CS Paper Radar

Variable Input Masked Autoencoders for Wrist-Worn Accelerometry

Harish Haresamudram, Wanting Mao, Aditya Radhakrishnan, Maxwell A. Xu, James M. Rehg

cs.LG ·submitted 2026-10-12 20:41 UTC · v1
benchmark

Abstract

Large-scale repositories of wearable sensor data have enabled the development of foundation models for human activities and behavior. However, existing models are pretrained using fixed input durations and sampling rates, despite substantial heterogeneity in recording conditions, downstream tasks, and deployment constraints. We introduce VarMAE, a variable input masked autoencoder that learns a single representation across sampling rates and temporal contexts. During pretraining we construct two views of the same signal: a long duration high frequency view, and a short duration lower frequency view, obtained via random cropping and downsampling. We perform masked reconstruction within each view and introduce a cross-resolution masked reconstruction objective that uses visible tokens from the long view to predict masked tokens from the short view. Cropping and downsampling impose complementary information bottlenecks, encouraging the model to learn representations that remain effective across input durations and sampling rate changes. We pretrain VarMAE on the large-scale NHANES dataset, producing a single pretrained encoder matching or outperforming controlled foundation model baselines on eight benchmark datasets. With only 3.82M parameters, VarMAE is parameter efficient and shows that a single foundation model can achieve broad transfer capabilities across sensing configurations.

Closest papers

Nearest neighbours by meaning across the whole index.

Characterizing the Performance Gap in Human Activity Recognition for Older Adults

cs.HC cs.LG ·2026-10-02 ·Hossein Khayami, Sungjin Hwang, Eshed Ohn-Bar, David E. Conroy, Amanda Lazar +2 more
publishedbenchmark similarity 0.67
Abstract · 8 pages, 6 figures, to be published in Proceedings of the 2026 ACM International Symposium on Wearable Computers (ISWC '26)

Human activity recognition (HAR) from wrist-worn accelerometers is increasingly used for health and behavioral tracking. Yet, most wearable HAR models are developed and evaluated on datasets dominated by younger adults, leaving it unclear whether benchmark progress generalizes across age groups. In this work, we leverage MyMove, our carefully annotated, free-living older-adult HAR dataset (mean age 71), to evaluate deep-learning architectures and training regimes under both leave-one-subject-out and cross-dataset transfer. We find that improvements on younger-adult benchmarks fail to transfer equally to data collected from older adults, resulting in a persistent and often widening performance gap. However, richer representations, particularly frozen self-supervised features pretrained on the age-diverse UK Biobank dataset, substantially improve performance on data from older adults and consistently narrow the performance gap, at modest cost to younger-adult performance, though disparities remain. These findings suggest that benchmark gains and architectural scaling alone provide an incomplete picture of progress in wearable HAR, and broader advances may require representations that better capture population diversity, alongside personalized adaptation to individual movement patterns and routines.

0.21

HeteroWear: Sensor-Aware Self-Supervised Learning for Heterogeneous Wearable Activity Recognition

cs.LG cs.AIeess.SPstat.ML ·2026-11-13 ·Yasaman Mohammadpour, Pouya Shaeri
publishedcode/data similarity 0.67
Abstract · Extended version of a paper accepted at IEEE BigData 2026. Code: https://github.com/yasamanmohammdpour/HeteroWear

Self-supervised learning for wearable sensing is usually confined to a single dataset or device family, leaving open whether representations transfer across heterogeneous sensor configurations and whether gains come from pretraining rather than architecture or richer sensor input. We present HeteroWear, a sensor-aware self-supervised framework pretrained on an eight-dataset wearable corpus (173 subjects, 358,261 windows) spanning inertial and physiological signals across body locations, devices, and sampling rates. HeteroWear separates within-sensor temporal modeling from cross-sensor relational modeling using sensor-context embeddings, temporal and cross-sensor Transformers, and latent cross-attention fusion. Training combines structured sensor dropout, cross-configuration consistency, and per-axis masked sensor modeling; missing sensors are omitted rather than reconstructed. Under leave-one-dataset-out pretraining and subject-disjoint evaluation on PAMAP2, WISDM, HHAR, HARTH, and UCI-HAR, HeteroWear improves mean macro-F1 from 0.688 to 0.724 over the identical architecture trained from scratch, with the largest gain on HHAR (0.823 versus 0.741), and achieves the highest macro-F1 on four of five benchmarks relative to single-accelerometer supervised baselines. Held-out-device evaluation yields a mean +0.066 macro-F1 improvement. Under 50% test-time channel removal, HeteroWear retains 73.8% of full-channel performance versus 64.1% for the same architecture trained from scratch without sensor dropout. Ablations show that structured sensor dropout primarily drives robustness, while cross-configuration consistency and sensor-context encoding contribute to transfer.

