CS Paper Radar

Who Benefits from Telemonitoring? Uplift Modelling of a Nationwide Home Blood Pressure Monitoring Programme

Connie Kou

cs.LG ·submitted 2026-11-16 09:01 UTC · v1
unusual

Abstract

Home blood pressure (BP) telemonitoring programmes are being deployed at national scale, yet enrolment resources are finite and the benefit of telemonitoring is unlikely to be uniform across patients. We study the Primary Technology-Enhanced Care for Hypertension (PTEC-HT) programme, a nationwide telemonitoring programme for hypertensive patients in Singapore. Using retrospective data on 16,694 patients registered between August 2020 and May 2024, we first estimate the average treatment effect of the programme on 6-month BP control against a propensity-score-matched non-participant cohort, finding an absolute improvement of 5 percentage points in the rate of BP control (74% vs. 69%, $p = 3\times10^{-12}$), rising to 12 percentage points (63% vs. 50%, $p = 1\times10^{-15}$) among patients with uncontrolled BP at baseline. We then move beyond the average effect and apply uplift modelling to estimate individual treatment effects. Across five uplift learners evaluated with 5-fold cross-validation and Qini curves, an uplift random forest performed best on the full cohort and an S-learner on the uncontrolled-baseline subcohort, although performance bands overlapped across learners. On held-out patients, realised uplift was largest in the top predicted-uplift groups and declined across the ranking. These patients had higher baseline BP grade, more recent hypertension diagnosis and lower medication and diagnosis burden, a profile we offer as hypothesis-generating for targeted enrolment. A handcrafted rule built from these features was competitive with the learned models, outperforming all of them on the uncontrolled-baseline cohort, suggesting that uplift models are useful for discovering heterogeneity that can be distilled into simple enrolment criteria for directing limited care team capacity.

Closest papers

Nearest neighbours by meaning across the whole index.

Context-Augmented, Session-Calibrated Blood Pressure Tracking from Photoplethysmography

cs.AI ·2026-10-21 ·Farouk Ganiyu Adewumi, Timothy Oladunni
similarity 0.55
Abstract

Objective.To distinguish the contributions of acquisition context and photoplethysmography (PPG) to session-calibrated blood pressure (BP) tracking.Approach. The original comparison used three repeats of five-fold participant-level cross-validation in 653 AuroraBP participants, excluding calibration-labelled prediction targets. Matched analyses separated context and PPG and removed elapsed-time terms. Later exploratory follow-ups retained PPG, accelerometer signals and three initial cuff readings. Separate studies evaluated pulse-rate fusion and an intraoperative VitalDB model. Main results.The original wearable-state model achieved participant-level mean absolute errors (MAEs) of 7.697/6.139 mmHg for systolic/diastolic BP (SBP/DBP). Added context reduced MAE by 0.436/0.126 mmHg (97.5% intervals 0.305-0.573/0.053-0.200). In the matched factorial without the external PPG prior, PPG improved on calibration, time and protocol-provided posture/activity by 0.214/0.135 mmHg; removing time left the DBP interval including zero. Standard PPG descriptors contributed, but additional nonlinear/attractor benefit was not established. In a separate follow-up series, a sensor-history ensemble achieved 7.299/5.445 mmHg versus its static-rich reference's 7.363/5.470, small gains of 0.064/0.025 mmHg. Larger DBP errors did not improve uniformly. Quality-weighted fusion reduced pulse-rate MAE from 3.985 to 3.690 beats per minute. VitalDB MAEs remained 15.375/8.833 mmHg despite small PPG gains. Significance. The contribution is a calibrated evaluation framework with explicit controls, reproducible feature-cache-to-results analyses and retained negative findings. The sensor-history gain is exploratory after repeated dataset reuse. Independently estimated wearable states, complete raw-signal reproduction of the supplied richer features, external transfer and clinical adequacy remain unestablished.

0.24

Forecasting cumulative intraoperative hypotension burden: patient-disjoint evaluation of quantile boosting and alert policies

cs.AI ·2026-11-06 ·Yunfan Zhao
benchmark similarity 0.54
Abstract

Background: Binary hypotension forecasts do not describe the depth and duration of future low pressure. Burden forecasts may support graded early warning, but better forecast scores need not yield more useful alerts. Objective: To evaluate conditional quantiles of the next 15-minute mean arterial pressure (MAP) deficit below 65 mmHg and distinguish forecasting performance from episode-warning performance. Methods: Public VitalDB numeric arterial MAP was reduced to 10-second medians without forward filling. Subject-disjoint training, validation and test splits included 70,402, 14,270 and 15,575 labeled windows. We compared climatology, calibrated persistence, last-MAP-only boosting, and direct and residual quantile boosting, with and without additional MAP-history features. Patient-weighted pinball loss and subject-bootstrap intervals evaluated forecasting. Validation selected alert thresholds before a hash-recorded test evaluation. Results: In the test split, the prespecified residual-versus-persistence comparison at the 90th percentile yielded losses of 2.256 and 2.900 mmHg-min, respectively (difference -0.644; 95% interval -0.814 to -0.487). Direct prediction achieved 2.196, and direct prediction with additional MAP features achieved 2.193. Episode-warning results were sensitive to the alert rule and operating threshold. Conclusions: This retrospective benchmark separates burden-forecast skill from warning-policy performance. Findings support further study of direct burden estimation; they do not establish patient benefit, prospective reliability or transportability beyond the source hospital.

