CS Paper Radar

Diagnosing Low-Confidence Patient Profiles via Localized Harmful Covariate Shift Detection

Olivier Lefebvre, Hakima Laribi, Dan Poenaru, Martin Vallières

cs.LG cs.AI ·submitted 2026-10-13 20:44 UTC · v2
publishedcode/data

Abstract

Before deploying clinical prediction models, their reliability must be assessed to ensure safe use. Errors may arise from distribution shifts between training and deployment or from heterogeneous performance where the model systematically underperforms for certain patient subgroups. Yet most post-hoc diagnostic methods evaluate reliability only at the population level, checking whether the deployment data resemble the training data and whether the model performs well on average, without accounting for heterogeneity that may cause some patients to be disproportionately affected. We propose a unified diagnostic pipeline that combines both perspectives. MED3pa first discovers interpretable low-confidence patient profiles, and Detectron is then applied within each profile to test whether its degradation is associated with a detectable harmful covariate shift. Across three clinical prediction tasks and three injected subgroup shifts in MIMIC-IV, we find that shift detectability itself is informative. An injected age shift, undetectable at the population level, was nonetheless localized to specific degraded profiles, whereas sex- and race-related shifts were detected broadly and therefore offered little guidance for identifying the most affected patients.

Comment
Accepted at SMASH (Symposium on Machine Learning and Applications in Healthcare) 2026. Code available at https://github.com/MEDomicsLab/study_MED3pa_SHIFT2026

Closest papers

Nearest neighbours by meaning across the whole index.

Repeated-Measure Leakage, Distribution Shift, and Reliability under Partial Observation in Patient World Models

cs.LG ·2026-10-03 ·Arjun Subramanian
publishedcode/data similarity 0.65
Abstract · 13 pages, 7 figures. Selected for oral presentation at the NeurIPS 2026 Workshop on World Models for High-Stakes Health (WMHS) Replication P…

Patient world models are increasingly proposed for longitudinal prediction, intervention-aware reasoning, and clinical-trial simulation. Causal or clinical intervention validity is distinct from predictive generalization and reliability; before making stronger claims, the underlying predictive state should generalize across patients, survive realistic shifts and missing observations, and expose failure through meaningful reliability signals. We evaluate these prerequisites in a deliberately narrow setting: short-horizon digital-biomarker forecasting from PhysioNet GaitPDB, comprising 165 participants, 306 recordings, and 51,129 context-future pairs. Using persistence, ridge, MLP, GRU, Transformer, and a compact JEPA-style predictor, we build an evaluation ladder that progressively removes raw temporal overlap, same-recording familiarity, and same-patient familiarity before testing unseen-patient generalization. For GRU, NMSE rises from 0.1227 under random-window splitting to 0.1393 after eliminating raw train-test overlap and to 0.1961 under patient holdout. Among 54 participants with repeated recordings, exposure to a different recording from the same patient improves GRU NMSE from 0.2177 to 0.1556, while a recording-excluded identity hypothesis is not supported at the participant level. Under participant-held-out evaluation, MLP and Transformer are statistically indistinguishable. Study shift, a four-times-longer prediction gap, and partial observation further degrade performance; under 50% temporal masking, Transformer NMSE rises to 0.611 while MC-dropout predictive variance falls. We do not claim a longitudinal or intervention-aware simulator. Instead, the results support a prerequisite evaluation stack of patient separation, repeated-measure controls, shift, missingness, and uncertainty validation before stronger patient-world-model claims are trusted.

0.39

The Ceiling Is in the Channel: Auditing Learner Gaps and Measurement Frontiers in Clinical Prediction

cs.AI ·2026-09-01 ·Sayeed Shafayet Chowdhury, Nusrat Jahan, Snehasis Mukhopadhyay, Shiaofen Fang, Vijay R. Ramakrishnan
similarity 0.62
Abstract

