CS Paper Radar

When to Trust Simulated Patient Responses:Support-Gated World Models for Vasopressor Decision Support

Yifan Jin, Tao Liu

cs.AI ·submitted 2026-11-13 17:28 UTC · v1

Abstract

Clinical world models expose language-model agents to predicted patient responses, but simulations can be unreliable for poorly supported treatments or unfamiliar hospitals. We introduce Support-Gated World-Model decision support, a lightweight extension of a propose--simulate--refine agent. A recurrent dynamics ensemble predicts short-horizon physiological responses to documented norepinephrine dose categories, while a behavior model estimates observational action support. The interface withholds predictions with insufficient support or excessive ensemble disagreement and abstains when no candidate qualifies. Evaluation on eICU-CRD includes 70 hospitals and 30,700 decision transitions, with 14 hospitals held out for testing. At 62.0% factual-transition coverage, joint gating yields a MAP mean absolute error of 7.3 mmHg, compared with 9.2 mmHg for random selection at the same coverage. The gated agent achieves 60.0% agreement with recorded actions at 81.0% decision coverage, compared with 55.0% agreement and 99.5% coverage for an ungated ensemble agent. Component ablations show lower factual risk with joint gating than with either gate alone.These results characterize a reliability--coverage trade-off in selective clinical simulation; they do not identify individualized treatment effects or establish improved patient outcomes.

Closest papers

Nearest neighbours by meaning across the whole index.

Instability Floors: Separating Bias from Noise in Fairness Audits of Clinical LLM Agents with FairMedAgent

cs.CL cs.AIcs.CYcs.LG+1 ·2026-09-02 ·Rohith Reddy Bellibatlu, Manpreet Singh, Deepak Parashar, Rahul Joshi
code/data similarity 0.67
Abstract · 27 pages (13 main plus 14 supplementary), 4 figures, 3 tables. Code: https://github.com/rohithreddybc/FairMedAgent (v0.1.5, commit 3982974; …

Counterfactual fairness audits of clinical language-model agents report a flip rate: how often an action changes when only the patient's demographic descriptor changes. Part of that rate is not demographic. A stochastic agent also changes its own action when nothing changes, and a flip rate cannot be interpreted without knowing how often. We measured it. Re-running one condition ten times over sixteen synthetic vignettes at default sampling changed a clinical agent's action in 8.7 percent of replicate pairs, from 2.2 percent for intensive-care escalation to 17.9 percent for controlled-substance caution, an output given no operational criteria. Across six models from five vendors, pooled floors ranged from 2.5 to 23.7 percent; in this panel neither disclosed size, vendor, nor hosting ordered them. The floor depends on the decoding configuration: majority voting over five draws removed 39 percent of it (95 percent confidence interval (CI) 18 to 64); at temperature 0 three of four locally served models showed no disagreement, but a hosted model still did. We also show that, for a binary action, the flip rate expected under no demographic effect equals the floor and a real effect adds only its square, so a flip rate inside the floor is not evidence of fairness, and direction must be tested with a signed paired test. We give a four-step reporting procedure and release FairMedAgent, the harness, with its protocol, vignettes and analysis scripts, so any team can measure the floor for its own agent.

0.38

Intervention Granularity Matters: Coherent Treatment Bundles in Counterfactual Simulation with Clinical World Models

cs.LG ·2026-09-18 ·Fangzhou Wang, Yixuan Yang, Camilla Balzarotti, Rishikesan Kamaleswaran
similarity 0.66
Abstract

Counterfactual simulation with a clinical world model means fixing a patient's history, changing the treatment, and reading off the predicted response. Doing so requires deciding what counts as one intervention. In clinical settings, interventions are documented as bundles: a co-occurrence audit of 945,707 patient-hours from MIMIC-IV shows groups of components, such as every parameter of a dialysis circuit, that never appear apart, so an edit that changes one component on its own describes an hour that never occurs in the data. We hypothesize that the granularity at which an intervention is edited changes how a world model responds, and test this with Clin-JEPA, a latent world model of patient trajectories conditioned on hourly treatment text. At 1,019 documented onsets of invasive ventilation, we keep the patient's history and other treatments fixed and compare editing one ventilator setting with editing the complete configuration recorded for a real patient with the most similar recent trajectory. The complete bundle moves the predicted next state further than any single setting, consistently across all five settings, and the difference remains after accounting for how much each edit changes the model's input. Intervention granularity therefore materially affects the response of a clinical world model: single-component edits may understate treatment sensitivity, and bundle-aware editing may offer a better-supported basis for counterfactual treatment simulation.

