MedPhysBench: A Benchmark for Evaluating Language Models on Medical Physics Calculations and Error Detection

Omar Nusrat

cs.AI physics.med-phcs.CL ·submitted 2026-11-03 18:40 UTC · v1
benchmark

Abstract

Medical physicists turn a prescription into a delivered dose and check one another's calculations, because one error in a beam calibration or a monitor-unit (MU) calculation can affect every patient treated with it. MedPhysBench has ten seeded generators of calculation items in radiation therapy, diagnostic imaging, nuclear medicine and radiation protection, up to clinical tasks such as a TG-51 calibration worksheet. Reference answers come from code implementing the governing protocols, and a grader converts units and applies tolerance bands. From the same inputs, separate checking items test error detection, showing a colleague's worksheet or only the colleague's result, half correct and half with one planted error. On a held-out test split of 1,200 items (half for two models), 12 models scored 33.3 to 100.0% on calculation. Of the nine answers graded incorrect for the four best (99.3-100.0%), five contained model errors and four followed NCRP Report 151 on points our items misstate or leave open. Below them, most models did worst on level-3 clinical tasks, and Claude Sonnet 5.5 omitted the inverse-square correction in 19 of 20 isocentric MU items. Five models detected at least 96.7% of mostly large planted errors with at most 4% false alarms; for four of the other seven, checking only the result raised false alarms significantly. In an exploratory targeted test with 20 public cases of an omitted inverse-square correction, the three best models tested caught it in every worksheet, and three weaker models accepted 16 to 18 of 20 planted worksheets, one of them while applying the correction in most of its own calculations. Claude Opus 5.5 accepted 6 of 20 wrong results, although it applied the correction in all 20 of its own. We report the effect of two problems in our shielding items, found after the runs, and release the code, per-item outcomes and targeted-test responses.

Closest papers

Nearest neighbours by meaning across the whole index.

Same Patient, Different Order: Action-Level Reliability of Clinical LLM Agents Under Repeated Runs

cs.CL cs.AIcs.LGcs.SE ·2026-09-11 ·Rohith Reddy Bellibatlu, Manpreet Singh, Zhoutian Han, Wenbin Zhang
benchmarkcode/data similarity 0.59
Abstract · 13 pages, 2 figures, 3 tables. Code, run records and the rerun harness: https://anonymous.4open.science/r/clinical-agent-action-reliability …

A clinical agent benchmark can report the same verdict on identical inputs while the agent files a materially different order on each run. Such agents order tests, request medications and place referrals, yet benchmarks typically score one run per task and rarely ask whether identical inputs produce identical actions; MedAgentBench, the benchmark we use, scores a single attempt and says so. To measure this gap we introduce "same-input rerun", which replays a task with every input held fixed and compares the orders rather than the score, with six reliability metrics, and apply it to 1000 MedAgentBench runs across 50 tasks from its five write-capable families, two open-weight models below ten billion parameters quantised to four bits, and two temperatures. The study establishes that action-level divergence exists and can pass unrecorded by the score, not that any rate generalises. Under the 8B model at temperature 0.7, all 43 ordering groups emit a different set of orders across five identical runs, 26 emit the order on some runs and not others, and 28 record a different coded value, dose or analyte. In 22 of those 43 the benchmark reports the same failing verdict for materially different behaviour, as it does for all 10 divergent groups of the 4B model at 0.7. Orders also reach different endpoints across runs, one of which the record server rejects while the agent is told it succeeded. These findings motivate repeated-run evaluation, action-level stability reporting and execution-faithful environment feedback in clinical-agent benchmarks.

0.70

Are We Grading Properly? Understanding Failure Modes in Medical Benchmarks

cs.CL cs.LG ·2026-09-10 ·Prithvi Dixit, Pedram Hosseini
similarity 0.58
Abstract

Medical evaluation is shifting from static option-based questioning to realistic clinical scenarios with open-ended output modes. Grading these at scale naively, however, is expensive, and rubric-based evaluation has become the dominant scalable alternative. We ask what happens when the rubrics themselves are not airtight, and whether such flaws can be detected and corrected. We apply RIFT, a global rubric failure taxonomy, to two clinical benchmarks (HealthBench Professional and LiveMedBench), and find failure modes are meaningful: on HealthBench Professional an LLM judge flags 29.6% of criteria as non-atomic and 65.4% as misaligned/rigid. Then, we show that these flaws are meaningful and not simply cosmetic. As an example, rewriting bundled criteria of the form "at least one of / all of the following" as equally weighted children and regrading identical responses shifts scores by up to 15.9 percentage points on affected conversations, with disjunctive bundles inflating scores and conjunctive bundles deflating them. We also find that RIFT generally under-detects bundling on clinical rubrics, flagging 3.3% of LiveMedBench criteria as non-atomic where surface-form analysis finds structure in 25.8%.

