CS Paper Radar

BRIDGE: An Acceptance Gate to Block False Improvements in Model Updates, with a Retrospective Clinical Evaluation

Dwi Sunaryono

cs.LG stat.ML ·submitted 2026-10-21 10:04 UTC · v2
theoryunusual

Abstract

Models are updated repeatedly, and an update that looks better on validation data but not on new data is a false improvement that can misguide clinical decisions. The naive rule accepts every positive validation gain and is optimistic when the same data choose and judge the update. BRIDGE is a model-agnostic acceptance gate that decides each update from predictions and the available labels, with fixed settings. Each fold of the data judges the update chosen on the other folds (cross-fitting) to reduce selection bias; acceptance requires the gain's lower bootstrap bound to exceed a margin. The four settings are (A) 11 new datasets, (B) synthetic tasks, (C) 12 retrospective clinical tasks, and (D) 39 supporting datasets. The false-improvement rate falls from 19.1% (naive) to 1.1% (BRIDGE) in (A), 20.7% to 1.7% (B), 20.0% to 0% (C), and 12.5% to 0.5% (D); every 95% confidence interval of the reduction over datasets or tasks excludes zero (not over the clinical sources). An equal-size random draw from the naive acceptances contains more false improvements in (A)-(E) (post hoc, p<0.001). On the OpenML collection (E) of 14 new datasets, the false-improvement rate falls from 25.6% to 1.0%. BRIDGE removes 97% to 100% of the false improvements that the naive rule accepts, and its mean gain per deployed update is 1.8 to 3.1 times the naive rule's. The 95% upper bound on the false-improvement rate is below 5.5%: formal in (B) for independent tasks (3.56%), and conditional on the real data tested (0.33% to 5.40%).

Comment
40 pages, 5 figures. Code and data: https://doi.org/10.5281/zenodo.23523984

Closest papers

Nearest neighbours by meaning across the whole index.

ChainCheck: Near-Perfect Evidence-Sufficiency Scores Can Conceal Sensitivity to Construction Artifacts -- Paired Conditional Contrasts that Expose an Evaluation Confound

cs.AI ·2026-11-09 ·Hyojung Han, Ryangkyung Kang, Youngeun Kim, Seung-Hun Jeon
similarity 0.55
Abstract · 30 pages, 11 tables, 6 figures

Evidence-sufficiency benchmarks ask whether a model can tell a complete passage set from one whose reasoning chain is broken. When broken sets are made by editing text, near-perfect sufficiency scores--and even positive crossed-control scores--need not demonstrate multi-hop reasoning. We present ChainCheck, an evaluation-validity audit that pairs validator-certified counterfactual cells with artifact-only baselines. In an exploratory crossed control on 2,214 HotpotQA pairs, a language-model scorer that never reads the chain reaches a nominal AUC of 0.997, and a one-string match reaches the maximum of the crossed chain-sensitivity statistic CS4 (0.500), while the 11 evaluated systems score from 0.308 to 0.484; the two statistics are different metrics. We therefore read positive CS4 as operational bridge-consistency sensitivity, not as semantic multi-hop reasoning. Every system is also sensitive to one extra edit, and the edits are detectable according to model-based naturalness ratings. On an independent HotpotQA set of 2,276 pairs, patterns pre-specified on MuSiQue and 2WikiMultiHopQA did not replicate: 5 of 6 trained readouts were edit-dominated, and the reference judge's selectivity interval [-0.007, +0.042] includes zero. Judge scores also depended on batch layout. The MuSiQue and 2Wiki records are public; the HotpotQA records and the fine-tuned checkpoints are not, so external reproduction is partial.

0.13

Decide, Ask, or Defer: Clinical LLMs under Incomplete Evidence

cs.AI ·2026-10-03 ·Mingzhan Yang, Weili Wu
published similarity 0.54
Abstract · Accepted to the Main Track of the NeurIPS 2026 GenAI4Health Workshop

Clinical LLMs must decide not only what diagnosis to produce, but also whether the available evidence is sufficient for autonomous decision making. Binary DECIDE/ABSTAIN formulations merge distinct non decision states and do not explicitly evaluate information acquisition. We introduce a DECIDE/ASK/DEFER formulation together with a blinded protocol that prevents models from using evidence completeness metadata. We evaluate Qwen, Gemini, and GPT on 200 matched clinical evidence states constructed from DDXPlus. The models show substantial differences in action selection under identical evidence, with disagreement in 137 of 200 states. For Qwen, a matched targeted versus random analysis shows that selected information changes the likelihood of a subsequent autonomous decision more clearly than diagnostic correctness. Its matched DECIDE/ABSTAIN baseline further reveals a safety autonomy tradeoff: the three action policy rescues some erroneous autonomous decisions but also removes some correct autonomous deci sions. These results show that separating information acquisition from clinician deferral exposes behavior that binary abstention hides, without yielding a uniformly improved decision policy.

