CS Paper Radar

Gaussian Splatoms: Direct Atomic Structure Identification in Electron Tomography

Nalini Singh, Tiffany Chien, Cedric Lim, Arthur R. C. McCray, Colin Ophus, Laura Waller

eess.IV cs.CV ·submitted 2026-11-17 19:47 UTC · v1

Abstract

Atomic electron tomography (AET) computationally reconstructs the 3D atomic structure of materials from a series of 2D projection measurements acquired at different tilt angles. Inspired by Gaussian splatting techniques from computer vision, we introduce an atom-centric parameterization for modeling AET samples. Instead of a conventional volumetric representation with a grid of voxels, we model the sample as a list of atoms, where each atom is a 3D Gaussian characterized by learned location, scale, and amplitude. The Gaussian model is a natural fit for atoms that allows us to easily incorporate prior information grounded in physics; we impose isotropy of atoms, a minimum interatomic distance, and realistic atomic radii. We show in simulation that our method is more robust than volumetric baselines to real-world imaging challenges, including a limited number of measurements and low electron dose. We further show that our method yields a more physically plausible reconstruction of an experimental 23,000 atom iron-platinum nanoparticle than a previously published volumetric reconstruction. Beyond tomography, our representation is a promising tool for any atomic resolution imaging modality (e.g. multislice electron ptychography).

Comment
26 pages, 14 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Real-Time Atomic-Resolution Electron Phase Imaging without Probe Calibration via Ptychography-Supervised Learning

cs.CV cond-mat.mtrl-sci ·2026-09-22 ·H. Yue, C. -C. Chen, C. -N. Hsiao, J. Cheng, Y. Liu +2 more
similarity 0.64
Abstract · Submitted to Advanced Science on June 18, 2026

Atomic-scale phase imaging is central to resolving defects, interfaces, and weakly scattering atoms that govern the behavior of nanoscale materials. Electron ptychography delivers sub-ångström phase sensitivity but remains an offline technique, because its iterative reconstruction is computationally expensive and sensitive to experimental calibration, preventing live use during data acquisition. Here, a ptychography-supervised local inference framework is presented that converts four-dimensional scanning transmission electron microscopy (4D-STEM) into an acquisition-compatible phase-imaging workflow. Physics-constrained reference phase maps reconstructed from a single experimental AuPd dataset serve as teacher labels for a compact model that predicts local phase patches directly from diffraction measurements, without explicit probe input or online iterative optimization. Full-field images are assembled by deterministic overlap stitching. The workflow reaches an online latency of about 0.27 ms per probe position and a throughput of about 20,000 positions per second, an approximately 1,000-fold speed-up over GPU-accelerated ePIE, while preserving atomic-scale lattice contrast and reciprocal-space fidelity. Without fine-tuning, the same model transfers across materials (WS2), defocus conditions (high-entropy alloy nanoparticles), and instruments (hBN at 300 kV). The approach amortizes ptychographic redundancy into a fast, generalizable workflow that enables real-time atomic-scale phase imaging for materials microscopy.

0.14

4D-TEMPO: Differentiable 4D-STEM ptychography via fast Physics Optimizers

cs.CV physics.ins-detcond-mat.mtrl-scimath-ph+1 ·2026-11-18 ·Ramani Duraiswami, Yichao Zhang
similarity 0.64
Abstract · 34 pages: 8-page paper, references, and 23-page supplementary material; 10 figures, 10 tables

Electron ptychography recovers atomic structure from 4D-STEM data: diffraction patterns at multiple positions of a scanned probe. Current codes reconstruct an image and read atoms off it, or fit atoms under an $L_1$ loss; neither gives per-atom uncertainty. We propose 4D-TEMPO, a differentiable physical renderer that fits the atoms, the microscope, and the detector directly to the recorded electron counts under a Poisson likelihood. The output is a list of atoms, each a Gaussian primitive with a 3D position, a thermal width, and a model-conditional error bar from the Fisher information. The Fisher information also conditions the solver, gives the dose (electrons per Å$^2$) each parameter needs, and separates calibration from imaging. On a simulated WSe$_2$ bilayer, starting from the published reconstruction, fitted atoms cut in-plane error by a third (3.2 vs. 4.8 pm) and depth error by 40-61% against its 3D peaks. Depth comes from multiple scattering into the dark field, the faint counts outside the direct beam. The two layers, $10\times$ closer than the depth of field, separate; per-atom depth then follows the layer geometry. When the model is well specified, the bars are calibrated (69% of position coordinates within $1σ$). On experimental WSe$_2$, fitted atoms predict held-out patterns better than the three published codes we test. With free probe modes where atoms are incomplete, the same likelihood predicts best on all three held-out benchmarks, matches every WSe$_2$ baseline in 5 min against up to 20.5 h, and passes torchslice at its released setting 180$\times$ sooner on PrScO$_3$. Per-atom error bars, planned doses, and fast reconstruction point to low-dose, real-time 3D imaging of beam-sensitive and dynamic materials.

