CS Paper Radar

Disentangling Monitor Hardware Artifacts and Smoothing Lag for Shift-Robust Intraoperative EEG and Hemodynamic Risk Calibration

Zeyu Jia

cs.LG ·submitted 2026-11-19 09:05 UTC · v1
unusual

Abstract

Commercial intraoperative electroencephalography (EEG) and blood pressure monitors introduce cyclic impedance pulses, smoothing delays, direct-current (DC) drift, and cuff holds that confound risk forecasting and uncertainty calibration. We developed a causal signal-conditioning and shift-robust conformal calibration framework across 5,439 public anesthesia procedures. Streaming filters blank 10.13-min 64-Hz impedance checks, apply unclipped post-notch conditioning, separate 63-s suppression-ratio lag, and distinguish three-channel cuff inflations from dropouts across propofol-remifentanil total intravenous anesthesia (TIVA; N = 3,214), volatile anesthesia (N = 2,046), European endoscopy sedation (N = 171), and DC-coupled surgery (N = 8). De-impedanced cortical tree ensembles were compared against deep sequence models, paired with patient-cluster Subgroup-Covariate-Weighted Conformal Risk Control (CRC) and lag-buffered online Conformal Proportional-Integral-Derivative (PID) tracking. Pre-filter blanking removed 97.90% and 97.60% of false flatline conflicts while preserving 99.23% and 98.96% of deep suppression. On unseen TIVA surgeries (N = 525), cortical features achieved area under the precision-recall curve (AUPRC) 0.3135 (1.94% prevalence) and 0.1627 (0.82% lag-free prevalence), with no detectable difference from deep encoders (p >= 0.36) and no cortical gain for hypotension (0.3432 vs. 0.3437, p = 0.784). Zero-retraining volatile transfer (N = 1,048) showed no detectable difference from an end-tidal gas oracle on lag-free suppression (0.0820 vs. 0.0736, p = 0.472). Subgroup-Covariate-Weighted CRC bounded all 70 TIVA shift cells at <= 4.38% (alpha = 5.0%) in 66.32 ms per 30-s epoch. Causal artifact disentangling and shift-aware conformal calibration support reliable real-time intraoperative risk bounds within explicit physiological observability limits.

Comment
16 pages, 4 figures, 5 tables

Closest papers

Nearest neighbours by meaning across the whole index.

A Cardiorespiratory Foundation Model Pretrained on Ten Physiological Signals for Perioperative and Critical Care

cs.LG cs.AI ·2026-11-11 ·Cheol-Hui Lee, Wookyung Kim, Hyeonhoon Lee, Garam Lee, Da-in Eun +1 more
similarity 0.56
Abstract

Arterial, venous, pulmonary artery and intracranial pressures and ventilator waveforms guide decisions in operating rooms and intensive care units, yet foundation models for physiological waveforms have been built almost entirely on the electrocardiogram and photoplethysmogram. We present CARMEN, a single encoder pretrained without labels on ten cardiorespiratory waveforms (2.27 million modality-hours). CARMEN accepts any combination of co-recorded signals from 10 s to 5 min, and a conditioning mechanism, LSCNorm, restores the absolute signal level that normalization removes; without it, the AUROC for intraoperative hypotension fell from 0.894 to 0.780. Across 19 tasks from Korean and US cohorts, the frozen encoder outperformed supervised models on 12 of 15 and three foundation models, one general-purpose and two for biosignals, on 14 to 17 of 19, with none exceeding it on any task. Given the electrocardiogram or photoplethysmogram alone, it matched or exceeded signal-specific foundation models in most comparisons, and it retained its performance when channels were missing.