0.29

Continuous Cuffless Blood Pressure Estimation Using PPG From Methods to Clinical Translation

cs.ET cs.LG ·2026-11-12 ·Karthika Shalini Potail, Harshitha Manjunatha, Hetvi Kotadia, Tooraj Nikoubin
surveybenchmark similarity 0.53
Abstract

Continuous blood pressure (BP) monitoring could improve hypertension management by capturing changes that intermittent cuff measurements miss. Photoplethysmography (PPG) is widely explored for cuffless BP estimation because optical sensors are inexpensive, wearable, and already present in many consumer and clinical devices. PPG, however, does not measure arterial pressure: BP is inferred from waveform characteristics or pulse timing, which also depend on vascular tone, arterial stiffness, sensor contact, motion, and individual physiology. This survey reviews PPG-based cuffless BP estimation along the full measurement chain, covering physiological mechanisms, waveform features, pulse arrival time (PAT), pulse transit time (PTT), machine-learning methods, datasets, calibration, validation, deployment, bias, and clinical translation. Studies are assessed by the strength of evidence they provide rather than by reported error alone, with particular attention to subject and temporal leakage, dataset imbalance, calibration dependence and drift, motion artifacts, and the gap between benchmark accuracy and reliable real-world measurement. The review finds that progress depends on more than better prediction algorithms. Future work should prioritize physiologically informed models, diverse longitudinal datasets, transparent reporting of calibration requirements and failure rates, stronger evaluation protocols, and studies that demonstrate practical value in clinical care.

0.09

Does Lifestyle Information Improve Hypertension Prediction? A Leakage-Controlled Evaluation on NHANES

cs.LG ·2026-11-14 ·Uriel Benymon
top venuecode/data similarity 0.52
Abstract · Accepted to the Machine Learning for Health (ML4H) 2026 Symposium, Findings Track. Code: https://github.com/urielbenymon/nhanes-lifestyle-hy…

Does readily available lifestyle information improve machine-learning prediction of hypertension beyond routine demographic and anthropometric data? On NHANES 2017-March 2020, five model families (Logistic Regression, Random Forest, Gradient Boosting, Bagged Decision Trees, and XGBoost) were evaluated with fold-local preprocessing and paired bootstrap confidence intervals. Adding physical activity, alcohol use, smoking, and sleep information showed no consistent detectable improvement in held-out discrimination: every paired ROC-AUC confidence interval included zero, including under a stricter measured-blood-pressure phenotype and without synthetic oversampling. Mean cross-model SHAP rank agreement fell from 0.873 to 0.806 over all encoded columns, but this decline was largely attenuated over the 19 baseline columns shared by both arms (0.873 vs. 0.863), and likewise under both robustness checks; attribution-agreement comparisons across feature sets of different sizes therefore require a matched comparison space. In exploratory analysis of untreated adults (measured-blood-pressure outcome), all five models showed small positive differences, two with unadjusted intervals excluding zero, meriting confirmation. These results do not imply that lifestyle factors are clinically unimportant; within this cohort, the evaluated lifestyle block added little incremental discrimination beyond an already-informative baseline.

0.48

PPG-Bench: A Unified Benchmark for PPG Foundation Models

cs.LG ·2026-10-09 ·Arvasu Kulkarni, Mahir Jain, Aditya Ray Mishra, Sandeep Singh, Siddharth Panwar
benchmarkcode/data similarity 0.52
Abstract

Photoplethysmography (PPG) is increasingly recorded by wearable and clinical devices at enormous scale, and a growing number of PPG foundation models (FMs) have been developed to compute reusable representations for various downstream tasks. These models are difficult to compare: different evaluations use different datasets, task definitions, preprocessing, downstream heads, hyperparameter tuning, and baselines. We present PPG-Bench, a unifying open-source benchmark evaluating five public PPG FMs across nine open-access datasets and 26 tasks spanning cardiovascular state estimation, activity, sleep, screening, and identification. We evaluate models under four downstream regimes of increasing adaptability (linear probing, random forests, frozen MLP probes, and end-to-end finetuning), with model-specific hyperparameter optimization and subject-disjoint cross-validation. We also evaluate against three controls: random/constant baseline, a deterministic pulse-rate-variability (PRV) feature set, and a generic time-series FM (MOMENT). Across all 68 task-regime combinations, 35.3% show no meaningful FM advantage over the random/constant baseline, and in 83.8% no PPG-specific FM outperforms both PRV and MOMENT. We also find that added downstream head capacity generally improves performance, but can cause significant degradation if the model is performing at chance/constant level. Current PPG FMs therefore cannot yet claim to provide generalised and transferrable representations of PPG signals, and future evaluation in this field should include checks against simple, non-learned controls. Code for the benchmark and instructions to evaluate more models can be found here - https://github.com/mannas-ai/ppg-bench.

