CS Paper Radar

CPVB-RG: Cross-Prior Visual Bridging for Prior-Aware Chest X-Ray Report Generation

Sike Xiang, Shuang Chen, Julie Cox, Amir Atapour-Abarghouei

cs.CV ·submitted 2026-10-20 14:38 UTC · v1
publishedhot direction

Abstract

Radiologists interpret follow-up chest X-rays by comparing current and prior examinations to identify new, resolved or progressing findings. Most report generation systems either omit this longitudinal context or fuse prior features without distinguishing interval changes from anatomy that remains stable over time. We propose CPVB-RG, a prior-aware framework that combines current and prior radiographs with available clinical text. Its Cross-Prior Visual Bridge (CPVB) contains Progression-Guided Focus Attention (PGFA) and two Cross-Attention units. PGFA is designed to contrast progression-difference attention with shared-spatial attention, aiming to reduce invariant responses whilst retaining coarse spatial correspondence between examinations. The Cross-Attention units then connect the resulting longitudinal visual evidence with clinical semantics. CPVB-RG is trained in two stages, using prior-guided image-text alignment followed by autoregressive report generation with a lightweight language decoder. Experiments on MIMIC-CXR and IU X-Ray show consistent improvements across language and clinical metrics. On MIMIC-CXR, CPVB-RG achieves 0.2847 F1RadGraph and 0.6692 VLScore, with statistically significant gains over the closest decoder-matched prior-aware baseline. These results support the effectiveness of the proposed difference-aware and spatially guided fusion design for prior-aware chest X-ray report generation.

Comment
Accepted at WACV 2027

Closest papers

Nearest neighbours by meaning across the whole index.

ICGF-CXRMate: Image-Conditioned Clinical Context Compression and Gated Fusion for Chest X-ray Report Generation

cs.CV ·2026-10-22 ·Vu Minh Tran, Thuc Huynh, Son Thanh Luu, Doanh C. Bui
similarity 0.75
Abstract

Auxiliary patient data can improve chest X-ray report generation, but directly concatenating heterogeneous clinical information with visual tokens produces long, variable-length decoder prompts and may expose the model to redundant or image-irrelevant context. We propose ICGF-CXRMate, an image-conditioned clinical context compression and gated fusion framework. Learnable queries are first conditioned on the current chest X-ray representations and then attend to the patient-data sequence, compressing it into a fixed number of clinical context tokens. Gated cross-attention selectively integrates these tokens into the visual stream, while the compressed tokens are retained in the decoder prompt as a direct clinical pathway. Experiments on linked MIMIC-CXR and MIMIC-IV-ED examinations show that ICGF-CXRMate improves report quality while reducing the average prompt length. In Stage~2, it improves RadGraph-F1 from 24.00 to 28.86, CXR-BERT similarity from 56.86 to 62.80, and BLEU-4 from 5.14 to 7.96 compared with CXRMate-ED, while reducing the average prompt length from 373.89 to 288.37 tokens, corresponding to a 22.9\% reduction. After self-critical sequence training, ICGF-CXRMate outperforms CXRMate-ED on six of eight report-quality metrics in Stage~3. Ablation studies confirm the complementary contributions of image-conditioned compression, gated fusion, and direct retention of the compressed clinical tokens.

0.17

CheXGround: Anatomical Region Tokens for Grounded Longitudinal Chest X-ray Interpretation

cs.CV ·2026-08-31 ·Adonay Demewez Gebremedhin, Wessam Shehieb, Sara Alansari, Mohamad Alansari, Muzammal Naseer +2 more
publishedcode/data similarity 0.75
Abstract · Accepted for publication at the 37th British Machine Vision Conference (BMVC2026)

Recent radiology multi-modal language models have made substantial progress in chest X-ray report generation, visual question answering, and temporal reasoning. While longitudinal chest X-ray interpretation compares sequential examinations to describe change, visual grounding aims to connect clinical language with localized image evidence. Although longitudinal modeling and visual grounding have each advanced radiology language models, how localized visual evidence can support longitudinal interpretation remains under-explored. We introduce CheXGround, a region-grounded longitudinal chest X-ray language model that represents paired studies through corresponding anatomical regions. CheXGround extracts anatomical regions from current and prior radiographs, encodes them as temporally enhanced Region-of-Interest (ROI) tokens, and combines them with global temporal image context during generation. To connect these region tokens with clinical text, we propose Temporal Region--Phrase Alignment, a pretraining objective that aligns temporal anatomical representations with localized report phrases. We evaluate CheXGround on single-study and longitudinal Visual Question Answering (VQA), longitudinal findings generation, temporal grounded VQA, and anatomical grounding. Across these tasks, CheXGround improves clinical language quality, temporal reasoning, and localization accuracy over recent baselines. Our results suggest that organizing longitudinal evidence at the anatomical level is a strong representation for grounded radiology language modeling. Project page: https://adonaydem.github.io/chexground-website

