CS Paper Radar

From Sampled Evidence to Radiology Reports: Objectives, Constraints, and Realization

Kun Zhao, Haoteng Tang, Chenghua Lin, Liang Zhan

cs.CL ·submitted 2026-10-12 19:19 UTC · v1
benchmark

Abstract

Sampling multiple reports creates an inference problem: how should sampled evidence be converted into a final decision, and does a better structured decision yield a better report? We study these questions through a framework that separates the decision signal, scoring objective, and feasible decision set, followed by text realization. On MIMIC-CXR and IU-Xray, controlled comparisons across 13 generator configurations per benchmark under grouped development/test evaluation reveal three findings. First, changing the objective under fixed evidence and rule capacity changes predictions and their held-out metric trade-offs. Second, relaxing candidate constraints has objective-dependent effects under shared signals and frozen scores. Diagnostics connect the IU macro-oriented assertion increase to near-zero label thresholds and show that limited candidate coverage coexists with selection headroom. Third, a controlled realization study with SFT-Qwen3-VL-8B shows that decision-level gains can be attenuated, amplified, or reversed. Change decomposition reveals that realization can remove incorrect assertions while losing correct findings, so target fidelity and reference accuracy need not improve together. Finding gains also do not consistently improve reference-based report quality. These results motivate separate evaluation of decision rules, candidate constraints, and realized reports.

Closest papers

Nearest neighbours by meaning across the whole index.

Reporting Practice Matters: The Impact of Reference Choice on Chest X-ray Report Evaluation

cs.CL cs.AI ·2026-09-16 ·Daniel P. Jeong, Charles Q. Li, Hossein Hosseiny, Nitya M. Bhalla, Fatma Uyar Morency +3 more
similarity 0.73
Abstract · Preprint

Radiologists follow heterogeneous reporting practices. Two radiologists examining the same image and identifying the same clinical findings might nevertheless compose superficially distinct reports, varying in terminology, shorthand, formatting, and level of detail. These variations in reporting norms represent an under-appreciated obstacle in efforts to evaluate AI-based radiology report generation (RRG) models, where machine-generated reports are typically assessed based on their concordance with human-generated references. In this paper, we quantify the sensitivity of established evaluation metrics to variations in reporting practices, revealing impacts large enough to alter the rankings of models. We introduce a radiologist-informed taxonomy of variations in radiology reporting practice and a method (ReRef) that rewrites reference reports along the axes of our taxonomy while preserving clinical interpretation. For instance, when comparing the performance of nine RRG models on MIMIC-CXR using RadCliQ-v1, condensing the discussion of normal findings in the reference reports causes Libra to drop from first to second place while CheXOne rises from third to first. Our results suggest that many current metrics fail to decouple clinical interpretation from conformity to reporting practices and that choosing the ``right'' references that accurately reflect the desired reporting practices can be important in practice. To support future research, we release MIMIC-CXR-Ext-ReRef, a radiologist-validated dataset of 120 (original, alternative) reference report pairs derived from MIMIC-CXR.

0.10

Retrieval-Grounded Multi-View Reasoning for Clinically Reliable Radiology Report Generation

cs.CV ·2026-11-03 ·Wanshu Fan, Zeyu Wang, Zheng Tong, Qi Ai, Wencai Weng +6 more
similarity 0.64
Abstract

Chest radiograph report generation is hampered by retrieved reports that resemble the current image but are clinically inconsistent with it, and by diagnostic-label imbalance. We present RG-MVR, a retrieval-grounded framework comprising Retrieval-Augmented Evidence Grounding, which combines dense memory summaries with visually gated sparse retrieved evidence; Adaptive Multi-view Evidential Reasoning, which weights image, memory, and retrieved evidence per case; and a Clinical Prompt Learner, which models finding mention separately from positive, negative, or uncertain status. On MIMIC-CXR, RG-MVR achieved a clinical-label F1 of 0.483 and a BLEU-4 of 0.118 (IU X-ray: 0.202 and 0.110). In an exploratory external cohort of 22 examinations, clinical-label agreement declined markedly (F1, 0.071) and unsupported statements remained common, although physicians found fewer unsupported temporal comparisons (9 vs. 20 cases) and device-related statements (7 vs. 15) than with the baseline. Evidence-aware retrieval and structured diagnostic prompting may reduce specific reporting errors, but broader external validation is required.

