CS Paper Radar

Medical Fine-Tuning Reshapes, Not Reduces, Patient-Facing AI Risk: A Rubric-Based, LLM-Judge Evaluation Framework

Savan Doshi

cs.AI cs.CL ·submitted 2026-10-17 18:24 UTC · v1
benchmark

Abstract

Patient-facing medical question answering with large language models (LLMs) is moving from research demonstrations to production deployments, yet evaluation remains anchored on factual correctness. Factuality is necessary but not sufficient: a response can be factually grounded and still issue a directive that, if acted on, would harm the patient. We introduce a risk-sensitive evaluation framework that scores responses by the presence and severity of six categories of risk-bearing language (treatment directives, contraindications, dosage expressions, urgency-triage cues, high-alert medication mentions, and overconfident assertions), anchored on published clinical harm taxonomies. Severity is classified by a three-judge LLM ensemble. We apply this framework to six 7-9B instruction-tuned models, three general (Mistral-7B, Phi-3.5-mini, Llama-3.1-8B) and three medically adapted (BioMistral-7B, OpenBioLLM-Llama3-8B, Med42-Llama3-8B), on 200 real patient questions from the K-QA benchmark. Two findings emerge. First, ensemble risk-bearing language is statistically independent of factual hallucination rate (pooled Spearman $ρ= -0.065$, $n = 300$, 95% CI $[-0.18, +0.05]$; distance correlation $= 0.10$, independence test $p = 0.24$). Second, medical fine-tuning does not reduce aggregate risk but reshapes it: continued-pretraining adaptations (BioMistral, OpenBioLLM) consistently suppress high-alert medication mentions while amplifying overconfident assertions, whereas clinical instruction-tuning (Med42) suppresses dosing only, without amplifying overconfidence. Per-category Krippendorff $α$ is fair to good for the four linguistically anchored categories (0.53-0.71) and low for the two clinical-judgment-dependent categories (0.19, 0.31), indicating where automatic safety evaluation is and is not yet reliable. We release the rubric, judge prompts, and evaluation code.

Closest papers

Nearest neighbours by meaning across the whole index.

A Proposed Rubric for Evaluating Expressed Clinical Reasoning in Large Language Model Responses

cs.CL cs.AI ·2026-09-29 ·Zhangshu Joshua Jiang, Zina Ibrahim, James T. Teo
similarity 0.73
Abstract · 23 pages

We propose a rubric for assessing expressed clinical reasoning in model responses, drawing on three bodies of work: medical education assessment frameworks (ART, SCT, Key Feature Problems and OSCE); clinical LLM benchmarks (MedR-Bench, HealthBench, TIMER-Bench, DR. BENCH, PrIME-LLM and PatientSafeBench); and general LLM reasoning evaluation research, including the Factuality-Validity-Coherence-Utility taxonomy, FaithCoT-Bench and C2-Faith. We use groundedness as a clinically oriented adaptation of the taxonomy's factuality category. The rubric brings these concepts together in a multidimensional framework for scoring free-text responses to gold-standard clinical vignettes. It includes provisional behavioural anchors, applicability rules and a separate flag for case-specific safety-critical errors. General-domain frameworks inform its design but are not treated as validated clinical instruments. The rubric does not replace case-specific reference criteria or the task-specific metrics of existing benchmarks. It has not yet been tested for inter-rater reliability, construct validity or clinical utility. Its immediate purpose is to make evaluation decisions explicit and open to scrutiny before empirical testing.

0.26

DocTalk: Enhancing Medical Knowledge Retrieval via Fine-tuned Large Language Models with Chain-of-Thought Reasoning for Robust Clinical Decision Support

cs.AI cs.CLcs.CV ·2026-10-26 ·Asad Gohar, Md Ariful Islam Mozumder, Moon-Il Joo, Hee-Cheol Kim
code/data similarity 0.70
Abstract

Objective: The rapid advancement of large language models (LLMs) in healthcare has opened new possibilities for AI-assisted clinical decision-making; however, safe and effective deployment remains challenging because of hallucination and domain misalignment. This study introduces DocTalk, a doctor-assistive question-answering (QA) system designed to generate concise, chart-grounded responses from de-identified discharge summaries. Methods: We developed a high-fidelity data generation pipeline that produces 500 clinically relevant QA pairs through sentence-level decomposition, chain-of-thought-guided question formulation, and expert review. Six open-source LLMs, including three general-purpose and three biomedical models, were evaluated before and after parameter-efficient instruction tuning using Low-Rank Adaptation (LoRA). The framework integrates prompt engineering, in-context learning, and medically aligned evaluation to support factual and interpretable responses. Results: On DocTalk-QA, instruction tuning produced consistent improvements across lexical, semantic, and clinical fidelity metrics. The best-performing tuned model, Llama-3-Med42-8B, achieved ROUGE-L = 0.40, BERTScore-F1 = 0.76, and UMLS-F1 = 0.49. To examine external generalization beyond the DocTalk-QA dataset, the two best-performing models, Llama-3.1-8B-Instruct and Llama-3-Med42-8B, were evaluated on PubMedQA before and after instruction tuning. Accuracy improved from 0.931 to 0.977 for Llama-3.1-8B-Instruct and from 0.935 to 0.943 for Llama-3-Med42-8B. Conclusion: DocTalk was deployed as a secure web-based platform for interactive EHR querying. These findings suggest that clinically grounded instruction tuning can improve medical QA performance and support practical clinical decision support.

