CS Paper Radar

Morphology-Aware Channel-Decoupled Mamba Network for Medical Image Segmentation

Chenchen Wang

cs.CV ·submitted 2026-10-29 13:55 UTC · v2

Abstract

Accurate multi-organ segmentation in computed tomography (CT) is essential for computer-aided diagnosis, treatment planning, and disease monitoring. However, substantial variations in organ shape and size, together with low tissue contrast and ambiguous boundaries, complicate the modeling of heterogeneous anatomical structures. To address these challenges, we propose a Morphology-Aware Channel-Decoupled Mamba Network (MCDNet), which integrates adaptive local structural enhancement with channel-decoupled long-range modeling. Specifically, we introduce a Morphology-Aware Channel-Decoupled State-Space (MCSS) block that divides feature channels into separate processing groups, allowing differentiated structural representations to be learned within an efficient state-space framework. Within each group, a Morphology-Aware Enhancement Module (MAEM) combines deformable convolutions with channel attention to adapt local feature extraction to anatomical shape variations. Group-wise state-space modeling then captures long-range spatial dependencies, and channel gating adaptively integrates the resulting features. Experiments on the Synapse abdominal CT dataset demonstrate the effectiveness of MCDNet, achieving an average Dice Similarity Coefficient of 81.61% for multi-organ segmentation.

Closest papers

Nearest neighbours by meaning across the whole index.

TRIUNE-Net: Harmonizing Scale, Shape, and Efficiency in Pancreatic Tumor Segmentation

cs.CV ·2026-09-08 ·Amir Hossein Saleknia, Alireza Kheyrkhah, Sanaz Karimijafarbigloo, Reza Azad, Sina Houshmand +3 more
code/data similarity 0.68
Abstract

Pancreatic tumor segmentation in 3D CT volumes is challenged by extreme scale variability across both the pancreas and tumor, and highly irregular tumor morphology. While recent advances have pushed segmentation performance, existing methods do not explicitly address these challenges and come at the cost of excessive computational complexity, limiting their practicality in resource-constrained clinical environments. We propose TRIUNE-Net, a lightweight unified architecture that harmonizes scale, shape, and efficiency through three synergistic innovations. A multi-scale context aggregation module with stage-adaptive dilated convolutions enables the model to reason across the broad range of anatomical scales present in both organs. A serial linear-deformable attention mechanism combines large effective receptive fields with shapeadaptive deformable convolutions to capture irregular, non-convex tumor morphologies. Finally, an information-preserving downsampling module replaces conventional max pooling entirely, retaining all spatial information while adding negligible parameters, preventing small tumors from being discarded before they can be recognized. On both the MSD Pancreas and NVD Pancreas datasets, TRIUNE-Net achieves state-of-theart results with only 5.86 M parameters and no external pre-training, outperforming all baselines across all key tumor metrics. Specifically, it surpasses the next-best model by 0.45% in tumor Dice, 6.0 points in F1 score, 6.6 points in sensitivity, and 3.4 points in precision, simultaneously reflecting its ability to suppress both missed tumors and false alarms in clinically realistic conditions. Our code is available at: https://github.com/abdora-ai/TRIUNE-Net

0.30

Prompt-Conditioned Channel Attention for Hierarchical Feature Modulation toward Anatomy-Agnostic Segmentation

cs.CV cs.AI ·2026-08-20 ·Mosharof Hossain, Md Rabiul Islam, Limon Halder, Erchin Serpedin, Md Kamrul Hasan
similarity 0.68
Abstract

Anatomically plausible segmentation remains challenging because of low contrast, ambiguous boundaries, and modality-specific artifacts. Interactive segmentation has emerged as a promising strategy to guide feature extraction and improve localization, particularly in structurally ambiguous regions. However, existing methods integrate prompts through late-stage fusion and lack explicit mechanisms for prompt-driven channel-wise modulation across hierarchical feature representations, limiting their ability to capture deeper contextual and modality-specific variations. To address these limitations, we introduce Prompt-Conditioned Channel Attention (PCCA), a novel modulation mechanism that enables deep, hierarchical integration of semantic prompts within encoder-decoder networks. PCCA extracts compact channel descriptors via pooling, projects them into a shared space, and fuses them through a gated excitation mechanism to compute prompt-aware channel attention weights. These weights adaptively recalibrate feature responses across multiple network stages, enabling prompt-conditioned, semantically enriched hierarchical representations. Building on this, we propose PROMISE-Net, instantiated in two network variants: a convolutional model (PROMISE-CNN) and a transformer-based model (PROMISE-Txformer). Across the ISIC-Lesion, Kvasir-Polyp, CAMUS-Cardiac, and Kvasir-Instrument benchmarks, integrating PCCA into PROMISE-CNN yielded relative IoU gains of 10.4%, 8.7%, 0.8%, and 3.4%, respectively, over the baseline U-Net, while PROMISE-Txformer achieved corresponding gains of 7.6%, 23.0%, 2.1%, and 1.1%, respectively, over the baseline UNETR. These results show consistent improvements across architectures, imaging modalities, and anatomical targets, establishing PCCA and PROMISE-Net as a scalable, generalizable framework for prompt-aware hierarchical feature modulation in medical image segmentation.

