outputs are necessary, but large language model (LLM) judges are costly and slow at scale. We compared Jev, a decision language model that returns structured judgments, with frontier and open-weight LLM judges in four use cases. On 118 pediatric answers, Jev's agreement with physicians' ordinal quality ratings (Gwet's AC2 0.50; expected score 0.53) matched or exceeded that of seven of 12 LLM judges, including frontier models, Claude Opus 5.5 (0.49) and GPT-6 (0.38). On physician-graded binary HealthBench criteria, Jev matched or exceeded four of six LLM judges. On MedHELM's open-ended tasks, Jev's agreement with a three-LLM jury approached or exceeded the jurors' internal agreement. On HealthBench Professional, Jev matched the benchmark's reference judge, GPT-5.4, on 91% of criteria (other judges, 91-93%). Frontier judges cost 73-294 times more than Jev and took 7-57 times longer. Jev may enable efficient clinical AI evaluation at scale.

0.12