CS Paper Radar

Effects of Deep Learning Architecture and Pretraining on Automated Vocal Fold Segmentation in Ex Vivo High-Speed Phonation Images

Varun Vinayak Kalaiarasan, Charles Farbos de Luzan, Khalid Malik, Ephraim Gutmark, Liran Oren

cs.CV eess.IVphysics.flu-dyn ·submitted 2026-10-27 19:05 UTC · v1

Abstract

Two-dimensional (2D) intraglottal particle image velocimetry (PIV) of ex vivo phonation experiments quantifies vocal fold medial surface dynamics and the intraglottal flow field. However, it relies on manual segmentation because residual glare, low tissue-to-flow contrast, and tracer-particle speckle obscure the vocal fold boundaries. This study assessed how deep learning architecture and ImageNet pretraining affect automated vocal fold segmentation in these high-speed images. Four established architectures from three categories were benchmarked: the convolutional neural network (CNN)-based UNet and UNet++, the hybrid CNN-transformer-based TransUNet, and the pure transformer-based Swin-UNet, the latter two trained from scratch and from ImageNet-pretrained weights. Using 16,344 expert-annotated images from 227 phonation trials of excised canine larynges, the six pipelines were trained with five seeds under a standardized protocol and compared on 50 held-out test trials using trial-level Wilcoxon signed-rank tests with Holm correction. Mean Dice similarity coefficient (DSC) spanned only 0.9734 to 0.9764, so the pipelines differed mainly in boundary fidelity. Pretraining significantly improved the boundary F1 score (BF1) and 95th percentile Hausdorff distance (HD95) of the TransUNet and Swin-UNet, about four times more for the Swin-UNet. Once pretrained, the two performed similarly, although the Swin-UNet has only about a quarter of the trainable parameters. Without pretraining, the TransUNet had a significantly higher BF1 and a lower HD95 than both CNN-based pipelines and about half their share of images with HD95 > 50 pixels. To our knowledge, this is the first study to apply deep learning to vocal fold segmentation in 2D intraglottal PIV, and it offers a reference framework for segmenting experimental flow-visualization images with noisy optical conditions or highly deformable objects.

Comment
37 pages, 8 figures, 7 tables

Closest papers

Nearest neighbours by meaning across the whole index.

Laryngeal Structure Segmentation in High-Speed Videoendoscopy Using Deep Learning

cs.CV eess.IV ·2026-09-22 ·Sardar Nafis Bin Ali, Mohsen Zayernouri, Dimitar D. Deliyski, Maryam Naghibolhosseini
similarity 0.69
Abstract · 22 pages, 9 figures

Laryngeal high-speed videoendoscopy (HSV) offers an effective means of observing the motion of different laryngeal structures along with vibratory behaviors of the vocal folds under various voicing conditions. Segmentation of laryngeal tissues enables analysis of different tissue structures and their dynamics, helping characterize the involvement of laryngeal muscles in voice production. Given the large number of HSV frames, automating this task is imperative. While deep learning-based methods have been implemented in previous studies to segment laryngeal structures, they have not been applied to HSV data during connected speech, which poses significant challenges due to excessive tissue movements and image quality limitations associated with fiberoptic image acquisition. The application of deep learning to connected speech data is critical for capturing nonstationary laryngeal behaviors and identifying anomalous patterns associated with voice disorders. The present study aims to address these gaps by training U-Net models to detect the aryepiglottic folds and arytenoid cartilages, vocal folds, epiglottis, and glottal area, using HSV data from both sustained vowel phonation and connected speech obtained from normophonic and disordered voices. Image pre-processing techniques, including noise removal and histogram equalization, were applied to improve the quality of the training HSV images and enhance network performance. Finally, to evaluate the accuracy and reliability of the networks, quantitative performance metrics were used alongside qualitative visual inspection of the test images. The high performance of the developed networks, with overall accuracies exceeding 95%, establishes their potential as reliable tools for automated laryngeal image analysis, quantitative characterization of laryngeal dynamics, and future detection of anomalous laryngeal behaviors in clinical settings.

0.27

Arti-JEPA: Adapting Video World Model to Real-Time MRI of the Vocal Tract for Speech-Production Analysis

cs.SD cs.CV ·2026-09-09 ·Hong Nguyen, Sean Foley, Christina Hagedorn, Yijing Lu, Sudarsana Reddy Kadiri +2 more
similarity 0.61
Abstract