0.38

CliQ-RRG: Clinical-Knowledge Guided Disease-aware Visual-Textual Alignment for QA-Style Radiology Report Generation

cs.CL ·2026-10-09 ·Chandravardhan Singh Raghaw, Shahid Shafi Dar, Arnav Nishith Sharma, Shrey Modi, Nagendra Kumar
top venuecode/data similarity 0.72
Abstract · Accepted: EMNLP Findings 2026

Radiology reports are essential for diagnostic reasoning and patient care, yet their manual preparation is time-consuming and cognitively demanding. Automatic radiology report generation (RRG) offers a scalable alternative, but existing models often produce lengthy, unstructured narratives that overlook diagnostic cues and multi-view information. We present Clinical-Knowledge Guided Disease-aware Visual-Textual Alignment for QA-Style Radiology Report Generation (CliQ-RRG), a unified two-stage framework for interpretable and clinically grounded reporting. In Stage 1, CliQ-RRG employs a Disease-aware Visual-Textual Alignment module that aligns image and text representations using predicted disease embeddings, reinforced by a Prior-Guided Attention Module (PrAM) to capture multi-view dependencies across current and prior scans. In Stage 2, GraphRAG-guided retrieval augments intermediate textual representations with graph-grounded clinical evidence, and a large language model restructures them into concise, interpretable question-answer (QA) pairs with diagnostic summaries. Experiments on two public chest X-ray benchmarks demonstrate that CliQ-RRG consistently outperforms prior methods across both lexical and clinical metrics, generating accurate and clinically coherent QA-style radiology reports. Code is available at: https://github.com/chandravardhan-singh-raghaw/CliQ-RRG.

0.38

Anatomy-Structured Hierarchical MIL for Weakly-Supervised Thoracic Disease Detection in Chest X-rays

cs.CV ·2026-09-27 ·Jeongin Kim, Sohyun Ahn, Seo Young Kang, Jaeyi Sung, Soomin Kim +4 more
top venuecode/data similarity 0.71
Abstract · Accepted at MICCAI 2026

Weakly-supervised thoracic disease detection in chest X-rays (CXR) is challenging due to subtle appearances and complex anatomical overlap, motivating anatomy-aware modeling for improved localization. However, prior anatomy-aware methods typically rely on coarse region proxies or static spatial priors, which may restrict dynamic instance discovery and limit precise localization of small abnormalities. We propose Anatomy-Structured Hierarchical Multiple Instance Learning (ASH-MIL), a framework that introduces parallel anatomy-structured observation branches (cardiac, pulmonary, and agnostic) combined with hierarchical MIL aggregation. Anatomical priors are injected as soft spatial biases into decoder cross-attention, enabling anatomically grounded evidence maps without disease bounding-box supervision. Instance localization is derived directly from MIL-weighted cross-attention maps without bounding box supervision. Experiments on CXR8 and cross-domain MIMIC-CXR held-out sets demonstrate consistent improvements over prior weakly-supervised and anatomy-aware approaches, particularly under stricter localization criteria. Our code is available at https://github.com/jn-kim/ash-mil.

0.44

CoRE: Relating Fine-Grained Chest X-ray Findings in Anatomical Context

eess.IV ·2026-10-22 ·Minjun Kim, Jong Hak Moon
similarity 0.71
Abstract · 18 pages, 3 figures

Chest X-ray interpretation depends on both the anatomical location of findings and their relationships with other abnormalities. However, relations defined over global finding labels do not explicitly distinguish the same finding across anatomical locations. We propose CoRE(Co-occurrence-guided Region Evidence), a framework that incorporates relationships among findings and anatomical context into fine-grained chest X-ray prediction. It groups anatomical region-finding labels by co-occurrence and uses these groups to guide shared representation learning through visual prompt tuning on a frozen vision transformer. The predictions are supplemented by an anatomically supervised region-evidence stream through region-matched logit residuals. Experiments on MIMIC-CXR with Chest ImaGenome annotations show that CoRE improves region-finding classification over standard and relation-aware prompt-based baselines. Quantitative evaluations on MS-CXR and the Chest ImaGenome gold standard show improved finding localization, supported by qualitative comparisons. CoRE also improves finding-level classification on mapped finding labels in external VinDr-CXR and CheXpert datasets without target-domain adaptation. These results demonstrate the value of jointly modeling finding relationships and anatomical context for fine-grained chest X-ray analysis.

