CS Paper Radar

Do We Need the Largest LLMs for Every Clinical Decision?

Ali H. Lazem, William Teahan

cs.CL ·submitted 2026-10-17 22:07 UTC · v1
hot direction

Abstract

Large clinical language models often require multi-GPU infrastructure, limiting local deployment. We introduce CERTA, a decision-level statistical certificate that determines when a quantized model may substitute for its native BF16 reference and escalates decisions that cannot be certified to it. Across eleven instruction-tuned models, both general-purpose and domain-adapted, from three families (7-72B), we evaluated 2,500 clinical-verification decisions from de-identified patient contexts (2,484 patients), with patient-disjoint calibration and testing. In the higher-power operational analysis, round-to-nearest 8-bit quantization at BF16 storage served 99.8-100% of held-out decisions across all eleven models; formal finite-sample guarantees were assessed separately using the exact split-sample procedure. In the same operational analysis, the class-conditional 4-bit frontier reduced the amortized, BF16-equivalent deployment cost to 25.8% and 27.3% of the BF16 reference for Qwen2.5-72B and HuatuoGPT-o1-72B, respectively, with measured peak memory of 43.0 and 42.7 GB, below the nominal capacity of a single 48 GB accelerator. Deployment on that specific hardware was not directly tested. Under the exact split-sample certificate, which also accounts for configuration selection, these costs were 26.7% and 27.9%. On external disease named-entity benchmarks against human annotations, the frontier-selected NF4 configurations had a mean absolute F1 change of 0.045 on both datasets, with substantial model-specific variation. CERTA converts compression from a fixed precision choice into a risk-controlled deployment policy for this verification task.

Closest papers

Nearest neighbours by meaning across the whole index.

The Effect of Quantization on Clinical Benchmarks: Accuracy and Safety Across Model Families

cs.LG cs.CL ·2026-09-02 ·Leonard Twagirayezu, Prasenjit Mitra
similarity 0.72
Abstract

Quantization enables deployment of large language models on resource-constrained clinical edge devices, but its effect on clinical accuracy and safety remains understudied. We evaluate five 7-8B parameter models at FP16, GPTQ-INT8, and GPTQ-INT4 precision across five benchmarks: MedQA, MedMCQA, Med-HALT, a risk-stratified sample of HealthBench, and MedSafetyBench. The study jointly varies quantization bit width, model family, and clinical task type, with explicit risk stratification and safety measures. INT8 GPTQ is universally safe (max. degradation -1.9%-1.9%), while INT4 degradation is substantial and model-dependent: BioMistral-7B, clinically fine-tuned, loses 19.7% on MedMCQA, more than any general-purpose model, showing clinical fine-tuning does not confer compression robustness. MedMCQA degrades more than MedQA under INT4; Med-HALT is largely unaffected. On HealthBench's emergency-risk subgroup, Qwen2.5-7B degrades by 26.8% under INT4, suggesting high-risk scenarios are disproportionately vulnerable to compression. On MedSafetyBench, the model family dominates over precision (refusal rates range 10.2%-74.9% at FP16), though Qwen2.5-7B (-17.8%) and Meditron-7B (-28.3%) show substantial INT4 safety degradation; notably, Qwen2.5-7B is simultaneously the most accuracy-robust model, demonstrating that accuracy and safety robustness are independent properties. We additionally test two recovery methods, clinical calibration substitution and QLoRA fine-tuning, both producing the same trade-off: MedMCQA recovers while MedQA further degrades, indicating recovery strategies require task-specific validation rather than being assumed universally beneficial. These findings indicate INT8 is broadly safe for clinical deployment, while INT4 safety must be assessed per-model and per-task, and that safety alignment is determined primarily by instruction tuning rather than clinical domain adaptation.

