CS Paper Radar

Semantic-Aware Deformable Feature Alignment for Thyroid Nodule Segmentation in Ultrasound

Lei Zhang, Ruhuan Zhou, Busheng Tong, Dan Lv, Bingyu Liang, Taibao Wang, Xinyu Shi, Yifan Gao, Ming Zhang, Qin Wang

eess.IV ·submitted 2026-10-25 12:17 UTC · v1
hot direction

Abstract

Accurate segmentation of thyroid nodules in ultrasound images is essential for clinical diagnosis yet remains challenging due to boundary ambiguity, speckle noise, and complex geometric variability. Existing methods often fail to reconcile global semantic understanding with precise local boundary delineation, leading to errors in irregular cases. To address this, we propose SDFA-Net, a framework built on semantic-aware deformable feature alignment that explicitly decouples the learning of robust global semantics and detailed local geometry. Our approach integrates three main components: a clustered linear context aggregation module for efficient long-range dependency modeling, an affinity-driven token modulation mechanism using dynamic prototypes to suppress background interference, and a cascaded spatially-aligned feature fusion strategy that achieves sub-pixel geometric alignment across multiple resolution stages. By filtering and aligning multi-scale features, SDFA-Net ensures robust fusion that is both semantically meaningful and geometrically accurate. We validate our method through extensive experiments on three public thyroid ultrasound datasets, TN3K, TUCC, and DDTI, where it demonstrates superior performance over state-of-the-art methods. The proposed framework offers a generalizable solution for precise medical image segmentation in boundary-ambiguous scenarios.

Closest papers

Nearest neighbours by meaning across the whole index.

ThyCLIPNet: A BiomedCLIP-Guided Lightweight Attention-Enhanced DeepLabV3+ Framework for Robust Thyroid Nodule Segmentation

cs.CV ·2026-10-03 ·Tasnim Jahan, Md Easin Arafat, Swakkhar Shatabda
code/data similarity 0.73
Abstract

Accurate thyroid ultrasound segmentation is often challenged by low contrast, speckle noise, and unclear boundaries. Although recent methods have improved segmentation accuracy, many rely on resource-intensive architectures or lack explicit integration of multiscale features with global biomedical visual guidance. In this paper, we introduce ThyCLIPNet, a lightweight semantic-guided hybrid encoder-decoder framework that integrates BiomedCLIP-derived biomedical semantic guidance into a lightweight multi-scale CNN segmentation pipeline. The encoder integrates MobileNetV2 with efficient channel attention, while atrous spatial pyramid pooling and a custom convolutional block attention module enrich bottleneck features. The decoder combines hierarchical skip connections and lightweight attention refinement with a BiomedCLIP-guided gated fusion pathway that projects vision-only global biomedical embeddings into decoder feature space and selectively integrates them through semantic-local fusion and spatial gating. To the best of our knowledge, ThyCLIPNet is among the first lightweight thyroid ultrasound segmentation frameworks to use BiomedCLIP's vision encoder alone for image-only global semantic guidance without text prompting. Experiments on TG3K, TN3K, DDTI, and PKTN achieve dice similarity coefficients of 96.22%, 87.58%, 84.73%, and 80.70%; intersection over union scores of 92.72%, 77.91%, 73.51%, and 67.64%; and 95th-percentile hausdorff distances of 3.75, 16.38, 18.23, and 10.86, respectively. ThyCLIPNet uses 8.55M parameters and 22.99G FLOPs. Overall, the results support integrating global biomedical semantic guidance with lightweight multi-scale CNN representations for robust and computationally efficient thyroid ultrasound segmentation. Source code: https://github.com/Tasnim-Jahan/ThyCLIPNet. [Abstract shortened for arXiv. See PDF for full abstract.]

