Riemannian Suppression of Cross-Session Identity Leakage in Motor-Imagery EEG

Sheikh Samit Muhaimin, Aarthy Nagarajan

cs.CR ·submitted 2026-10-11 13:50 UTC · v1

Abstract

Electroencephalography (EEG) recorded for motor-imagery (MI) brain-computer interfaces (BCIs) carries subject-identifying structure that persists across sessions, allowing separately released sessions from the same person to be linked. Existing EEG identity protections use learned or additive perturbations and operate on representations other than the covariance geometry underlying MI pipelines. We ask whether cross-session identity leakage can be suppressed directly in this covariance representation without learning a privacy model. We introduce a Riemannian transform that equalizes two subject-conditioned geometric statistics: the Riemannian mean covariance and the tangent-space scatter around it, with two optional band-specific refinements. Ablations show that mean alignment and scatter whitening carry nearly all of the suppression, while the optional stages contribute small, dataset-dependent refinements. Across two public datasets and five attackers spanning four covariance-space representations, the worst attacker falls from 90.8% to 15.6% on BCI Competition IV-2a and from 90.8% to 9.9% on OpenBMI, at a cost of 7.0 and 2.1 points of MI decoding accuracy relative to the 8-30 Hz input, and no aggregation rule exceeds chance by more than two points at any batch size. The transform requires no learned privacy model, surrogate network, or gradient-based training, and is fitted on one session and applied unchanged to a held-out later session.

Comment
23 pages, 5 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Personalised federated learning for Riemannian and Euclidean EEG decoding

cs.LG stat.ML ·2026-09-24 ·Thibault Pautrel, Florent Bouchard, Ammar Mian, Guillaume Ginolhac
hot direction similarity 0.68
Abstract

Federated learning (FL) lets EEG decoders learn from recordings of several subjects without pooling them. We consider two light EEG decoders, the Riemannian SPDNet and the Euclidean EEGNet. Both split into a trunk, which builds a latent representation, and a head, which classifies it. Inter-subject variability, however, makes a single shared FL model a poor fit for each subject. Personalised FL addresses this: all subjects learn a common trunk, and each subject keeps its own head. We adapt it for SPDNet and study its effects against standard FL and centralised training, with EEGNet as a Euclidean baseline. Experiments cover three motor-imagery datasets that span diverse regimes in channels, subjects and classes. We observe that personalised SPDNet reaches higher accuracy than both standard FL and centralised training, while converging in fewer rounds and communicating fewer parameters than standard FL. It also outperforms every EEGNet configuration on two of the three datasets, although centralised EEGNet outperforms centralised SPDNet.

0.49

NeuroPriv: Adversarial Representation Learning for Privacy in Wearable EEG Systems

cs.CR cs.HCcs.LG ·2026-08-31 ·Sarmistha Sarna Gomasta, Bhawana Chhaglani, Prashant Shenoy
similarity 0.66
Abstract

Wearable EEG systems may expose sensitive information beyond their intended health function, creating substantial risks to neuroprivacy. In this work, we show that commonly used EEG features can reveal participant identity and demographic attributes in addition to supporting the intended cognitive task. Wearable EEG is increasingly being explored for cognitive monitoring, neurological assessment, and longitudinal digital-health applications, yet many systems assume that transmitting compact spectral or spatial features instead of raw EEG provides sufficient privacy protection. Using EEGMAT as a motivating case study, we find that compact EEG features achieve a balanced accuracy of 0.788 for cognitive-state classification while enabling gender, age, and subject-identity inference with balanced accuracies of 0.858, 0.789, and 0.692, respectively. We further show that privacy-aware representation learning preserves task performance at 0.781 while reducing these inference accuracies to 0.563, 0.467, and 0.206. These findings motivate purpose-limited representations and explicit privacy auditing in wearable neurohealth systems.

0.42

Differentially Private EEG Feature Anonymization: A Privacy-Utility Case Study in Clinical Neurophysiology

cs.CR cs.LGeess.SP ·2026-09-10 ·Noman Sadiq, Mohsen Toorani
similarity 0.65
Abstract · 27 pages, 11 figures, 7 tables