0.30

Behavioral Capacity Certificates for Quantized Language Models

cs.LG ·2026-09-29 ·Arian Eamaz, Mojtaba Soltanalian
code/data similarity 0.63
Abstract · 43 pages, including appendices. Code: https://github.com/eamaz/bcc

Activation and key-value cache precision change what a quantized language model computes without altering its stored weights. Direct weight-code bounds, however, assign identical complexity to deployments that behave differently and charge separately for weight codes that behave identically. Behavioral Capacity Certificates (BCC) charge for behavior using the aggregate prior mass of complete implementations---weights, scales, activation and cache rules---that induce the same bounded loss. When quantization merges implementations, this shared mass lowers the complexity penalty, and a break-even law determines when the saving survives the cost of validating it. BCC supports a three-step deployment workflow, and our experiments verify each step. First, a forward-only screen shortlists per-layer bit-widths by how often candidate perturbations preserve the reference predictions, with quality comparable to Hessian-guided selection at lower preprocessing cost. Second, margin-certified cells identify weights that can be pruned or sign-flipped without changing the deployed behavior: every permitted combination preserves all declared predictions, and on OLMoE-1B-7B and SmolLM2-1.7B, independent probes bound the probability that any permitted combination changes a prediction on new text. Third, BCC bounds the population loss of the deployed model, nonvacuously for complete decoders and more tightly than the compressed-code route. At equal cache memory, giving keys higher precision than values yields lower NLL and higher prediction agreement on GPT-2, Qwen2.5, and SmolLM2, together with a tighter complexity bound in the GPT-2 audit.

0.32

Capacity over TFLOPS: Memory-Centric Deployment of Large Clinical Language Models on Consumer CPUs

cs.DC ·2026-10-13 ·Eli Yune, Umer Majeed, Mahesh Balan
publishedpositioncode/data similarity 0.61
Abstract · 6 pages, 4 figures. Accepted to the 2026 IEEE 15th International Conference on Consumer Electronics - Berlin (ICCE-Berlin). (c) 2026 IEEE. C…

The dominant barrier to running large clinical language models at the point of care is not arithmetic throughput but graphics memory: consumer GPUs cap at 4-16 GB, while the working set of a 27-billion-parameter model in 4-bit precision is 17-25 GB. We argue that the edge node should be treated as capacity-enabled (system RAM) rather than compute-limited (GPU VRAM), and we test this on commodity hardware. Using an INT4 build of a 27B open model as an architecture-faithful stand-in for a 27B medical model, we measure the memory footprint, inference latency, energy, and federated communication cost of a fully CPU-based pipeline driven by synthetic Fast Healthcare Interoperability Resources (FHIR) prompts. On two independent consumer machines (a desktop-class machine with 67 GB of RAM and a 6 GB GPU, and a mobile workstation with 34 GB of RAM and a 4 GB GPU) the model loads entirely into system RAM (37% and 60% utilization, respectively) while both GPUs are out-of-memory before the first step. Inference runs at overnight-batch speed (0.6-2.4 tokens/s for the 27B model), and federated fine-tuning would transmit only a 22.6 MB low-rank adapter, a 99.96% reduction over full weights. The capacity result is independent of CPU microarchitecture, RAM size, operating system, and GPU. We further identify an open, CPU- and NPU-optimized inference runtime as the natural production path for this approach, indicating a privacy-preserving and broadly deployable route for on-premises clinical AI. All data is synthetic; this is a research artifact and not a medical device.

0.50

Towards a Deterministic Math Solver for Clinical Language Models

cs.AI cs.SE ·2026-09-09 ·Felipe Ocampo Osorio, Sebastián Andrés Cajas Ordoñez, Maximin Lange, Rafi Al Attrach, Sahil Kapadia +3 more
benchmark similarity 0.61
Abstract