0.22

ADT: All-Atom Diffusion Tokenizer for 3D Molecular Structures

cs.LG ·2026-10-16 ·Xuantuo Huang, Encheng Su, Aoran Wang, Pan Tan, Shengyong Xu +4 more
similarity 0.60
Abstract

Discrete structural tokenization provides a promising route to autoregressive 3D molecular generation. Yet, existing tokenizers face a trade-off between compact representation and all-atom reconstruction: atom-level tokens preserve atomic details but produce long sequences, while compact residue-level protein tokens typically omit side-chain geometry. To overcome this limitation, we propose All-atom Diffusion Tokenizer (ADT), which decouples token granularity from reconstruction resolution. ADT uses one structural token per atom for small molecules and one token per protein residue that jointly represents backbone and side-chain geometry. To mitigate geometric distortion introduced by quantization, we leverage the generative capacity of diffusion models to recover fine-grained atomic geometry beyond deterministic decoding from discrete tokens. Extensive experiments across small molecules and proteins demonstrate that ADT achieves strong reconstruction from compact discrete representations while enabling high-quality autoregressive generation of both small molecules and all-atom protein structures. These results establish compact structural tokens as an effective discrete interface for all-atom molecular reconstruction and generation.

0.51

CryoGaussian: Heterogeneous Cryo-EM Reconstruction Made Explicit with Gaussian Splatting

cs.CV ·2026-11-19 ·Ziwen Wang, Jiajun Fan, Chaoran Cheng, Ruihan Guo, Yanru Qu +2 more
similarity 0.59
Abstract · 59 pages, 25 figures, 15 tables

Single-particle cryo-electron microscopy (cryo-EM) determines macromolecular structures from noisy particle images. However, rare, transient compositional states and subtle, continuous conformational variation are difficult to resolve. We present CryoGaussian, a Gaussian splatting method for heterogeneous cryo-EM reconstruction that fits an explicit Gaussian density representation directly to the particle images through a differentiable rasterizer rendering orthographic line integrals modulated by the contrast transfer function. The Gaussians are initialized randomly, with their number derived from the estimated spatial support of the molecular density and their minimum size bounded by the Nyquist frequency of the particle images. To capture the compositional and conformational variation across particle images, we learn particle-image and per-Gaussian latents that jointly modulate the base position, amplitude, and scale of each Gaussian. Each structural state is then reconstructed by fitting the Gaussians conditioned on its inferred latent. On CryoBench, CryoGaussian achieves state-of-the-art reconstruction accuracy for both compositional and conformational heterogeneity. On experimental data, it resolves a rare compositional state of the 50S ribosomal subunit (class C4, 1.3% of particles) with rRNA helix 68 docked in the absence of the central protuberance, and continuous conformational motion of the SF3b and helicase subcomplexes of the pre-catalytic spliceosome. We further optimize the rasterizer for additive cryo-EM projection, reducing training time by 12.8-28.0$\times$.

0.33

Shape-guided Gaussian Splatting for Sparse-View X-ray 3D Reconstruction

cs.CV ·2026-09-09 ·Pranav Poudel, Florence Dell'Aniello Picard, Nairouz Shehata, Frédéric Lavoie, Herve Lombaert
publishedcode/data similarity 0.58
Abstract · Accepted at: Off-Grid: 1st Workshop on Continuous Representations and Grid-Free Methods in Medical Imaging, MICCAI 2026

Sparse-view X-ray 3D reconstruction is essential for reducing radiation exposure, but recovering a density field from a handful of X-ray projections is severely ill-posed. Recently, 3D Gaussian Splatting has achieved state-of-the-art performance in sparse-view reconstruction by representing the volume using explicit, optimized primitives, but it requires dozens of projected views. With fewer views, reconstruction quality degrades severely since the explicit primitives are optimized freely without any anatomical information. Anatomical structures, in contrast, share similar geometry and density across a population. Their variations are bounded within a limited range that statistical shape models can capture. This paper proposes a shape-guided Gaussian splatting framework for sparse-view X-ray 3D reconstructions. Our contribution lies in driving Gaussian positions toward anatomically valid configurations, alongside atlas-based density regularization. Our method ensures anatomically consistent reconstruction and improves PSNR by 2.83 dB over a state-of-the-art Gaussian splatting baseline with as few as 5 views. Code Available: https://github.com/polyshape-lab/ShapeGuidedGaussian