0.24

W-JEPA: Wavelet Joint-Embedding Predictive Architecture for Wearable Activity Recognition

cs.LG ·2026-10-14 ·Yogesh Prabhu, Loki Natarajan, Jingjing Zou
similarity 0.66
Abstract · 11 pages, 4 figures

A major challenge in wearable device activity recognition is the heterogeneity across datasets in sensor placement, channel count, sampling rate and subjects. Moreover, the motion patterns that distinguish activities often appear as subtle, scale-specific variations within otherwise similar waveforms. As a result, raw signals are often ambiguous, and models trained on them tend to rely on cues specific to a particular sensor setup or participant, which limits both cross-dataset transfer and generalization to unseen participants. Addressing this requires representations that preserve such activity-relevant, scale-specific variation. We introduce W-JEPA, a self-supervised framework that exploits the multiscale structure of inertial motion and leverages a joint-embedding predictive architecture, by organizing windows into a fixed grid of wavelet tokens indexed by scale, sensor axis, and time. These wavelet tokens help expose activity-specific detail within broadly similar raw signals, and serve as the units of masked latent prediction. W-JEPA predicts masked token representations supplied by an exponential-moving-average (EMA) target encoder. Because recovering a masked token requires relating motion at one scale and axis to motion at other scales and axes, the model learns the cross-scale, cross-axis structure of human movement. Across six wearable activity benchmarks, W-JEPA outperforms state-of-the-art methods under random-window splits and remains the strongest when subjects are held out, improving average macro-F1 by 8.7 percentage points over the strongest published baseline. These results indicate that physically grounded multiscale tokenization, combined together with latent predictive learning, provides a promising foundation for transferable representations of heterogeneous wearable inertial data.

0.16

SOTER: A Generative Time-Series Foundation Model for Wearable Human Physiological Signals

cs.LG cs.AI ·2026-09-15 ·Fangke Chen, Sirry Chen, Wei Chen, Zhongyu Wei
similarity 0.64
Abstract

Time-series foundation models have demonstrated strong cross-domain transfer, yet their common architectural assumptions remain poorly aligned with wearable physiological signals, which are multichannel, irregularly sampled, noisy, and governed by coupled continuous-time dynamics spanning distinct spectral scales. We present SOTER, a generative foundation model for wearable physiological time series that unifies cross-channel coupling, spectrum-guided expert specialization, and continuous-time latent evolution within a single pre-training framework. SOTER combines a spatial feature-aware backbone that models inter-signal dependencies, a power spectral density (PSD)-guided mixture-of-experts layer that routes representations to experts associated with fixed spectral bands through an inspectable, non-learned rule, and a neural controlled differential equation decoder that supports prediction and imputation at arbitrary timestamps. We pre-train SOTER on 226 billion time points from five public physiological datasets and evaluate the same pre-trained model across out-of-distribution zero-shot forecasting, frozen-encoder linear-probe classification, and continuous-time imputation on wearable benchmarks. SOTER achieves the best RMSE on 4 of 6 datasets and the best MAE on 5 of 6 in zero-shot forecasting, the highest average Macro-AUROC in classification, and the lowest imputation error on all six datasets at 75% missingness. It further remains robust to additive acquisition noise, matching or surpassing baselines evaluated on clean inputs even under the strongest corruption. These results indicate that domain-specialized foundation models for wearable physiology benefit from jointly modeling channel structure, spectral scale, and continuous-time dynamics.

0.46

IMU-Bench: Benchmarking Wrist IMU Representations Across Kinematic, Semantic and Clinical Tasks

cs.RO cs.AI ·2026-10-14 ·Yiquan Li, Aidan Bradshaw, Chenfeng Gao, Karan Ahuja
benchmarkcode/data similarity 0.64
Abstract

Wrist-worn inertial measurement units (IMUs) provide a common sensing modality for tasks ranging from activity and gesture recognition to pose estimation, inertial odometry and clinical motor assessment. Existing wearable benchmarks evaluate performance across multiple tasks, but leave open how supervision for one task affects transfer to others and whether these tasks benefit from a shared representation. We present IMU-Bench, a benchmark of ten tasks from eight datasets for studying IMU multi-task performance and cross-task transfer. We compare six self-supervised methods pretrained on unlabeled recorded and simulated wrist motion, evaluating classification, pose and velocity estimation, and IMU-language retrieval. We find that our masked autoencoder, InrtlWrist, achieves the best or joint-best frozen-probe performance on nine of ten tasks, and fine-tuning improves on training from scratch on nine of ten tasks, including full-body pose, odometry and retrieval. Across transfer and joint-training experiments, supervision that benefits one target can reduce performance on others, with supervised sources transferring within kinematic estimation while, under frozen probing, none approaches the pretrained encoder on language retrieval, and joint-training gains that come at a cost to the paired task. These findings distinguish broad downstream usefulness from complementary task supervision. Code, task cards and a leaderboard are publicly available.