Large language models are unreliable at arithmetic, which is a problem for clinical calculators where a single numerical error changes the recommendation. The standard response is to hardcode each calculator as a validated function, one at a time. We test an alternative: the model does not calculate. Instead, it writes case-specific Python that a restricted local executor runs as a deterministic solver, and the model's task reduces to deciding how to use it. We evaluate this Program-Solve interface on MedCalc-Bench Verified (1,100 cases, 55 calculators) against direct model arithmetic and a hand-written 22-calculator library, using Qwen2.5-7B and Qwen2.5-32B-AWQ, after auditing the benchmark's formulas against current clinical guidelines and flagging 16 of 55 with version, use or coefficient concerns. With formulas and gold variables supplied and both routes reading the whole note, handing off to the solver is not a reliable advantage at 7B (75.31% against 72.02%, a paired +3.29 points with a 95% calculator-cluster interval of [-3.49, 10.38]) but is one at 32B (90.53% against 83.47%, +7.05 [0.47, 14.60], clear of zero). The hand-written library is exact on its 440 supported cases but abstains elsewhere (40.0% overall). Adding an executor thus helps some open-weight models more than others even under matched formula, variable and note access, and is not a substitute for verified formulas or reliable variable extraction either way.

0.21

Making every stage of medical device document assessment with large language models deterministic

cs.CL cs.IR ·2026-10-15 ·Ryosuke Suzuki
similarity 0.60
Abstract · 30 pages, 3 figures, 3 tables; supplementary tables S1-S15 and two supplementary notes included

To show that a medical device complies with regulation, experts judge whether documents and records meet each requirement and record the judgment for others to verify. For each assessment item that experts define, large language models could prepare a preliminary assessment: a label such as Satisfied or Not satisfied, a reason and quoted evidence. We sent fourteen commercial deployments of such models (seven models from three providers, through six routes) the same request repeatedly, with the deterministic sampling settings each accepted; every deployment returned differing assessments for at least one request, and in twelve the label changed. Reducing reasoning where the interface allows it did not reduce the variation, and prompts of retrieved passages removed it only for the smallest models. The same open-weight model was reproducible or not depending only on how it was served. A pipeline we built to be deterministic at every stage -- text extraction and optical character recognition (OCR), chunking, embedding, indexing, retrieval and inference -- returned byte-identical output at each stage across reruns, interruptions, edits, machines of one graphics processing unit (GPU) model and days, for blood glucose meter and infusion pump documents. OCR, embedding and approximate retrieval varied when their own serving was not made invariant, and outputs changed with the GPU model and with the inference engine's scheduling settings, which therefore belong in the recorded configuration. End-to-end determinism is achievable and gives a testable basis for audit and change control.

0.24

Democratizing Clinical Tumor Whole Genome Sequencing: 18-hour End-to-end Analysis via Trillion-parameter Large Language Models Locally Deployed on Consumer-grade Hardware

cs.LG q-bio.GN ·2026-09-14 ·Rui Xiao, Yili Xu
similarity 0.60
Abstract · 11 pages. Corresponding author: Yili Xu(22465225@qq.com)

Whole genome sequencing (WGS) is essential for precision oncology, yet its clinical adoption remains limited by prohibitive computational costs and multi-day turnaround times. This work presents a fully localized low-resource framework enabling stable deployment of a trillion-parameter biomedical LLM on a single consumer-grade RTX 4060 laptop with 32GB system memory and 8GB VRAM, as well as on routine clinical workstations in general hospitals, completing the entire tumor-paired WGS workflow from raw FASTQ input to clinical-grade full-variation-spectrum report output. Under standard 30X depth configurations, our implementation finishes a single tumor-paired WGS analysis within 18 hours, achieving 99.62% F1 score for somatic variant detection with over 99.9% concordance to the industrial-standard A100 cluster pipeline, fully meeting clinical oncology accuracy requirements. Quantitative profiling shows adaptive heterogeneous memory scheduling accounts for 71% of total execution time, while model optimization introduces less than 9% of total detection error. This work is the first engineering implementation of trillion-parameter biomedical LLM-driven clinical-grade genomic analysis on consumer-grade hardware, breaking the industry paradigm that trillion-scale genomic LLMs require hundred-thousand-dollar GPU clusters and multi-day turnaround, establishing a low-resource pathway for global primary medical institutions to adopt whole-genome precision oncology at zero additional cost.

