CS Paper Radar

Agentic AI Reasoning and Learned Sampling for Task-Aware Projection Selection in Sparse-View CT: Predicting Hemodynamics

Mahmoud Elhadidy, Roshan M. D'Souza, Amirhossein Arzani

cs.AI physics.flu-dyn ·submitted 2026-10-28 22:30 UTC · v1

Abstract

Sparse-view computed tomography (CT) reduces the number of acquired projections, but conventional sampling strategies are designed primarily for image reconstruction rather than for downstream physical inference. Here, we investigate optimal task-aware projection selection for directly predicting hemodynamics from sparse CT angiography (CTA) measurements. Using computational fluid dynamics simulations of intracranial aneurysms, we generate synthetic fan-beam CTA projections and train a Fourier neural operator (FNO) to predict two targets: the spatially resolved time-averaged wall shear stress (TAWSS) field and the spatially averaged TAWSS. The FNO was coupled with optimal input selection for simultaneous optimal sampling and training. Our goal was to investigate if agentic AI could discover optimal sampling strategies that outperform current methods. We compared fixed uniform and golden-angle sampling with three task-aware optimal selection strategies: Gumbel-Softmax, a Soft top-K method, and an agentic AI selector. The methods were compared at different view selection budgets. A detailed analysis of the AI agent was performed to understand its reasoning and performance. For spatially resolved TAWSS, Agentic and Soft top-K achieve the lowest mean errors (Agentic performs slightly better) and substantially outperform fixed sampling under extreme sparsity. For spatially averaged TAWSS, optimized selection becomes important at extremely sparse acquisitions. Analysis of the selected masks reveals multiple distinct subsets concentrated around informative regions. Moreover, masks optimized for hemodynamic prediction yield poor image reconstructions, showing that task-optimal acquisition differs fundamentally from reconstruction-optimal acquisition. This work suggests the possibility of designing sparse acquisitions directly around downstream physical quantities.

Closest papers

Nearest neighbours by meaning across the whole index.

Taming Neural Fields with a Frequency-Lipschitz Curriculum for Sparse-View CT Reconstruction

cs.CV cs.LG ·2026-11-11 ·Songtao Hu, Jingrui Wu, Hong Ding, Fanhao Zhu, Yunhao Liu +1 more
similarity 0.66
Abstract

Sparse-view computed tomography (SVCT) reduces radiation dose by acquiring fewer projection views, but the resulting under-determined inverse problem requires careful regularization to prevent reconstruction algorithms from fitting streak artifacts and hallucinated structures. Existing implicit neural representation (INR) methods rely on implicit spectral bias or iterative external denoising, yet they provide limited control over when high-frequency capacity is exposed during optimization. To address this limitation, we propose FLIC (Frequency-Lipschitz INR Curriculum), a capacity-controlled self-prior INR framework that makes the network's representational capacity explicit and schedulable. The core of our method is a joint frequency-Lipschitz curriculum that couples random Fourier feature encoding with spectrally normalized MLP decoding under non-uniform Lipschitz budgets, guiding reconstruction along a coarse-to-fine trajectory from stable global anatomy to fine details. The terminal capacity is automatically calibrated from FBP gradient statistics, enabling scan-adaptive regularization without per-scan manual tuning of the terminal Lipschitz budget. We further introduce a prior-guided adaptive ray sampling strategy that concentrates integration samples near high-gradient anatomical boundaries, improving forward-model fidelity. The entire framework operates in a single training stage without iterative denoising, enabling efficient per-image reconstruction. Extensive experiments on four public CT datasets under noise-free and low-dose settings show that our method achieves state-of-the-art unsupervised reconstruction quality with consistent performance across diverse anatomical structures.

0.13

View optimization in Computed Tomography

eess.IV ·2026-11-02 ·Seemeen Karimi, Christopher McGuire
published similarity 0.66
Abstract · All figures are in the PDF. presented at a conference, conference proceedings pending

Many emerging CT imaging applications must operate with data from sparse projection angles, on the order of 10 views, such as first responder scenarios, dynamic imaging of detonation events, and flash imaging of materials under extreme conditions in high energy-density science. Few-view imaging is a data undersampling problem, that degrades tomographic reconstructions with streaks, shadows, and other aliasing artifacts, due to ill-conditioning. In few- view CT, the specific set of projection angles can strongly impact reconstruction quality, and the optimal angles depend on the object being scanned. Despite a surge of recent research, there is much to explore in this problem. We present an object-aware performance prediction framework for few-view projection datasets based on a matrix decomposition of the discretized forward model augmented with expected object gradient information. The method yields a quantitative score for a candidate set of view angles that can underpin a view selection recommendation algorithm. A key feature is that it can be applied at multiple stages of acquisition: a priori, before any radiographs are taken, or adaptively, after some radiographs are collected, to determine the next best view. We demonstrate the approach using simulated CT data with 5 view and 15 view configurations. Preliminary results are encouraging; images reconstructed using a standard statistical algorithm show that reconstruction accuracy agrees with our performance score. Reconstruction accuracy was evaluated against a known ground truth using an information theoretic score. Continued testing with complex objects and multiple geometries is necessary.