0.31

Does Your Trial Simulator Know What the Drug Does? An Intervention-Blind Test of Interventional Validity on 7,207 Registered Trials

cs.AI stat.APcs.LG ·2026-11-04 ·Alicem Koyun
publishedbenchmarktheorycode/data similarity 0.54
Abstract · Oral presentation at the NeurIPS 2026 Workshop on World Models for High-Stakes Health. 31 pages, 5 figures. Code and data: https://github.co…

Patient world models are increasingly proposed as simulators of clinical trials, and recent surveys rank their capabilities on a ladder from temporal prediction to counterfactual rollouts. Position on that ladder is currently assigned by reading papers rather than by measurement. We turn the counterfactual rung into a measured quantity. From 30,119 completed phase 2/3 trials with results posted to ClinicalTrials.gov we construct 9,996 audited within-trial contrasts from 7,207 trials, and we score a simulator on how much of its accuracy depends on knowing which intervention was tested. The instrument is an intervention-blind reference: the same model, trained on the same trials, with every intervention-identifying field withheld. Interventional skill is the error the full model removes relative to that reference. On a temporal split (878 test contrasts from 655 trials) a registry-trained gradient-boosting simulator removes a fifth of the error of a trivial baseline, but its interventional skill is -0.12 (95% CI -0.21 to -0.05): withholding the intervention makes it better, and no alternative featurisation, stratum, temporal cut or same-molecule retrieval yields an interval above zero. A frontier language model reading only the registered protocol has interventional skill 0.20 [0.08, 0.31]; smaller and open-weight models sit at the limit of detection. Perturbation tests show the large model uses the intervention as such: swapping the arms reverses the sign of its prediction in 86% of contrasts. The blind reference is itself not drug-blind (a language model recovers the withheld drug class 45% of the time from the blind prompt), so interventional skill is a conservative lower bound. A reliability layer shows that ranking by predicted error lowers it but that calibrated error control does not transfer under temporal shift. Benchmark, code, prompts and per-call model outputs are released.

0.48

Can JEV Support Clinical Trial Criteria Assessment?

cs.LG cs.AIcs.CL ·2026-10-26 ·Mengxian He, Ziyue Gao, Chun Li, Shunyi Zhang, Hao Wei +2 more
hot direction similarity 0.53
Abstract

Clinical trial prescreening requires distinguishing unmet conditions from insufficient evidence in patient records. Given patient records, criterion questions, and predefined answer options, we retrospectively compared JEV, a non-generative decision model returning native option probabilities, with schema-constrained Qwen Flash across 2,048 test patient-condition pairs from TrialGPT and question-answer datasets derived from MIMIC-III and MIMIC-IV, all evaluated under strict Zero Data Retention (ZDR) policies to ensure clinical data privacy. Both models assessed conditions individually or in batches sharing the same patient context, with performance measured against reference labels. In batch mode, JEV and Qwen achieved similar macro-F1 scores on TrialGPT (0.652 vs. 0.660) and MIMIC-IV (0.807 vs. 0.814), whereas JEV substantially outperformed Qwen on MIMIC-III (0.768 vs. 0.534; $Δ$ = +0.234, 95% CI: 0.187-0.281). This advantage largely reflected higher recall for conditions labeled as having insufficient information (56.3% vs. 9.9%). Across all three datasets, JEV also had lower observed median job latency (1.18-1.40 vs. 2.80-8.90 s) and 53%-74% lower estimated cost per condition. These findings position JEV as an initial assessment component that provides criterion-level judgments and flags potential information gaps for review. JEV's observed errors in interpreting clinical evidence underscore the need to verify its outputs against patient records before they inform eligibility decisions.

0.29

Empty Intersection: Provenance Coverage Rose to 98% and Neither Verification Decision Moved

cs.SE ·2026-09-23 ·Dong Hyeon Jeon
similarity 0.53
Abstract · 12 pages

Two structural defenses for provenance, a grade on every row, so that a verification routine cannot mistake the system's own output for an observation, and a single write ingress, so that the grade is enforced rather than merely conventional, were measured against the production deployment that motivated them, over a frozen snapshot of 194,620 rows and the two verification decisions the snapshot supports. Neither reaches either decision. Both were prescribed by a companion paper, which diagnosed that deployment: its verification routines decided outcomes using values the system itself had written. Neither prescription is new: both are established practice in fields that do not cite one another, and no prior work measuring whether either changes a verdict was found, so what is offered here is the measurement and not the prescriptions. Filtering the verification queries by grade turns both decisions from pass to undetermined; widening the grade vocabulary raises classified coverage from 36.1% to 98.4%; a single ingress requiring a grade refuses 3,070 writes. None of the three gives either decision admissible input. The prescriptions do not fail at what they specify. Each is stated over the population and makes no reference to any decision, so neither says which rows a decision will read, and the rows each intervention repairs and the 32 rows the decisions read do not intersect. The intervention that changed the most rows shows the reach most plainly: all 121,296 rows it moved from unnameable to named fall outside both query windows. This paper reports the conditions, measured rather than designed, under which the decisions would have admissible input at all, and notes that the two decisions are blocked for different reasons.