Clinical electroencephalography (EEG) data are valuable for healthcare research and for developing artificial intelligence (AI)-based clinical decision-support systems, but EEG recordings and derived features may contain sensitive patient-specific information. This creates privacy risks when data are reused, analyzed, or shared across clinical and research environments. Conventional anonymization methods are often insufficient for high-dimensional biomedical signals, since removing direct identifiers does not necessarily prevent re-identification, linkage, or inference risks. At the same time, strong privacy protection may distort clinically relevant signal characteristics and reduce data utility. This paper studies subject-level differential privacy for protecting clinical EEG-derived feature representations using Gaussian and Laplace perturbations. The proposed framework considers three deployment scenarios: client-side anonymization, centralized server-side anonymization, and decentralized local training. Following EEG preprocessing and feature extraction, Gaussian and Laplace perturbations are applied to the resulting patient-level EEG feature representations. The Laplace experiments evaluate the implemented noise scales, while the scales required for formal full-vector calibration are derived separately. The effects of both perturbations are assessed using statistical utility measures and a downstream machine-learning-based utility check. The results show that differentially private perturbation can be integrated into EEG processing workflows, but the selected mechanism, privacy parameters, and sensitivity calibration strongly influence data utility. The study highlights the practical privacy-utility trade-off in DP-based EEG feature anonymization and the challenges of preserving downstream utility in small and imbalanced clinical EEG datasets.

0.12

Alignment De-Identifies Without Aligning: A Congruence-Invariant Relational Gap in Cross-Subject Neural Representations

cs.HC q-bio.NC ·2026-11-11 ·Anna Notaro, Letizia Rossato, Sadasivan Puthusserypady
published similarity 0.64
Abstract · 23 pages (12 pages main text and references, 11 pages appendix), 2 figures. Accepted at NeurIPS 2026, NeurReps Workshop

In brain-computer interfaces, inter-subject variability remains a major challenge that limits decoding performance across users. Subject-wise alignment is widely used to improve cross-subject transfer of neural decoders, yet it is typically evaluated only through decoding accuracy, which cannot determine whether aligned representations share greater task-related structure. We therefore distinguish two questions that accuracy conflates: whether alignment removes subject-specific information and whether it makes the relational organization of task conditions more similar across individuals. Using three motor imagery-EEG cohorts, trials are represented as covariance matrices and aligned by recentering each subject's mean covariance to a common reference. Subject-specific information is quantified with a subject-identification probe, whereas relational structure is assessed using representational dissimilarity matrices (RDMs) computed from condition means with the affine-invariant Riemannian distance. We show that recentering leaves this distance, and therefore the resulting RDMs, unchanged. Consistent with this result, recentering reduces subject identification accuracy from 0.96 to chance level across all cohorts, while altering RDMs only at numerical precision. Cross-subject agreement in relational structure is significantly above zero but below the estimator's lower noise ceiling. Introducing an explicit similarity regularizer during training also fails to increase held-out agreement: the apparent reduction in between-subject differences is explained by a decline in the reliability ceiling rather than improved alignment. These findings show that eliminating subject identity is not equivalent to aligning relational geometry. More broadly, alignment claims must be interpreted relative to the invariances of both the distance and the statistic used to evaluate them.

0.33

FRIST: FMRI Representation Informed Shared-space Training Improves EEG-only Individual-Finger BCI Decoding

cs.LG eess.SP ·2026-09-11 ·Jintao Zhang, Yidan Ding, Joshua Kosnoff, Maxim Karrenbach, Hanwen Wang +1 more
similarity 0.64
Abstract

Finger-level motor decoding is important for naturalistic brain-computer interface (BCI) control, yet individual-finger decoding from scalp electroencephalography (EEG) remains challenging because finger representations are spatially close in the sensorimotor cortex and blurred by volume conduction. Leveraging the high spatial resolution of functional MRI (fMRI), we introduce fMRI Representation-Informed Shared-Space Training (FRIST), a two-stage EEG decoding framework that first learns fMRI-informed spectral projections from simultaneous EEG-fMRI recordings and then uses fMRI-derived class geometry to guide residual refinement of EEG predictions. FRIST transfers information across recordings through shared finger labels without requiring paired trials and uses only EEG at inference. We evaluated 12 able-bodied participants during movement execution (ME) and motor imagery (MI) under two-class and three-class chronological session-held-out decoding simulating the online scenario. Using EEGNet as the EEG feature extractor, FRIST increased group average accuracy from 66.93% to 74.53% for two-class ME, from 44.83% to 56.58% for three-class ME, from 80.78% to 85.63% for two-class MI, and from 60.93% to 69.90% for three-class MI compared with the EEG-only EEGNet baseline. FRIST is also shown to improve EEG-only decoding when the target participant's own fMRI data were unavailable. FRIST also generalized across multiple EEG decoding backbones, reaching 87.40% in two-class MI and 72.54% in three-class MI with EEG Conformer as the EEG feature extractor. These findings indicate that fMRI provide useful spatial constraints for EEG representation learning. FRIST improves noninvasive EEG-based finger-level BCI decoding, offering a multimodal strategy for integrating the spatial specificity of fMRI with real-time applicability of EEG.

