CS Paper Radar

OpenULF: A Modular Toolkit Enables Data-Driven Ultra-Low-Field MRI with both Classical and Quantum Sensors

Hanhan Wu, Yuchen Yuan, Weiwen Jiang

eess.IV cs.CVphysics.med-ph ·submitted 2026-11-01 03:43 UTC · v1
publishedcode/data

Abstract

Ultra-low-field (ULF) Magnetic Resonance Imaging (MRI) offers a portable, low-cost alternative to conventional scanners by operating at field strengths below 10 mT. At these fields, two sensor technologies compete: quantum SQUID (Superconducting Quantum Interference Device) sensors, which provide high sensitivity but require cryogenic cooling, and classical induction coils, which are inexpensive and room-temperature but produce weaker signals. With conventional physics-based imaging, both suffer from low signal-to-noise ratios (SNR). Data-driven reconstruction has overcome similar limits in related inverse problems, but its use for ULF-MRI has been hindered by a lack of open datasets, benchmarks, and flexible simulators. To close this gap, we present OpenULF, a modular, open-source simulation toolkit that generates paired training data and supports end-to-end machine-learning (ML) reconstruction. OpenULF integrates a Bloch-equation-validated physics simulator, calibrated SQUID and coil receiver models, reconstruction ML networks, and an automated design-space exploration engine. Architecturally, a receiver abstract base class, a typed HDF5 contract that decouples physics from learning, and a resumable sweep engine make sensors, models, and datasets independently substitutable. Using OpenULF, we train 774 models across four anatomical datasets and conduct three design-space explorations. The effectiveness of ML reconstruction depends strongly on the dataset and the sensor. We identify a SQUID-to-coil crossover near 450 $μ$T and demonstrate that sensor hardware and ML model capacity can be traded off during system design. Sensor and reconstruction choices must therefore be co-designed: the best sensor is set by the dataset and field strength, not by SNR.

Comment
8 pages, 6 figures, 3 tables. Accepted for publication in the 44th IEEE International Conference on Computer Design (ICCD 2026). Code available at https://github.com/Wu-Hanhan/OpenULF

Closest papers

Nearest neighbours by meaning across the whole index.

Physics-based simulation unlocks scaling laws for generalizable MRI reconstruction

eess.IV cs.CV ·2026-11-11 ·Hong Shang, Zijian Zhan, Sen Jia, Xiang Fan, Jintao Meng +8 more
similarity 0.63
Abstract

Deep-learning-based magnetic resonance imaging (MRI) reconstruction holds great promise for accelerating acquisitions, yet its clinical translation remains bottlenecked by poor generalizability across unseen scanners, populations, anatomies, and protocols. Gathering sufficiently diverse clinical datasets to overcome this bottleneck is hindered by high acquisition costs, privacy restrictions, and institutional biases. Here, we introduce Scalable Inverse Model (SIM), a framework that systematically co-designs physics-simulated training data, model architecture, and learning paradigms around scalability--leveraging compute scaling to overcome historical data bottlenecks and achieve robust zero-shot MRI reconstruction. Across 14 public and in-house datasets--spanning seven international centers, five vendors, field strengths of 0.3-7 T, over ten anatomical regions, more than ten acquisition protocols, downstream quantitative and molecular tasks, and a 150-scan blinded radiologist study--SIM demonstrates robust zero-shot generalizability, recovering fine anatomical details while suppressing aliasing artifacts where conventional deep-learning methods fail. Attention-map analyses confirm that SIM learns physically explainable, dynamically adaptive reconstruction primitives rather than anatomy-specific priors. SIM establishes a scalable, privacy-preserving, and democratized infrastructure for universal MRI reconstruction, providing a blueprint for generalizable AI across inverse problems in medical imaging.

0.22

QML for Quantum Sensing under Measurement-Induced Information Loss

cs.AI quant-ph ·2026-08-25 ·Sounak Bhowmik, Himanshu Thapliyal
theory similarity 0.60
Abstract

Nitrogen-vacancy (NV) centers in diamond can serve as highly sensitive solid-state quantum sensors for high-sensitivity magnetometry. However, in the noisy intermediate-scale quantum (NISQ) era, extracting reliable information from noisy, finite-shot, and measurement-limited sensing data remains a considerable challenge. Whereas, quantum machine learning (QML) offers a potential path to improve parameter estimation by learning nonlinear relationships between quantum-sensing data and the underlying physical signal. In this work, we investigate the role of QML in magnetic-field estimation within an NV center-inspired magnetometry setting. We formulated magnetic field sensing as a supervised regression task. We compared the performance of several classical machine learning models trained on measurement-based classical data with that of quantum kernel-based models trained on pre-measurement coherent quantum states. Our objective is to isolate the impact of measurement-induced information loss and therefore provide a theoretical upper bound on the sensing performance. The upper bound is achievable only when coherent quantum information is directly available to the learning model. Our results show that QML-based sensing performance improves significantly with coherent quantum-state information, and not much with changes in model complexity or learning paradigm. This observation underscores the importance of learning pipelines that tightly integrate quantum sensors and QML models to enhance magnetic field sensing under realistic constraints.