0.21

SentZero: An Enhanced Sentence-Centric Vision-Language Pretraining for Multi-Task Zero-Shot Chest X-Ray Analysis

cs.CV cs.AI ·2026-09-28 ·Hangyul Yoon, Hyungyung Lee, Edward Choi, Eunho Yang
similarity 0.70
Abstract

Vision-language (VL) pretraining using paired chest X-ray (CXR) images and radiology reports has shown strong potential for medical image understanding. However, existing methods often remain dependent on task-specific finetuning because radiology reports are lengthy, clinically dense, and difficult to align with simple zero-shot prompts. Recent sentence-level approaches partially address this limitation using clinical phrases extracted by large language models (LLMs), but they largely overlook the intrinsic characteristics of radiology discourse. In particular, limited positive-pair diversity constrains further gains, while clinically equivalent sentences frequently recur across patients, creating false negatives in contrastive learning. To address these issues, we propose SentZero, an enhanced sentence-centric VL pretraining framework for zero-shot, multi-task CXR analysis. SentZero introduces LLM-based abstract-level sentence structuring and mapping to expand positive-pair diversity, together with an additional loss term to mitigate false negatives. We further introduce sentence-conditioned residual modulation of visual embeddings, enabling visual features to adapt to the semantic characteristics of each input sentence. Across diverse downstream tasks and datasets, SentZero improves zero-shot generalization and outperforms prior multi-task zero-shot methods.

0.16

Carving Radiology Reports at Their Evidential Joints: Anatomical Region Sets as Generation Units

cs.CL cs.CV ·2026-10-21 ·Jinwei Yang, Junhao Chen, Jianwei Zhao, Zhonghan Xu, Hong Cheng +1 more
similarity 0.70
Abstract · 28 pages, 4 figures

Organizing radiology reports into independently generated units offers a way to generate fine-grained clinical content and bind it to visual evidence. However, existing methods typically adopt generation-unit structures not directly specified in natural reports or their annotations, introducing additional modeling compromises. We propose RadCarve, which instead defines generation units directly from the anatomical region sets in existing statement-region correspondences, unifying unit formation with visual evidence selection. RadCarve's planner uses composition-specialized query banks to jointly predict unit existence and region composition from the image, iteratively refining both with regional evidence aggregated according to current membership predictions. The generator independently produces each unit's text conditioned on the joint visual evidence of its predicted region set. Compared with strong baselines, RadCarve improves CXRFEScore by 9.4% in unit generation given region sets and achieves 2.4 times the end-to-end binding F1. It also achieves leading report-generation results on Chest ImaGenome and PadChest-GR, using fewer than one-sixth as many parameters as large-scale baselines.

0.28

Diagnosis-Conditioned Spatial Gating and Decoder-Level Supervised Contrastive Learning for Radiology Report Generation

cs.CV ·2026-10-03 ·Md Mustafizur Rahman, Mylene C. Q. Farias
similarity 0.70
Abstract · 5 pages. Manuscript submitted to ICASSP 2027

Radiology report generation models can produce fluent text while still containing finding-level inaccuracies. Diagnosis-driven methods improve generation by conditioning on predicted findings, but these predictions do not directly modify the visual patch features provided to the decoder, and global gating applies the same modulation across spatial locations. We introduce a Position-Aware Gate (PAG) that uses predicted finding representations to modulate visual patches spatially without region supervision. We also propose a Decoder-level Supervised Contrastive Loss (DSCL) that structures decoder representations using shared positive findings rather than instance identity. On MIMIC-CXR, PAG+DSCL improves clinical efficacy (CE) F1 from 0.484 to 0.502 over a matched global-gate reference, while PAG and DSCL individually reach 0.491 and 0.495. Without additional fine-tuning, the combined model achieves 0.226 CE F1 on IU X-Ray, compared with 0.211 reported by PromptMRG.

0.27