0.22

RadMatch: Auditable Radiology Report Evaluation via Finding-Level Matching

cs.CV ·2026-09-01 ·Charles Corbière, Léo Machado, Aubin Charley, Baptiste Callard, Pierre Manceron +1 more
publishedcode/data similarity 0.64
Abstract · Accepted to ECCV 2026 Workshop on Medical Foundation Models and Benchmarks

As AI systems are increasingly used to draft radiology reports, reliably evaluating their clinical quality remains a critical challenge. Large language model (LLM)-based metrics are now the best-correlated with radiologist judgment, yet they output a single opaque score that neither a clinician nor a model builder can easily interpret or audit. We introduce RadMatch, a multi-stage, LLM-based metric that decomposes report comparison into a structured finding-level matching with significance-aware scoring and error characterization across seven clinical attribute dimensions (status, location, severity, morphology, certainty, longitudinal comparison, and measurement). The main score is the actionable-error count, both interpretable and auditable. Candidate findings are graded correct, partial, or incorrect, and unmatched findings are counted as missed or hallucinated. Triage and actionable safety recall/precision and per-subset views add complementary, deployment-oriented lenses. Across two expert benchmarks, RadMatch is the most clinically aligned metric, matching inter-radiologist agreement on ReXVal and more than doubling the best prior metric on the harder RadEvalExpert. Relying only on few-shot prompting, it is designed to extend to other modalities and anatomies. We will release RadMatch as open-source code with an interactive dashboard for inspecting results.

0.54

From Augmentation to Synthetic Evidence: Evaluating Generated Chest Radiographs at Dataset Intake

cs.CV cs.AIcs.LG ·2026-10-21 ·Shaikh Akib Shahriyar, Zinedine Sehili, Adam Arthur, Christopher Schwartz
position similarity 0.64
Abstract

While generated chest radiographs can serve as valuable data augmentation when explicitly declared, the same pixels become unsupported evidence when submitted as records of real clinical examinations. We study this dataset-intake vulnerability by disentangling three questions: (1) whether an image passes an automated technical quality check, (2) whether an origin classifier flags it as synthetic, and (3) whether a trusted provenance record supports the claimed clinical acquisition. In this study, a submitter uses Qwen3.8-27B to select up to 20 candidate radiographs from pools of 1,000 Cheff-identified or SynthCheX images, while a receiver evaluates image quality via MedGemma 1.5 and predicts origin using a linear probe over frozen DINOv3 features. Although quality selection increases MedGemma quality passes from 12/20 to 19/20 for Cheff-identified images and from 8/20 to 17/20 for SynthCheX, we find no evidence that candidate selection increases passage through both checks simultaneously: zero selected Cheff-identified images pass both gates, and uniform, quality-guided, and surrogate-guided selection yield 2, 1, and 2 SynthCheX passes out of 20, respectively. On unprocessed test cohorts, the origin classifier rejects 4,677 of 5,000 SynthCheX images at a nominal 5% false-alarm rate (flagging 110 of 2,297 real NIH radiographs), yet leaves 152 SynthCheX images that pass both pixel-level checks. Moreover, pixel-level screening is fragile to routine distribution shifts: JPEG compression reduces SynthCheX-versus-NIH AUROC from 0.987 to 0.841, and applying the NIH-calibrated threshold to an external genuine cohort (Open-I) triggers false alarms on 568 of 957 authentic radiographs (59.4%). Because pixel-level checks can filter submissions but cannot verify clinical acquisition claims, we argue that dataset intake pipelines must record and verify source provenance independently of image pixels.

0.13

RadRef: A Reference-Free Metric for Radiology Report Generation

cs.LG ·2026-11-09 ·Shelly Schwartz, Alan Ropp, Michael B. Sneider, Nur Yildirim, Cree M. Gaskin +1 more
similarity 0.63
Abstract

AI-generated radiology reports are commonly evaluated against radiologist-authored references, limiting the applicability of standard reference-based metrics when no reference is available. We introduce RadRef, a reference-free metric that scores report claims against image-derived beliefs over a clinical finding vocabulary, weighted by relevance to the clinical indication. By evaluating findings beyond the report's stated claims, RadRef assesses omissions as well as unsupported assertions. On ReXVal, RadRef achieves $73.1\%$ agreement with radiologist rankings among non-tied same-radiograph report pairs, with $61.8\%$ pair coverage and $64.3\%$ tie-inclusive agreement. Its non-tied agreement is close to GREEN ($73.9\%$) and RadFact ($72.6\%$), with its strongest relative results on omissions. We further evaluate $100$ model-generated and $100$ radiologist-authored reports from $100$ MIMIC-CXR studies, independently annotated by two board-certified radiologists. On same-image omission rankings, RadRef attains Kendall's $τ_b = 0.295$, compared with $0.386$ between the readers. In separate paired comparisons across generated reports, no evaluated comparator significantly outperforms RadRef on omissions. The same image-grounded representation provides a false-finding readout, RadRef-FF, with $τ_b = 0.32$ on ReXVal and $0.29$ in the reader study. Controlled perturbations confirm that RadRef depends on the radiograph, report, and clinical indication. RadRef enables image-grounded evaluation before a radiologist-authored reference exists, supporting quality monitoring of report-generation systems in clinical settings, and complements reference-based metrics when one is available.

