CS Paper Radar

A Computationally Efficient Non-Interpolation Virtual Trellis Approach for Mammogram Gradient-based Patterns Analysis

Shahid Rasheed, Muhammad Rashid, Seifedine Kadry, Salman A. AlQahtani

cs.CV cs.LG ·submitted 2026-10-25 15:04 UTC · v1

Abstract

Feature analysis is a crucial step in medical image analysis, particularly in breast cancer classification. Traditional image analysis methods often struggle with optimal patterns along the diagonal axis, computational efficiency and feature buffer storage. Different classical operators require high-efficiency hardware for the complex operations, such as image convolution and gradient analysis, which are used for processing complex machine learning models for training and test operations. Here, in this research, we introduce a non-interpolation virtual trellis-based (NVHT) operator that utilizes a filter kernel over the same square image without transformation to a hexagonal trellis. This proposed method is very efficient in reducing computational and storage costs. The proposed operator is used for improved feature extraction efficiency and accuracy in disease classification. This method outperforms conventional approaches by leveraging a hexagonal pixel representation while maintaining high sensitivity in different directions with less storage.

Closest papers

Nearest neighbours by meaning across the whole index.

A Lightweight CNN Integrated Compact Convolutional Transformer for Multi-Scale Feature Learning and reducing computational complexity for breast cancer mammography image detection and classification

cs.LG cs.AIcs.CV ·2026-09-16 ·Md Taimur Ahad, Ainuddin Ahmed
similarity 0.64
Abstract

Over the years, Convolutional Neural Networks (CNNs) have demonstrated strong capability in cancer detection and classification using medical images. However, CNN-based models often struggle to capture long-range contextual dependencies. In such scenarios, integrating Compact Convolutional Transformer (CCT) architectures after the CCT layer allows CNN-extracted features to reshape into compact patch tokens using a CCT tokenizer, followed by the addition of positional embeddings to preserve spatial structure. Using 5-fold cross-validation, the model was tested on 3 sets of breast cancer mammography. With only 250,435 parameters, the model achieved 99%-100% accuracy across 3 datasets, indicating robust generalization. Explainable AI (XAI) was integrated into the model to explain the breast cancer classification process to enhance clinical trust. The results indicate that the proposed framework is suitable for computer-aided diagnosis systems, particularly in resource-constrained clinical environments. The novelty of the proposed CNN-integrated CCT overcomes the limitation of CNN's gradient degradation in the last layers by integrating convolutional tokenization with transformer-based learning. Lighter than ViT, which is effective in capturing long-range dependencies, the model has also proven efficient in breast cancer classification by capturing long-range dependencies among breast tissue regions.

0.20

Image-Based Breast Implant Detection for Mammography Dataset Curation and Near-Real-Time Deployment: Comparing Foundation Models and Task-Specific Convolutional Models

eess.IV cs.CVq-bio.TO ·2026-10-01 ·Vasisht Ishwar, Hari Trivedi, Young Seok Jeon, Beatrice Brown-Mulry, Frank Li +3 more
similarity 0.60
Abstract · 15 pages, 6 figures, 2 tables. Submitted to the Journal of Imaging Informatics in Medicine

Purpose: To evaluate the performance-feasibility tradeoffs of foundation models (FMs) and task-specific convolutional neural networks (CNNs) trained from scratch for breast implant classification in 2D mammography, with emphasis on suitability for near real-time clinical deployment. Methods: We evaluated four models: two FMs (RAD-DINO and MammoCLIP) and two CNNs trained from scratch for implant prediction (ResNet18 and our lightweight ResNetLite). Using the Emory Breast Imaging Dataset, 5,000 unilateral screening mammograms were used for training/validation and 1,000 manually reviewed unilateral images were held out for testing. For the FMs, global image embeddings from the pretrained encoder were classified using a support vector machine (SVM). The CNNs were trained end-to-end on 2D mammograms, with ResNetLite optimized via grid search over depth and width to balance accuracy and efficiency. Performance was evaluated using AUROC, sensitivity, specificity, accuracy, embedding visualization, and inference-latency. Results: All models demonstrated strong performance on held-out test data (n = 1,000). MammoCLIP achieved the highest AUROC (0.999) with the quickest training time of 493 seconds. RAD-DINO achieved the highest sensitivity (0.980; accuracy 0.989) but had the slowest inference and training times. ResNet18 and MammoCLIP achieved comparable accuracy (0.985). ResNetLite showed no statistically significant difference from ResNet18 (AUROC 0.993; accuracy 0.976) despite using only 1.4% of ResNet18's parameters, and had the fastest inference time. Conclusion: FMs and task-specific CNN models reliably detect breast implants on 2D mammography. Model selection is best guided by deployment context: MammoCLIP for GPU-equipped hospital settings requiring scalable integration, and lightweight CNNs such as ResNetLite for resource-constrained or edge deployments.

