CS Paper Radar

LAPIS: Clinically Constrained Patient-Identity Residual Learning for Chest X-Ray Anonymization

Nishi Kanta Paul, Md Shihabul Islam Shovo, Désiré Sidibé

eess.IV ·submitted 2026-10-29 05:01 UTC · v1

Abstract

Biometric information in chest radiographs limits their release for research, as patients can be re-identified. We propose LAPIS, which jointly adapts a spatial chest-radiograph latent space so that patient-discriminative information concentrates in a compact, replaceable channel residual while most clinically relevant content stays in the complement. The residual is defined by an exactly semi-orthogonal basis, a spatial adversary suppresses identity leakage from the complement, and replacement-aware training teaches the decoder cross-patient residual swaps under output identity, clinical and realism constraints, so that replacing the residual yields a valid image. At release, the residual is replaced by a mixture of donor residuals. On patient-disjoint model, release and test sets from ChestX-ray14, we evaluate attackers adapted to the anonymized setting, a structural source-retrieval attack, and pathology classifiers trained on released images and tested on real ones. LAPIS reduces worst-case cross-study linkability from 0.961 to 0.791 AUC at a macro AUROC cost of 0.012 relative to reconstruction; a deformation-based baseline, however, remains better at structural source retrieval.

Comment
5 pages, 3 figures, 2 tables. Submitted to IEEE ISBI 2027

Closest papers

Nearest neighbours by meaning across the whole index.

Federated LoRA Adaptation of BiomedCLIP Across Four International Chest X-Ray Cohorts

cs.LG cs.AIcs.CV ·2026-09-02 ·Sanjaya Poudel, Nirajan Kunwor, Manish Dhakal, Debesh Jha, Sunil Kumar Gaire
benchmark similarity 0.69
Abstract

Federated learning (FL) lets institutions train a shared model without exchanging data, and Low-Rank Adaptation (LoRA) makes this practical at scale by communicating only compact low-rank updates. Biomedical imaging is a compelling setting for this combination: patient data are archived behind privacy regulations, and institutions differ widely in scanners, protocols, and compute. Such heterogeneity raises the question of how federated LoRA updates should be aggregated, increasingly pressing as multimodal vision-language models become central to medical image analysis. We benchmark federated Parameter-efficient fine-tuning (PEFT) of BiomedCLIP for chest radiograph classification across four public cohorts on three continents (USA, Vietnam, Spain). Federated LoRA adaptation improves shared-class AUC on all four cohorts over the unadapted BiomedCLIP backbone (mean 0.687 to 0.802), showing that the gains come from federated adaptation rather than from the pretrained model's zero-shot ability. Relative to isolated single-cohort training, federation improves the weaker cohorts while largely preserving the strongest and approaches a centralized reference (0.812) that pools all data. The singular value decomposition (SVD)-based product-space aggregation introduced by FlexLoRA is essential to this gain (naive factor averaging drops mean AUC by 0.097), whereas a drift-correcting optimizer (FedProx) shows no benefit over FedAvg in our single-seed runs, consistent with LoRA's low-rank updates already limiting client drift. Biomedical vision-language models can thus be adapted collaboratively across heterogeneous, geographically distributed institutions without centralizing data.

0.11

Anatomy-Decomposed Chest Computed Tomography (CT) Projections as Scalable Supervision for Bone Suppression in Chest Radiographs

cs.CV ·2026-09-21 ·Mrunmay Angaitkar, Piyush Kumar, Aarjav Satia, Pranav Rao, Ashish Mittal +2 more
code/data similarity 0.65
Abstract

Bone overlap can obscure abnormalities in chest radiographs, while scarce paired training data limit supervised bone suppression. We address this challenge with a digitally reconstructed radiograph (DRR) framework that converts chest computed tomography (CT) into paired supervision for component suppression. A novel bone segmentation algorithm enables CT decomposition into bone, non-lung soft-tissue, and lung components, which are projected separately. Their weighted combination yields synthetic radiographs with pixel-registered component images that sum exactly to the full DRR. Models trained on these data suppress bone or lung components by predicting the target component and recovering the remainder by subtraction, transferring to real radiographs without real paired training data. As an extension, their outputs on real radiographs provide target domains for unpaired, component-wise DRR translation, reducing the appearance gap while retaining anatomical details. Across multiple public datasets, downstream detection experiments demonstrate the utility of bone suppression, with gains concentrated on abnormalities with substantial bone overlap. Compared with open-source DRR engines applied to the same CTs, our unmodified DRRs achieve comparable realism and preservation of label-relevant anatomy, while translated DRRs achieve the best Fréchet inception distance (FID), lung-field sharpness, and agreement with source-CT anatomy among the evaluated methods. Models and inference code: https://huggingface.co/qureaiorg/bone-suppression ; Translated projections: https://huggingface.co/datasets/qureaiorg/ct2xr-projections.