0.31

Auditing Escalation Reliability in Healthcare LLM Agents: A Perturbation-Controlled Benchmark of Workflow-State Failures

cs.AI cs.CL ·2026-10-15 ·Zihao Zheng, Junyi Yao, Baichuan Li, Jiayu Long
benchmark similarity 0.65
Abstract · 8 pages, 5 figures

Trustworthy biomedical AI requires reliable action selection when evidence is missing, stale, conflicting, or late, not only accurate answers on static inputs. We instantiate an episode-level evaluation protocol as 400 synthetic healthcare workflow episodes: 40 hand-authored semantic seeds across four task classes, two surface parameterizations, and five controlled variants, scored on ANSWER/ASK CLARIFICATION/ABSTAIN/ESCALATE under a pre-declared 5:1 missed-versus-unnecessary escalation cost. Reference actions are single-author study-policy labels, not clinician-adjudicated ground truth. Across five open-weight configurations (1.7B--9.7B), clean decision accuracy reaches 0.97, yet uncertainty-prompted models miss 32--97% of required escalations. The stronger 9.7B configuration narrows but does not remove the gap, falling from 0.97 clean accuracy to 0.78 under conflict. Verbalized confidence is inconsistent (ECE 0.10--0.54; failure AUROC 0.48--0.77), and a development-tuned confidence-only policy yields no utility gain. A transparent workflow-aware controller improves 5:1 utility for every model and reduces missed escalations to 0.12--0.24, at specificity 0.83--0.93. However, a 30-concept lexical stress test reduces each rule detector's recall from 1.00 on trigger phrases to 0.00 on unseen paraphrases, limiting the controller claim to this benchmark. Seed-clustered statistics, ablations, cross-task transfer, raw outputs, and manifests are packaged for audit. The results motivate explicit workflow-state evaluation while showing that apparently effective routing controls need their own generalization tests.

0.46

Native Probability Outputs for Clinical Triage: An Evaluation of Calibration and Decision Accuracy

cs.LG stat.AP ·2026-10-17 ·Liang You, Zhiyin Zhou, Dawei Tang, Chuchu Wu, Jingzhuo Hu
similarity 0.62
Abstract

Patient-facing triage requires an appropriate care recommendation and recognition of when information is insufficient. We evaluate whether Jev, a decision model that returns probabilities over predefined actions, supports both judgments. Using CARE-Bench, we compare Jev with four general-purpose language models and three input-independent baselines across 925 decision points from 439 public cases. On the public test subset, Jev ranks fourth of five models by macro-F1 (0.461) but has the lowest observed multiclass Brier score (0.610), an 18.7\% improvement over uniform prediction (case-bootstrap 95\% interval, 4.9--31.1\%). Noul has lower binary Brier than Choice (0.215 versus 0.276). A evaluation of 453 HealthBench conversations again gives Jev the lowest observed Brier score (0.299), but measures a distinct emergency-referral judgment. Jev combines lower probability error with missed clarification needs in the four-action task. Asking about information sufficiency separately increases recall but also produces frequent unnecessary clarification assignments.

0.10

EGIP: An Evidence-Grounded Interaction Protocol for Clinical Agents

cs.CL ·2026-10-17 ·Zecheng Ren, Ruichen Cong, Yi Min Chen, Jing Zhang, Feiyang Chen +6 more
similarity 0.62
Abstract

Interactive clinical agents acquire evidence through patient dialogue and diagnostic examinations, yet their performance also depends on how the interaction environment exposes information, available actions, and examination results. When these conditions are implicit or inconsistently controlled, final-answer accuracy can conflate diagnostic reasoning with the effects of the interaction protocol. We propose the \textbf{E}vidence-\textbf{G}rounded \textbf{I}nteraction \textbf{P}rotocol (EGIP), which enforces role-specific information boundaries, exposes diagnostic actions without revealing their results, retrieves examination results from stored clinical records, and organizes acquired evidence for final decision-making. By separating evidence acquisition from terminal prediction, EGIP enables different decision strategies to operate on the same observations. We evaluate EGIP across two clinical-agent frameworks, five datasets, and six language models. EGIP improves diagnostic accuracy over native baselines across all primary comparisons. A clinician review further shows that the proportion of automatically scored correct responses jointly judged evidence-supported rises from 10.20\% to 36.55\%. These findings support the effectiveness of EGIP as a unified interaction protocol for improving clinical-agent performance through controlled evidence access and acquisition.