0.12

DualMiT-Net: Local-Global Transformer-Convolutional Fusion for Breast Mass Segmentation in Mammographic Regions of Interest

cs.CV cs.AIcs.LG ·2026-08-15 ·Alibek Kamiluly, Milana Muratova, Yash Patel, Fan Li
similarity 0.60
Abstract

Breast mass segmentation is an important step in computer-aided mammography, but it remains difficult because masses can have low contrast, irregular shapes, and boundaries that blend with surrounding breast tissue. To address this problem, we present DualMiT-Net, a dual-branch network that uses both a focused view of the mass and a wider view of the surrounding tissue. The local branch uses a Mix Transformer (MiT-B5) encoder to learn mass shape, texture, and boundary information, while the global branch uses an EfficientNet-B5 encoder to learn surrounding breast context. Features from the two branches are shared at the deeper encoder levels and are then progressively fused in a single decoder. A spatial gate controls how much global information is added during decoding. We also evaluated four input representations and selected a percentile-windowed mammogram combined with a Gabor texture response. The model was trained and evaluated on the mass subset of the Curated Breast Imaging Subset of the Digital Database for Screening Mammography (CBIS-DDSM) using a patient-level split. Across three training runs, DualMiT-Net with exponential moving average weights achieved a mean Dice coefficient of 0.9375 and a mean Intersection over Union of 0.8834. It also achieved better Dice and IoU scores than six standard encoder-decoder baselines trained using the same data and training settings. These results show that combining local mass information with wider breast context can provide accurate and consistent breast mass segmentation.

0.04

M-Net: Integrating Spectral Features and Physical Field Operators into Deep Learning for Medical Image Segmentation

cs.CV cs.AI ·2026-08-12 ·Jing Zhu, Ye Wang, Fumin Wang
similarity 0.59
Abstract

Purpose: Deep learning-based medical image segmentation has achieved remarkable success, yet purely data-driven approaches often fail to exploit the rich mathematical structure inherent in medical images. We investigate whether explicit mathematical inductive biases, specifically matrix spectral analysis and vector calculus operators, can enhance segmentation beyond data-driven learning alone. Methods: We propose M-Net (Math-Augmented Network), which integrates three complementary mathematical priors into U-Net: (1) continuous spectral features derived from the condition number of centered local pixel matrices, providing a differentiable measure of texture ill-conditioning; (2) physical field operators (divergence and a discrete curl-like boundary irregularity operator) computed from image gradient fields, capturing focal intensity extrema and edge non-smoothness; and (3) a Math-Attention Gate (MAG) that adaptively fuses mathematical features with CNN-extracted deep features at skip connections. Results: Experiments on three benchmarks (LiTS, KiTS, and BraTS) show that M-Net achieves Dice scores of 78.42%, 76.15%, and 83.67%, outperforming baseline U-Net by 12.37%, 3.52%, and 5.55% on liver, kidney, and brain tumor segmentation, respectively. Ablations reveal that the condition-number feature contributes a 2.14% gain over binary invertibility features, while MAG adds 1.45% over simple concatenation. Conclusion: M-Net establishes that mathematical inductive biases provide effective complementary information for medical image segmentation. The continuous condition-number feature offers superior gradient information over discrete alternatives, and MAG preserves these priors throughout the network. This work opens avenues for integrating linear algebra and vector calculus into deep architectures for medical imaging.

0.04

MagViT: Interpretable Multi-Magnification Transformers with Patient-Level Model Selection for Breast Histopathology

eess.IV cs.CVcs.LG ·2026-08-16 ·Nabil Ashab, Soumit Kumar Kundu, Saif Mahmud Parvez, Shahadat Hossain Sohag, Bidhan Biswas +1 more
published similarity 0.59
Abstract · 13 pages, 5 figures, Accepted for publication in the International Conference on Electrical, Computer and Communication Technologies (ECCT 2…

Breast cancer is one of the most common types of cancer among women around the world. Rapid detection and early treatment can hinder its progress to more complex stages and can impede its spread to other parts of the body. Histopathological image classification is the most common task in cancer detection due to its robustness in analyzing cellular data. Breast histopathology classification requires handling both multi-scale tissue morphology and clinically relevant generalization beyond the source domain. This paper presents MagViT, an interpretable multi-magnification transformer framework with scale-gated fusion and patient-level model selection. The model uses four BreakHis magnifications (40X, 100X, 200X, 400X) and extracts per-scale representations with a ViT backbone, and combines them via a learnable gate that masks missing scales. Patient-level five-fold cross-validation with a fixed seed has been run and compared with three architectural branches. The most accurate branch is then selected as the final model due to the strongest patient-level accuracy while retaining the simplest fusion pathway. On BreakHis, our architecture achieves a mean image accuracy of 0.9191, a mean patient accuracy of 0.9643, and a mean macro-F1 of 0.9042. External transfer experiments provide preliminary evidence of cross-dataset generalization under controlled adaptation settings on BUSI (image accuracy 0.8306, macro-F1 0.7480, patient accuracy 0.8291) and IDC (image accuracy 0.8577, macro-F1 0.8191, patient accuracy 0.8372). Grad-CAM visualization indicates that the model focuses on diagnostically significant and meaningful regions across magnifications. Relative to prior ViT-centered BreakHis work, this study emphasizes patient-level selection and cross-dataset robustness under a reproducible protocol.