0.12

From Small to Large: Assessing Medical Reasoning, Benchmark Contamination, and Model Size in Language Models

cs.AI cs.CL ·2026-10-30 ·Navapat Nananukul, Mayank Kejriwal
benchmark similarity 0.60
Abstract

Large language models (LLMs) now answer medical exam questions at or above expert level, but it is unclear whether such scores reflect clinical competence, or are instead affected by the format of the questions being asked (e.g., multiple-choice versus open-ended), prior exposure to the benchmarks, and the difficulty of the questions. These benchmarks are also public and widely used online, which may be resulting in LLM memorization. Models may perform better on questions that they have seen before. It is also not evident whether smaller models, which are more locally deployable in HIPAA-compliant hospital settings, have achieved human performance. In this study, we evaluate fourteen current models from six leading providers, one smaller and one larger model from each provider with two additional open-weight models, on 3,076 questions from four medical benchmarks (MedQA-USMLE, MedMCQA, PubMedQA, and MedBullets) under standard multiple choice, the same questions with the answer choices withheld, and reconstruction of a hidden question from its choices alone. In the standard multiple-choice setting, the strongest models exceed the human-expert baseline on MedQA-USMLE and PubMedQA, but the smaller models trail their larger models by 8.7 percentage points and only two of the six pass the human-expert bar on the licensing examination. Withholding the answer choices, however, makes every model struggle: mean accuracy falls from 82.3% to 50.9%, and the two largest drops belong to the medically specialised models. On memorization, the strongest models reconstruct one question in four from the answer choices alone, yet accuracy holds on the questions they cannot reconstruct. We further weigh accuracy against inference cost and test whether ensembling several models improves medical question answering.

0.15

Quantization Amplifies Determinism, Not Bias: Scale-Dependent Behavioral Effects of Serving-Time Weight Compression

cs.AI ·2026-09-07 ·Dachi Kurtskhalia
similarity 0.59
Abstract · 8 pages, 3 figures. Under review at the NeurIPS 2026 Workshop on Deployable Small Foundation Models (LIGHT)

Weight quantization largely determines the economics of serving open-weight LLMs. Its costs are usually assessed with capability benchmarks, on which 4-bit quantization of mid-sized models is often considered "nearly free." We examine a different question: when several answers are valid, does quantization change what a model chooses to say? We serve three checkpoints (Qwen3-8B/14B/32B) at three weight precisions (W4A16 AWQ, W8A16 FP8-Marlin, and bf16), holding the hardware, software, and sampling configuration constant, and collect approximately 71,000 completions paired by prompt and seed across two custom, leak-checked prompt batteries. We pre-specified the analyses in three waves in version control. At 8B, int4 reduces output diversity: the probability that two samples for the same scenario recommend the same brand increases by 5.1 percentage points (prompt-paired sign-flip test, Holm p = .023; reproduced at +4.4pp on a full regeneration of the arm), and lexical diversity falls substantially (TTR -0.011, standardized effect -0.51; robust to a length-controlled measure). At 14B and 32B, no content-concentration measure reaches significance; instead, stylistic drift emerges (em-dash rate +0.46/1k words at 14B and +0.61/1k at 32B, both Holm p <= .0024). Pre-specified tests of stereotype direction are null at every scale: outputs concentrate on the modal answer for each prompt rather than on stereotypical answers. Mechanistically, the token-level distribution becomes flatter (decision-token entropy +0.091 bits, p = .015) while the semantic distribution, measured directly from first-token log probabilities, becomes more concentrated (collision +2.6pp, p = .023): individual tokens become less predictable even as meanings become more repetitive. At 8B, the smallest size tested, AWQ-int4 serving measurably narrows the range of suggestions; audits should assess concentration as well as bias.

0.17