0.31

Calibration-Free Cuffless Blood Pressure Estimation Using Multimodal ECG-PPG Fusion on a Google Pixel Watch

cs.HC ·2026-08-26 ·Jathushan Kaetheeswaran, Boyi Ma, Ali Abedi, Shehroz S. Khan, Milad Lankarany
hot direction similarity 0.51
Abstract

Inadequate blood pressure (BP) monitoring and management outside of clinical settings can worsen major cardiovascular risk factors such as hypertension. While cuff-based devices are commonly used for at-home monitoring, these devices can be inconvenient for daily use due to their sensitivity to body positions, upper-arm constrictions, and limited portability. A promising alternative is emerging in the form of consumer-grade smartwatches, where physiological signals related to cardiac activity can be used to estimate BP non-invasively and continuously across daily living conditions. In this work, we use data collected from a Google Pixel Watch in 40 participants to develop and compare several algorithm approaches for BP estimation. We found that our proposed deep learning model achieved the strongest overall performance, and that fusing smartwatch signals with demographic information improved model generalizability to unseen individuals. However, we also identified that model accuracy was not consistent across participant subgroups, with obese individuals yielding higher estimation errors than others. This study highlights the feasibility of consumer-grade smartwatches as accessible platforms for deploying robust BP estimation algorithms, though clinical reliability will require larger, more diverse populations and additional sensing modalities.

0.22

Change Point--Aware Evaluation and Re-Calibration of PPG-Based Blood Pressure Estimation

eess.SP cs.AIcs.LG ·2026-08-19 ·Yunwon Tae, Minje Park, Gyunho Rho, Dongjoon Yoo, Sunghoon Joo
similarity 0.51
Abstract · MLHC 2026. The first two authors contribute equally

Non-invasive continuous blood pressure (BP) monitoring using photoplethysmography (PPG) is a promising alternative to cuff-based measurements. However, existing PPG-based BP estimation studies predominantly rely on aggregated performance metrics (e.g., mean absolute error) computed over entire evaluation intervals, which can obscure model failures during rapid BP fluctuations and limit clinical relevance. In this work, we propose a fluctuation-aware evaluation framework for PPG-based BP estimation based on time-series change point detection. Instead of heuristic BP thresholding (e.g., $Δ\mathrm{BP} > 10\mathrm{mmHg}$), we identify BP change points by capturing abrupt distributional shifts in BP trajectories and evaluate estimation performance specifically during these fluctuation periods. Our analysis shows that several state-of-the-art models exhibit substantial performance degradation around BP change points, and that periodic test-time calibration is insufficient to handle such dynamic BP variations. To address this limitation, we introduce a targeted re-calibration framework triggered by detected BP change points, improving robustness without modifying model architectures. To the best of our knowledge, this is the first systematic evaluation of PPG-based BP estimation from a BP change point perspective, highlighting the importance of fluctuation-aware evaluation and calibration for real-world continuous BP monitoring.

0.25

A Cardiorespiratory Foundation Model Pretrained on Ten Physiological Signals for Perioperative and Critical Care

cs.LG cs.AI ·2026-11-11 ·Cheol-Hui Lee, Wookyung Kim, Hyeonhoon Lee, Garam Lee, Da-in Eun +1 more
similarity 0.48
Abstract

Arterial, venous, pulmonary artery and intracranial pressures and ventilator waveforms guide decisions in operating rooms and intensive care units, yet foundation models for physiological waveforms have been built almost entirely on the electrocardiogram and photoplethysmogram. We present CARMEN, a single encoder pretrained without labels on ten cardiorespiratory waveforms (2.27 million modality-hours). CARMEN accepts any combination of co-recorded signals from 10 s to 5 min, and a conditioning mechanism, LSCNorm, restores the absolute signal level that normalization removes; without it, the AUROC for intraoperative hypotension fell from 0.894 to 0.780. Across 19 tasks from Korean and US cohorts, the frozen encoder outperformed supervised models on 12 of 15 and three foundation models, one general-purpose and two for biosignals, on 14 to 17 of 19, with none exceeding it on any task. Given the electrocardiogram or photoplethysmogram alone, it matched or exceeded signal-specific foundation models in most comparisons, and it retained its performance when channels were missing.

0.16