0.17

B-MIM: Biased Masked Image Modeling for Generalizable Segmentation of Fine-Grained Anatomical Structures

cs.CV ·2026-08-25 ·Sebastián González, Karen Sanchez, José M. Saavedra, Marcelo Pizarro, Bernard Ghanem
published similarity 0.67
Abstract · Published at MedAGI in MICCAI 2026

Self-supervised pretraining enables transferable representations for medical imaging, yet most CT encoders remain biased toward coarse semantic understanding, limiting their sensitivity to fine-grained anatomical structures such as vessels or small tumors. In this paper, we introduce Biased Masked Image Modeling (B-MIM), a modification of the iBOT objective that stochastically reduces global semantic alignment to prioritize local patch reconstruction. This bias encourages the encoder to capture high-frequency morphological details and structural continuity. We curate a multi-institutional CT abdominal dataset of 9,955 filtered studies from 17 public sources and pretrain a 3D Swin Transformer backbone using B-MIM. Across inter-dataset experiments on liver vessel segmentation, the proposed encoder improves topological fidelity (clDice) and achieves competitive Dice scores in tumor segmentation, compared to fully fine-tuned baselines, despite updating only a fraction of the parameters. Our results suggest that reducing global semantic pressure during pretraining enhances generalization to intricate anatomical structures.

0.25

Segment Anything Model Based Context Guided Mamba Unet for Medical Image Segmentation

cs.CV ·2026-10-29 ·Chenchen Wang
similarity 0.64
Abstract

Medical image segmentation is crucial for clinical diagnosis and treatment planning, requiring both global contextual understanding and fine-grained structural precision. While the Segment Anything Model (SAM) demonstrates strong generalization capabilities, its direct application to medical images often lacks domain-specific adaptability. Meanwhile, State Space Models (SSMs)-based methods, such as Mamba, efficiently capture long-range dependencies but may struggle with preserving fine anatomical details. To address these challenges, we propose a segment anything model based context guided mamba unet, SAMBA-UNet, a novel framework that integrates SAM's context knowledge with Mamba's hierarchical feature learning to enhance both global representation and local detail refinement. Specifically, we introduce the Hierarchical Context Enhancement Module (HCEM), an attention-based fusion module that deeply incorporates the multi-level features of SAM and Mamba to improve detail perception and segmentation precision. Additionally, we employ LoRA and Adapter-based fine-tuning to adapt SAM to medical imaging tasks, further enhancing its domain-specific segmentation capability and robustness. We conducted a comprehensive study on several medical segmentation datasets, including Synapse, ISIC17, and ISIC18, evaluating our method across multiple metrics. Experimental results demonstrate that SAMBA-UNet achieves state-of-the-art performance, effectively balancing generalization, segmentation accuracy, and computational efficiency. Our code will be released upon acceptance.

0.20

SCDM: Spatial-Contextual Disentanglement Mamba via Differential Inference for Efficient Image Classification

cs.CV ·2026-09-11 ·Mustafa Bora Çelik, Hayriye Aktaş Dinçer, Ayse Keles
similarity 0.64
Abstract · 9 pages, 5 figures

State Space Models (SSMs), particularly VMamba, have emerged as efficient alternatives for modeling long-range dependencies in medical image analysis. However, distinguishing subtle pathological features from visually similar anatomical backgrounds remains a significant challenge. Existing SSM architectures often learn entangled representations, lacking explicit mechanisms to separate disease-specific signals from normal anatomy. To address this limitation, we propose Spatial-Contextual Differential Mamba (SCDM), an asymmetric dual-branch architecture designed for selective representational disentanglement. SCDM introduces a Positive Branch for extracting discriminative features and a Negative Branch that actively models and suppresses normal anatomical context. This separation is achieved through a similarity-driven repulsion gate and a differential inference rule, which promote competitive feature learning without requiring additional branch labels or increasing model capacity. Evaluated on the RSNA Pneumonia dataset, SCDM achieves competitive classification performance (AUC of 0.858) while requiring significantly fewer parameters (29.4M) and FLOPs (1.44G) compared to standard VMamba and vision transformer baselines. Furthermore, activation analyses demonstrate that our differential mechanism yields highly precise localization, effectively isolating lesions by inhibiting irrelevant anatomical distractors.