0.26

TAF-MED: Multi-Turn Safety Refusal Collapse in LLMs Under Declared Self-Treatment Intent

cs.CL cs.AI ·2026-08-10 ·Waleed Jamil, Raphael Schmitt
benchmark similarity 0.70
Abstract

Large language models (LLMs) increasingly provide conversational health information that may influence treatment decisions, yet existing benchmarks do not isolate whether medication-safety boundaries persist across follow-ups after explicit self-treatment intent. We introduce TAF-MED, a physician-reviewed benchmark of 500 fixed three-turn scenarios, and evaluate eight LLMs across 4,000 conversations. A rubric-based automated judge labelled responses as SAFE, LEAKY, or UNSAFE, and two physicians independently annotated a model-balanced random subset of 400 conversations. We assessed unsafe guidance, collapse after a strictly SAFE initial response, and model-ranking stability. Overall, 71.6% of conversations contained an UNSAFE response, and 61.4% of those beginning with a strictly SAFE response later collapsed to UNSAFE; model-level collapse rates ranged from 24.4% to 96.2%. Four of 28 model pairs reversed order between initial unsafe and collapse rates. Automated labels achieved 94.3% agreement with the adjudicated physician reference ($κ= 0.895$). These findings show that first-turn safety is an incomplete proxy for conversational safety persistence and motivate evaluation across complete dialogue trajectories. We will release TAF-MED on Hugging Face to support reproducible research on multi-turn medical safety.

0.04

When Confidence Fails: Overconfidence in LLMs under Uncertainty and Missing Clinical Information

cs.CL cs.AIcs.HCcs.LG ·2026-08-10 ·Maryam Tahermazandarani, Adnan Mahmood, Fahmida Islam, Quan Z. Sheng
published similarity 0.70
Abstract

Large Language Models (LLMs) have achieved strong performance in medical question answering and clinical reasoning tasks. However, their reliability under uncertainty remains poorly understood which raises critical concerns for deployment in high-stakes clinical settings. In such environments, incorrect predictions are inherently risky, but confident incorrect predictions can be particularly harmful as they may mislead clinical decision-making. In this paper, we conduct a systematic behavioral analysis of LLMs under clinical information uncertainty. We propose an evaluation framework based on the MedMCQA dataset consisting of two complementary uncertainty settings. First, we introduce linguistic uncertainty cues through prompt modifications to simulate ambiguous clinical contexts. Second, we construct an answer removal setting, wherein the correct option is deliberately excluded mandating the model to recognize insufficient information and abstain. We analyze both model accuracy and confidence behavior using multiple calibration metrics including calibration gap, Expected Calibration Error (ECE), and Unsafe Confident Error Rate (UCER) across 500 medical questions. Our results reveal a consistent failure mode, i.e., although accuracy degrades under increasing uncertainty, model confidence remains misaligned with accuracy. This leads to a substantial increase in unsafe confident errors, indicating that model confidence remains largely insensitive to clinically meaningful information loss. Furthermore, we observe significant variation across models in their ability to abstain when the correct answer is unavailable, with some models persistently producing high confidence hallucinated answers. These findings expose critical limitations in the epistemic reliability of current LLMs and highlight the need for uncertainty aware evaluation methods prior to their deployment in clinical workflows.

0.22

Unknown is not normal: separating language-model extraction from rule-based decision logic for clinical risk scores

cs.CL cs.AI ·2026-09-28 ·Nicolás Vera Zúñiga
code/data similarity 0.69
Abstract · 14 pages (7 of main text), 5 figures, 2 tables, appendix included; full supplementary material in the code repository. Code: https://github.…

Large language models (LLMs) are increasingly used to compute clinical risk scores from free-text notes. Notes are often incomplete, and treating undocumented findings as normal can silently misclassify patients. We test whether separating three-state extraction (present, absent or unknown, by an LLM) from decision logic (deterministic code computing score bounds over unknown inputs) lets a system ask only questions that can change the decision. On 1,200 synthetic emergency cases across six calculators (HEART, CURB-65, qSOFA, PERC, Wells, Cockcroft-Gault), with a simulated clinician answering questions, we compared this bounds policy with asking for every missing input, a missing-equals-normal schema, and an end-to-end LLM agent (Claude Opus 5.5). With Claude Haiku 4.5 as extractor, the bounds policy matched ask-all accuracy (99.4% vs 99.4%) with half the questions (0.92 vs 1.78 per case) and no irrelevant ones. Treating missing as normal dropped accuracy to 91.2% and under-triaged 8.5% of patients (95% CI 7.1-10.2), and under-triage persisted under messy notes and a noisy clinician. The agent was equally accurate under ideal conditions (99.6%) but 9.5% of its questions were irrelevant; with a noisy clinician it was less accurate than the bounds policy (83.5% vs 87.0%, p<0.001) and committed prematurely in 2.7% of cases (bounds: 0%). A 9B local model as extractor reached oracle-level accuracy (99.8%). In 584 real case reports from MedCalc-Bench, only 52% contained enough information to determine the category (HEART 13%). Routing decisions through code that reasons explicitly about unknowns avoids premature commitment and irrelevant questions, halves the questions asked, and works with small local models.