0.46

Cross-subject decoding of imagined speech from scalp EEG: a leakage-controlled evaluation on three public corpora

eess.SP cs.LGq-bio.NC ·2026-10-14 ·Blessing Isoyiza Adeika, Onyema Osuagwu
similarity 0.62
Abstract · 23 pages, 5 figures, 10 tables plus supplementary tables. To be submitted to Journal of Neural Engineering

Objective. A decoder of imagined speech that works for a new user without calibration would make a non-invasive speech interface practical. We tested whether imagined-speech content recorded with scalp electroencephalography (EEG) transfers across people, and examined why accuracy within a single person remains low. Approach. We analyzed three public corpora, ds003626, KaraOne and Track 3 of the 2020 International Brain-Computer Interface Competition, under a protocol that enforces split integrity by assertion and reports exact binomial thresholds, group tests and bootstrap confidence intervals. We trained decoders on each participant and tested them on every other, compared representational geometry across participants without a classifier, applied subject-level alignment, and tested five explanations for the within-subject ceiling. Main results. Across 482 ordered pairs of participants, no pair survived correction for multiple comparisons; mean pair-transfer accuracy lay within 0.006 of chance on every corpus, while every within-subject reference lay above it. Imagery against pre-stimulus rest generalized at about 0.61 after artifact and elapsed-time controls, but its decoder labelled the interval preceding imagery as imagery as often as imagery itself, so the contrast reflects a post-stimulus state, not imagery. Within subject, only the competition corpus decoded above threshold for every participant (0.3147; chance 0.200); syllable count explained little of this, but its frequency profile failed an artifact audit. Significance. In these corpora, imagined-speech content did not transfer between people through any representation we examined. Trial count per class was the only variable that ordered the corpora, which favors larger single-condition datasets over further model development.

0.34

SPDAlign: Interpretable Riemannian Alignment for EEG Forward Modeling Shifts

cs.LG ·2026-10-05 ·Shanglin Li, Shiwen Chu, Okan Koç, Chenyu Liu, Qibin Zhao +3 more
similarity 0.61
Abstract

Electroencephalography (EEG) based brain-computer interfaces enable direct brain-to-device communication for applications such as rehabilitation and communication. However, their practical utility is often limited as the non-stationary nature of the EEG data introduces distribution shifts across domains (e.g., sessions and subjects). Adapting machine learning models to be invariant to these shifts in an unsupervised way, without using costly labeled calibration data, would drastically improve the utility of EEG data. In this work, we use a classic generative model of EEG to study distribution shifts introduced by the domain-specific forward process, which is associated with factors such as head geometry. We theoretically show that such distribution shifts can be recovered solely through linear transformations on the Symmetric Positive Definite manifold. Building on this insight, we propose SPDAlign, an interpretable framework for promoting domain-invariant EEG learning. SPDAlign first aligns the domain-specific means and corrects global rotations across domains using a recent optimal transport technique called Wasserstein Procrustes. We systematically study the proposed approach through simulations and demonstrate its competitive performance on extensive public EEG datasets. Additionally, SPDAlign is a globally linear framework and is intrinsically interpretable, so that the framework can identify frequency ranges of interest, determine the spatial patterns reflecting source-sensor relationships, and address cross-subject variability.

0.24

Representational and Functional Robustness to Electrode Montages in EEG Foundation Models

cs.LG ·2026-09-28 ·Jakob Steglich, Justus Meyer zu Bexten, Shakiba Moradi, Laure Ciernik, Simon M. Hofmann +1 more
similarity 0.60
Abstract · 17 pages, 9 figures

EEG foundation models (EEG-FMs) are intended to generalize across different datasets by learning representations that, ideally, are invariant to dataset-specific EEG configurations such as electrode montages. However, EEG-FMs that accept different montages as input do not guarantee that representations and predictions remain stable across different electrode configurations, especially outside the training setting. In this work, we investigate the effects of different electrode montages through a joint functional and representational analysis of four EEG foundation models selected to span distinct montage-handling designs. We evaluate embeddings on cross-subject resting-state eyes-open/closed and within-subject motor-imagery classification under spatially informed channel reduction. Functional robustness is tested through the generalizability of linear probes across channel counts, while representational robustness is assessed through within-subject similarity and preservation of between-subject geometry. The four models show distinct robustness profiles, and the two axes dissociate: large changes in embedding similarity need not come with comparable probe degradation, and stable embeddings can still lose downstream performance. Comparing two readouts of the same encoder further shows that aggregation, not the encoder alone, determines functional robustness: pooling into anatomically aligned regions degrades less than a learned global readout, despite being montage-invariant by construction. Montage robustness is therefore a joint property of the encoder and its aggregation, and characterizing it requires both a representational and a functional axis. Input compatibility alone is evidence for neither.

0.44