Real-time MRI (rtMRI) captures the dynamics of the entire vocal tract during speech, but labeled data are scarce and the modality - single-slice, grayscale, low-resolution - differs substantially from the natural videos that video foundation models are trained on. We introduce Arti-JEPA, a joint embedding predictive architecture to model vocal tract rtMRI by continuing its self-supervised objective on about 62h of unlabelled vocal-tract videos, and evaluate the frozen representation on three tasks: cross-domain phoneme prediction (on typical speakers), fluent-vs-disfluent classification (a corpus containing stuttered speech), and characterizing pre/post-operative transfer (after partial glossectomy). Three key findings emerge. (1) A temporal video prior decisively outperforms per-frame image encoders, and latent prediction (V-JEPA) is at least as strong as pixel reconstruction (VideoMAE), with the edge on fine-grained phonemes. (2) Domain adaptation is \emph{task-dependent}: it roughly doubles cross-domain phoneme prediction $κ$ (to 0.352) but does not help binary stuttering classification. (3) Arti-JEPA was able to recover phoneme signal from pre/post glossectomy speech --- an in-domain probe decodes patients at least as well as a typical speaker, indicating that the residual transfer gap is cross-speaker/domain misalignment, not surgical signal loss, and post-operative decoding does not fall below performance on pre-operative speech. Together, these position a frozen, domain-adapted rtMRI encoder as a reusable measurement tool for articulatory and clinical speech science.

0.27

PADSNet: Physics-Aware Dual-Stream Network with Biomechanical Priors for Laryngeal Lesion Classification

cs.CV ·2026-11-13 ·Zhenzhen You, Weifeng Yu, Zhenghao Shi, Shuangli Du, Minghua Zhao +5 more
similarity 0.60
Abstract

Precise classification of laryngeal lesions is clinically crucial yet highly challenging, as inter-class visual differences are often subtle. While abnormalities in vocal fold vibratory dynamics provide complementary discriminative information, existing deep learning models predominantly rely on visual appearance and lack explicit mechanisms for modeling clinically meaningful vibratory dynamics. To address this, we propose PADSNet, a Physics-Aware Dual-Stream Network for laryngeal lesion classification that integrates visual representations with explicit biomechanical reasoning. Specifically, a Wavelet-Attention Enhancement Module (WAEM) is designed to bridge the spectral-semantic gap, enabling complementary learning of spatial texture and dynamic frequency representations. Meanwhile, a Knowledge Computing Module (KCM) extracts interpretable biomechanical indices from temporal glottal distance waveforms, including indicators of mobility, symmetry, glottal closure, and vibration stability. These descriptors are subsequently incorporated into a Physics-Aware Gating Module (PAGM) as biomechanical priors to adaptively recalibrate visual feature toward pathology-relevant vibratory patterns. Extensive experiments on a clinical dataset demonstrate that PADSNet achieves an accuracy of 0.8452, an F1-score of 0.8090, a sensitivity of 0.7953, and a specificity of 0.8866. These results indicate that explicitly integrating biomechanical priors with deep visual representations provides a more accurate, robust, and clinically interpretable framework for automated laryngeal lesion classification.

0.21

Reconstructing the Vocal Tract with Differentiable Acoustic Simulation

cs.SD cs.CLeess.AS ·2026-09-29 ·Eric Ming Chen, Jin Woo Lee, Vincent Sitzmann
top venue similarity 0.59
Abstract · Accepted as NeurIPS 2026 spotlight paper. Supplementary material at https://people.csail.mit.edu/echen/vocal_recon/

The vocal tract is the region of the human body responsible for filtering one's voice to create speech. In this paper, we present a differentiable and GPU accelerated acoustic simulator for the vocal tract. The differentiable simulator synthesizes speech by propagating sound along an acoustic tube model of the vocal tract, and via its gradients, can solve the inverse problem: reconstructing the shape of the vocal tract solely from the sound it produces. Although the inverse mapping between geometry and sound is notoriously non-convex, we discover that gradient descent succeeds with three technical contributions: (1) we design a frequency domain formulation of the vocal tract's fluid dynamics that is 70x more GPU parallelizable than finite differences in time, (2) we integrate a differentiable model for turbulence to synthesize consonants, and (3) similar to prior work in implicit neural representations (INRs) and neural fields, we find that parameterizing the geometry with a neural network accelerates convergence and escapes local minima that trap discrete representations. Because the simulator is differentiable, it is readily integrated with other deep learning pipelines to enable novel linguistics and medical imaging applications. (1) We demonstrate self-supervised autoencoding of vocal tract shapes across 11 languages, and (2) we couple our simulator with a generative model of MRI (magnetic resonance imaging) images to reconstruct one's moving vocal tract from only their speech without paired data.

0.50

LipLingo: CNN Model for Lip Reading

cs.LG cs.AIcs.CV ·2026-11-02 ·Mahmoud S. Mayaleh, Liban Ali Achkir, Nijat Mehdiyev, Ahmet Ozdil
similarity 0.58
Abstract

Lip reading plays a crucial role in applications such as speech recognition, assistive technologies for the hearing-impaired, and biometric authentication. However, performance often degrades when the speaker varies and when certain speech sounds are visually similar. To address these challenges, we propose LipLingo, a robust lip-reading system based on the LipNet architecture, enhanced with a standardized preprocessing pipeline for consistent mouth-region representation, a rotational validation strategy for improved generalization to unseen speakers, and a flexible similarity evaluation for more reliable sentence-level assessment. The model architecture combines 3D convolutional layers for spatio-temporal feature extraction and bidirectional recurrent layers for sequence modeling, optimized using the Adam optimizer and Connectionist Temporal Classification (CTC) loss. On the GRID dataset, LipLingo achieved 95.0\% character-level accuracy (CER 4.99\%) and 87.2\% sentence-level accuracy. At the corpus level, the system obtained a (WER 13.1\%), outperforming the baseline LipNet and demonstrating competitive performance relative to recent 3D-ResNet + Bi-GRU + MixUp approaches. These results provide insights into strategies that enhance lip-reading robustness and highlight directions for future work toward real-world deployment.