0.35

Cracks in Embeddings: Robustness and Stability of JEPA-Based Chest X-Ray Representations

cs.CV ·2026-11-13 ·Zahid Mansur, Kalpana Yadav, Deepak Mishra
similarity 0.65
Abstract

Self-supervised Joint Embedding Predictive Architecture (JEPA) models are increasingly used for medical imaging, however there is a limited understanding about robustness of these models toward real-world image changes. We test four JEPA-based chest X-ray encoders, trained on 78,468 NIH ChestX-ray14 images, under six tests: two black-box adversarial attacks (SPSA, Boundary Attack), three image corruptions (Gaussian noise, brightness shift, contrast shift), and a label-scarcity test, measuring embedding change and classification AUROC. These perturbations cause severe, model-dependent damage: encoder-level Cosine Similarity drops as low as 0.33, and AUROC falls by as much as 0.12 in the worst case (I-JEPA under the Boundary Test). We test two ways of training the small predictor on top of each frozen encoder to address this. Adversarial fine-tuning, trained on clean and perturbed images together, raises embedding consistency above 0.97 in nearly every case and improves AUROC, relative to the same perturbed baseline, for most models, with the largest gain of $+0.10$ on I-JEPA. A Vector-Quantized codebook method, trained only on clean images and evaluated on perturbed test images for the first time, instead degrades under distortion for all four models, most noticeably for I-JEPA ($-0.15$ AUROC on average), showing that its discrete bottleneck alone does not provide the robustness that comes from training on perturbed data directly.

0.25

Scores That Hold, Benchmarks That Leak: Measuring Dataset Contamination in Public Brain-Tumor MRI Classification

cs.CV cs.AI ·2026-09-30 ·Bhanu Prakash Vangala, Sowmya Guda, Latha Peddi, Navya Vangala
benchmark similarity 0.65
Abstract

Automated classification of brain tumors from MRI is a heavily published application of deep learning in medical imaging, with reported accuracies on public benchmarks routinely exceeding 98%. However, accuracy does not capture a critical dimension of benchmark quality: dataset integrity, defined as the independence of test from training data at the image, patient, and acquisition-source levels. We introduce a three-layer contamination framework comprising duplicate, patient, and source-label leakage to assess the public corpora on which this literature rests. We audit the three most widely used corpora against a chest-radiograph negative control and quantify each layer's effect on measured performance across nine architectures and three evaluation conditions. Contamination is severe at every layer: 28.8% of the dominant corpus's official test split has a near-twin in its own training split, a second corpus leaks 22.3% of its test images byte-identically, 95.5% of traceable test images share a patient with training, and file-header features containing no anatomy separate tumor from no-tumor at 0.959 balanced accuracy, at parity with fine-tuned ResNet backbones. The unexpected result is that removing every identified leaked test image leaves balanced accuracy essentially unchanged: stable performance after deduplication does not establish benchmark integrity. Our findings establish dataset integrity as a distinct, measurable axis of benchmark quality that a stable leaderboard cannot certify. For biomedical research, reported accuracy on these corpora alone does not establish that a model has learned to recognize tumors rather than exploit dataset-specific cues. We release the contaminated-file lists, recovered patient identifiers, and deduplicated splits.

0.44

What Do Medical Vision-Language Models Learn in Radiology? Transfer, Alignment, and Source-Proxy Leakage Under Distribution Shift

cs.CV cs.AI ·2026-08-26 ·Ayoub Louaye Bouaziz, Lokmane Chebouba, Yassine Himeur
similarity 0.63
Abstract

Medical vision-language models (VLMs) can appear reliable in-domain while failing when acquisition domain, paired supervision, or evaluation protocol changes. We study this failure mode as a representation-level blind spot relevant to epistemic intelligence, without claiming a formal estimator of epistemic uncertainty. Using NIH ChestXray14 and CheXpert, we first isolate source-only cross-dataset visual transfer from unsupervised domain-adaptation diagnostics. Using PadChest and OpenI, we then evaluate multimodal alignment under strict pair-index retrieval and quantify metadata-derived source-proxy information retained in frozen embeddings. Self-supervised visual initialization improves NIH-to-CheXpert transfer over supervised ImageNet initialization in matched ResNet-18 comparisons, whereas adversarial adaptation is useful only in a narrow regime and becomes unstable as adversarial pressure increases. Multimodal exact-pair retrieval remains low under external OpenI stress testing, and source-proxy information remains recoverable from learned representations. Qualitative nearest-neighbor and Grad-CAM analyses show clinically plausible cross-dataset structure and thoracic attention patterns in many cases, while device-heavy and false-positive cases remain ambiguous. Auxiliary architecture checks are task-dependent and do not support a universal backbone ranking. Overall, the study shows that apparent competence under a single protocol can conceal transfer, alignment, and shortcut-related failure modes, motivating stress-tested evaluation of medical VLMs under distribution shift.

