CS Paper Radar

AquaSense-ICS: A Hybrid Real-Simulated Cyber-Physical Dataset and Leakage-Aware Benchmark for Smart Water Quality Monitoring and Attack Detection

Amal Neji, Mohamed Fourati, Lamia Chaari Fourati

cs.CR ·submitted 2026-10-23 14:06 UTC · v1
benchmarkdatasetcode/data

Abstract

Machine-learning research on water cyber-physical systems (CPS) is constrained by datasets that are either real but chemically poor, or simulated but free of sensing noise and attacks. We present AquaSense-ICS, an open dataset and benchmark that co-registers (i) a 25.4 h recording window (8.0 h of recorded data, 26% coverage) from a Raspberry Pi 5 edge node (TDS probe and BME680 ambient sensor, 1-2 s sampling, 23,688 records), with (ii) a looped network of 13 nodes (10 junctions, 2 reservoirs, 1 tank) simulated in EPANET-MSX for six water-quality species, (iii) a parameterised library of cyber-attacks (false data injection, replay, denial of service, drift) and unintentional sensor faults with sample-level ground truth, and (iv) augmented and TimeGAN-generated sequences, flagged by an origin column. The attack, fault and water-quality labels are traceable to a seeded generator, a documented rule or a simulation input. We show that the most common way of benchmarking such hybrid data, random row splits and labels computed from the input features, yields near-perfect but uninformative scores (macro-F1 = 0.9998 for Random Forest), and we replace it with a leakage-aware protocol using chronological splits and held-out attack types rather than label reconstruction. Under this protocol, no model exceeds the constant "normal" predictor for attack classification (macro-F1 = 0.465), and the best detectors reach a mean AUROC of 0.64 on attack types unseen during training (0.35-0.93 depending on the type), leaving substantial headroom. Data and simulation files are released under CC BY 4.0 at https://doi.org/10.5281/zenodo.23390541, and attack generators and benchmark code under MIT.

Comment
24 pages

Closest papers

Nearest neighbours by meaning across the whole index.

Closing the Applied Cybersecurity Gap in Critical Infrastructure: A Cyber-to-Physical Security Assessment Framework for Water Systems

cs.CR ·2026-10-29 ·Halil Dursunoglu, Kaan Sulkalar
similarity 0.64
Abstract

The integration of information technology and operational technology in water infrastructure creates pathways through which cyber compromise may affect physical service delivery. This study revisits the Applied Cybersecurity Gap (ACG) framework by evaluating an experimental Applied Cybersecurity Gap Index (ACGI) alongside the Cyber-to-Physical Propagation Rate (CPPR), defined as the proportion of initially compromised trials that produce a specified physical-impact outcome. The expanded evaluation comprises 2,160 synthetic trials across three water-network benchmarks, including EPANET Example Network 3 (Net3), and couples declared cyber-attack progression rules with hydraulic simulations. A source-trained machine-learning model evaluated on 247 compromised Net3 trials achieved ROC-AUC 0.772, PR-AUC 0.775, and F1 0.733, compared with 0.661, 0.642, and 0.704 for a scenario-only baseline. The configuration-cluster bootstrap interval for the ROC-AUC difference was 0.038--0.183. A separate 720-run Net3 hydraulic operating-point sensitivity analysis achieved the study's exploratory baseline pressure criterion in all reruns, preserved 717 of 720 physical-impact labels, and produced ROC-AUC 0.791 with the frozen source-trained model. Additional analyses examine the sensitivity of CPPR to the physical-impact threshold and assumed control-blocking probabilities, and demonstrate that the ACGI--CPPR association is partly induced by the simulation design rather than independently validated. The findings establish a reproducible simulation-based assessment workflow, but do not constitute field calibration of cybersecurity-control effectiveness or prediction of real-world utility incidents.

