CS Paper Radar

Region-Wise Logit Fusion and Utility-Gated Refinement for Brain Metastasis Segmentation

Zhenye Lou, Qing Xu, Wenting Duan, Zhen Chen

cs.CV cs.AI ·submitted 2026-11-10 10:44 UTC · v1
publishedcode/data

Abstract

BraTS-METS 2026 Task 1 evaluates segmentation of brain metastases and postoperative resection cavities on heterogeneous multiparametric MRI, requiring detection of small enhancing foci while preserving the geometry and hierarchy of enhancing tumor (ET), tumor core (TC), whole tumor (WT), and resection cavity (RC). We present COMPASS-METS (Component-Aware Multi-Trainer Probability Assembly with Structured Segmentation), which combines three five-fold nnU-Net configurations into aligned regional probability ensembles. A structured-probability anchor applies region-specific component decisions, TC boundary completion, RC filtering, and hierarchy-preserving conversion. Omitted ET candidates are recovered additively using learned component confidence and deterministic multi-trainer support for ET and its TC/WT parents; a final utility gate admits only disconnected candidates with sufficient lesion-existence and geometry-safety probabilities. On the reused 179-case challenge development cohort, COMPASS-METS (Team: MicroBT) achieved Small F1 0.354, lesion-wise DSC 0.712, NSD 0.714, All F1 0.779, and HD95 56.6 mm. Relative to ResEncXL, it improved DSC, NSD, and All F1 and reduced HD95, while Small F1 changed from 0.367 to 0.354. Stagewise analysis attributes the principal geometric gains to structured probability construction and shows that guarded ET refinement recovers most of the associated small-lesion detection loss. These 179-case results remain selection-aware development estimates. The source code is publicly available at https://github.com/leonlou921/COMPASS-METS.

Comment
Accepted at the Brain Tumor Segmentation Challenge - Metastases (BraTS-METS), held in conjunction with MICCAI 2026

Closest papers

Nearest neighbours by meaning across the whole index.

CarveMix-RC: Addressing Rare-Class Imbalance Through Lesion-Aware Synthetic Augmentation for Brain Metastasis Segmentation

cs.CV cs.AI ·2026-09-28 ·Md Shibly Sadique, Md Fayaz Bin Hossen, Michael L. Evans, Walia Farzana, Asfaqur Rahman +2 more
benchmark similarity 0.77
Abstract · 14 pages, 2 figures, 2 tables

Accurate segmentation of post-treatment brain metastases is essential for treatment planning, longitudinal disease monitoring, and quantitative assessment of therapeutic response. The BraTS-MET 2026 Task 1 challenge introduces a clinically relevant segmentation problem involving four anatomically distinct tumor subregions: non-enhancing tumor core (NETC), surrounding non-enhancing FLAIR hyperintensity (SNFH), enhancing tumor (ET), and the resection cavity (RC). Among these, RC segmentation is particularly challenging because of its low prevalence, heterogeneous postoperative appearance, and lesion-wise evaluation protocol, leading conventional segmentation networks to prioritize dominant tumor classes during optimization. The proposed nnU-Net-based framework explicitly addresses RC segmentation through four complementary components: (i) RC-weighted Dice and Cross-Entropy optimization to alleviate class imbalance, (ii) anatomically consistent cavity augmentation to increase the diversity of postoperative cavity appearances, (iii) a residual encoder architecture for enhanced multi-scale feature learning, and (iv) lesion-aware morphological post-processing to suppress false-positive cavity predictions while preserving anatomically plausible structures. The framework is evaluated on the BraTS-MET 2026 Task 1 online validation benchmark. Among the evaluated configurations, the ensemble model (Residual Encoder nnU-Net + nnU-Net + RC-aware CarveMix) achieves the best performance, with lesion-wise Dice scores of 0.732, 0.752, 0.708, and 0.575 and corresponding NSD scores of 0.794, 0.798, 0.727, and 0.474 for ET, TC, WT, and RC, respectively. These experimental results show that integrating RC-aware optimization, anatomically consistent augmentation, and lesion-aware post-processing provides an effective strategy for improving rare resection cavity segmentation in post-treatment brain metastases.