0.14

Extremely Sparse-View Computed Tomography from 2D Projections via Pose-Aware Diffusion Priors

cs.CV cs.AI ·2026-10-28 ·Linrui Dai, Jinxiu Liang, Chu Zhou, Mae Yamaguchi, Ryuya Takahashi +1 more
published similarity 0.63
Abstract · NeurIPS 2026 poster

Extremely sparse-view computed tomography (xSV-CT) is critical when scanning time, motion, or radiation tolerance limits each scan to only a few projections. In many such scenarios, the same acquisition limits also constrain dataset construction, making pre-reconstructed 3D volumes from dense scans unavailable. This exposes a gap in current sparse-view approaches: Optimization-based methods, which use the sparse measurements directly but lack data-driven priors to suppress artifacts, and learning-based methods, which use strong priors but usually require densely scanned training volumes acquired outside the xSV-CT regime. We study this train-sparse / infer-sparse setting by learning a pose-aware diffusion prior from one 2D projection per training sample, then guiding diffusion sampling with measured-view fidelity, shared-volume reprojection, and projection-physics consistency for tomographic reconstruction. On two public CT datasets across 1-, 4-, and 8-view settings, the proposed method achieves the best novel-view synthesis scores and best or competitive reconstruction quality compared with baselines that use dense-volume supervision.

0.26

Physics-Informed Hemodynamic Modeling for Data-Free Prediction and Sparse-Data Assimilation

eess.IV cs.AI ·2026-09-16 ·Xi Chen, Jianchuan Yang, Hongde Li, Guangxin He, Qiuyu Ye +3 more
similarity 0.63
Abstract

Clinical decision-making for coronary intervention relies mainly on angiography and fractional flow reserve (FFR). However, angiography is two-dimensional and lacks depth information for 3D lesion characterization, while FFR provides only a single functional index, offering limited hemodynamic insight. Among existing methods, numerical analysis is computationally expensive, whereas learning-based approaches require extensive supervision and often lack physical consistency. To address these limitations, we propose physics-informed hemodynamic modeling, an integrated deep learning framework for 3D coronary blood flow analysis from dual-view angiography. First, an attention-enhanced CNN reconstructs coronary geometry from angiography. The resulting point clouds are then mapped to a reference domain and Fourier-encoded for joint representation. A decoupled network separately predicts velocity and pressure fields, with embedded physical priors enabling efficient transfer across physiological conditions. Across 32 clinical patients evaluated under four flow conditions, the trans-stenotic pressure-drop mean absolute percentage error was 2.02%, while the velocity and pressure relative-L2 errors were 0.054 and 0.023, respectively. Validation against hospital-measured FFR further achieved 93.8% diagnostic accuracy (30/32; exact 95% CI, 79.2%-99.2%). The framework also supports illustrative revascularization comparisons and sparse-data assimilation, with the full angiography-to-hemodynamics pipeline completed within 20 minutes per patient.

0.11

GeoPose: Patient-agnostic CTA-to-DSA registration through projection-space calibration

cs.CV ·2026-08-17 ·Rudolf L. M. van Herten, Robert Graf, Paula Feldman, Johannes C. Paetzold
similarity 0.63
Abstract

Aligning intraoperative biplanar digital subtraction angiography (DSA) to pre-procedural computed tomography angiography (CTA) requires rapid and accurate 3D-to-2D registration. Optimization-based methods are sensitive to initialization and may require hundreds of iterations, whereas learning-based approaches commonly rely on patient-specific training. We propose GeoPose, a population-trained framework that estimates the C-arm pose in a learned canonical frame and transfers it to the native frame of an unseen CTA through projection-space calibration and transform composition. A population-trained residual network refines the pose, followed optionally by low-budget image-driven optimization. GeoPose requires neither patient-specific adaptation nor explicit inter-volume preregistration. On 80 DSA observations from 20 held-out patients, optimization-free GeoPose achieved a carotid mean projected centerline distance (mPCD) of 5.8 mm and a clDice of 0.45, compared with 14.5 mm and 0.28 for the best-performing baseline, while requiring only 0.15 s. After 25 optimization iterations, GeoPose reached an mPCD of 4.6 mm and a clDice of 0.58 in approximately two seconds. Under the same budget, native-initialized optimization achieved 14.6 mm and 0.15, respectively. GeoPose thus provides rapid native-frame registration with fixed population-level weights and the geometric correspondence required for downstream biplanar 3D vascular reconstruction.