Clinical prediction can saturate for two different reasons: a fitted learner may fail to extract available information, or the recorded variables may impose a population frontier. We separate these quantities through the \emph{learner gap} and the \emph{measurement-channel ceiling}. Optimal balanced accuracy is characterized by total-variation separation, yielding architecture invariance, a sharp partial-identification result under replacement contamination, a cross-fitted ceiling estimator, and exact conditions for multimodal decision improvement. We add two finite-sample diagnostics, namely a label-permutation optimism floor and an underfit curve, and validate the audit on three real cohorts: UCI readmission ($n=99{,}343$), BRFSS diabetes ($n=253{,}680$), and NHANES HbA1c ($n=10{,}219$). Well-tuned gradient boosting nearly reaches the estimated frontier in UCI and BRFSS, whereas deliberately or practically deficient learners retain large gaps. NHANES yields a null difference between questionnaire and measured marginal frontiers but a significant joint complementarity gain, refining the simplistic claim that an objective modality must dominate. Across all cohorts, modest AUROC gains coexist with substantially larger Bayes decision-flip rates, and several architectures estimate similar frontiers while their achieved balanced accuracy differs sharply. A PRISMA-guided synthesis of 104 clinical tasks then shows that the same channel-level regularities recur across more than 18 disease categories: a broad but non-universal structured-clinical region, diminishing same-channel gains across model families, and higher performance when measurement channels change. The framework converts saturation from an empirical observation into an auditable decision: improve the learner when headroom remains; improve measurement when it does not.

0.18

Severity-Controlled Prediction Sets for Medication Recommendation

cs.LG stat.APstat.ML ·2026-11-09 ·Yu Gu, Zijun Yu, Chi-Kuang Yeh, Xinyu Wang, Ziyang Song
top venuecode/data similarity 0.61
Abstract · Accepted to NeurIPS 2026. Camera-ready version. Code: https://github.com/ggggggyyyyyy/conformal-severity-control

Medication recommendation is a multi-label prediction task. However, existing prediction-set evaluation and calibration methods rely mainly on exact-overlap metrics and therefore treat all missed medications as equally severe, overlooking how closely the prediction set matches them within the medication hierarchy. To address this, we introduce Conformal Severity Control (CSC), a post-hoc framework for calibrating medication prediction sets under hierarchy-aware mismatch severity. CSC uses the Anatomical Therapeutic Chemical (ATC) hierarchy to quantify mismatch severity and controls patient-level severity without retraining the predictor, supporting both average severity and upper-quantile severity for the highest-severity mismatches. Experiments on MIMIC-IV show that CSC tracks user-specified severity tolerances and shifts prediction sets away from distant mismatches toward exact or close matches.

0.63

When uncertainty quantification fails: structural vulnerabilities and corrections for selective prediction under clinical class imbalance

cs.LG cs.AI ·2026-10-27 ·Walter Endrizzi, Flavio Ragni, Raffaele Marchesi, Stefano Bovo, Monica Moroni +2 more
code/data similarity 0.61
Abstract · https://github.com/endrwalter/uncertainty_ml

Background. Selective prediction systems improve the safety of clinical artificial intelligence by deferring ambiguous cases to human experts while automating high-confidence decisions. However, this safety mechanism relies entirely on the premise that uncertainty scores accurately reflect clinical ambiguity. In prognostic tasks characterized by severe class imbalance, where the clinical outcome of interest is a minority, this assumption breaks down. Standard uncertainty measures cease to capture clinically aligned ambiguity; instead, they become a proxy for class membership, systematically penalizing minority patients regardless of their individual predictive clarity. Results. Across 56 synthetic conditions and three neurodegenerative cohorts spanning severe class imbalance to near-balanced conditions (multiple sclerosis, Parkinson's Disease, Alzheimer's Disease), our framework consistently maintained bounded, balanced risk across trajectories. In contrast, global metrics either collapsed minority Sensitivity or protected the minority at the expense of majority patients. Applying CCR with standard entropy fails to protect the minority because it breaks within-class monotonicity when tau=0.5. Combining CCR with threshold-aware metrics restores strict monotonicity, correctly identifies ambiguous patients, and safely mitigates minority exclusion. Conclusions. Under clinical class imbalance, standard uncertainty quantification measures dataset sparsity rather than clinical ambiguity, creating a systemic illusion of safety. This bias is a correctable structural flaw. Clinical pipelines deploying selective prediction under imbalance should adopt threshold-aligned uncertainty measures and class-stratified evaluation. This reduces class-specific risk imbalance, supporting safer selective prediction under the evaluated conditions without silently excluding the most vulnerable patients.