0.36

Safety-Preserving Medical LLM Fine-Tuning via Bilevel Data Selection

cs.CL cs.AIcs.LG ·2026-11-16 ·Ruoxuan Shi, Sheng Yang, Zhengxing Su, Xiaoyang Hou, Yating Liu
similarity 0.69
Abstract

As general large language models (LLMs) are increasingly adapted for patient-facing medical applications, improving medical capability while controlling patient-facing risks remains a critical challenge. Large-scale medical instruction data are essential for acquiring domain knowledge through supervised fine-tuning (SFT), but unsafe responses can undermine existing safety alignment. To address this problem, we propose Scalable Bilevel Data Selection (S-BDS) for safety-preserving medical SFT. By controlling selection-weight concentration, S-BDS enables reliable sample ranking over large candidate pools and identifies training examples that improve medical capability while controlling patient-facing risks. We combine clinician-validated safe data and selected data with unscreened medical instruction data for SFT, and jointly evaluate medical capability and patient-facing safety on HealthBench and PatientSafetyBench, respectively. Experiments across Llama and Qwen models show that S-BDS achieves the highest safe rates among all compared methods, outperforming the strongest baselines by 4.64 and 3.00 percentage points, respectively, while maintaining competitive medical capability. Further experiments show that varying the safety-oriented weight during SFT controls the trade-off between medical capability and patient-facing safety.

0.23

MedConstBench: Benchmarking How Constitutions Steer LLMs in Medical Ethics

cs.AI cs.CL ·2026-10-27 ·Yibo Yang, Zerui Huang, Haomiao Yang, Zixia Wang
benchmarkcode/data similarity 0.69
Abstract · 8 pages, 3 figures, 8 tables

As large language models advance rapidly, they are increasingly used to answer medical questions, and many such models are now deployed locally. Once a model is deployed, its behavior is governed mainly by the ethical policy written into its constitution. However, most existing work focuses on factual correctness rather than the trade-off between competing ethical values. Even benchmarks that do evaluate ethics treat it as a fixed property of the model rather than as a variable, so how a constitution reshapes medical-ethics behavior remains largely unexplored. We introduce MedConstBench, a medical-ethics benchmark that treats the deployment constitution as a controlled variable, is organized around Beauchamp's four principles, and is scored by human-calibrated multi-model peer review. It includes MedDilemma, our own dataset of clinical dilemmas, and supports a systematic analysis of how constitutions steer LLMs. Evaluating ten open-source LLMs under four constitutions, we find that the effect of a constitution is dimension-selective and model-dependent, and that no constitution is universally optimal. Motivated by these findings, we propose a do-no-harm adaptive selector that chooses a constitution per model, matching the per-model oracle while guaranteeing a worst-case floor and generalizing to unseen models at low cost.

0.25

AI Consilium: a Benchmark of LLM Clinical Multidisciplinary Second Opinions

cs.CL cs.AI ·2026-10-15 ·Alexey A. Bokov, Ivan I. Panin, Nikolay B. Nechaev, Mikhail Yu. Valkov, Valeria Yu. Chernina +8 more
benchmark similarity 0.69
Abstract

Large language models (LLMs) can generate differential diagnoses for complex cases, but a useful second opinion must also be factually grounded, clinically coherent, actionable, and safe. We developed a multidimensional benchmark using 300 diagnostically resolved NEJM--MedQA cases: 110 for physician reference ratings and Judge calibration and 190 for held-out evaluation. Eight single-model pipelines generated independent role-specific opinions and interactive-consilium reports under free-form and structured clinical-reasoning conditions. A physician-calibrated LLM Judge evaluated 3,040 final reports and the corresponding structured primary-role outputs. Model identity separated report quality more strongly than response format. Structured final reports had higher overall mean scores in seven of eight model pipelines, with their clearest advantage in management (2.740 vs. 2.436). Compared with the structured pre-consilium primary-role opinion, the complete structured synthesis had higher pooled scores across all five shared criteria, with the largest increases in problem prioritization, factual grounding, and reasoning coherence. GPT-5.6-Sol led every evaluated component and reached consensus in the fewest review rounds. These findings show that the benchmark can distinguish model capability, the contribution of multidisciplinary synthesis, criterion-specific effects of response structure, deliberation dynamics, and inference requirements within one common-case evaluation.

0.24