Abstract

A clinical AI system can reach a correct final diagnosis through intermediate decisions that could have harmed the patient, and can repair an error while introducing new risks. Most evaluations score final diagnoses; even stepwise benchmarks, which release a case's evidence over time, score whether systems reach the right diagnosis or gather the right information, not whether the decisions a patient passes through are safe. We make patient safety the target of stepwise evaluation. A trajectory audit replays real admissions checkpoint by checkpoint, lets each system decide with only the evidence released so far, and rates every test, treatment and disposition for its potential harm to the patient and, separately, for clinical validity, against the documented final diagnosis and physician-written disease rubrics yet on the evidence available when the decision was made. An LLM judge scores every decision, and a physician reference standard (triple annotation and senior adjudication of a stratified sample) calibrates the rates. An oversight audit branches each trajectory at its first actionable error and measures, on the same branches, whether corrective feedback repairs the error and whether it introduces new harm. Across 300 cases from a hospital cardiology cohort, MIMIC-IV and the public ASCENT benchmark, with up to seven AI systems per source, 55.2% of hospital trajectories reaching an acceptable final diagnosis passed through a decision with moderate or severe potential harm and 24.8% through a clinically unacceptable one; the harm rates were 76.2% on MIMIC-IV and 39.6% on ASCENT. Structured corrections resolved 73.6% of first errors versus 24.8% after bare rejection, yet new potentially unsafe decisions followed 30.2% of corrections versus 19.7% of rejections. A correct final diagnosis does not certify a safe trajectory, and a successful correction does not certify a safe recovery.

Closest papers

Nearest neighbours by meaning across the whole index.

AI Morbidity and Mortality: A Framework for Clinical AI Failure Review

cs.AI cs.HC ·2026-08-31 ·Paulius Mui, Dean F. Sittig, Steve Labkoff, Sanjay Basu
similarity 0.71
Abstract

Clinical artificial intelligence is increasingly embedded in real-world care, yet existing safety mechanisms are poorly suited to reconstructing and learning from individual AI-related errors and near-misses. Aggregate model monitoring can identify performance changes, and traditional patient safety reporting can capture adverse events, but neither is designed to explain how risk emerges across the interaction among AI systems, clinicians, workflows, and institutional controls. We propose AI Morbidity and Mortality (AI M&M), a structured, blameless framework for case-based review of clinical AI failures. The framework combines standardized case intake, evidence preservation and investigator-level reconstruction, tool-in-loop attribution, and corrective-action tracking. Each event is classified across four linked dimensions: Trigger - Mechanism - Clinical Pathway - Corrective Action, separating the condition that exposed a vulnerability from the process that produced risk, its consequence for care, and the remediation assigned. We demonstrate the framework using five illustrative outpatient medication and clinical decision-support cases; two clinician reviewers independently applied all four classification axes and reached agreement across all 20 axis-level classifications. AI M&M is intended to complement, rather than replace, model monitoring, patient safety reporting, and regulatory oversight by converting individual AI-in-workflow failures into actionable institutional learning. Prospective evaluation across institutions, AI systems, and clinical settings is needed.

0.13

Auditing Escalation Reliability in Healthcare LLM Agents: A Perturbation-Controlled Benchmark of Workflow-State Failures

cs.AI cs.CL ·2026-10-15 ·Zihao Zheng, Junyi Yao, Baichuan Li, Jiayu Long
benchmark similarity 0.70
Abstract · 8 pages, 5 figures

Trustworthy biomedical AI requires reliable action selection when evidence is missing, stale, conflicting, or late, not only accurate answers on static inputs. We instantiate an episode-level evaluation protocol as 400 synthetic healthcare workflow episodes: 40 hand-authored semantic seeds across four task classes, two surface parameterizations, and five controlled variants, scored on ANSWER/ASK CLARIFICATION/ABSTAIN/ESCALATE under a pre-declared 5:1 missed-versus-unnecessary escalation cost. Reference actions are single-author study-policy labels, not clinician-adjudicated ground truth. Across five open-weight configurations (1.7B--9.7B), clean decision accuracy reaches 0.97, yet uncertainty-prompted models miss 32--97% of required escalations. The stronger 9.7B configuration narrows but does not remove the gap, falling from 0.97 clean accuracy to 0.78 under conflict. Verbalized confidence is inconsistent (ECE 0.10--0.54; failure AUROC 0.48--0.77), and a development-tuned confidence-only policy yields no utility gain. A transparent workflow-aware controller improves 5:1 utility for every model and reduces missed escalations to 0.12--0.24, at specificity 0.83--0.93. However, a 30-concept lexical stress test reduces each rule detector's recall from 1.00 on trigger phrases to 0.00 on unseen paraphrases, limiting the controller claim to this benchmark. Seed-clustered statistics, ablations, cross-task transfer, raw outputs, and manifests are packaged for audit. The results motivate explicit workflow-state evaluation while showing that apparently effective routing controls need their own generalization tests.