0.37

VFR-Audit: Verdict-Level Reliability for Fairness Audits in Hospital Length-of-Stay Prediction

cs.AI ·2026-08-31 ·Md Jannatul Rakib Joy, Viet Vo, Caslon Chua
top venue similarity 0.53
Abstract · 12 pages, 5 figures. Accepted at the 35th ACM International Conference on Information and Knowledge Management (CIKM 2026)

Fairness audits in clinical Artificial Intelligence convert continuous fairness metrics into binary pass-or-fail verdicts against operational thresholds, where hospital governance boards, payers, and regulators act on the resulting verdicts. Such audits are repeated over time and across hospital sites, thus the same verdict can flip between pass and fail across audits. Existing uncertainty methods such as Bayesian posteriors, bootstrap confidence intervals, and permutation tests address verdict instability only at the continuous-metric level. Converting metric-level uncertainty into a verdict-stability claim remains a manual step that scales poorly across the (model, metric, attribute) cells an audit covers. Existing uncertainty methods also leave open whether bias-mitigation steps, such as reweighing or per-group threshold shifts, yield a stable passing verdict at the cost of model discrimination measured as AUROC or AUPRC.To address this verdict-stability gap, we propose VFR-Audit, a framework built around the Verdict Flip Rate (VFR), a scalar bounded between 0 and 0.5 that measures the probability of verdict reversal under stratified bootstrap resampling. VFR-Audit reports VFR alongside three reliability axes, namely within-cohort resampling stability, audit-size sensitivity, and cross-hospital verdict agreement via Fleiss' kappa.

0.36

Right Diagnoses, Decorative Reasoning:A Perturbation Audit of Medical Chain-of-Thought

cs.AI ·2026-08-25 ·Mengzhu Xu, Jifan Gao, Xia Jiang, Yaoxin Wu, Xi Long
top venue similarity 0.53
Abstract

Clinicians read chain-of-thought (CoT) rationales as evidence of medical reasoning, but whether the visible chain plays that role is rarely tested. General-domain CoT-faithfulness probes ignore clinical cost, and medical LLM evaluations treat the chain as a black box. We close this gap with a medical perturbation audit: a 30-operator battery edits both the chain and the question with clinically motivated operators (severity reversal, negation flip, demographic swap, evidence ablation), paired with a chain-update times answer-flip joint analysis that classifies each model by its failure mode. Applied to 14 LLMs on four medical QA benchmarks, three independent tests converge: the Chain-Decoupling Rate (CDR; chain does not register the edit and the answer does not flip) is 72.9% panel-wide on clinically meaningful destructive edits, chain corruption leaves accuracy unchanged, and removing CoT prompting does not reduce accuracy. Two board-certified clinicians re-annotate N=197 perturbed questions; 98.5% leave the gold defensible. The pattern holds across medical and reasoning fine-tuning and scale; on the closed-source tier, where the chain text is unavailable, the answer-side signals are consistent with the same decoupling. Our framework and CDR provide a reusable yardstick for auditing whether medical CoT is faithful or merely documentation.

0.73

Auditing Escalation Reliability in Healthcare LLM Agents: A Perturbation-Controlled Benchmark of Workflow-State Failures

cs.AI cs.CL ·2026-10-15 ·Zihao Zheng, Junyi Yao, Baichuan Li, Jiayu Long
benchmark similarity 0.53
Abstract · 8 pages, 5 figures

Trustworthy biomedical AI requires reliable action selection when evidence is missing, stale, conflicting, or late, not only accurate answers on static inputs. We instantiate an episode-level evaluation protocol as 400 synthetic healthcare workflow episodes: 40 hand-authored semantic seeds across four task classes, two surface parameterizations, and five controlled variants, scored on ANSWER/ASK CLARIFICATION/ABSTAIN/ESCALATE under a pre-declared 5:1 missed-versus-unnecessary escalation cost. Reference actions are single-author study-policy labels, not clinician-adjudicated ground truth. Across five open-weight configurations (1.7B--9.7B), clean decision accuracy reaches 0.97, yet uncertainty-prompted models miss 32--97% of required escalations. The stronger 9.7B configuration narrows but does not remove the gap, falling from 0.97 clean accuracy to 0.78 under conflict. Verbalized confidence is inconsistent (ECE 0.10--0.54; failure AUROC 0.48--0.77), and a development-tuned confidence-only policy yields no utility gain. A transparent workflow-aware controller improves 5:1 utility for every model and reduces missed escalations to 0.12--0.24, at specificity 0.83--0.93. However, a 30-concept lexical stress test reduces each rule detector's recall from 1.00 on trigger phrases to 0.00 on unseen paraphrases, limiting the controller claim to this benchmark. Seed-clustered statistics, ablations, cross-task transfer, raw outputs, and manifests are packaged for audit. The results motivate explicit workflow-state evaluation while showing that apparently effective routing controls need their own generalization tests.

0.46