0.21

Generating Chest X-Ray Counterfactuals by Specialising Foundation Image Models

cs.CV ·2026-09-21 ·Xiaodan Xing, Rajat R. Rasal, Julia A. Meister, Sara Ghorayeb, Galvin Khara +1 more
code/data similarity 0.62
Abstract · 32 pages, 6 figures, 16 tables. Code: https://github.com/GSK-AI/RadCF/

Counterfactual image generation answers questions about how a subject would have looked under retrospective, hypothetical scenarios. Recent methods have improved perceptual quality, identity preservation and faithfulness to an underlying causal model, but their adoption in healthcare is limited by scarce annotated data, distribution shift between datasets, and mismatches between pretrained generative models and those required for counterfactual inference. We propose specialisation, a data and parameter-efficient framework for adapting pretrained, non-causal generative models into causal mechanisms under distribution shift. Based on this framework, we train a radiology counterfactual image generation model, called RadCF, using latent flow matching. We validate our approach on three chest X-ray datasets spanning different dataset shifts, data volumes, and counterfactual questions, associated with challenging, highly-localised interventions. Our results show that RadCF and specialisation improve counterfactual soundness over existing methods while being data and parameter efficient, and that the resulting counterfactuals can detect and mitigate shortcut learning in a downstream medical classifier. Code is available at https://github.com/GSK-AI/RadCF/.

0.59

From Augmentation to Synthetic Evidence: Evaluating Generated Chest Radiographs at Dataset Intake

cs.CV cs.AIcs.LG ·2026-10-21 ·Shaikh Akib Shahriyar, Zinedine Sehili, Adam Arthur, Christopher Schwartz
position similarity 0.62
Abstract

While generated chest radiographs can serve as valuable data augmentation when explicitly declared, the same pixels become unsupported evidence when submitted as records of real clinical examinations. We study this dataset-intake vulnerability by disentangling three questions: (1) whether an image passes an automated technical quality check, (2) whether an origin classifier flags it as synthetic, and (3) whether a trusted provenance record supports the claimed clinical acquisition. In this study, a submitter uses Qwen3.8-27B to select up to 20 candidate radiographs from pools of 1,000 Cheff-identified or SynthCheX images, while a receiver evaluates image quality via MedGemma 1.5 and predicts origin using a linear probe over frozen DINOv3 features. Although quality selection increases MedGemma quality passes from 12/20 to 19/20 for Cheff-identified images and from 8/20 to 17/20 for SynthCheX, we find no evidence that candidate selection increases passage through both checks simultaneously: zero selected Cheff-identified images pass both gates, and uniform, quality-guided, and surrogate-guided selection yield 2, 1, and 2 SynthCheX passes out of 20, respectively. On unprocessed test cohorts, the origin classifier rejects 4,677 of 5,000 SynthCheX images at a nominal 5% false-alarm rate (flagging 110 of 2,297 real NIH radiographs), yet leaves 152 SynthCheX images that pass both pixel-level checks. Moreover, pixel-level screening is fragile to routine distribution shifts: JPEG compression reduces SynthCheX-versus-NIH AUROC from 0.987 to 0.841, and applying the NIH-calibrated threshold to an external genuine cohort (Open-I) triggers false alarms on 568 of 957 authentic radiographs (59.4%). Because pixel-level checks can filter submissions but cannot verify clinical acquisition claims, we argue that dataset intake pipelines must record and verify source provenance independently of image pixels.

0.13

Leakage- and Label-Aware Benchmarking of Class-Imbalance Strategies for Multimodal Chest X-Ray and EHR Classification

cs.LG cs.CV ·2026-11-05 ·Dang-Khoa Bui, Quang-Huy Tran, Minh-Khoi Nguyen-Bui, Duc-Tuan Ngo, Thanh-Trong Tran +2 more
benchmark similarity 0.61
Abstract · 10 pages, 1 figure, 6 tables

Benchmarks of class-imbalance strategies for multimodal chest X-ray (CXR) and electronic health record (EHR) prediction are often evaluated on record-level splits of cohorts in which one patient contributes several radiographs. We audit such a benchmark on 29,083 MIMIC-CXR radiographs of 10,479 patients with eight diagnosis targets. First, the record-split benchmark was misleading: a lookup table that copies the label of a development-set radiograph with the same EHR vector nearly matched the best model, and on unseen patients every model fell to the level of predicting every case positive. Second, tracing the labels back to MIMIC-IV explained why: each patient's labels are keyword matches on the diagnosis codes of a single admission, copied, with one EHR vector per patient, to all of the patient's radiographs, so about a third of the radiographs carry labels that differ from the codes of their own admission. Third, under patient-separated evaluation with admission-aligned and rule-refined labels, the initial conclusions do not hold: in the evaluated configurations no imbalance strategy raised the observed mean macro F2 over no augmentation by more than 0.01, tuned tree ensembles showed no consistent advantage over tuned logistic regression, and the released EHR variables stayed at the level of the all-positive baseline, whereas the diagnostic history available at imaging time and image embeddings exceeded it, including, with rule-refined labels, a CheXpert-trained encoder that never saw these radiographs; RAD-DINO had seen 96.6% of them during self-supervised pretraining. Adding either encoder to the diagnostic history gave no statistically significant F2 gain; exploratory AUROC gains were significant with RAD-DINO but not with DenseNet. We provide reusable diagnostics, a leakage-aware protocol and a checklist.

0.24