0.20

CMCNet: Aligning Ultrasound Image Embeddings with Textual TI-RADS Representations for Fine-Grained Thyroid Classification

cs.CV cs.AI ·2026-08-14 ·Bingxin Yu, Xueli Wang, Jerry Zhou, Wenyan Wang, Li Wen +4 more
datasetcode/data similarity 0.71
Abstract

Ultrasound is the primary imaging modality for assessing thyroid nodules, and the ACR TI-RADS framework standardizes diagnosis through five ultrasound feature categories that are aggregated into five risk levels (TR1-TR5). Although widely adopted in clinical practice, most deep learning approaches focus on binary malignancy classification, while multi-class prediction and explicit utilization of feature-level supervision remain underexplored, largely due to limited annotated data. In this study, we introduce the STN dataset of 600 thyroid nodules with paired transverse and longitudinal ultrasound images, bounding box annotations, and complete labels for all five TI-RADS feature categories. Following the clinical decision process, we investigate how structured feature information can guide representation learning during training while requiring only images at inference. We demonstrate that text embeddings derived from standardized feature descriptions form a stable surrogate representation for TI-RADS risk levels. Based on this observation, we propose CMCNet, which aligns image embeddings to fixed textual embeddings via a Center-Margin Contrastive Loss that simultaneously promotes intra-class compactness and inter-class separation. Experimental results show that this embedding alignment strategy is more data-efficient and robust than direct multitask learning, and consistently outperforms InfoNCE, center loss, a strong multitask baseline, and a VQA-style multimodal model, particularly in imbalanced settings. The dataset is freely available at doi: 10.5281/zenodo.19125693 and the source code is available at: https://www.healthinformaticslab.org/supp/.

0.20

Thyroid Nodule Segmentation in Ultrasound Images with Conformal Uncertainty Estimation

cs.CV stat.AP ·2026-10-09 ·Francesco Teodori, Pierpaolo Brutti, Umberto Ferraro Petrillo
publishedbenchmark similarity 0.68
Abstract · Presented at the CIBB 2026 conference

Thyroid nodules affect a large proportion of the general population. Although most are benign, a non-negligible fraction is malignant. Ultrasound imaging is the primary diagnostic modality, and accurate nodule segmentation is a prerequisite for CAD systems to classify malignancy and assess metastatic risk.\\ In this work, we propose a thyroid nodule segmentation framework that integrates a DeepLabV3+, channel-attention modules and post-hoc conformal prediction, providing both accurate mask and pixel-level uncertainty estimates. We address thyroid ultrasound nodule segmentation as the first stage of a pipeline that also includes malignancy classification and metastatic risk prediction. We adopt DeepLabV3+, whose Atrous Spatial Pyramid Pooling (ASPP) captures multi-scale context, with an EfficientNet-B5 backbone for its accuracy-efficiency trade-off. Additionally, we test three channel-attention modules: Squeeze-and-Excitation, CBAM and Grouped Channel Attention (GCA), paired with two loss formulations (Dice-BCE and Boundary).\\ Since binary masks do not indicate prediction confidence, we wrap the trained model with a split conformal prediction layer that produces pixel-level uncertainty maps with statistical coverage guarantees.\\ We evaluate all configurations on the TN3K public benchmark using a fixed split and directly compare them with state-of-the-art methods. The plain backbone already improves upon previously reported results, with CBAM + Dice-BCE emerging as the best overall configuration.

0.17

FreqDINO++: A Frequency-Guided Multi-Task Routing Vision Foundation Model for Universal Ultrasound Analysis

cs.CV ·2026-09-17 ·Qing Xu, Yixuan Zhang, Yue Li, Xiangjian He, Qian Zhang +5 more
top venuecode/data similarity 0.66
Abstract · Accepted by TBME