0.16

Pharmacokinetic State Space Models for Unbiased Prediction of Haemodynamic Collapse

cs.LG ·2026-09-21 ·Rithin Nagaraj, Sudiksha Chindula, Bhaskarjyoti Das
published similarity 0.56
Abstract · Published in Springer Nature after presenting at the International Conference on AI in Healthcare, London

An Intraoperative Hypotension (IOH) event is a frequent complication during administration of general anaesthesia with serious downstream consequences, yet clinical management remains reactive and not predictive. Existing predictive models, however, ignore drug infusion history as a valuable signal for prediction despite its direct pharmacological relevance. Our model achieves an Area Under the Receiver Operating Characteristic curve (AUROC) of 0.7360 and an Area Under the Precision-Recall Curve (AUPRC) of 0.1794, representing a 2.73-fold lift over the random guessing AUPRC baseline (0.0657), with the removal of propofol and remifentanil effect-site concentrations resulting in a 13.9% AUPRC drop compared to the full model. This is consistent with the hypothesis that pharmacokinetic trajectories encode impending haemodynamic changes before they manifest in the Mean Arterial Pressure (MAP). Additionally, this paper shows that training without lead-gap filtering degraded AUROC by 16.7%, empirically confirming that unfiltered models learn to detect ongoing hypotension rather than predict future events. Finally, a Mamba-based architecture achieves the aforementioned high prediction performance while maintaining a constant memory footprint across a range of sequence lengths, unlike the quadratic VRAM overhead typical of vanilla Transformers, making it the more practical choice for continuous intraoperative deployment.

0.47

Context-Augmented, Session-Calibrated Blood Pressure Tracking from Photoplethysmography

cs.AI ·2026-10-21 ·Farouk Ganiyu Adewumi, Timothy Oladunni
similarity 0.55
Abstract

Objective.To distinguish the contributions of acquisition context and photoplethysmography (PPG) to session-calibrated blood pressure (BP) tracking.Approach. The original comparison used three repeats of five-fold participant-level cross-validation in 653 AuroraBP participants, excluding calibration-labelled prediction targets. Matched analyses separated context and PPG and removed elapsed-time terms. Later exploratory follow-ups retained PPG, accelerometer signals and three initial cuff readings. Separate studies evaluated pulse-rate fusion and an intraoperative VitalDB model. Main results.The original wearable-state model achieved participant-level mean absolute errors (MAEs) of 7.697/6.139 mmHg for systolic/diastolic BP (SBP/DBP). Added context reduced MAE by 0.436/0.126 mmHg (97.5% intervals 0.305-0.573/0.053-0.200). In the matched factorial without the external PPG prior, PPG improved on calibration, time and protocol-provided posture/activity by 0.214/0.135 mmHg; removing time left the DBP interval including zero. Standard PPG descriptors contributed, but additional nonlinear/attractor benefit was not established. In a separate follow-up series, a sensor-history ensemble achieved 7.299/5.445 mmHg versus its static-rich reference's 7.363/5.470, small gains of 0.064/0.025 mmHg. Larger DBP errors did not improve uniformly. Quality-weighted fusion reduced pulse-rate MAE from 3.985 to 3.690 beats per minute. VitalDB MAEs remained 15.375/8.833 mmHg despite small PPG gains. Significance. The contribution is a calibrated evaluation framework with explicit controls, reproducible feature-cache-to-results analyses and retained negative findings. The sensor-history gain is exploratory after repeated dataset reuse. Independently estimated wearable states, complete raw-signal reproduction of the supplied richer features, external transfer and clinical adequacy remain unestablished.

0.24

OOD Detection for EEG-based Machine Learning in High-Risk Environments

cs.LG ·2026-08-18 ·Philipp Bomatter, Henry Gouk
benchmark similarity 0.54
Abstract

Machine learning models for electroencephalography (EEG) analysis show great promise across a wide range of applications, but their deployment in high-risk domains is hindered by their vulnerability to distribution shifts. Encountering out-of-distribution (OOD) data can lead to catastrophic, overconfident predictive failures. While OOD detection methods can mitigate these risks, they remain heavily under-explored for EEG. Moreover, evaluations in the broader literature typically evaluate OOD detection performance in isolation, ignoring their practical impact on downstream applications. To bridge this gap, we introduce a benchmark for EEG OOD detection, evaluate a broad range of methods, and furthermore evaluate their value in two clinical downstream prediction task. Our results disentangle OOD detection and model uncertainty estimation capabilities, which are frequently conflated in the literature, provide actionable insights about the current state of the art for EEG OOD detection and model uncertainty estimation, and demonstrate how complementary methods for both aspects can be combined to form a robust safety net for the deployment of EEG-based machine learning models in real-world applications.

