Dual-Domain Sparse-View 4D CBCT Reconstruction with Spatial-Temporal Consistency Learning

Qi Lai, YuTong He

cs.CV ·submitted 2026-10-13 15:10 UTC · v1

Abstract

Four-dimensional cone-beam computed tomography (4D CBCT) provides phase-resolved volumetric images for image-guided radiotherapy. Yet good reconstruction quality usually needs many projections. This increases scan time and radiation dose. We propose STCNet, a sparse-view 4D CBCT reconstruction framework that uses spatial-temporal consistency learning. STCNet reconstructs high-quality images from only 16 projections in each respiratory phase. STCNet integrates physics-driven positional encoding to enforce geometric consistency in the projection domain and introduces temporal encoding in latent space to capture respiratory motion dynamics across phases to capture dynamic respiratory motion across phases. A dual-domain collaborative strategy jointly optimizes both projection and image domains, enhancing structural fidelity and temporal coherence. We tested STCNet on the TCIA-LUNG dataset and a CIRS thorax phantom dataset. STCNet performed better than conventional methods and recent deep learning baselines in image quality, artifact reduction, and structural preservation. On TCIA-LUNG, STCNet reached PSNR values of 33.311, 32.695, and 32.658 dB at phases 2, 5, and 8. The corresponding SSIM values were 0.845, 0.823, and 0.825. On CIRS, STCNet achieved PSNR values up to 36.497 dB and SSIM values up to 0.877. These results support STCNet as a promising framework for low-dose, phase-resolved 4D CBCT reconstruction in image-guided radiotherapy.

Closest papers

Nearest neighbours by meaning across the whole index.

Extremely Sparse-View Computed Tomography from 2D Projections via Pose-Aware Diffusion Priors

cs.CV cs.AI ·2026-10-28 ·Linrui Dai, Jinxiu Liang, Chu Zhou, Mae Yamaguchi, Ryuya Takahashi +1 more
published similarity 0.71
Abstract · NeurIPS 2026 poster

Extremely sparse-view computed tomography (xSV-CT) is critical when scanning time, motion, or radiation tolerance limits each scan to only a few projections. In many such scenarios, the same acquisition limits also constrain dataset construction, making pre-reconstructed 3D volumes from dense scans unavailable. This exposes a gap in current sparse-view approaches: Optimization-based methods, which use the sparse measurements directly but lack data-driven priors to suppress artifacts, and learning-based methods, which use strong priors but usually require densely scanned training volumes acquired outside the xSV-CT regime. We study this train-sparse / infer-sparse setting by learning a pose-aware diffusion prior from one 2D projection per training sample, then guiding diffusion sampling with measured-view fidelity, shared-volume reprojection, and projection-physics consistency for tomographic reconstruction. On two public CT datasets across 1-, 4-, and 8-view settings, the proposed method achieves the best novel-view synthesis scores and best or competitive reconstruction quality compared with baselines that use dense-volume supervision.

0.26

PhyDiCT: Plug-and-Play CT Reconstruction from Sparse X-Rays via Differentiable Rendering and Strong Priors

cs.CV ·2026-10-07 ·Weicheng Dai, Shantanu Ghosh, Kayhan Batmanghelich
top venuecode/data similarity 0.71
Abstract · Accepted at MICCAI 2026; to appear in LNCS 16888

Reconstructing 3D Computed Tomography (CT) images from a few X-ray projections is a highly ill-posed inverse problem due to the loss of volumetric information. We propose PhyDiCT, a training-free framework that integrates a differentiable Physics-based forward model, grounded in the Beer-Lambert law, with a text-conditioned Diffusion as a strong prior to reconstruct 3D lung CT images. We refer to our approach as training-free since the prior model is used without fine-tuning, and our goal is to steer the denoising procedure to generate samples consistent with X-ray observations. We guide the diffusion generation using Split Gibbs sampling to jointly optimize for projection fidelity (reward) and consistency with prior knowledge. Also, we introduce a test-time refinement step that enhances image realism and anatomical coherence. We extensively evaluate our method on publicly available 3D CT datasets using both perceptual and semantic metrics, demonstrating that it surpasses existing plug-and-play diffusion and fully trained reconstruction approaches. Our findings highlight that combining a strong generative prior with the underlying physics of image formation substantially improves reconstruction quality, e.g., 7.5\% improvement on SSIM compared to full training methods. Code will be released at https://github.com/batmanlab/PhyDiCT.