0.14

Large-Scale Pretraining for Improving Deep Learning-Based Geometric Distortion Correction of Diffusion-Weighted Imaging

cs.CV cs.LG ·2026-09-06 ·Saroj Khanal, Yashawant Kumar Yadav, Kritam Bhattarai, Jeevan Neupane, Shristi Subedi +10 more
similarity 0.57
Abstract

Diffusion-weighted imaging (DWI) is widely used in clinical settings but remains vulnerable to geometric distortion. Conventional correction methods often require additional acquisitions or vendor-specific solutions, limiting their feasibility in high-throughput, resource-constrained settings. This study investigates whether large-scale pretraining strategies can improve deep learning-based distortion correction for single-phase-encoding DWI. We formulate the task as image reconstruction, and compare a non-pretrained baseline against a self-supervised and a generative pretrained model, evaluated using both quantitative image-similarity metrics and qualitative expert assessment. The best-performing model was further tested for transferability on data collected in an LMIC setting with acquisition shift. Pretrained models outperformed the non-pretrained baseline, with cWDM achieving the strongest results across both quantitative and qualitative evaluation. However, application to LMIC data revealed transferability challenges, including contrast alteration and over-reliance on T1-weighted anatomical structure. Registering images to a common standard space improved predictions, suggesting that harmonized preprocessing may enhance cross-domain deployment.

0.22

A foundation for systematic analysis of transformers and RNNs for tractography

cs.LG eess.IVq-bio.NC ·2026-10-01 ·Emmanuelle Renauld, Philippe Poulin, Hugo Larochelle, Antoine Théberge, Maxime Descoteaux
published similarity 0.56
Abstract

Machine learning (ML) has emerged as a promising approach for improving diffusion MRI (dMRI) tractography, a task that remains limited by the intrinsic tension between local diffusion information and global anatomical plausibility. In this work, we systematically evaluate recurrent neural networks (RNNs) and Transformer models for iterative tractography, with particular attention to training strategies, input representations (including convolutional neural network (CNN)-based embeddings and end-of-sequence (EOS) tokens), and hyperparameter selection. We introduce a generation-validation phase enabling supervision at the streamline level during training, allowing supervision despite the mismatch between local loss functions and global streamline quality. Using the ISMRM2015 tractography challenge dataset, our models achieve the highest reported performance to date. Through controlled experiments, we quantify the impact of missing bundles, noisy or imperfect training streamlines, and invalid fibers in the training set. Finally, we demonstrate the applicability of our best-performing models for in vivo data from the Tractoinferno database. Overall, our results highlight both the potential and the limits of sequence-based deep learning models such as Transformers and RNNs for tractography, and emphasize the need for improved phantoms and evaluation methods for in vivo validation. We provide takeaways and recommendations for future researchers training and validating sequence-based supervised methods for tractography.

0.30

Robust Lightweight Deep Learning Models for Oral Cancer Screening

cs.AI ·2026-08-21 ·Siddhant Bharadwaj, Aakash Shedsale, Tejashree Subramanya, Mohd. Azfar, Praveen Birur +4 more
published similarity 0.56
Abstract · 10 pages, 3 figures, Paper accepted for the 6th International Conference on AI-ML Systems, 2026

Oral cancer is a leading cause of mortality in low-to-middle-income countries, where a shortage of specialists delays diagnosis. While point-of-care screening via smartphones offers a scalable solution, developing robust AI for resource-constrained settings poses significant challenges, including class imbalance in training data, variable data quality, and computational constraints on edge devices. In this paper, we present the optimisation of lightweight deep learning models for smartphone-based oral cancer screening. Using a diverse, multi-centre retrospective dataset of approximately 30,000 images acquired over a decade, we systematically evaluate state-of-the-art convolutional, transformer, and hybrid architectures. Through rigorous pipeline ablation, we demonstrate that directly optimising hybrid architectures for the edge strictly outperforms computationally heavy paradigms, such as large models or knowledge distillation. Furthermore, interpretability analysis and simulated noise-stress tests revealed that the system anchors on clinical features and remains robust to unstructured sensor noise, despite vulnerabilities to impulse bit errors. In the held-out test set, our optimised MobileViTv2 models achieved an average sensitivity of 83.2 $\pm$ 1.5% and an average specificity of 86.0 $\pm$ 0.8%, with the best model exhibiting 87.4% sensitivity, 86.5% specificity, and a critical negative predictive value of 97.2% with reference to specialist labels. These results confirm that with targeted architectural selection and streamlined optimisation, interpretable and robust lightweight AI models exhibit high potential for edge deployment to enable automated triage in primary care settings.