0.23

Reliability Stress Tests and Decision-Time Routing for Chest X-ray Vision-Language Models

eess.IV cs.CV ·2026-10-01 ·Xinye Yang, Zhusi Zhong, Scott Collins, Grayson Baird, Xuyu Wang +1 more
publishedbenchmarkcode/data similarity 0.61
Abstract · 6 pages, 4 figures, 5 tables. Accepted version of a workshop paper presented orally at the 2026 IEEE/ACM Conference on Connected Health: App…

Medical vision-language model (VLM) evaluation is sensitive to workflow design, prompting strategy, and benchmark construction, yet most studies treat these factors in isolation. We introduce a reliability stress test for chest X-ray interpretation built on two balanced datasets (a private report-backed set and a curated MIMIC subset). Three medical VLMs (CheXagent, MedGemma-4B, and MedGemma-27B) are evaluated across three prompt styles and two workflows (single-VLM and multi-agent), producing 36 configurations. We show that exact-match accuracy alone can overstate the effectiveness of conservative models that default to "Normal" predictions. Diagnostic reliability also depends heavily on model family and scale: multi-agent reasoning helps some configurations but hurts others. Building on these observations, we propose a decision-time routing framework that selectively escalates to multi-agent inference only when beneficial, improving the cost-quality trade-off over fixed workflows. Our results highlight the need for evaluation protocols that jointly consider prompt sensitivity, failure-mode diversity, and workflow choice before clinical deployment.

0.70

Asclepius: An Adaptive Harness for Long-Horizon Clinical Agents

cs.AI ·2026-09-11 ·Grace Chang Yuan, Xiaoman Zhang, Sung Eun Kim, Luyang Luo, Pranav Rajpurkar
top venue similarity 0.61
Abstract · 9 pages, 4 figures, 11 tables. EMNLP 2026 Findings

LLM agents are predominantly benchmarked on short, single-task trajectories, yet real deployments run for hours under contention, surfacing a different class of failures. We use the Clinical Environment Simulator (CES), in which an agent manages an entire emergency-department shift under continuous time and resource pressure, as a testbed: long-horizon execution failures manifest measurably in a single rollout under structured, multi-dimensional grading. On CES, current agents reach the correct diagnosis in most cases yet fail to deliver complete and timely critical actions, revealing an execution gap. We attribute this gap to three long-horizon failure modes, each operationalized as a per-trace counter: instruction-adherence drift, treatment incompleteness, and a severity-equity gap in timeliness. We then introduce Asclepius, an adaptive agent scaffolding with a self-evolving harness that rewrites the operating manual between shifts from trace-level feedback, an externalized clinical skills library for high-stakes regimen knowledge, and three isolated subagents that partition per-turn decisions across the patient queue. On held-out batches never observed during harness evolution, Asclepius improves critical-action correctness by 22% (p = 0.024) over a strong baseline agent framework while preserving diagnostic accuracy, with consistent gains across five LLM judges from three model families; on the full ten-batch set, improvements reach 25% on critical actions and 13% on timeliness. The three failure modes form a coupled bottleneck: decisive reductions appear only when all three components act together.

0.64

Operation-aware Multimodal Clinical Decision Support System for ICU Discharge Risk Assessment

cs.LG ·2026-11-09 ·Guoqing Zhang, Rafik Hadfi, Takayuki Ito
benchmarkcode/data similarity 0.61
Abstract · 14 pages, 2 figures. Code available at https://github.com/KuoChing-cmd/ClinicalNoteAgent/

Unplanned 30-day intensive care unit (ICU) readmission is a critical benchmark for evaluating healthcare quality. Most predictive models assume readmission risk depends solely on a patient's individual pathophysiological state, ignoring hospital operational context and resource capacity. In practice, discharge decisions are dynamic trade-offs between patient stability and bed turnover pressures. To address this gap, we develop an Operation-aware Multimodal Clinical Decision Support System (CDSS) for ICU discharge risk assessment. The system combines multi-agent collaborative extraction with self-evolving retrieval-augmented generation (RAG) to eliminate template noise from progress notes, while constructing departmental workload indicators alongside admission flow features, continuous vital signs, and sparse medical codes (ICD/DRG). Addressing severe class imbalance (about 10.5% readmissions) and alarm fatigue, we implement data normalization, class reweighting, and decision-threshold calibration. In 20 independent runs across 20,000 ICU stays from MIMIC-III, empirical findings demonstrate that: vital signs alone have limited predictive capacity under real-world class imbalance (PR-AUC of 0.1387 +/- 0.0086); directly concatenating raw text embeddings degrades decision tree performance (XGBoost and LightGBM PR-AUC drop to 0.3893 and 0.4030); whereas an end-to-end multimodal fine-tuning architecture (Transformer E2E FineTune) utilizing layer-wise parameter freezing and differential learning rates reverses text negative transfer, achieving the highest AUROC of 0.8288 +/- 0.0110, PR-AUC of 0.4373 +/- 0.0310, and F1-Score of 0.4757 +/- 0.0196. Operational indicators supply independent risk signals, laying an engineering foundation for high-utility clinical decision support tools.

0.46