CS Paper Radar

Benchmarking and Improvement of Artifact Segmentation Methods in H&E-Stained Whole Slide Imaging

Julia Merta, Daniel Mendelsohn, Benedikt Schoser, Joanna Polanska, Michal Marczyk

eess.IV cs.CV ·submitted 2026-10-16 12:03 UTC · v1
benchmarkcode/data

Abstract

Technical artifacts introduced during tissue preparation or slide scanning remain a major obstacle to developing robust computational pathology algorithms for hematoxylin and eosin (HE)-stained whole-slide images (WSIs). Despite the growing number of quality-control tools, their real-world utility remains hard to assess because of the limited number of publicly available implementations and the lack of systematic, multi-dataset comparisons. This paper presents a benchmark of artifact segmentation methods for HE-stained WSIs. After a literature review, six publicly available algorithms were selected and compared in terms of their ability to segment artifact-free tissue and selected artifact classes. Two publicly available datasets and a newly introduced dataset released to support further research were used for evaluation. Tissue samples from multiple medical centers and different organs are included, enabling evaluation across heterogeneous data sources. Segmentation performance was assessed using Dice Index, pixel-level recall, and false discovery rate for artifact-free tissue segmentation. For algorithms supporting multiclass artifact segmentation, class-wise Dice Index and inter-class misclassification were evaluated. In addition to segmentation quality, processing time was assessed. Statistical analysis revealed significant differences in segmentation performance between methods. HistoKit, which incorporates a modified version of the GrandQC, was identified as the best-performing algorithm, while HistoQC was the worst. In terms of artifact types, dark spots and out of focus regions were harder to segment than others. Finally, a simple post-processing step was introduced for HistoKit, which further improved segmentation performance. The benchmark establishes a reference for evaluating and developing artifact segmentation methods for HE-stained WSIs.

Closest papers

Nearest neighbours by meaning across the whole index.

Reliable Benchmarking of Artifact Detection in Computational Pathology: A Reproducibility and Uncertainty Analysis

cs.CV cs.AI ·2026-08-31 ·Konstantinos Moutselos, Ilias Maglogiannis
similarity 0.65
Abstract · 5 figures

Background and Objective: Quality control is a prerequisite for whole-slide image analysis, yet the benchmarks on which quality-control methods are compared share four properties that make their reported differences hard to interpret: few independent slides, annotation concentrated in a minority of them, pooled ratio metrics with no closed-form standard error, and a single inherited train/test partition. We propose a reliability protocol for such benchmarks. Methods: The protocol quantifies four sources of variability - test-set sampling, training stochasticity, partition composition, and undocumented preprocessing - a claim is reportable only if it survives all four; three of the four cost minutes of compute. We apply it to an independent reconstruction of a published diffusion-based artifact detector, evaluated on the original 24-slide partition and against a supervised baseline. Results: The method's central mechanism reproduces: the auxiliary contrastive term improves pooled F1 from 0.673 to 0.688 and replicates under a second seed (+0.0156, p = 0.031; +0.0190, p = 0.005), although it acts on pen marking rather than the artifact types cited to motivate it. Its comparative claims do not: differences between design variants, and against the supervised baseline, fall inside the uncertainty of the evaluation. Four of 24 slides carry 70% of scored annotated pixels, giving an effective sample size of 6.2, and the inherited partition sits at the 7th percentile. An unreported tissue-restriction step excludes 41.4% of out-of-focus annotation against 2.6% of air bubble; such a gate is confounded with blur by construction. Conclusions: Small-cohort benchmarks support far weaker conclusions than current reporting implies. The four checks are cheap enough to accompany any evaluation on such a resource and separate reproducible effects from differences the evaluation cannot resolve.

0.55

The APL Doesn't Fall Far From The Tree: Unsupervised Artefact Prototype Learning in Histopathology

cs.CV ·2026-11-06 ·Emilia Agasi, Charlie Gourley, C. Simon Herrington, Robert L. Hollis, T. Ian Simpson
similarity 0.65
Abstract

Histopathology foundation models provide rich representations of tissue morphology, but technical artefacts in whole slide images introduce noise that may impact diagnostic accuracy. We introduce Artefact Prototype Learning (APL), a novel approach to detecting these artefacts that exploits the geometry of pre-trained embedding spaces without manual labels or fine-tuning. Rather than treating artefacts as isolated outliers, APL computes prototypes of out-of-distribution patches and uses them to distinguish artefact-associated patterns from tissue. Evaluation on a single-centre dataset shows that APL outperforms prior methods GrandQC and HistoART in detecting artefacts such as blur, dark spots, slide edges and pen marks, but struggles with tissue folds and blood. These results show that frozen pre-trained embeddings already carry information that allows artefact detection without expensive labels or vast computational resources.