0.31

Hidden Data Challenges in Clinical Machine Learning

cs.LG ·2026-10-09 ·Carolin Cissée, Dennis Fast, Raneen Younis, Alexander Löser, Wolfgang Nejdl +1 more
code/data similarity 0.60
Abstract

Widely reused preprocessing pipelines for electronic health records can encode assumptions about when information became available, what clinical episode a label represents, and what missingness means. These assumptions are rarely audited systematically and may propagate across subsequent studies when preprocessing pipelines are reused or adapted. Using MIMIC-IV as a case study, we identify and quantify violations of three complementary forms of preprocessing alignment, i.e., temporal, semantic, and population alignment, which manifest as temporal leakage, feature-task misalignment, and biased imputation. We show how ambiguities in timestamp semantics, episode definitions, endpoint construction, modality selection, and missingness handling can alter the information available to a model and affect the interpretation of its predictions. Through analyses of MIMIC-IV data and empirical case studies, we demonstrate that such choices may remain largely invisible in aggregate predictive performance while changing the signals on which models rely. We derive practical recommendations for temporally valid, clinically aligned, and reproducible preprocessing of MIMIC-IV and related electronic health record datasets. The code for our experiments, including our proposed preprocessing, is available at: https://github.com/m2l-lab/mimic-iv-preprocess.

0.22

Local Discrimination of Binary Classifiers via Localized AUC Functional

cs.LG stat.ML ·2026-10-22 ·Wenye Ren, Anna Győrffy-Kerekes, Tancredi Dorsi, Olga Demler
similarity 0.60
Abstract

Risk prediction models are frequently evaluated with AUC, which means that during evaluation we are blind to performance heterogeneity, which could lead to bad decision-making in clinics. In this work, we aim to change that by identifying patient cohorts for whom the risk prediction model might not be an accurate predictor. To separate these cohorts, we use a version of the weighted AUC, which we call Localized AUC or LAUC. Using this metric, we build a method that we coin LOCATOR. This method is able to identify cohorts of patients for whom the risk prediction model is inaccurate. We test this method both in real-world data and in simulations. We also build a statistical background for the use of Localized AUC for our purposes.

0.22

Trajectory-Guided Steering: Mitigating Spurious Feature Bias in Clinical Classification

cs.CL ·2026-10-15 ·Fardin Ahsan Sakib, Ziwei Zhu, Ozlem Uzuner
similarity 0.60
Abstract

Large language models rely on spurious features in clinical classification: swapping a single gender token in clinical notes alters gender-irrelevant diagnoses in up to 53.5% of cases. Existing inference-time corrections either need counterfactual data built around the specific spurious feature or behave unpredictably. We observe that how a model's preference between answers evolves across layers, its prediction trajectory, indicates for each document whether a correction is likely to help. We propose Trajectory-Guided Steering (TGS), which decides from the trajectory alone whether to correct each prediction and in which direction, with no counterfactual data and no knowledge of the spurious feature. On 16 clinical classification tasks from i2b2, TGS fixes 17.7% of errors while breaking only 1.3% of correct predictions and stays net-positive across all tested hyperparameter settings; all baselines are net-negative or near zero. The same corrections reduce reliance on the spurious feature: on the most affected diseases, gender-swap inconsistency falls sharply (hypertension 53.5% -> 38.0%, diabetes 35.1% -> 21.5%). Applying the correction to every document instead raises breaks on correct positive predictions from 0.1% to 6.4%, so per-document selection is essential. TGS also transfers to three model families and three other clinical and biomedical datasets.

0.22

Detecting Unreliable Classifications from Quantized Models

cs.CV ·2026-10-13 ·Ananya Kotla, Jorge T. Gomez
hot direction similarity 0.59
Abstract · 1 figure, 5 tables

Post-training INT8 quantization is typically validated by checking accuracy retention, which requires ground-truth labels often unavailable in low-resource clinical settings. We show a label-free alternative: comparing a model's own output before and after quantization. We compute cosine similarity between the FP32 and INT8 models' output probability vectors for each prediction, which requires only a single forward pass. This output-agreement similarity separates lower-accuracy predictions across four evaluated architectures (ResNet-50, VGG-16-BN, Wide ResNet-50, and ViT-B/16) under fixed-percentile splits, outperforming a confidence-only baseline for all four. These results show that quantized models can be compared to their baselines to assess their drift and determine whether they are well suited for clinical deployment.

0.31