0.44

Multi-Pass, Multi-View Blended Learning for High-Fidelity Volumetric CT Synthesis from Chest X-Rays

cs.LG ·2026-09-09 ·Ozer Can Devecioglu, Serkan Kiranyaz, Rashid Mazhar, Tahir Hamid, Muhammad Chowdhury +1 more
code/data similarity 0.70
Abstract · 13 pages, 11 figures

Reconstructing volumetric Computed Tomography (CT) from a single 2D chest radiograph (CXR) is an ill-posed inverse problem, further complicated by the scarcity of paired CXR-CT training data. Prior approaches address this by training on Digitally Reconstructed Radiographs (DRRs), which are synthetic projections derived from CT volumes. However, the domain gap between DRRs and real CXRs limits generalization, often resulting in coarse or anatomically inconsistent reconstructions when applied to clinical images. To address this challenging problem, this study introduces a Multi-Pass Multi-View Blended Learning framework for synthesizing high-fidelity volumetric CT directly from real chest X-ray (CXR) images. The proposed approach progressively decomposes the synthesis task into two distinct, complementary learning stages. Stage 1 is an unsupervised CXR-to-DRR Domain Adaptation, while Stage 2 includes three passes, namely, (a) supervised DRR-to-CT Transformation, (b) unsupervised Multi-View Slice Refinement, followed by (c) Progressive Transfer Learning (PTL). With such a blended learning paradigm, the proposed approach mitigates the synthetic-to-real domain gap while enhancing both the structural integrity and anatomical detail of the final output. On the LIDC-IDRI dataset, where paired DRR-CT ground truth is available for quantitative evaluation, the proposed method improves upon prior methods by up to 14% in PSNR and 7.6% in SSIM. The framework successfully generates structurally consistent and anatomically realistic high-fidelity CT volumes from real CXRs, marking a significant advancement toward clinical viability of CT reconstruction from standard radiographic images.

0.36

EUReCA: End-to-End Unified CBCT Reconstruction Across Clinical Acquisitions

eess.IV cs.AI ·2026-10-27 ·Jiening Zhu, Chengzhu Zhang, Jason Fan, LiCheng Kuo, Weixing Cai +6 more
similarity 0.68
Abstract

Cone-beam computed tomography (CBCT) is widely used for image-guided radiotherapy, but reducing the number of projections to lower dose and scan time makes reconstruction increasingly ill-posed. We present EUReCA (End-to-end Unified REconstruction across Clinical Acquisitions), a geometry-aware feed-forward model for variable-view clinical linac CBCT. For a given acquisition trajectory, EUReCA accepts 8-100 projections with a single set of weights, without view-count-specific retraining; the same architecture and training recipe extend unchanged to other clinical trajectories. It combines learned projection features with an in-frame Feldkamp-Davis-Kress (FDK) reconstruction. The model encodes each projection with a shared multiscale backbone, back-projects features into multiresolution 3D grids using the acquisition geometry, aggregates variable numbers of views at fixed computational cost, and refines the volume with a global 3D transformer and multilevel decoder. On simulated data, EUReCA achieved 29.9-33.2 dB PSNR with 10-100 views and outperformed all applicable feed-forward baselines; it also exceeded iterative optimization-based methods while running orders of magnitude faster. On 15 measured patient CBCT scans evaluated against vendor reconstructions, EUReCA achieved the best performance at every tested view count. These results suggest that geometry-aware, measurement-anchored feed-forward reconstruction can provide a practical and flexible foundation for variable-view linac CBCT.

0.25

TomoTransformer: Towards a Foundation Model for CT Reconstruction

cs.CV cs.LG ·2026-09-29 ·AmirEhsan Khorashadizadeh, Benjamín Béjar
benchmark similarity 0.68
Abstract

Supervised deep learning has advanced sparse-view tomographic reconstruction. However, conventional models, which typically map filtered back-projection (FBP) images or sinograms to clean reconstructions, are brittle under distribution shifts. Because they require retraining whenever projection counts and angles, detector resolutions, or data distributions change, their deployment in real-world applications remains limited. To address this, we introduce TomoTransformer, a transformer-based architecture that treats each \textit{local} filtered projection as an individual token and predicts missing views via self-attention. Crucially, TomoTransformer operates in a \emph{back-projection space} that separates projections across spatial locations, making view interpolation geometrically well-posed and invariant to detector size. This design yields a single foundation model that can process any number of input projections, at arbitrary angular locations and detector dimensions, and query any number of target angles without retraining. Trained on a large-scale dataset spanning diverse medical CT anatomies and natural images, TomoTransformer generalizes effectively across anatomies, materials, and resolutions. Extensive evaluations on several benchmark sparse-view datasets show that TomoTransformer significantly outperforms concurrent multi-purpose models like ViewTrans and matches or exceeds strong protocol-specific baselines, while remaining fully agnostic to the number of input and target projections. Furthermore, the model demonstrates robust zero-shot generalization on real experimental nanoscale brain data collected from an X-ray synchrotron, showcasing its practical utility for real-world applications.