0.32

Robustness of Anomaly Detection Models for Industrial Control Systems under Training-Time Data Contamination

cs.CR cs.LG ·2026-08-24 ·Mustafa Umut Ozbek, Taiwo Ojo, Pooria Madani, Khalil El-Khatib, Li Yang
publishedbenchmarkcode/data similarity 0.62
Abstract · Accepted and to appear in IEEE CASCON 2026. Code is available at: https://github.com/ANTS-OntarioTechU/Robustness-Anomaly-Detection-ICS-Data…

Machine-learning-based anomaly detection is increasingly used in industrial control systems (ICS), yet most studies assume that detector training data is trustworthy. In practice, training data may be corrupted through compromised logs, labeling errors, manipulated historian records, or unsafe retraining processes. This paper evaluates the robustness of offline ICS anomaly-detection pipelines on the Secure Water Treatment (SWaT) benchmark under training-time contamination. We assess 11 heterogeneous anomaly detectors under three contamination strategies: random injection, similarity-targeted injection, and feature-noise injection. The first two insert attack samples into the nominal training pool, while the third adds bounded Gaussian noise to selected normal training samples. These attacks are contamination-based rather than gradient-driven poisoning methods. Contamination budgets from 1% to 10% are evaluated using clean validation and test sets under a unified offline protocol. The results show that robustness is strongly model-dependent and cannot be predicted from clean-data performance alone. Injection-based contamination causes the greatest degradation, particularly for local-density and distance-based detectors, whereas feature-noise contamination has a comparatively limited effect. PCA, SVM, HBOS, and IForest remain relatively stable, while the tuned neural detectors demonstrate intermediate robustness. Overall, the findings highlight the importance of training-data integrity in ML-enabled ICS monitoring, subject to the evaluated dataset, models, and threat assumptions.

0.56

Physics-Attested Federated Learning: Securing Collaborative Anomaly Detection in Critical Water Infrastructure

cs.CR cs.LG ·2026-09-28 ·Jeff Nijsse, Shu Su, Benjamin Oholeguy, Sreenivas Sremath Tirumala
publishedbenchmark similarity 0.60
Abstract · Published in Information

Federated learning enables industrial operators to train shared intrusion detection models without disclosing proprietary operational telemetry. However, existing defences operate strictly in update space, leaving aggregators blind to data poisoning; model updates derived from fabricated telemetry remain indistinguishable from honest contributions. We repurpose process invariants, physical relations that always hold in normal operation, such as conservation of mass, from runtime detection heuristics into a verifiable admission requirement for federated updates, mined automatically from clean operational data. We evaluate this admission gate across two physical water testbeds (SWaT, WADI) and a distribution benchmark (BATADAL), testing seven aggregation rules against telemetry fabrication, exposure-only replay poisoning, and an invariant-aware adaptive adversary. Across three testbeds the mined invariants reject none of 25 honest shards except every cross-channel fabrication on SWaT and BATADAL, including optimised perturbations that the similarity based FoolsGold admits in full. On real telemetry, five mined invariants detect 12 of SWaT's 35 attacks, while nine invariants detect 20. With nine invariants, the admission gate removes 78% of the targeted-attack recall lost to replay poisoning (95% CI 57--97%, $p < 0.001$ over 20 seeds) across five standard aggregators, and 82% under FedAvg. To reconcile physical admission control with federated data privacy, we show invariant compliance using zero-knowledge proofs (zk-SNARKs) to allow clients to prove batch adherence without revealing operational telemetry.