0.17

Beyond Simulated Benchmarks: Evaluating Motion Representations for Fall Detection Under Real-World Data Scarcity

cs.LG ·2026-08-13 ·Timilehin B. Aderinola, Ilaria D'Ascanio, Luca Palmerini, Lorenzo Chiari, Jochen Klenk +3 more
similarity 0.64
Abstract

Falls are a major health concern for older adults, and wearable sensors have been widely explored for detecting falls and enabling timely intervention. However, real-world falls are extremely rare: collecting 100 of them requires an estimated 100,000 days of monitoring, resulting in severely limited labelled data for training machine learning models. Consequently, many approaches rely on simulated datasets, often reporting high laboratory performance but limited real-world generalisation. We present a systematic evaluation of motion representations for wearable fall detection under real-world data scarcity. Using accelerometer signals, we compare interval-based, kernel-based, symbolic, and foundation model representations. As an interpretable baseline, we additionally investigate a lightweight symbolic representation that converts short motion segments into symbolic sentences augmented with physically-grounded impact descriptors. Experiments use FallAllD, a simulated falls dataset, and FARSEEING, a clinically verified real-world falls dataset. Through cross-validation, controlled data scarcity, and cross-dataset transfer, we examine how representation choices affect robustness under realistic deployment. Our results reveal that highly parameterised kernel and foundation models excel on simulated data but degrade severely under both data scarcity and domain shift. Although the interval-based representation achieves the strongest absolute real-world performance, augmenting a symbolic representation with physically-grounded impact descriptors yields the smallest degradation under domain shift and retains detection sensitivity under extreme scarcity, albeit at lower precision. These findings highlight the importance of evaluating beyond simulated benchmarks and show that representation choice is critical for deployable fall detection given the scarcity of real-world data.

0.04

Recurrent Temporal Restricted Boltzmann Machines as Unsupervised Encoders for Biomechanical Movement Sequences

cs.LG eess.SP ·2026-10-17 ·Wafi Sharif, Nicholas LaHaye
similarity 0.63
Abstract · 15 pages, 7 figures, 5 tables. Under review at Transactions on Machine Learning Research (TMLR)

Biomechanical movement recordings are continuous, high-dimensional time series, and analyzing them without manually labeling them requires representations that capture how movements evolve over time. Most unsupervised representation-learning pipelines, however, treat each observation frame independently and discard this temporal structure, while energy-based models that could capture it have not extensively been adapted to biomechanical signals. So, this paper implements the Recurrent Temporal Restricted Boltzmann Machine (RTRBM), a recurrent energy-based model, into an unsupervised encoder that maps windows of movement data to fixed-length embeddings, and tests what its recurrent structure contributes. We adapt the model to continuous-valued signals, stack it into a deep architecture, and integrate it into the SIT-FUSE segmentation pipeline. We evaluate the embeddings on simulated musculoskeletal reaching and on two real gait datasets, using clustering, reconstruction, and walking-speed classification of unseen subjects, and compare them against non-recurrent and non-probabilistic baselines, including a control that removes the recurrent connection. Clustering the embeddings recovers movement structure tied to progress toward the target without any labels, which also transfers to unseen episodes. On gait data, the embeddings outperform PCA and autoencoder baselines under a nonlinear probe. However, removing the recurrent connection does not yield a measurable loss on the reaching task, and simple per-channel summary statistics classify walking speed at least as well as the embeddings. The model is therefore a working, verified encoder for SIT-FUSE, while the evidence for a benefit of recurrence is mixed, and the learned embeddings did not outperform simple summary statistics on gait.

0.25

EMG-GPT: Predictive Pretraining on Residual-Quantized EMG Tokens for Hand Pose Estimation

cs.LG cs.AI ·2026-10-04 ·Ettore Magni, Rolandos Alexandros Potamias, Stefanos Zafeiriou, Konstantinos Barmpas
similarity 0.62
Abstract

Surface electromyography (sEMG) is a low-power, cost-effective biosignal for hand-pose estimation and gesture classification. In this work, we examine whether self-supervised pretraining on sEMG can yield transferable representations for continuous hand-pose estimation. We introduce EMG-GPT, a causal transformer-based model that operates on discrete sEMG representations from a frozen residual vector quantization (RVQ) tokenizer and learns temporal dynamics through depth-autoregressive future-code prediction. The model combines within-frame integration with causal temporal modeling while preserving the geometry of the pretrained codebook. EMG-GPT shows competitive results in both Regression and Tracking tasks, supporting EMG-only pretraining as a viable approach for learning transferable sEMG representations.

0.12