0.33

RadMatch: Auditable Radiology Report Evaluation via Finding-Level Matching

cs.CV ·2026-09-01 ·Charles Corbière, Léo Machado, Aubin Charley, Baptiste Callard, Pierre Manceron +1 more
publishedcode/data similarity 0.58
Abstract · Accepted to ECCV 2026 Workshop on Medical Foundation Models and Benchmarks

As AI systems are increasingly used to draft radiology reports, reliably evaluating their clinical quality remains a critical challenge. Large language model (LLM)-based metrics are now the best-correlated with radiologist judgment, yet they output a single opaque score that neither a clinician nor a model builder can easily interpret or audit. We introduce RadMatch, a multi-stage, LLM-based metric that decomposes report comparison into a structured finding-level matching with significance-aware scoring and error characterization across seven clinical attribute dimensions (status, location, severity, morphology, certainty, longitudinal comparison, and measurement). The main score is the actionable-error count, both interpretable and auditable. Candidate findings are graded correct, partial, or incorrect, and unmatched findings are counted as missed or hallucinated. Triage and actionable safety recall/precision and per-subset views add complementary, deployment-oriented lenses. Across two expert benchmarks, RadMatch is the most clinically aligned metric, matching inter-radiologist agreement on ReXVal and more than doubling the best prior metric on the harder RadEvalExpert. Relying only on few-shot prompting, it is designed to extend to other modalities and anatomies. We will release RadMatch as open-source code with an interactive dashboard for inspecting results.

0.53

Scientific Agents: Evaluating Profession-Specific System Prompts on Scientific Tasks

cs.AI cs.CL ·2026-09-07 ·Timothy Kassis
benchmarkcode/data similarity 0.57
Abstract · 46 pages (11 pages main text, references, 33-page appendix); 10 figures, 29 tables. Evaluated corpus: https://github.com/K-Dense-AI/scientif…

Detailed profession-specific system prompts raise token use and estimated cost per response without a consistent accuracy gain. We evaluate Scientific Agents, an open-source corpus of 503 profession-specific AGENTS.md profiles, with Gemini 3.8 Flash via OpenRouter in the Pi agent harness. We compare matched profiles with four controls: a minimal baseline ("You are a helpful assistant"), the profile's opening role sentence, a generic scientific rigor guide, and a profile from an unrelated domain. Across nine text-based science benchmarks (4,531 sampled questions, 100 matched profiles), 4,488 items completed all five conditions after API-error retries, scored with automated, rule-based grading. The average profile-baseline accuracy difference is -0.6 percentage points (95% bootstrap interval [-1.5, +0.2] across fixed tasks), and no benchmark shows a statistically clear improvement. Matched profiles produced 1.5-2.3 times as many output tokens and cost 2.2-4.5 times more per successful call. On 60 tool-using BioMysteryBench bioinformatics problems (three runs each for baseline and profile), mean solve rates were 46.7% with the profile and 56.7% at baseline, a difference of -10.0 percentage points (95% interval [-16.7, -3.3]) driven by more frequent token- and time-limit stops under the profile. Longer prompts had one unexpected operational advantage: on SuperGPQA, frequent provider API drops left the short baseline with a correct first-pass answer on only 54.0% of items, against 71.6% with the profile. Generic and mismatched prompts were about as reliable, so this gain comes from prompt length or formatting rather than domain expertise. For the tested model and tasks, loading full profession profiles by default does not improve accuracy and costs considerably more; whether selective retrieval of profile sections or open-ended scientific tasks would change this remains to be tested.

0.34

An evidence-traceable benchmark of clinical reasoning in large language models

cs.CL ·2026-11-10 ·Zhiqun Zhao, Xiaodong Yang, Bruce Gu, Ming Li, Yi Fu +11 more
benchmark similarity 0.57
Abstract · 25 pages, 8 figures, 4 tables. Zhiqun Zhao, Xiaodong Yang and Bruce Gu contributed equally. Corresponding authors: Zheng Wang, Haiquan Lu an…

Benchmark scores for medical large language models (LLMs) are difficult to interpret when scoring criteria cannot be traced to clinical evidence. Here we developed Med Evidence Bench (MEB; https://www.medevidencebench.org.cn/), comprising 1,536 physician-constructed items across three levels: guideline knowledge, standardized clinical scenarios and real-world laboratory scenarios. Each criterion stating a medical claim is linked to a versioned source-text span. Across ten LLMs, the Evidence Trace Score (ETS) was 0.975-0.997 for guideline knowledge, 0.292-0.658 for standardized scenarios and 0.182-0.447 for real-world scenarios, and rankings varied across levels. For real-world scenarios, scores for identifying clinical information (mean, 0.770) exceeded those for matching evidence (0.165) or formulating recommendations (0.160). On 1,296 criterion-level judgments, automated grading agreed with the majority vote of three physicians (macro-F1, 0.930; 95% confidence interval, 0.915-0.945), although agreement was lower for evidence application. These findings from Chinese-language materials indicate that guideline recall does not ensure patient-specific evidence use and do not establish clinical effectiveness.