0.08

Pre- and Post-Treatment Brain Metastases Segmentation Using nnU-Net with Post-Processing for BraTS 2026

cs.CV ·2026-09-10 ·Haobin Liu, Xin Wang
publishedbenchmarkcode/data similarity 0.75
Abstract · Accepted to MICCAI 2026 Challenge BraTS-METS

Brain metastases exhibit high inter-lesion variability in size, enhancement pattern, and post-treatment appearance, making volumetric segmentation of both pre- and post-treatment cases the central challenge of the BraTS 2026 Task 1 (Brain Metastases). We build a pragmatic pipeline on a 5-fold nnU-Net ResEnc-L ensemble, in which each fold is trained independently for 1,000 epochs with the standard Dice + cross-entropy loss on 1,296 four-modality training cases. This ensemble is followed by a rule-based post-processing cascade tuned for the lesion-wise Dice similarity coefficient (LW-DSC), a detection-oriented metric that behaves very differently from the traditional global Dice. The final pipeline reaches an LW-DSC of 0.733 / 0.751 / 0.713 / 0.549 on the enhancing tumour (ET), tumour core (TC), whole tumour (WT), and resection cavity (RC) sub-regions on the official validation leaderboard. Rather than trusting these leaderboard gains, we audit every post-processing stage with a five-fold out-of-fold (OOF) analysis with no model-training leakage over all 1,296 training cases, scored with the official BraTS evaluation code (BraTS_evaluation): it confirms two stages as robust, per-fold-consistent improvements while the third improves only the leaderboard and does not reproduce out-of-fold. We further provide a mechanistic analysis of the LW-DSC metric that explains why recall-recovering post-processing carries low risk whereas component deletion does not, and we report thirteen negative results spanning loss engineering, alternative backbones, and inference-time settings, several of which run counter to widely held intuitions. Source code is released under Apache-2.0 at https://github.com/hornbeamliu/brats2026-met.

0.48

A Simple yet Effective Framework for Pre-treatment and Post-treatment Glioma Segmentation Using Multimodal MRI

eess.IV ·2026-10-01 ·Lin Qu, Ziqi Chen, Anqi Wu, Jinyao Shen, Hai Shu
published similarity 0.71
Abstract · The proposed method won second place in the MICCAI 2025 BraTS Lighthouse Challenge on Glioma Segmentation on Pre- and Post-Treatment MRI (Br…

Accurate glioma segmentation across pre- and post-treatment MRI remains challenging because treatment alters both image appearance and the target regions. In particular, the resection cavity (RC) is defined only for post-treatment cases, complicating joint learning from pooled data. We present RC-aware nnU-Netv2, a simple yet effective glioma segmentation framework that combines lesion- and boundary-aware single-cohort training, an RC-aware joint learning objective, and treatment-status-guided model routing at inference. During pooled training, the joint objective applies both standard and boundary-weighted binary cross-entropy to all four region channels, while employing Dice supervision for channels with non-empty targets and a controlled false-positive penalty for channels with empty targets across the mini-batch. This design explicitly accommodates the absence of RC in pre-treatment cases. Our approach uses only the standard nnU-Netv2 data augmentation and a single specialized model per case, without additional synthetic tumor generation or multi-model ensembling. RC-aware nnU-Netv2 ranked second in the BraTS 2025 Lighthouse Challenge Task 1 (BraTS-GLI 2025), with segmentation performance comparable to that of the first-place method, which relied on on-the-fly GliGAN-based synthetic tumor augmentation and multi-model ensembling. On the official blind test set, our method achieved mean lesion-wise Dice scores of 0.7878, 0.8709, 0.7923, and 0.8715 and mean NSD@1.0 scores of 0.8309, 0.8712, 0.7980, and 0.8336 for enhancing tumor, RC, tumor core, and whole tumor, respectively. In paired post-treatment analysis, the RC-aware joint model improved mean lesion-wise Dice by 0.042 (95% CI: [0.028, 0.057]) and mean NSD@1.0 by 0.043 (95% CI: [0.028, 0.059]) compared with the joint baseline.