0.21

Generative Quantum Machine Learning Methods for Cancer Detection using Augmented Datasets

eess.IV cs.CVcs.ETquant-ph ·2026-10-10 ·Sophia Knutson, Nandika Goyal, Gennaro De Luca, Glen Uehara, Tanay Kamlesh Patel +1 more
similarity 0.57
Abstract

Cancer detection using AI methods and image databases faces several challenges, including limited and imbalanced image datasets, long algorithm training times, and high-complexity feature generation. In particular, many cancer image datasets contain very few malignant examples compared to benign ones, limiting the amount of minority-class data available for training. Although classical AI and especially deep learning methods have had some success in providing cancer diagnostics, Quantum Machine Learning (QML) methods may offer advantages through high-dimensional feature representations, generative data augmentation, and the exploitation of feature correlations through quantum properties such as entanglement. In this paper, we propose using a generative QML method on the compressed breast ultrasound image dataset (BUSI) to generate synthetic images and hence augmented datasets for classifier training. In particular, we train a convolutional neural network with real, synthetic, and a combination of real and synthetic images. We test the algorithm on real images and provide comparative results for all three training cases. Our results show that the classifier trained entirely on synthetic images achieved an AUC-ROC of 0.802 (80.2%), compared with 0.760 (76.0%) for the real-data baseline.

0.15

Quantum Diffusion Models for Medical Image Analysis

eess.IV cs.AIcs.CVcs.ET+2 ·2026-09-25 ·Francesco Aldo Venturelli, Stefano Martina, Marco Parigi, Filippo Caruso, Alba Cervera-Lierta +1 more
benchmark similarity 0.56
Abstract · 12 pages, 12 supplementary pages, 7 figures, 1 table, 12 supplementary figures

Quantum Machine Learning is a novel field of research aimed at devising machine learning approaches exploiting principles of quantum mechanics, such as superposition, entanglement and interference. In this context, we present a scalable hybrid Quantum Diffusion Model, and evaluate its use for medical image analysis. Specifically, our method is based on a Discrete-Time Quantum Walk algorithm, executed on a real quantum device, to model the forward dynamics of the diffusion model. For the backward step of the diffusion model, we devise and evaluate a classical learning model, which is used to reversely denoise the data. In contrast with other existing attempts at applying quantum machine learning for image analysis tasks, severely limited by the size of existing quantum devices, our method allows to process real-world large size medical data. In particular, we present results on grayscale and RGB images, as well as 3D volumes of moderate sizes. We benchmark our results by reproducing an alternative classical counterpart model, based on diffusion models on discrete state spaces. By doing so, we compare the generation capabilities of both models in terms of three distinct state-of-the-art metrics in the field of image generation, showing the competitive, promising results of our approach.

0.48

Hybrid Quantum--Classical Pauli-Correlator Architecture for Image Reconstruction

cs.CV quant-ph ·2026-11-03 ·Sparsho Chakraborty, Siddhartha Patra
similarity 0.55
Abstract · 30 pages , 6 figures

We introduce the Pauli-Correlator Autoencoder (PCAE), a hybrid quantum--classical architecture for image reconstruction. PCAE splits an image into patches and compresses each patch as a matrix product state (MPS). A small quantum circuit turns each compressed patch into a few measured numbers, and a classical neural network rebuilds the patch from these numbers and the patch position. A learnable energy term, taken from physics, is added to training and tracked as training proceeds. Two versions place the six qubits on a line (PCAE1D) or on a grid (PCAE2D). An averaging step makes the PCAE2D features follow rotations and reflections of the image exactly. Trained on one image at a time, PCAE2D rebuilds images from six public datasets with a peak signal-to-noise ratio of 25.8 to 41.6 decibels. On CIFAR-10 images not used in training, a formula-based stand-in for the PCAE2D features performs within 1 decibel of several simpler classical methods. Five trained models also run on real IBM quantum computers without retraining, and rebuild images at 25.90 to 31.52 decibels. A short argument and a synthetic test show that, with a linear final layer, measuring qubits in pairs is needed for targets built from products of inputs. These results show that PCAE works as a hybrid model that rebuilds varied images and runs on today's quantum hardware at the six-qubit scale.