0.41

HydroJEV: A one-second, training-free screen for cyber-attack and fault attribution in water distribution networks

cs.AI ·2026-10-01 ·Tianwei Mu, Shengyan Jiang, Mingzhe Yuan, Qing Luo, Min Xiao +3 more
benchmark similarity 0.60
Abstract · 41 pages, 19 figures

When a SCADA alarm is raised in a water distribution network, operators must decide quickly whether it reflects a cyberattack, a physical fault, a normal transient or a faulty sensor. Supervised classifiers need labelled incidents that utilities rarely have, and frontier large language models (LLMs) take tens of seconds per decision. We tested whether Jev, a training-free model that returns class probabilities in about one second, can serve as the first tier of this triage. On a four-class cause-attribution benchmark built on the C-Town network in EPANET, Jev was compared with a hand-written rule tree, a supervised classifier and seven cloud LLMs on identical evidence in four sealed, pre-registered rounds. With only a label-free prior correction, Jev matched the rule tree (macro-F1 0.62-0.64 against 0.56-0.61 in distribution) and exceeded the supervised classifier by 0.36-0.42 on event subtypes absent from its labels, in all four rounds, and it outperformed the classifier whenever fewer than about four labelled events per class were available. Jev also decided 20-40 times faster than frontier LLMs. Accepting only benign Jev verdicts confirmed by the rule tree spared an LLM reviewer 35-38% of windows on fresh sealed sets without loss of macro-F1. Transferred unchanged to two further networks, this gated cascade stayed within the non-inferiority margin of its reviewer on all four sets. A fast, training-free screen can therefore take over about a third of the review load in SCADA anomaly triage while preserving the accuracy of deliberate review.

0.34

HydroSphere: A Framework for Governed, Self-Healing Wastewater Infrastructure

cs.LG cs.AIcs.CYcs.ET+1 ·2026-09-24 ·Prabu, Fancy C, Suresh A, Srini Ramaswamy
similarity 0.59
Abstract · 16 pages, 5 tables and 9 figures - article to be submitted to a Journal / Conference

Rapid industrialization and urban growth are increasing pressure on water quality and wastewater treatment systems, while conventional treatment plants often rely on static monitoring and control strategies that cannot easily adapt to changing pollutant conditions. This paper presents HydroSphere, a governed, data-driven framework for real-time water quality monitoring, forecasting, treatment optimization, and fault recovery. HydroSphere is evaluated using 2.82 million water-quality measurements collected between 1940 and 2023. The framework integrates three main components. First, a hybrid TCN-LSTM model performs multi-step forecasting across seven water-quality parameters, achieving an RMSE of 0.1417, MAE of 0.1047, and R2 of 0.3596. Second, the Adaptive Dosage Optimization Module uses PPO reinforcement learning to adjust chemical dosing, achieving a mean step reward of 1.059 compared with 1.017 for a fixed-dose baseline. The results also show that unconstrained reward optimization can lead to excessive dosing, demonstrating the need for explicit operational safeguards. Third, the SHADE anomaly detection module uses a deep autoencoder to identify sensor and process anomalies, achieving an F1 score of 0.651 under controlled fault injection. HydroSphere combines these capabilities with tiered governance, deterministic safety bounds, and human oversight to support safer and more adaptive water infrastructure. The framework provides a scalable foundation for intelligent wastewater management and supports the objectives of UN Sustainable Development Goals 6 and 13.

0.33

Reliable Virtual Sensing: A Multi-Domain Benchmark for Robustness Under Sensor Failures

cs.LG cs.AI ·2026-09-16 ·Jens U. Brandt, Noah C. Puetz, Alexander Windmann, Marc Hilbert, Elena Raponi +2 more
benchmarkpositioncode/data similarity 0.56
Abstract