0.46

Spatial-Frequency Learning for Scanning Transmission Electron Microscopy Image Enhancement

cs.CV ·2026-10-27 ·Hesong Li, Ying Fu, Ziqi Wu, Ruiwen Shao, Tao Zhang
top venuedataset similarity 0.58
Abstract · Accepted by IEEE TPAMI

Scanning Transmission Electron Microscopy (STEM) enables the observation of atomic arrangements at sub-angstrom resolution and plays a key role in the discovery and characterization of advanced materials. Raw STEM images are often noisy and blurred due to multiple degradations. Although recent deep learning methods improve STEM images, their performance remains limited under severe degradations. In this work, we propose a spatial-frequency learning framework for STEM image enhancement. Specifically, we design a spatial-frequency fusion network that exploits periodic atomic arrangements in the frequency domain and restores local atomic details in the spatial domain. Spatial- and frequency-domain features are enhanced separately and then fused. We also present a STEM noise calibration method for synthesizing more realistic STEM images. The parameters of scan noise, pointwise noise, and background noise are estimated through statistical analysis and fitting of real STEM images. Using these calibrated parameters, we construct a diverse dataset containing a wider range of atomic arrangements, imaging modes, and degradations. Random masks combine different atomic arrangements to simulate interfaces between multiple materials. Experimental results demonstrate that our method achieves state-of-the-art enhancement performance on synthetic datasets and real images of advanced materials while improving atomic localization accuracy.

0.58

PhyDiCT: Plug-and-Play CT Reconstruction from Sparse X-Rays via Differentiable Rendering and Strong Priors

cs.CV ·2026-10-07 ·Weicheng Dai, Shantanu Ghosh, Kayhan Batmanghelich
top venuecode/data similarity 0.58
Abstract · Accepted at MICCAI 2026; to appear in LNCS 16888

Reconstructing 3D Computed Tomography (CT) images from a few X-ray projections is a highly ill-posed inverse problem due to the loss of volumetric information. We propose PhyDiCT, a training-free framework that integrates a differentiable Physics-based forward model, grounded in the Beer-Lambert law, with a text-conditioned Diffusion as a strong prior to reconstruct 3D lung CT images. We refer to our approach as training-free since the prior model is used without fine-tuning, and our goal is to steer the denoising procedure to generate samples consistent with X-ray observations. We guide the diffusion generation using Split Gibbs sampling to jointly optimize for projection fidelity (reward) and consistency with prior knowledge. Also, we introduce a test-time refinement step that enhances image realism and anatomical coherence. We extensively evaluate our method on publicly available 3D CT datasets using both perceptual and semantic metrics, demonstrating that it surpasses existing plug-and-play diffusion and fully trained reconstruction approaches. Our findings highlight that combining a strong generative prior with the underlying physics of image formation substantially improves reconstruction quality, e.g., 7.5\% improvement on SSIM compared to full training methods. Code will be released at https://github.com/batmanlab/PhyDiCT.

0.44

SciFusion: Physics-Guided Compositional Diffusion for Multimodal 3D Scientific Image Generation

eess.IV cs.LG ·2026-10-21 ·Luoxi Wang, Alessio Quercia, Hanno Scharr, Arya Bangun
similarity 0.57
Abstract

Existing 3D generative approaches are typically developed for individual imaging modalities, requiring substantial modality-specific data and limiting their ability to exploit shared structure across scientific imaging domains. We present SciFusion, a multimodal framework for unified 3D scientific image generation built on a latent diffusion backbone, with two key contributions. First, we introduce a compositional conditioning scheme that factorizes each modality into domain, object, and contrast representations. Sharing these factors across related modalities enables knowledge transfer across heterogeneous imaging domains and allows the factors to be recombined at inference time to synthesize unseen domain-object-contrast compositions in a zero-shot manner. Second, we incorporate domain-specific physics-informed objectives: Fourier spectral consistency for MRI, Radon projection consistency for CT, and multislice diffraction consistency for electron microscopy, to encourage generated samples to respect modality-dependent image formation processes. Extensive experiments across 15 medical and scientific imaging modalities demonstrate that SciFusion improves generation fidelity and cross-domain generalization over modality-specific and flattened multimodal conditioning strategies, while enabling zero-shot synthesis of unseen compositions without training on those target compositions. These results demonstrate that compositional, physics-guided conditioning provides a scalable framework for unified 3D scientific image generation, particularly for emerging modalities where large-scale training data are difficult to obtain.

0.19