0.21

CHARTER: Auditing Reference Substitution in Hierarchical Compact-Evidence Evaluation for Computational Pathology

cs.CV cs.LG ·2026-10-06 ·Hyun Do Jung, Jungwon Choi, Soojung Choi, Yujin Oh, Hwiyoung Kim
similarity 0.63
Abstract

In digital pathology, compact evidence is often used to explain or audit predictions made by whole-slide image multiple instance learning models. In hierarchical compact-evidence pipelines, candidate filtering introduces a strategy-specific candidate-conditioned prediction alongside the original full-bag prediction. If the evaluation reference changes while the intended target remains the original full-bag prediction, however, not only can the measured fidelity of the same compact evidence change, but comparisons between competing candidate strategies can also change. To make this dependence explicit, we introduce CHARTER, a reference-aware evaluation charter that asks researchers to DECLARE the intended target and reference, QUANTIFY candidate-induced prediction shift, and AUDIT the stability of comparative conclusions. Across the 15 comparisons in our main five-seed Random-K audit, 4 showed determinate reversals; in a matched native-ranking stress test, the ACMIL comparison changed from REVERSED to PRESERVED. CHARTER turns otherwise implicit candidate-filtering and reference choices into an auditable evaluation specification, helping distinguish genuine preservation of the intended prediction from apparent gains induced by changing the prediction being explained.

0.17

Pre-training, Reasoning, Benchmarking: X-ray Report Generation on CheXpert Plus Dataset

cs.CV cs.AI ·2026-09-23 ·Xiao Wang, Yuxiang Zhang, Dan Xu, Yuehang Li, Shiao Wang +4 more
benchmarkcode/data similarity 0.61
Abstract

X-ray image-based Radiology Report Generation (RRG) constitutes a critical research direction within medical artificial intelligence, with great potential to alleviate clinicians' diagnostic workload and shorten patient waiting periods. Despite substantial advances over recent years, the field faces evident bottlenecks stemming from insufficient standardized benchmarks and inadequate domain adaptation of generic large models. Notably, the newly released CheXpert Plus dataset is provided without accompanying baseline implementations and evaluation results, which impedes standardized training, quantitative evaluation and fair comparison among follow-up algorithms. To mitigate this limitation, we establish a comprehensive benchmark encompassing prevailing X-ray report generation models and Large Language Models on CheXpert Plus. This benchmark delivers a reliable comparative foundation for upcoming methods and enables researchers to rapidly identify state-of-the-art approaches within this domain. Beyond benchmark construction, we rethink X-ray RRG under the paradigm of large models and propose a novel framework termed MambaXray-PRB. Our framework improves report generation performance and enhances model interpretability via multi-stage large-model pre-training and multi-modal Chain-of-Thought reasoning. The pipeline consists of three successive phases: self-supervised auto-regressive modeling, X-ray-report contrastive learning, and post-training optimization for reasoning and report generation. Extensive experiments on IU X-ray, MIMIC-CXR, and CheXpert Plus datasets validate the effectiveness of MambaXray-PRB for radiology report generation. The source code of this paper is available on https://github.com/Event-AHU/Medical_Image_Analysis

0.32

Decide, Ask, or Defer: Clinical LLMs under Incomplete Evidence

cs.AI ·2026-10-03 ·Mingzhan Yang, Weili Wu
published similarity 0.61
Abstract · Accepted to the Main Track of the NeurIPS 2026 GenAI4Health Workshop

Clinical LLMs must decide not only what diagnosis to produce, but also whether the available evidence is sufficient for autonomous decision making. Binary DECIDE/ABSTAIN formulations merge distinct non decision states and do not explicitly evaluate information acquisition. We introduce a DECIDE/ASK/DEFER formulation together with a blinded protocol that prevents models from using evidence completeness metadata. We evaluate Qwen, Gemini, and GPT on 200 matched clinical evidence states constructed from DDXPlus. The models show substantial differences in action selection under identical evidence, with disagreement in 137 of 200 states. For Qwen, a matched targeted versus random analysis shows that selected information changes the likelihood of a subsequent autonomous decision more clearly than diagnostic correctness. Its matched DECIDE/ABSTAIN baseline further reveals a safety autonomy tradeoff: the three action policy rescues some erroneous autonomous decisions but also removes some correct autonomous deci sions. These results show that separating information acquisition from clinician deferral exposes behavior that binary abstention hides, without yielding a uniformly improved decision policy.

0.31