0.46

VFR-Audit: Verdict-Level Reliability for Fairness Audits in Hospital Length-of-Stay Prediction

cs.AI ·2026-08-31 ·Md Jannatul Rakib Joy, Viet Vo, Caslon Chua
top venue similarity 0.67
Abstract · 12 pages, 5 figures. Accepted at the 35th ACM International Conference on Information and Knowledge Management (CIKM 2026)

Fairness audits in clinical Artificial Intelligence convert continuous fairness metrics into binary pass-or-fail verdicts against operational thresholds, where hospital governance boards, payers, and regulators act on the resulting verdicts. Such audits are repeated over time and across hospital sites, thus the same verdict can flip between pass and fail across audits. Existing uncertainty methods such as Bayesian posteriors, bootstrap confidence intervals, and permutation tests address verdict instability only at the continuous-metric level. Converting metric-level uncertainty into a verdict-stability claim remains a manual step that scales poorly across the (model, metric, attribute) cells an audit covers. Existing uncertainty methods also leave open whether bias-mitigation steps, such as reweighing or per-group threshold shifts, yield a stable passing verdict at the cost of model discrimination measured as AUROC or AUPRC.To address this verdict-stability gap, we propose VFR-Audit, a framework built around the Verdict Flip Rate (VFR), a scalar bounded between 0 and 0.5 that measures the probability of verdict reversal under stratified bootstrap resampling. VFR-Audit reports VFR alongside three reliability axes, namely within-cohort resampling stability, audit-size sensitivity, and cross-hospital verdict agreement via Fleiss' kappa.

0.36

Constructing and Evaluating Clinical Reasoning Trajectories for Medical Agent

cs.AI ·2026-09-04 ·Yunqi Zhu, Wen Tang, Jinghao Niu, Wensheng Zhang, Xuebing Yang
similarity 0.66
Abstract

Evaluation of medical artificial intelligence (AI) agents remains predominantly answer-centric, assessing only the correctness of final outputs while overlooking the quality of intermediate reasoning. We propose MedTraj, a framework that treats reasoning trajectories as primary objects for modeling the progressive refinement of clinical evidence toward diagnostic decisions. A reasoning trajectory captures the state transitions among medical concepts---from clinical observations through evidential reasoning to a final conclusion---making the implicit reasoning chain of a medical agent explicit and inspectable. Each trajectory is scored across five quality dimensions: coherence, evidence support, hallucination, completeness, and traceability. Controlled error injection introduces targeted faults into otherwise correct trajectories to establish causal links between specific reasoning failures and measurable quality degradation. Step-level filtering based on marginal contribution identifies which individual reasoning steps drive or undermine reasoning trajectory quality. Quality-weighted reasoning trajectory context feeds these evaluations back into the model at inference time. Experiments across CareQA, PubMedQA, and CECMed demonstrate that reasoning trajectory context consistently improves reasoning coherence. For the severity assessment on the CECMed, quality-weighted reasoning trajectory context nearly doubles the correctness over the zero-shot baseline while cutting the hallucination ratio by 87%. Experiments show that 15.3% of reasoning steps carry most of the quality signal, and that extending chains beyond four steps yields diminishing returns.

0.13

ReplayRCA: Measuring Post-hoc Diagnosis and Live Oversight of Agent Failures by Counterfactual Replay

cs.AI ·2026-10-29 ·Jeremy Canale, Fabien Soulis
benchmarkcode/data similarity 0.65
Abstract · 29 pages, 10 figures, 16 tables. Code: https://github.com/jeremy1392/RCAreplay

When a language-model agent fails a multi-step task, can another model find the decisive mistake and fix it with a single action? We introduce ReplayRCA, a benchmark that scores such diagnoses by intervention rather than by agreement with annotations: the environment is restored to the state preceding the chosen step, the proposed action replaces the agent's own, and the same agent continues. The score, causal repair, is the continuation success rate minus that of a paired placebo that replays the agent's original action through the same mechanism. Two tracks share this protocol: a post-hoc autopsy, where the diagnoser sees the whole failed run and is told that it failed, and live oversight, where a supervisor watches the run unfold and may intervene once, before an irreversible action, without knowing whether the run will fail. Tasks come from OpsWorld, a deterministic, procedurally generated back-office environment with six difficulty levels, the last of which is multimodal (QR codes, handwriting). On 62 calibrated systematic failures, the best of 13 frontier models (Grok 4.7) reaches a causal repair of +51.3 points; the top eight models are statistically indistinguishable, the flagship models of the two largest vendors rank 8th and 12th, and 5 items are repaired by no model. Forcing a strong model to intervene at the last step costs it 17.1 points, so the last-step shortcut of annotation-based attribution benchmarks does not transfer. On 87 runs, the two best live supervisors are statistically tied and one of them is a small open-weight model (DeepSeek V4.1 Flash); the supervisor that is among the best post-hoc diagnosers (GPT-6.1 Sol) is the weakest live one (-14.5 points on the same runs, p = 0.002), so post-hoc diagnostic performance can be a poor proxy for live oversight. The environment and the evaluation code are released at https://github.com/jeremy1392/RCAreplay.