0.31

A Multidimensional Data-Driven Hybrid Transformer Framework for Non-invasive Continuous Blood Pressure Prediction

cs.LG ·2026-08-24 ·Yuexin Ma, Jingqi Hou, Yuxuan Kang, Zhaoying Liu
similarity 0.53
Abstract · 21 pages, 5 figures, 6 tables. Corrected typographical errors in two author email addresses; no changes to the scientific content

Objective. To develop and evaluate a cuffless continuous blood pressure (BP) estimator using temporal physiological and demographic features. We propose a hybrid Transformer framework to estimate diastolic and systolic BP from ECG/PPG-derived feature sequences. Approach. Rather than raw waveforms, the framework models 10-step sequences of six physiological descriptors and two demographic covariates. A Multi-Source Temporal Encoder Module combines Transformer, Kolmogorov-Arnold Network, and XGBoost branches to capture complementary temporal, nonlinear, and tabular information. A Dynamic Conditional Fusion-Decoder applies differential multi-head attention, token-weighted aggregation, and gated residual correction. A robust composite objective jointly optimizes DBP and SBP. Main results. Using the MIMIC-III Waveform and Clinical Databases, the source pool comprised 28,486 waveform segments from 203 subjects, and feature generation retained 53,621 observations from 166 subjects. On 2,431 segment-level held-out test windows, mean error +/- standard deviation was 0.41 +/- 3.74 mmHg for diastolic BP and -1.60 +/- 5.95 mmHg for systolic BP, with 95% limits of agreement of [-6.93, 7.74] and [-13.25, 10.06] mmHg, respectively. The proportions within 10 mmHg were 98.48% and 94.36%. The framework achieved the lowest standard deviations and narrowest limits of agreement among the locally retrained baselines. Significance. The feature-sequence fusion framework improved agreement with reference BP and fell within numerical AAMI and BHS Grade A thresholds on this split. This retrospective analysis is not formal device validation; subject-disjoint and external evaluation remain necessary before clinical use.

0.27

Rolling Day-Wise Mortality Prediction in Critically Ill Patients With AKI on CRRT Utilizing Machine Pressure Waveforms

cs.LG cs.AI ·2026-09-11 ·Shehan Irteza Pranto, Joanna Yang, Joshua Lambert, Stuart L. Goldstein, Lili Chan +4 more
benchmark similarity 0.52
Abstract

Critically ill patients with acute kidney injury (AKI) on continuous renal replacement therapy (CRRT) face high mortality, yet current risk assessment relies primarily on clinical parameters from electronic health records (EHR) and ignores minute-level circuit pressure waveforms generated by CRRT machines that track the extracorporeal circuit's interaction with the patient. Clinicians therefore cannot see deterioration as it develops. Risk is reassessed only when labs are drawn, while this continuous record is discarded because it is contaminated by shared-device records, non-physiological minutes, and sensor artifacts. To make the stream usable, we aligned machine records to charted therapy intervals to prevent cross-patient leakage, removed priming and downtime minutes, tuned denoising on a synthetic spike-injection benchmark, and masked unobserved intervals rather than imputing them. On this cleaned stream, we define a rolling day-wise task and a transformer-based stacked ensemble that late-fuses a window-reduced sequence transformer with classical models using circuit-instability features and clinical EHR variables. In a leak-safe benchmark on the multi-center CRRTnet cohort (976 patients, 4,585 treatment days), the machine-only model had the lowest standalone prognostic value (AUROC 0.625), followed by the EHR-only model (0.717). Integrating EHR and machine streams reached a one-day mortality AUROC of 0.766. SHAP attribution showed that circuit-instability descriptors raised the machine share of the top 15 combined-model features from 3 to 7 (20.0% to 46.7%), highlighting filter pressure, transmembrane pressure (TMP), and access-to-return difference (ARD). To our knowledge, this is the first patient-level mortality prediction incorporating CRRT machine data, turning a discarded bedside stream into a continuous risk signal.