0.20

The BRIDGE dataset: paired brightfield whole-slide images of prostate core-needle biopsies in paraffin, after deparaffinization and H&E staining

cs.CV ·2026-11-10 ·Julia A. Mielcarz, Justyna Durślewicz, Marek Zdrenka, Ahmad Abbadi, Martin Eklund +3 more
dataset similarity 0.63
Abstract

Computational approaches are increasingly being explored to streamline histopathology workflows, including label-free methods that aim to reduce reliance on chemical staining. Among these, deep learning-based label-free virtual staining uses images of unstained tissue to computationally generate stained images. Despite growing interest, model development and validation remain constrained by the scarcity of paired, clinically annotated whole-slide imaging datasets. We present BRIDGE, a dataset of prostate core-needle biopsies collected at the Prof. Franciszek Lukaszczyk Oncology Centre in Bydgoszcz, Poland. The dataset comprises 869 glass slides from 169 patients, each digitized sequentially after sectioning, deparaffinization, and hematoxylin and eosin staining, yielding in total 2607 whole-slide images. The dataset supports the development and external validation of label-free virtual staining, virtual unstaining, image-registration and segmentation methods. Each slide is accompanied by a Gleason score, enabling downstream analyses of cancer classification and grading concordance. The stained images can be used independently for color normalization and cross-scanner robustness studies. All images are de-identified, distributed in their native scanner format and will be available through the BioImage Archive.

0.18

PathXAI: Evidence-guided structured pathology reporting by transferable tissue segmentation

cs.CV cs.CL ·2026-11-06 ·Zhaorui Tan, Jun Aun Tan, Weixiang Zhong, Xiaoxi Wang, Tan Pan +5 more
similarity 0.61
Abstract · More experimental results will be added in the future version

Pathology reporting translates tissue observations across regions and slides into diagnoses and supporting morphological descriptions, yet explicit tissue-composition measurements are rarely used to guide H&E-based report generation. We developed PathXAI, which pairs transferable tissue segmentation with a pretrained vision-language model. Because supplying tissue information directly with H&E images gave limited benefit, PathXAI-Report uses segmentation overlays and tissue statistics in separate steps, selects between candidate diagnoses by fixed rules, acquires further images when evidence is insufficient and records every step for review, without updating model weights. Its segmentation component exceeded baselines in mean Dice on internal and external tests. In automated evaluation on 1,200 public and 151 private cases, PathXAI achieved higher agreement with reference diagnoses and documented morphology than H&E-based comparators. On the public cohort, it exceeded Qwen+H&E by 4.4 percentage points in cancer family match rate and 5.7 percentage points in finding F1.

0.25

BigCell: Generating Gigapixel Whole-Slide Images

cs.CV cs.LG ·2026-10-09 ·Srikar Yellapragada, Alexandros Graikos, Zilinghan Li, Kostas Triaridis, Tarak Nath Nandi +8 more
top venuecode/data similarity 0.61
Abstract · Accepted at NeurIPS 2026. Project page: https://histodiffusion.github.io/docs/projects/bigcell/

Whole-slide images (WSIs) are gigapixel-scale digital scans of histopathology tissue and serve as the primary basis for cancer diagnosis. Existing histopathology generative models operate at the patch scale, producing fixed-size tiles of at most 1024$\times$1024 pixels which encompass only a small fraction of the WSI. In contrast, text reports for clinical diagnoses and slide-level diagnostic labels -- the supervision that exists at scale -- operate at the whole-slide level. We present BigCell, the first approach to generate coherent whole-slide histopathology images at native gigapixel resolution. BigCell trains a flow-matching transformer at 2048$\times$2048 pixels on over 120,000 publicly available WSIs spanning multiple organ types. Conditioning on embeddings from pathology foundation models and using an inference-time sliding-window pipeline, BigCell generates coherent images of up to 32,768$\times$32,768 pixels, outperforming prior tile generators on both tile-level and slide-level fidelity metrics. To make gigapixel synthesis practical, we introduce an adaptive scheduling strategy that prioritizes important slide regions, speeding up image generation by over 3\ttimes with minimal quality degradation. Furthermore, we propose the first text-to-image synthesis at 8k resolution by training a separate model that produces dense conditioning grids directly from pathology text reports. We demonstrate that augmenting with synthetic samples improves slide-level few-shot classification performance by up to $18 \%$ over baselines trained on real data.