0.28

VascuSR: Iterative Anatomy-Aware Diffusion for CT Super-Resolution

cs.CV cs.AIcs.LG ·2026-10-14 ·Hairong Ni, Jiahe Huang, Minghao Guo, Wojciech Matusik, Rose Yu
similarity 0.63
Abstract

Generative super-resolution (SR) can recover sharp detail in computed tomography (CT) images from severely downsampled observations, but the missing high-frequency content is not uniquely determined by the low-resolution input. Consequently, visually plausible reconstructions may contain anatomically unsupported vascular detail, such as missing, spurious, or incorrectly connected vessels. To overcome this challenge, we introduce VascuSR, an iterative anatomy-aware diffusion framework that combines image reconstruction with explicit 3D vascular guidance. First, to provide richer anatomical guidance, we use an explicit 3D vascular representation that captures structural information beyond individual slices. This representation also simplifies vascular refinement by allowing a lightweight 3D generative refiner to focus on vascular structure rather than complex CT appearance. Second, to guide slice-wise SR, a lightweight anatomy controller injects the refined structure into the diffusion decoder, while iterative feedback updates this guidance from each new SR volume. On re-annotated MSD Task08 and HVM datasets, VascuSR outperforms interpolation and learning-based SR baselines in segmentation accuracy (Dice and clDice) and 3D vascular structure (connectivity and mean centerline distance), while maintaining image quality comparable to its SR backbone. Compared with learning-based baselines, VascuSR reduces class-averaged connected-component counts by over 20% on both datasets and mean centerline distance by over 10% on MSD.

0.23

SONAR: A Structure-Consistent Neural Operator for Null-Space-Aware Sparse View CT Reconstruction

eess.IV cs.CV ·2026-09-12 ·Song Ni, Haijun Yu, Haodong Li, Changsheng Fang, Shuyi Fan +2 more
similarity 0.62
Abstract

Sparse-view computed tomography (CT) reduces radiation dose and acquisition time but remains severely ill-posed because incomplete projections poorly constrain null-space information. Existing learning-based methods often estimate this information in high-dimensional image space, conflate physical measurement errors with prediction errors, and depend on fixed discretizations. We propose SONAR, a Structure-Consistent Neural Operator for Null-Space-Aware Reconstruction. Instead of recovering the full null-space component, SONAR predicts a low-dimensional null-space-aware representation from the acquired projections as pseudo-measurements. It separates measurement and pseudo-measurement residuals, lifts them into the image domain through physics operators, and applies independent neural operators to constrain their structural effects, thereby accommodating admissible errors while suppressing unsupported structures. To support cross-discretization reconstruction, an anisotropic U-shaped neural operator models the periodic angular and nonperiodic detector dimensions using direction-dependent continuous supports, while image-domain neural operators re-discretize continuous kernels on target grids. These components form an optimization-inspired unrolled network. Experiments on simulated AAPM and clinical MARS photon-counting CT data demonstrate consistent improvements across seen and unseen view settings and unseen image resolutions. On AAPM dataset, SONAR improves PSNR by 1.87~dB at 62 views and by 7.63~dB under zero-shot transfer to a $512\times512$ grid over the strongest competing methods. SONAR also achieves the best overall performance in all clinical settings evaluated, demonstrating accurate, structurally reliable, and discretization-robust sparse-view CT reconstruction.

0.26

TomoTransformer: Towards a Foundation Model for CT Reconstruction

cs.CV cs.LG ·2026-09-29 ·AmirEhsan Khorashadizadeh, Benjamín Béjar
benchmark similarity 0.62
Abstract

Supervised deep learning has advanced sparse-view tomographic reconstruction. However, conventional models, which typically map filtered back-projection (FBP) images or sinograms to clean reconstructions, are brittle under distribution shifts. Because they require retraining whenever projection counts and angles, detector resolutions, or data distributions change, their deployment in real-world applications remains limited. To address this, we introduce TomoTransformer, a transformer-based architecture that treats each \textit{local} filtered projection as an individual token and predicts missing views via self-attention. Crucially, TomoTransformer operates in a \emph{back-projection space} that separates projections across spatial locations, making view interpolation geometrically well-posed and invariant to detector size. This design yields a single foundation model that can process any number of input projections, at arbitrary angular locations and detector dimensions, and query any number of target angles without retraining. Trained on a large-scale dataset spanning diverse medical CT anatomies and natural images, TomoTransformer generalizes effectively across anatomies, materials, and resolutions. Extensive evaluations on several benchmark sparse-view datasets show that TomoTransformer significantly outperforms concurrent multi-purpose models like ViewTrans and matches or exceeds strong protocol-specific baselines, while remaining fully agnostic to the number of input and target projections. Furthermore, the model demonstrates robust zero-shot generalization on real experimental nanoscale brain data collected from an X-ray synchrotron, showcasing its practical utility for real-world applications.

0.19