0.19

Anatomy-preserving unpaired cone-beam CT refinement for image-guided radiotherapy using pseudo-label guided diffusion

cs.CV ·2026-10-05 ·Qi Lai, Yutong He
code/data similarity 0.67
Abstract

Cone-beam computed tomography (CBCT) is widely used in image-guided radiotherapy, but scatter, beam hardening, noise, truncation, and other artifacts limit image quality and CT number accuracy. Paired CBCT and CT data are difficult to obtain clinically because of motion, anatomical changes, and acquisition mismatch. We present RefineCBCT, an unpaired CBCT refinement framework that uses pseudo-label guidance and short-step diffusion to reduce artifacts while preserving patient-specific anatomy. RefineCBCT was trained and evaluated on unpaired CBCT and planning CT data from public LUNG TCIA and PELVIC TCIA datasets and compared with representative GAN and diffusion based methods. On LUNG TCIA, it achieved the best results across all metrics, with MAE 19.411, RMSE 62.758, PSNR 30.845 dB, and SSIM 0.931. On PELVIC TCIA, it achieved the best MAE, PSNR, and SSIM, with values of 14.905, 36.671 dB, and 0.876. The refined images showed fewer streaking and shading artifacts, clearer anatomical boundaries, and improved soft tissue uniformity, with line profile and ROI analyses showing closer agreement with planning CT. These results suggest that RefineCBCT provides efficient and effective CBCT refinement under clinically realistic unpaired training conditions and may support more reliable CBCT use in image-guided radiotherapy workflows. Code is publicly available on GitHub, and the evaluated datasets are available from The Cancer Imaging Archive.

0.21

EPC-RawDC: Equivariant Physics Constrained 3D Diffusion with Raw Data Consistency for CBCT to CT Image Synthesis

cs.CV cs.AIphysics.med-ph ·2026-10-29 ·Alzahra Altalib, Chunhui Li, Alessandro Perelli
code/datahot direction similarity 0.67
Abstract · 10 pages, 4 figures, 8 tables

Cone beam computed tomography (CBCT) is widely used for image guided and adaptive radiotherapy, but scatter, noise, reconstruction artifacts, and inaccurate Hounsfield units limit its quantitative use. Recent diffusion approaches for CBCT to CT synthesis remain largely image driven, with limited use of the underlying acquisition physics. We propose EPC-RawDC, a conditional 3D latent diffusion framework that combines volumetric generative modeling with two complementary constraints derived from the same scanner specific CBCT forward model. First, geometry equivariant projection constraint exploits the rotational equivariance of the CBCT forward operator by supervising the synthesized CT through correspondingly transformed reference projections. Second, raw data consistency uses noisy projection measurements of the individual acquisition as scan specific supervision during training. The framework was evaluated on two independent clinical cohorts with distinct scanner geometries and projection sources. For JUST, the physics constraints used measured clinical raw CBCT projections acquired with an Elekta system, whereas for SynthRAD2025 the projection data were simulated from the reference CT using a Varian geometry with Poisson photon statistics. EPC-RawDC achieved an SSIM of 0.97 in both cohorts and improved PSNR over DDPM by 2.66 dB on SynthRAD2025 and 2.10 dB on JUST, while reducing mean MAE by 20.3% and 19.0%, respectively. On SynthRAD2025, projection consistency and equivariant errors were reduced by 55.0% and 41.4% relative to DDPM. These results demonstrate that combining a volumetric diffusion prior with scanner geometry and scan specific projection measurements improves quantitative CBCT to CT synthesis across both simulated and measured projection domains. Code available after publication at https://github.com/ALZAHRAALTALIB/EPC-RawDC.

0.37

SparseTokenGS: Gaussian-based Sparse-View CBCT Reconstruction via Reusable Token Pool

cs.CV cs.AI ·2026-10-28 ·Zihan Deng, Zhenzhen Gong, Yujie Liu, Jiaxin Gong, Dingkun Liu +8 more
code/data similarity 0.66
Abstract · 10 pages, 12 figures. Submitted to IEEE Transactions on Medical Imaging

Sparse-view cone-beam computed tomography is widely used for fast, low-dose volumetric imaging and lesion localization in dentistry and image-guided interventions, but it introduces severe artifacts. Feed-forward Gaussian methods transfer the reconstruction cost to training and decode each coordinate from projection-aligned features and neighboring anchors. However, information from the whole scan is written only when the field is constructed and cannot be retrieved during coordinate decoding, leaving the volume inconsistent within the scan. This is a common limitation of such methods: once the field is fixed, decoding uses only local features and reconstruction quality drops substantially. We propose SparseTokenGS, a Gaussian-based method for sparse-view cone-beam computed tomography reconstruction via a reusable token pool. Anchor Token Fusion and Point-Token Attention query this shared pool at the anchors and at the query coordinates, respectively. The local Gaussian prior is retained, and the volume is reconstructed in one forward pass, without per-scan optimization or a projection-domain loss. On three public chest and dental datasets, SparseTokenGS achieves the highest reconstruction performance among the compared methods. On clinical dental scans, reconstruction from only six projections reaches 29.51 decibels in peak signal-to-noise ratio and a structural similarity of 0.842 against the full-view reference, and off-the-shelf tooth-and-pulp segmentation keeps these structures separable for root-canal localization. Experiments on volcanic rock and chicken show performance after same-object adaptation. A reusable token pool gives feed-forward reconstruction a mechanism that keeps scan-wide context available through decoding and can benefit future rapid clinical lesion localization and analysis. The code is available at: https://github.com/FrankDengAI/SparseTokenGS.

0.36