0.13

MicroBT: Centroid-Guided Synergistic Learning for Multi-Modal Micro Brain Tumor Segmentation and Counting

cs.CV cs.AI ·2026-11-10 ·Zhenye Lou, Qing Xu, Stefanie Thust, Dorothee P. Auer, Zhen Chen +1 more
publishedcode/data similarity 0.69
Abstract · Accepted at the 37th British Machine Vision Conference (BMVC), 2026

Multi-modal brain tumor segmentation is essential for clinical diagnosis, radiotherapy planning, and longitudinal monitoring. While recent studies have achieved remarkable overall segmentation performance, they rely on overlap-based objectives that inherently favor large regions, causing sub-3 mm micro-lesions to be systematically suppressed during training. Moreover, existing pixel-level segmentation frameworks lack explicit instance-level modeling, leading to unreliable lesion counting that directly impacts clinical staging and therapeutic decisions. To address these challenges, we propose MicroBT, a unified multi-modal framework for micro brain tumor segmentation and counting. Our core insight is that a fundamental geometric property is inherently scale-invariant: regardless of size, each lesion possesses a well-defined centroid. Leveraging this, we first devise a centroid-anchored synergistic paradigm that utilizes predicted centroids as shared anchors to simultaneously condition dense segmentation and instance-level localization. To counteract the tumor size imbalance, we further devise a Volume-Calibrated Loss (VC-Loss) that adaptively amplifies the gradient contribution of micro-lesions, alongside a Size-Aware Curriculum Optimization (SACO) that stabilizes multi-task training by establishing global representations before progressively unlocking fine-grained localization. Extensive experiments demonstrate that MicroBT outperforms state-of-the-art methods, particularly on metastases, where micro-lesion ($\leq 3$ mm) localization precision improves by approximately 7% and counting estimation errors decrease by approximately 26%. The code is available at https://github.com/leonlou921/MicroBT.

0.49

Brain Metastases Segmentation for BraTS 2026 Task 1: A Multi-Architecture Comparison

cs.CV ·2026-09-21 ·Mahdi Islam, Musarrat Tabassum
publishedcode/data similarity 0.69
Abstract · 10 pages, 1 figure. Accepted as a poster at the BraTS 2026 Challenge, MICCAI 2026. Code: https://github.com/mahdiislam79/BraTS_METS_2026

Brain metastases are the most common intracranial malignancy, occurring in roughly 30% of patients with primary solid tumors and carrying a median survival near 5.9 months. Automated segmentation is critical for treatment planning and volumetric monitoring, but metastases are frequently small, numerous, and heterogeneous in size within a single patient. We compare a plain nnU-Net baseline, a Residual Encoder Large (ResEncL) variant, region-based training, and a Primus transformer model for BraTS-METS 2026 Task 1, using patient-grouped cross-validation to prevent leakage from the longitudinal UCSD subset. Primus (label-based) is our strongest individual model by aggregate DSC/NSD, achieving 0.710/0.761 (ET), 0.742/0.785 (TC), 0.683/0.689 (WT), and 0.531/0.436 (RC). ResEncL trails Primus on aggregate DSC/NSD but achieves substantially higher lesion-wise F1 (e.g. ET: 0.452 vs. 0.052); a probability-averaging ensemble of the two only partially preserves ResEncL's F1 advantage (ET lesion-wise F1: 0.064). We further report three postprocessing and label-reconstruction pitfalls we believe generalize beyond this challenge. Code is available at https://github.com/mahdiislam79/BraTS_METS_2026.

0.31

Progressive multi-scale tumor-state memory for incomplete multimodal brain tumor segmentation

eess.IV cs.CV ·2026-10-19 ·Milad Rostamian, Mohammadreza Mohammadi, Mohsen Soryani
similarity 0.69
Abstract