Ultrasound image analysis plays a crucial role in cancer screening and prenatal diagnosis, yet comprehensive assessment requires jointly addressing tasks such as lesion segmentation and benign-malignant classification. While recent vision foundation models have shown remarkable universal representations, unlocking their potential for ultrasound is bottlenecked by the considerable domain gap from natural images. Existing methods typically fine-tune heavy vision encoders for isolated tasks, incurring substantial computational overhead while overlooking the underlying commonalities across heterogeneous tasks. In this work, we propose FreqDINO++, a frequency-guided multi-task routing vision foundation model for universal ultrasound analysis. We first introduce a Multi-task Routing Adapter (MR-Adapter) to support parameter-efficient integration of task-common and task-specific knowledge, a Frequency-aware Feature Enhancer (F$^2$-Enhancer) is then designed to capture the rich multi-scale frequency characteristics of ultrasound images, and a Task-aligned Collaborative Decoder (TC-Decoder) is devised to promote collaboration between dense and global prediction tasks through global-local token interaction. Extensive experiments on large-scale multi-task and external single-task ultrasound benchmarks demonstrate that FreqDINO++ consistently outperforms strong baselines and recent foundation models across 27 diverse clinical task scenarios, while also showing promising generalization to unseen data. The code is at https://github.com/MingLang-FD/FreqDINO-Plus.

0.49

O2D-MedNet: An Optimization-Aware Dual-Domain Framework for Robust Medical Image Segmentation

cs.CV ·2026-10-26 ·Shipeng Hu, Miaohui Wang, Jing Qin, Sukun Tian, Yuchun Sun
similarity 0.65
Abstract · 16 pages, 12 figures

Medical image segmentation (MIS) remains challenging due to composite degradations and multi-scale geometric variations, which jointly impair lesion-background separability, structural consistency, and optimization stability. Existing single-stream frameworks entangle heterogeneous cues within a single representation pathway, while hybrid-stream approaches often rely on generic or static fusion, limiting effective coordination across domains and failing to explicitly address optimization instability. To overcome these limitations, we propose a new optimization-aware dual-domain framework for MIS (O2D-MedNet). First, a degradation-aware dualdomain interaction (DDI) module integrates Fourier - and Wavelet-domain features to suppress degradation-sensitive responses while preserving structural and fine-detail information. Second, a cross-backbone contour-guided fusion (CGF) module enables selective interaction between CNN-based local detail modeling and visual state-space-based global structure modeling, improving boundary accuracy and representation consistency. Third, a gradient-context optimization (GCO) strategy stabilizes training by adaptively adjusting learning dynamics based on loss trends and gradient statistics, mitigating instability caused by class imbalance and heterogeneous sample difficulty. Extensive experiments on six benchmarks demonstrate consistent improvements over state-of-the-art MIS methods across multiple imaging modalities. Further analyses confirm enhanced sensitivity, structural consistency, and optimization stability, validating the effectiveness of the proposed O2D-MedNet for robust MIS under heterogeneous conditions.

0.20

Anatomy-aware Fine-grained Multimodal Fusion for Laryngopharyngeal Cancer T-Staging Prediction Using CT and Radiology Report

cs.CV ·2026-10-05 ·Xingyue Zhao, Yanzhou Su, Fang Zhang, Zhanghexuan Ji, Yirui Wang +10 more
top venue similarity 0.64
Abstract · Accepted by IEEE Transactions on Medical Imaging (IEEE TMI)

Accurate T-staging is crucial for guiding personalized treatment strategies for laryngopharyngeal cancer. However, current clinical practice relies on invasive biopsy procedures, whereas CT-based staging remains challenging due to the complex patterns of tumor invasion. Recent computer-aided approaches face two key challenges: 1) Structural relationship modeling: existing methods underrepresent anatomically structured patterns of tumor invasion, as they either process whole CT volumes without tumor-specific anatomical constraints or rely on labor-intensive tumor segmentation. 2) Fine-grained cross-modal alignment: while radiology reports contain organ-specific invasion details, current methods that apply global feature fusion struggle to accurately align individual anatomical structures with their corresponding textual descriptions. To address these issues, we propose an anatomy-aware multimodal framework that integrates organ-level CT context and radiology reports into a unified representation for laryngopharyngeal T-staging. The framework first constructs an Anatomy-Structured Organ Graph (AOG) that captures invasion patterns between primary sites and surrounding organs, then performs Organ-Anchored Cross-Modal Alignment (OCA) so that each organ node aggregates textual evidence from the radiology report, and finally refines this graph representation by injecting organ-specific invasion cues extracted from the report via Report-Enhanced Graph-Refinement (REG), yielding a multimodal organ graph that combines spatial and textual evidence. Extensive experiments demonstrate that the proposed framework achieves superior performance in T-staging of laryngopharyngeal cancer.