0.47

Complementary Vulnerabilities: Auditing and Governing Clinician-LLM Error Overlap

cs.CY ·2026-10-18 ·Mohsen Amoei, Kathleen Fraser, Dan Poenaru
published similarity 0.65
Abstract · 4 pages main text, 2 figures. Accepted at SMASH 2026, the Symposium on Model Accountability, Sustainability and Healthcare (Mila, Montreal, …

Health systems are deploying large language models (LLMs) into clinical workflows, often on the assumption that a second automated check can only reduce error. But a second reasoner reduces error only insofar as it fails differently from the first. We say that a clinician and a model have complementary vulnerabilities to the extent that they break down through different mechanisms and on different cases. The two reasoners' failure substrates differ: they are embodied and cognitive in the clinician, and statistical and generative in the model - so their weak points need not line up. That divergence is plausible rather than guaranteed, and the independence it creates is fragile, eroding when clinicians defer to the model or the model conforms to the clinician. We therefore propose a predeployment audit in which each site measures error overlap on its own cases. We also propose a governance model with which the site keeps those errors independent over time. Health systems should then judge a clinical artificial intelligence (AI) tool by whether its failures overlap with their clinicians' failures, as well as by its accuracy.

0.37

Auditable Clinical Support with Decision Agents

cs.AI ·2026-11-18 ·Tiancheng Bao, Riga Wu, Jan Wienhold, Sebastian Billig, Patrick Winnersbach +11 more
similarity 0.65
Abstract · 74 pages, 6 main figures, 19 supplementary figures

Clinicians reviewing a diagnostic work-up will ask what was considered at each step and why the assessment changed. Agents powered by free text can reach physician-level diagnostic accuracy, but their written reasoning does not always reflect the factors that went into the decision. Here, we present Decision2Care, a decision agent that works up the acutely ill patient without producing any text. A decision model assigns a probability to each permitted EHR action, and fixed rules carry out the most probable one. We evaluated Decision2Care on the records of 546 emergency admissions across 12 diseases. Decision2Care reached a diagnostic accuracy of 86.5%, compared with 86.1% for the MIRA-v2 agent, and required a median of 2.2 s per work-up, compared with 92-100 s. Each work-up tracked which options Decision2Care was considering at each step. In 10 of the 12 diseases, the differential diagnosis changed most at the test on which the guideline bases the diagnosis. Where Decision2Care was most confident after a single work-up, all but four of its diagnoses were correct (98.5%). We traced each of these four errors back to a single imaging report. Three of them were corrected when that report was removed. The same kind of decision was used to select the treatments, and Decision2Care's drug orders were judged guideline-adherent more often than MIRA-v2's. In emergency patients, its prediction of death was comparable to that of three intensivists on the same cases. In five of the eight intensive care cohorts, it exceeded the best of the three 24-h severity scores within 2-6 h of records. Our results show that decision agents can carry out clinical work-ups while recording the options, probabilities, and execution rules behind each action for audit.

0.30

LLMs Anchor on Chief Complaint and Fail to Integrate Evidence in Sequential Clinical Triage

cs.CL ·2026-09-19 ·Dipankar Srirag, Haokai Zhao, Ashutosh Kumar, Eleanor Hopper, Michael Dalton +4 more
similarity 0.65
Abstract · Under Review

Triage in the emergency department (ED) is a sequential decision process that unfolds turn by turn. Existing evaluations of large language models (LLMs) for triage use completed retrospective records and report performance close to that of physicians. We implement a methodology for evaluating LLMs on sequential triage, the task of predicting a triage acuity label from a growing prefix of a nurse-patient conversation. We evaluate six LLMs at five sequential checkpoints on two corpora: 425 LLM-generated (SIMULATED) and 50 physician-authored (CLINICIAN) conversations, both labelled under the Emergency Severity Index (ESI). Every model, measured by quadratic weighted kappa (QWK), degrades from moderate-to-substantial agreement on completed records to fair-to-moderate agreement at every sequential checkpoint. Controlled perturbations show that the label at every checkpoint is anchored on the chief complaint exchanges, and prompting interventions fail to lift this plateau. Models extract clinically relevant content from later turns, yet the surprisal of the true label rises across the checkpoints. So the model fails to integrate the evidence. Three expert clinicians on the same conversations reach a QWK of 0.887-0.929, while the best model reaches 0.295. Predictions concentrate at ESI-2 and ESI-3, and models agree with each other more than with the ground truth, so ensembling worsens the failure. Deploying LLMs for ED triage based on offline benchmarks alone misses this sequential failure.

0.11