Brain tumor segmentation uses complementary magnetic resonance imaging (MRI) sequences, but some sequences may be unavailable in practice. Their absence changes the information available for segmenting different tumor regions. Fusion methods can support different input subsets. However, fusion at several scales does not by itself specify how tumor evidence is retained and updated to guide fusion at later stages. We propose a progressive multi-scale tumor-state memory network (PMTM) for segmentation from any non-empty subset of T1ce, T1, FLAIR, and T2. PMTM maintains a compact state for the current subject across the encoder stages. At each stage, we use assignment maps to pool spatial features into ordered evidence vectors for each available modality. We average these vectors across the available modalities, and a learned gate combines this evidence with the previous state. The up- dated state guides residual fusion at that stage and is used in the state update at the next stage. A modality-token mixer also models interactions among the available modalities at each stage. We apply semantic supervision to the assignment maps at all four stages. We evaluate PMTM on BraTS2018, BraTS2020, and BraTS2023 GLI across all 15 non-empty modality subsets. Averaged over the three tumor regions and the 15 subsets, PMTM achieves Dice scores of 75.31%, 77.54%, and 80.47% on BraTS2018, BraTS2020, and BraTS2023 GLI, respectively. These scores are higher than those of RobustSeg, RFNet, and mmFormer in our experiments on each dataset. Component ablations and internal state analysis are performed on BraTS2020.

0.06

Assessing nnU-Net Generalization across Brain Tumor Populations in BraTS-GoAT 2026

cs.CV eess.IV ·2026-09-14 ·Tristan Kirscher, Vivian Metzger, Philippe Meyer, Xavier Coubez
published similarity 0.67
Abstract

BraTS-GoAT evaluates tumor segmentation across heterogeneous populations. We trained a conventional 3D nnU-Net on 1,351 labeled cases using five-fold cross-validation and 1,000 epochs per fold. The final predictor averaged all folds and applied test-time mirroring. On pooled official validation, global DSC values were 0.7805, 0.8288, and 0.8854 for enhancing tumor (ET), tumor core (TC), and whole tumor (WT). Under matched fold-0 inference, mean regional Dice decreased from 0.9058 on source out-of-fold (OOF) cases to 0.8310 on pooled validation (difference--0.0747). Mirroring gave small single-fold gains but no clear ensemble benefit; a residual-encoder alternative reached 0.8282 mean Dice. In labeled OOF predictions, failure cases had substantially smaller reference ET volumes; after adjustment for ET and WT volume, lower Dice remained associated with more disconnected ET components and a smaller fraction of ET contained in the largest component.

0.19

FSS-UBrain: Multi-region Few-Shot Brain Tumor MRI Segmentation

cs.CV ·2026-09-26 ·Truong Viet Vu, Nguyen Phuc Nguyen, Dang Thi Thu Hang, Tran Thien Thanh, Vo Nguyen Quoc Bao +2 more
published similarity 0.67
Abstract · This work has been submitted to the Elsevier for possible publication. Copyright may be transferred without notice, after which this version…

Accurate delineation of whole tumor (WT), tumor core (TC), and enhancing tumor (ET) from multimodal magnetic resonance imaging remains challenging under limited annotation, cross-cohort variation, and severe target sparsity. We propose FSS-UBrain, a region-wise one-shot segmentation framework that uses a labeled positive support slice to condition binary query segmentation separately for WT, TC, and ET. Support-derived foreground and background descriptors guide query-feature adaptation, bottleneck interaction, decoder-side reconstruction, and boundary refinement. Episodic training additionally incorporates hard-negative and fully negative queries with empty-query regularization to suppress spurious foreground activation when the selected region is absent. Although inference operates on two-dimensional support--query slice pairs, checkpoint selection, threshold calibration, and final evaluation are performed after volumetric reconstruction. FSS-UBrain is evaluated on a held-out BraTS 2020 split and under target-supported cross-cohort protocols on BraTS 2023 and BraTS-Africa. Cases used as target support are excluded from the query cohorts, and no target-domain fine-tuning or test-time parameter updates are performed. On BraTS 2020, FSS-UBrain achieves volumetric Dice scores of 89.82%, 82.14%, and 77.42% for WT, TC, and ET, respectively, with corresponding 95th-percentile Hausdorff distance (HD95) values of 11.12, 9.01, and 4.46 mm. It also achieves the highest mean Dice and lowest finite-pair mean HD95 point estimates on BraTS 2023 and BraTS-Africa among the compared few-shot methods. These findings support target-conditioned few-shot segmentation while highlighting sensitivity to support selection and cohort-specific variation.

0.24