Virtual sensing, the estimation of hard-to-measure quantities from available sensor measurements, is a critical enabler for control and monitoring in cyber-physical systems. However, when sensors fail, learning-based predictors can produce physically implausible estimates that propagate to system-level failures. We argue that real-world deployment demands robustness and introduce MuViS-C, the first multi-domain benchmark of robustness against common sensor failures in learning-based virtual sensing. Building on an existing nominal-performance benchmark and established corruption taxonomies, it covers ten sensor failure modes, from subtle drifts to catastrophic signal dropouts, at multiple severities. These are paired with complementary robustness measures capturing average error under corruption, relative degradation, and worst-case fragility. Across nine datasets from six domains, we benchmark six architectures spanning gradient-boosted trees and the major inductive biases for sequence modeling: convolution, recurrence, attention, and MLP-mixing. On the attention-based architecture, we further probe three robustification strategies. We find that (i) every model degrades substantially under corruption, becoming worse than a naïve predictor on at least one corruption setting, (ii) gradient-boosted tree ensembles achieve strong robustness, and (iii) dedicated robustification closes the gap between the attention-based architecture and the most robust models, though each strategy hurts nominal performance. The benchmark's multi-domain design proves essential, as model rankings shift across datasets, and no single domain captures the full robustness picture. MuViS-C is open-source and extensible to new datasets, failure modes, measures, and models.

0.29

PIA: Agentic Physics-Informed Runtime Anomaly Detection

cs.LG cs.AI ·2026-11-07 ·Ali Mohammadi Ruzbahani, Abbas Yazdinejad, Hadis Karimipour
benchmark similarity 0.56
Abstract

Runtime anomaly detectors for cyber-physical systems are either learned as black boxes from normal data, which miss stealthy manipulations that keep every signal inside its normal range, or derived by hand from physical models, which requires expert effort for every plant. We introduce physicsinformed agents (PIA), in which a large language model agent writes the detector itself as a set of physical residuals, such as pump characteristics, tank mass balances, and controller logic, and refines every candidate against normal operating data through an evaluation workbench before deployment. The result is a compact, human-readable detector that runs in milliseconds and names the component behind each alarm. On the BATADAL water distribution attack benchmark, PIA with Claude Opus 5.5 reaches an F1 of 0.878 on the test attacks against 0.504 for the strongest of six statistical and deep baselines, keeps detecting attacks concealed by replayed and offset sensor readings, and attributes every detected test attack to the attacked component. Ablations show that testing hypotheses against data is decisive: agents that write residuals from the plant description alone lose up to 0.28 F1, whereas agents that see only anonymized signals recover most of the physical structure.

0.49

Provenance, Not Behaviour: A Serialisation Artifact in Edge-IIoTset and a Leakage-Free Benchmark for Precision-Agriculture Intrusion Detection

cs.CR cs.LG ·2026-08-16 ·Mostafa M. Galal
benchmark similarity 0.56
Abstract · 29 pages, 13 tables. Code: https://doi.org/10.5281/zenodo.21941210 Benchmark: https://doi.org/10.5281/zenodo.21941319

Edge-IIoTset is the reference benchmark for machine-learning intrusion detection in the industrial Internet of Things, and results reported on it cluster above 99%. We show that much of that performance is not intrusion detection. The preprocessing recipe distributed with the dataset instructs researchers to one-hot encode seven categorical columns. Four of them separate attack from normal traffic with an accuracy of 1.0000 on their own, through the spelling of the placeholder written for an absent protocol field: the string "0" in the normal-traffic branch of the dataset build against "0.0" in the attack branch. The label is recoverable from a serialisation artifact encoding file provenance, with no network behaviour modelled, and separates every row of both curated subsets. Under 5-fold x 3-repeat cross-validation, five of six standard classifiers attain exactly 1.0000 +/- 0.0000 accuracy and the sixth attains 0.99998. Under a corrected protocol, naive Bayes falls by 0.3005 macro-F1 and the strongest model settles at 0.9503 +/- 0.0011. Label, ordinal and frequency encoding leak identically. Because the curated subsets also lack Modbus and per-device identity, we rebuild the benchmark from the raw captures under uniform parsing, producing AgriEdge: 1,276,122 rows, five devices with full attribution, and no column separating the classes above 0.0288. A leave-one-device-out sweep locates the generalisation boundary at the perception/actuation layer, where random forest falls from 0.9988 to 0.5083 balanced accuracy. Non-IID federated partitioning costs at most 0.0037 macro-F1, but a 20-round LoRaWAN training run costs 4.6 hours of uplink.

0.22