0.15

iEEG Can Help EEG: Improving Clinical Scalp EEG Analysis through Intracranial Priors

cs.LG eess.SPq-bio.NC ·2026-11-16 ·Xianglong Bao, Yi Ding, Zengxiang Li, Nan Liu, Kewen Wang +2 more
top venuecode/data similarity 0.52
Abstract · Accepted at KDD 2027

Scalp electroencephalography (EEG) is a cornerstone of clinical brain monitoring, making the quality of its signal fundamental to downstream tasks and models. However, that signal is heavily contaminated by non-neural interference and blurred by volume conduction. Existing methods operate almost exclusively within the scalp modality, so they inherit the contamination they would need to overcome. In practice, intracranial EEG (iEEG) observes the neural activity with far higher fidelity, yet it is invasive and therefore scarce, and the two modalities are rarely recorded as pairs at scale, share no common channel space, and offer no clean ground truth to directly supervise a mapping. Motivated by the neuronal synchronization mechanism shared by the two modalities, we propose a reprogramming approach that fits a signal-to-signal model on iEEG alone and freezes it as a cross-modal prior. We introduce ReBrain, a framework to transfer an iEEG-learned prior to scalp EEG, which re-expresses any scalp signal through that prior and can be inserted upstream of any downstream model with no pairing or fine-tuning. ReBrain consistently improves host models across recordings from multiple hospitals and across architecture families, and our analysis traces this gain to genuine neural structure carried by iEEG rather than to the architecture itself. This work provides evidence that a scarce clean modality can serve as a transferable prior for an abundant noisy one, offering a general recipe for cross-modal transfer among biosignals. Our code is available at https://github.com/Xianglong-Bao/ReBrain.

0.62

ReMAP: Self-supervised learning to unveil brain representations and vulnerability

cs.LG ·2026-08-22 ·Jade Perdereau, Virginie Loison, Kanssa El Ayeb, Louis Gervais, Melvin Berto Strouc +3 more
similarity 0.52
Abstract

General anesthesia offers a rare opportunity to observe the human brain under a standardized, controlled perturbation. Yet intraoperative electroencephalography (EEG) is almost always reduced to a single proprietary depth index, collapsing a rich trajectory into one number and discarding how a brain moves between states. Here we ask whether the geometry of that trajectory, not merely the depth it reaches, carries clinically meaningful information. Using similarity-based self-supervised learning on raw, two-electrode frontal EEG, with no labels, we place each recording within a low-dimensional space in which anesthetic depth becomes one readable axis while the shape of a patient's path encodes additional structure. We validate the representation across two cohorts and two acquisition systems totaling more than 1,000 patients. Depth of anesthesia is predicted accurately (BIS mean absolute error = 3.2, R2 = 0.82), and in the sparse-montage setting our compact ( 68k parameter) model remains competitive with EEG foundation models orders of magnitude larger (4M-157M parameters), indicating that matching the representation to the recording dominates raw scale. The learned space organizes age along its own gradient, independent from depth, without supervision. The same space also aligns with interpretable anesthetic signatures like frontal alpha, slow-delta, and burst suppression, linking this data-driven representation to established neurophysiology. On an independent cohort with longitudinal follow-up, the geometry of the early trajectory separates 30- month cognitive and mortality outcomes complementary to age (AUROC 0.86). These results suggest that the path a brain traces through anesthesia is a label-efficient correlate of latent vulnerability, motivating prospective validation.

0.25