0.45

MUFASA: An Information Utility-Aware Preprocessing Framework for Reliable Model Reasoning in Computational Pathology

cs.CE ·2026-08-31 ·Rathinaraja Jeyaraj, Barathi Subramanian, Songmi Noh, Mitchell N. Peterson, Terry Guo +5 more
similarity 0.60
Abstract · 28 pages, 10 figures, 7 tables

Reliable computational pathology depends on preprocessing methods that identify informative tissue regions while excluding artifacts and low-utility regions from whole-slide images (WSI). However, existing preprocessing pipelines often retain such regions or discard diagnostically relevant tissue, thereby limiting downstream model performance, reliability, and robustness across heterogeneous cohorts. Here, we systematically evaluate how these regions affect downstream AI model performance across multiple clinically relevant applications and introduce MUFASA, a generalizable, information utility-aware preprocessing framework for H&E-stained WSI that excludes artifacts and low-utility regions while preserving biologically meaningful tissue. MUFASA integrates slide-level artifact masking, stain-aware tile filtering, reconstruction-based utility stratification of tiles, and targeted recovery of tissue tiles that are over-filtered by earlier phases. Across tumor diagnosis, tumor subtyping, biomarker status prediction, and survival prognostication tasks in diverse cancer cohorts, MUFASA consistently improves downstream model performance relative to widely used preprocessing baselines. These gains are accompanied by reduced artifact-associated attribution in model heatmaps, indicating improved alignment between retained tissue and model attention. Our findings establish WSI preprocessing as a critical determinant of downstream model performance and validity, revealing that even accurate predictions can conceal important failure modes stemming from anatomically implausible reasoning driven by retained artifact-containing and low information-utility tiles.

0.21

The Effect of Tissue Detection on False Positives of Diffusion-Based Artifact Detection in Histopathology

eess.IV cs.CV ·2026-09-30 ·Konstantinos Moutselos, Ilias Maglogiannis
similarity 0.59
Abstract · 29 pages, 3 figures, 4 tables, including supplementary material. Code, data and models: https://doi.org/10.5281/zenodo.23016733

One-class artifact detectors for whole-slide images learn normal tissue from a clean training pool and flag departures from it. The pool is built by a preprocessing pipeline whose tissue-detection step is usually treated as neutral. We tested whether it is. On 16 annotated slides from The Cancer Genome Atlas, we rebuilt the clean pool of a diffusion-based detector with different tissue detection methods and compared the resulting models in a four-fold cross-validation. Per-slide saturation-Otsu detection excluded normal tissue, chiefly tissue with large clear spaces such as adipose tissue and alveolar parenchyma, and on slides with thick marker ink kept the ink while excluding ordinary tissue. Replacing it with entropy-based detection reduced the false-positive fraction on held-out clean slides from 0.102 to 0.016, in every fold and with a second training seed, without loss of sensitivity; the gain came from the composition of the pool, not its size. Across three tissue detection methods, false positives followed the fraction of such clear-space tissue in the pool, a statistic that needs no labels or training (0.103, 0.016 and 0.009). The effect did not carry over at the same size to a nearest-neighbour detector on foundation-model features. On an external cohort, the curated pool lowered clean-control false positives by about 20%, far less than on the development slides, and the remaining cross-center loss was not explained by stain differences. For one-class quality control, tissue detection decides what the model learns as normal and should be chosen and reported accordingly.

0.31

Computationally Efficient Pathology Segmentation using Knowledge Distillation from Foundation Models

eess.IV ·2026-09-03 ·Jiaqi Lv, Yijie Zhu, Saki Okada, Maxwell Stanley Renna, Robert Goldin +2 more
similarity 0.59
Abstract · Submitted to Medical Image Analysis

Automatic tissue segmentation is essential for large-scale analysis of histopathology whole-slide images (WSIs), but accurate pixel-level segmentation remains challenging. Pixel-level annotations are expensive to obtain, models pre-trained on natural images may transfer poorly to histopathology, and pathology foundation models, despite their strong representations, are computationally expensive to deploy at scale. We address these challenges with a foundation-model knowledge distillation framework for efficient tissue segmentation. We first train Virchow2-based segmentation teachers, including a LoRA-adapted variant, achieving state-of-the-art or highly competitive performance across four datasets: PUMA, IGNITE, BEETLE, and a private blood vessel segmentation dataset. We then transfer response-level and feature-level knowledge from these teachers into compact student networks. Distillation consistently improves student performance over supervised training alone, producing state-of-the-art or near state-of-the-art results with substantially fewer parameters and up to ten-fold higher inference throughput than foundation-model-based segmentation networks. These results show that foundation-model knowledge can be effectively transferred to efficient segmentation models for scalable deployment without compromising performance. Models trained on the public datasets will be released through TIAToolbox.

0.35