0.25

Supervision-Aware Evaluation of MedGemma for Reference-Assisted Radiotherapy Contour Ranking

eess.IV cs.CVcs.LG ·2026-11-11 ·Jaden Moon, Caiwen Jiang, Songlin Zhao, Wei Liu
similarity 0.57
Abstract · 5 pages, 1 figure, 3 tables. Submitted to IEEE ISBI 2027

Radiotherapy contour ranking can support quality assurance, but vision-language model (VLM) gains may reflect supervision, score construction, available inputs, or representation access. We evaluated frozen MedGemma 1.5 in a single-institution study, a 12-patient held-out HaN-Seg test, five-fold cross-fitting on 30 non-test HaN-Seg patients, and transfer without refitting to 120 SegRap2023 patients. On held-out HaN-Seg, a supervised readout of the final prompt state exceeded a supervised readout of the model's yes/no output probabilities by +0.3047 pooled average precision (AP; 95% patient-bootstrap interval [+0.2822, +0.3269]); the advantage persisted against a parameter-count-matched nonlinear control. A readout of projected visual tokens exceeded the final-state readout in cross-fitting and transfer (+0.0706 AP averaged equally across patients on SegRap; 95% interval [+0.0607, +0.0804]), while a structured panel-feature readout remained competitive with visual tokens. The anatomy-conditioned readout did not demonstrate an advantage over the native-feature comparator. These results motivate visual-token and structured-feature controls in medical-imaging VLM evaluations; outcomes were computational or synthetic, not clinical acceptability.

0.22

The Value of System 1 Models in Medicine

cs.LG ·2026-10-22 ·Xiufeng Yang, Konstantinos Vrettos, Zeineb Ben Chaaben, Fabian Drexel, Jannik Lübberstedt +15 more
similarity 0.57
Abstract · 27 pages, 6 figures; includes Supplementary Appendix (3 figures, 5 tables)

Many clinical decisions are a choice among a few fixed options, taken quickly and in large numbers. Such decisions also need an uncertainty estimate to know when to defer to a clinician. Generative language models answer slowly in free text and state their confidence poorly. In contrast, System 1 models answer zero-shot with a probability for each answer. However, their performance across clinical tasks is unknown. Four System 1 models, two proprietary and two with open weights, were evaluated zero-shot on 86 public tasks from 14 clinical domains in 20 languages, spanning examination questions and medical imaging. Tasks were assigned to six capability tiers before analysis. The primary outcome was the area under the receiver-operating-characteristic curve (AUROC). Secondary outcomes included calibration, language effects and comparisons with published results and generative models. Across 179,111 cases, the mean AUROC of the best model per task was 0.94 for medical knowledge, 0.93 for text understanding, 0.83 for clinical judgement from text, 0.89 for image perception, 0.84 for 2D image findings and 0.69 for volumetric findings. Imaging tasks scored 0.09 (95% CI, 0.06 to 0.11) lower than text tasks (P < 0.001). The best model matched or exceeded the best published result on 13 of 26 text tasks and on 8 of 35 imaging tasks. Triage nurses outperformed the best model (accuracy, 0.85 vs. 0.56). One decision took 0.34 to 0.44 seconds and 24 to 81 joules on open-weight models run locally. Accuracy on identical questions fell by up to 39 percentage points from English to Yoruba. Generative models of the same family were 11 to 76 times slower, with 3 to 5 percentage points higher balanced accuracy. System 1 models decide quickly, cheaply and with usable confidence when the answer is stated in a text or recalled from medical knowledge, but not when it must be judged or read from an image.

0.52

Multimodal Error Detection in Chest X-ray Reports: A Large Language Model Reading Image Evidence

cs.CL ·2026-11-19 ·Yanda Cheng, Bo Wen, Yuhao Lu
similarity 0.57
Abstract · 34 pages, 4 figures, including supplementary material

Rad-Linter checks chest X-ray reports against image-derived evidence to flag potential errors for review. A pretrained image classifier supplies scores for nine pathologies, and a 1.5B-parameter language model, fine-tuned with LoRA on 1,816 examples, checks their consistency with the report. We compare it with a keyword-and-negation rule baseline given the same reports and scores. Evaluation uses controlled report-score pairings from OpenI, with consistency labels derived from automatic report labels and score thresholds. Each counterfactual quad crosses two real reports with two real score vectors from other patients, creating two consistent and two inconsistent pairs. Every report and score vector occurs in both conditions, so either input alone permits only 50% accuracy. On 131 quads, Rad-Linter achieves 98.5% pair accuracy versus 80.5% for the rule baseline, and classifies all four pairs correctly in 94.4% of quads versus 56.5%. The checkers perform similarly on omission items, including unmentioned and negated findings; larger differences occur on the remaining item types, which require interpreting how findings are described. The same language model without fine-tuning remains near 50% accuracy. On a second set of 181 quads that also includes reports on which the automatic labelers disagree, pair accuracy is 93.4% versus 75.3%. These controlled results show that, given the same image-derived scores, a trained language model detects report-score inconsistencies more accurately than the tested rule baseline, with the advantage concentrated in interpreting how findings are worded.

0.24