0.21

Anatomical Prior-Guided Routing for 3D Lung Tumor Segmentation

cs.CV ·2026-10-29 ·Uihyeon Maeng, Jonghun Kim, Hyunjin Park
published similarity 0.64
Abstract · Accepted to ACCV 2026 (Oral), 18 pages, 6 figures

Accurate lung tumor segmentation in computed tomography (CT) is essential for treatment planning, response assessment, and quantitative imaging analysis. However, 3D lung tumor segmentation remains challenging because tumors occupy only a small portion of the whole volume and exhibit heterogeneous appearances across anatomical locations. In patch-based training and sliding-window inference for 3D medical image segmentation, location-dependent heterogeneity is further amplified because cropped image patches provide limited global anatomical context, making it difficult for a model to adapt its feature processing according to the anatomical region from which each patch is extracted. To address this limitation, we propose an Anatomical Prior-guided Routing Module (APRM) for lung tumor segmentation. For each image patch, we obtain anatomical prior information of regional occupancy and deterministically select an anatomical routing gate. The selected gate then performs sparse feature routing over a shared expert adapter pool, enabling anatomy-specific feature adaptation while sharing expert capacity across regions. We evaluate APRM on two datasets with various backbone networks and demonstrate consistent improvements over baseline models. Furthermore, feature visualizations show that APRM produces different feature responses depending on patch location, indicating that the proposed routing mechanism effectively adapts feature processing according to anatomical context.

0.26

Weakly-supervised Kidney Tumor Classification from CT Scans with Multi-Instance Learning and Anatomical Filtering

cs.CV ·2026-09-07 ·Joonas Ariva, Dmytro Fishman
similarity 0.64
Abstract · 16 pages, 3 figures

Deep learning models for CT scan analysis are often limited by the scarcity of precise pixel-level annotations, which require significant radiologist effort to produce. Training on scan-level labels alone reduces annotation requirements but introduces challenges: low supervision ratios and large input volumes make models prone to overfitting and shortcut learning. In this work, we investigate two complementary methods to address these challenges: multi-instance learning (MIL) and anatomical filtering. MIL divides CT volumes into 2D slice instances, enabling efficient 2D architectures with ImageNet pretraining rather than computationally demanding 3D models. Anatomical filtering uses Compass, our self-supervised body part regression model, to crop scans to pathology-relevant subregions without requiring segmentation masks. We evaluate two MIL frameworks - Attention-based MIL (ABMIL) and FocusMIL - on kidney tumor classification across one internal dataset (TUH) and two external datasets (KiTS23 and TCGA-KiRC). Our best models achieve F1 = 0.83 on the internal test set using only scan-level labels. We further show that anatomical filtering with the Compass model is critical for the out-of-distribution generalization of embedding-based ABMIL, while instance-based FocusMIL demonstrates greater inherent robustness to distribution shift. While evaluated on kidney tumors, we consider this a proof-of-concept for a broader weakly supervised CT classification pipeline applicable to other organs and pathologies.

0.16

MAGEFormer: Learning Metric-Consistent Representations for Anisotropic CT Segmentation

cs.CV cs.AI ·2026-10-02 ·Jiaying Li, Paolo Remagnino
top venue similarity 0.63
Abstract

Vision Transformers (ViTs) have shown strong performance in volumetric segmentation, but their effectiveness on clinical CT is limited by an isotropic Euclidean lattice assumption. This conflicts with anisotropic CT acquisition, leading to two key issues: (1) a metric mismatch between voxel indices and physical anatomy, and (2) accuracy degradation from isotropic resampling. To address this, we propose MAGEFormer, a geometry-calibrated framework that embeds physical metric constraints directly into representation learning. Our method introduces Metric-Adaptive Spatial Embedding (MASE) to calibrate positional frequencies using voxel spacing, Geometry-Constrained Attention (GCA) to suppress physically implausible feature correlations, and Geometric View Voting (GVV) to reduce discretization bias during inference. We evaluate MAGEFormer on two multi-organ abdominal CT benchmarks, BTCV and FLARE 22, under a unified protocol against strong CNN and Transformer-based baselines. MAGEFormer achieves the strongest boundary accuracy among the compared methods, with 10.58 mm HD95 on BTCV and 3.40 mm HD95 on FLARE 22, and shows consistent gains in Dice under the same protocol. These results show that geometry-aware internal calibration is more effective than relying on conventional isotropic preprocessing alone for anisotropic CT segmentation.

0.32