0.26

Multi-Resolution Feature Fusion U-Net for Magnetic Resonance Imaging Segmentation

cs.CV cs.LG ·2026-09-24 ·Eirini Cholopoulou, Dimitrios E. Diamantis, Dimitris K. Iakovidis
publishedbenchmark similarity 0.64
Abstract

The segmentation of anatomical structures in medical images and particularly in MRI scans, is essential for clinical diagnosis and monitoring disease progression. While Deep Learning (DL) architectures, such as U-Net and its extensions are very effective in medical image segmentation tasks, they often struggle with preserving fine-grained details and global contextual information. This is especially challenging for MRI data segmentation, where anatomical structures are characterized by irregular boundaries and variations in shape, contrast, and scale. To address this challenge, we propose a novel DL architecture for MRI segmentation across different anatomical structures. Specifically, the architecture introduces a module, named Multi-Resolution Feature Fusion (MRFF), that can be easily integrated into any U-Net-like architecture. The MRFF is integrated in all levels of an encode-decoder structure, along with attention mechanisms and skip connections to extract features at multiple resolutions, enabling the model to capture both fine-grained details and global contextual information. We evaluate the MRFFU-Net on two publicly available benchmark MRI datasets of different anatomical targets; one for Cerebrospinal Fluid (CSF) segmentation in spinal MR scans, and one for left atrium cardiac segmentation, from the Medical Segmentation Decathlon (MSD) challenge. Experimental results indicate that MRFFU-Net outperforms state-of-the-art models across multiple evaluation metrics, demonstrating its effectiveness in MRI segmentation.

0.45

MOSAIC: Modality-agnostic Spectral Alignment for Federated Image-level Weakly Supervised Tumor Segmentation under Client-specific Missing Modalities

eess.IV cs.CV ·2026-08-20 ·Tarun Kumar Garg, Vaanathi Sundaresan
code/data similarity 0.64
Abstract

Trustworthy multimodal fusion in clinical settings requires handling incomplete and heterogeneous modality subsets across institutions, where privacy constraints prohibit centralized data sharing. Federated learning (FL) mitigates data-sharing constraints but suffers from client-specific missing modalities, where institutions possess incomplete multimodal subsets, degrading fusion quality and segmentation performance. While FL and weak supervision have been studied separately, their joint use with image-level labels under heterogeneous missing modalities remains unaddressed. We propose \textbf{MOSAIC}, the first modality-agnostic federated framework for weakly supervised binary tumor segmentation under client-specific missing modalities. We introduce a client-specific modality-alignment module that fuses available channels into a shared latent space without prior knowledge of modality identity, a spectral prototype alignment loss that reconciles cross-client distribution shift using compact non-invertible frequency-domain statistics, and a dedicated federated refinement network that denoises the resulting CAM pseudo-labels into accurate masks, breaking the accuracy ceiling of weak supervision. Experiments on three multi-institutional brain tumor benchmarks (FeTS2022, BraTS-MEN, and BraTS-SSA) demonstrate significant improvements over all image, box, and point-supervised baselines, approaching fully supervised accuracy using only image-level labels and reaching 0.84 Dice on FeTS2022. Dynamic new client addition enables previously unseen institutions to join an already-trained federation within 0.01-0.04 Dice without retraining. Code is available at https://github.com/Tarun2201/MOSAIC.

0.24