0.21

Coarse-to-Fine 3D MRI Reconstruction via Resolution-Agnostic Neural Operators

eess.IV cs.CV ·2026-11-11 ·Jiayun Wang, Ram Daftari, Weijie Gan, Valentin Duruisseaux, Ruibo Wang +3 more
published similarity 0.55
Abstract · NeurIPS 2026

Deep-learning-based 3D MRI reconstruction is limited in practice by the GPU memory and compute cost of full-volume training; 3D acquisitions are thus most often reconstructed by 2D models applied slice-by-slice and then stacked, which ignores through-plane (stacking-axis) structure. We reconstruct in full 3D and ask whether a model can be trained at low resolution (fast and memory-feasible) yet deployed at higher resolution. This coarse-to-fine strategy needs reliable cross-resolution performance, but standard networks are resolution-specific and degrade substantially when evaluated outside the training setting. We therefore use resolution-agnostic neural operators (NOs) and propose KIR-NO (k-space-to-Image Reconstruction Neural Operator), a discretization-agnostic framework for accelerated 3D MRI reconstruction. KIR-NO is trained with full backpropagation on low-resolution volumes and applied zero-shot to higher-resolution volumes at inference. Its core building block is a 3D neural operator based on discrete-continuous convolutions: convolutional filters are parameterized in a continuous basis and sampled at arbitrary voxel resolutions while preserving the local inductive bias of convolution. KIR-NO integrates these learned operators with physics-based consistency: a k-space neural-operator head first refines the undersampled Fourier measurements, and image-space neural-operator cascades then refine the reconstruction through interleaved data-consistency updates. Across 3D knee and brain MRI benchmarks, KIR-NO improves over classical and CNN baselines: it improves over a state-of-the-art 3D CNN by 2.2 dB PSNR at half resolution under 4x acceleration on SKM-TEA, with gains persisting at 8x and 16x. These results show that resolution-agnostic operators make coarse-to-fine 3D MRI reconstruction - cheap low-resolution training with high-resolution deployment - practical across anatomies.

0.27

Beyond sensitivity: mechanism-resolved error budgets for designing quantum sensors

eess.SY quant-phphysics.app-ph ·2026-08-28 ·Nima Leclerc, Marco Capelli, Kevin James Rietwyk, Mark Dong, Dmitry Lyakh +12 more
similarity 0.55
Abstract

Quantum sensors are specified by a headline sensitivity, yet applications also demand accuracy and reliability. The dominant limiter of one metric is often known, but no method resolves how interacting mechanisms combine into a signed, per-mechanism budget for each metric. We introduce a framework that computes a sensor's sensitivity, accuracy, and robustness from one open-system simulation and attributes each to its limiting mechanism. For a nitrogen-vacancy diamond ensemble the attribution inverts across metrics: dephasing limits sensitivity, the thermal ground-state shift limits accuracy, and optical leakage limits robustness. At identical sensitivity the recovered-field bias spans $8$ to $1500$\,nT, so tuning to sensitivity alone can miss the accuracy target by two orders of magnitude. The same modeling transfers to a cesium optically pumped magnetometer recording a human magnetocardiogram. As a digital twin, it predicts the gain from addressing each limiter, so sensors can be designed to the required metrics.

0.44

ZoomSEM: accelerating large-scale brain connectomics with intelligent SEM super-resolution

cs.CV ·2026-10-24 ·Jiateng Shou, Zhiwei Xiong, Ruikang Xu, Zhicheng Wang, Peiyao Shi +8 more
similarity 0.54
Abstract

Serial electron microscopy (EM) is essential for large-volume biological imaging and connectomics, yet its throughput remains a major bottleneck, with cubic-millimeter-scale brain imaging requiring months or years. Existing deep learning-based EM super-resolution methods are limited to small upscaling factors or rely on synthetic data, offering modest acceleration and limited practical impact. We introduce ZoomSEM, a deep learning-based super-resolution method to dramatically accelerate SEM imaging. Trained on real low- and high-resolution scanning electron microscopy (SEM) pairs, ZoomSEM enables reliable recovery of 4$\times$, 8$\times$, and up to 16$\times$ higher-resolution images from fast low-resolution scans while preserving fine neuronal structures critical for connectomic analysis, achieving up to 30-fold effective acceleration. Extensive experiments across datasets of diverse biological samples demonstrate robust generalization under realistic low-resolution acquisition. This advance enables high-resolution, large-volume serial EM imaging at unprecedented speed, poised to transform connectomics and related fields.

0.24