0.25

BEACON: A Versatile Accelerator for Computational Pathology Applications

cs.AR ·2026-09-10 ·Sumanth Gudaparthi, Ananth Krishna Prasad, Lin Jia, Rajeev Balasubramonian, Srinivasan Parthasarathy
similarity 0.58
Abstract

While accelerators for AI have seen great commercial success, it is challenging to replicate that success for other specialized domains due to a number of factors. We make the case that barriers for new accelerators can be lowered by starting with a baseline AI accelerator, and adding minimal logic to support new operators demanded by new specialized domains. This leads to a versatile chip that can be manufactured at high volume and deployed for a range of popular applications. We refer to this as the AI+X approach. This paper explores its potential for the emerging domain of Computational Pathology, which involves analysis of large whole-slide tissue images with a multi-stage pipeline. The pipeline requires support for a number of different kernels and operators - early stages perform segmentation and feature extraction, followed by graph creation with k nearest neighbor (kNN) algorithms, and finally inference with an iterative graph convolutional network (GCN) that alternates between Aggregation and Combination. We show that these stages execute inefficiently on a range of baseline CPU, GPU, AI, and GCN accelerators. That inefficiency is addressed with a combination of software re-structuring and small modifications to a baseline systolic AI accelerator. Many of the above kernels can be mapped to a systolic accelerator by offering a flexible datapath between processing elements and register access mechanisms. We add support for feature aggregation, load balanced execution, Euclidean distance calculation, binning, and counter aggregation. This additional flexibility and logic grows the area of a baseline AI chiplet by 1.1x, but by avoiding the memory wall and offering high parallelism, the proposed accelerator BEACON yields over an order of magnitude higher throughput for Computational Pathology than baseline CPU and GPU platforms.

0.11

C-LiTE: A Lightweight Foundation Model for Cellular feature learning in Histopathology

cs.CV cs.AI ·2026-11-19 ·Esha Sadia Nasir, Jiaqi Lv, Gozde N. Gunesli, Shan E Ahmed Raza
similarity 0.58
Abstract

Characterising individual cells is fundamental to computational pathology, as cellular morphology informs tasks such as tumour grading, mitotic assessment and immune profiling. However, most pathology foundation models are trained on tissue patches and capture cellular features only implicitly, while existing cell-level models are either restricted to specific cell populations or rely on computationally expensive architectures with hundreds of millions of parameters. Applying ViTs directly to small cellular crops also presents an architectural challenge: upsampling increases computational cost without adding morphological information and may introduce interpolation artefacts. To address these limitations, we introduce C-LiTE, a lightweight foundation model for cellular representation learning in H&E-stained histopathology, with only 22 million parameters. C-LiTE employs a native-resolution tokenisation strategy tailored to cellular inputs, processing 64 x 64 px cell-centred crops using a 4 x 4 patch embedding to produce a 16 x 16 token grid without image upsampling. To transfer visual knowledge from large-scale pre-training, we adapt the patch embedding weights of a pre-trained ViT-5-S using a pseudoinverse-based transformation, enabling weight initialisation at the finer patch resolution. We further assemble a pre-training dataset of 60 million cell-centred crops from TCGA, balanced across 19 cancer types and 16 tissue types. To our knowledge, this represents the largest public dataset for self-supervised pre-training on H&E images at the cellular level. We evaluate C-LiTE on seven public datasets spanning mitotic figure recognition, nucleus and cell-type classification, and immune cell phenotyping. Under frozen-feature evaluation, C-LiTE achieves a mean macro-F1 of 0.670, approaching CytoFormer (0.682) with approximately 30x fewer parameters.

0.06

Lightweight Vision Transformer-Based U-Net for Brain Tumor Segmentation from MRI

cs.CV ·2026-09-24 ·Sheekar Banerjee, Md. Srabon Chowdhury, Md. Mahbub Hasan Akash, Ishtiak Al Mamoon
published similarity 0.58
Abstract · Accepted at The 2026 IEEE International Conference on Biomedical Engineering, Computer and Information Technology for Health (BECITHCON)

Accurate brain tumor segmentation from Magnetic Resonance Imaging is essential for diagnosis, treatment planning, and surgical guidance. Although Convolutional Neural Networks, particularly UNet, have achieved significant success in medical image segmentation, they often struggle to capture the long-range spatial dependencies required to model tumors with irregular shapes and complex boundaries. This paper proposes a lightweight Vision Transformer UNet that combines the hierarchical feature extraction capability of UNet with the global context modeling of Vision Transformers. The proposed architecture incorporates a compact ViT bottleneck within a U-Net encoder-decoder framework, enabling effective learning of both local and global features while maintaining computational efficiency with only 2.6 million trainable parameters. The model was evaluated on the TCGA LGG MRI Segmentation dataset, achieving a mean Intersection over Union of 0.8100 and a Dice score of 0.8446, outperforming the baseline UNet by 3.75% and 3.15%, respectively. Extensive quantitative and qualitative analyses, including confusion matrix evaluation, precision recall curves, per-image performance distribution, and tumor size dependency analysis, demonstrate the effectiveness and robustness of the proposed method for brain tumor segmentation.

0.14