CS Paper Radar

SEEC: A Large-Scale Dataset and Benchmark for Self-Supervised External-Eye Representation Learning

George R. Nahass, Michelle Fleishaker, Sanjay Ganesh, Sasha Hubschman, R. V. Paul Chan, Chad A. Purnell, Pete Setabutr, Ann Q. Tran, Sathya N. Ravi

cs.CV ·submitted 2026-11-19 16:41 UTC · v1
benchmark

Abstract

External-eye photography captures clinically relevant periocular anatomy at low acquisition cost, yet no large-scale standardized resource exists for evaluating self-supervised external-eye representations. We introduce a 4.35-million-image Standardized External-Eye Corpus (SEEC) derived from fourteen heterogeneous public face datasets, together with a benchmark for external-eye representation learning. For evaluation, we provide held-out evaluation distributions, landmark-annotated anatomical probe sets, and clinical disease-classification experiments spanning ptosis, thyroid eye disease, and craniofacial syndromes. We evaluate representations at two complementary levels: (a) the representation level, by assessing embedding geometry across multiple data distributions, and (b) the functional level, by assessing anatomical recovery, out-of-distribution anatomical transfer, and disease classification. Our models include ResNet-101 and ViT-B encoders pretrained using InfoNCE, VICReg, and LeJEPA objectives and compared with DINOv2 and MAE. Our results indicate that representation-level and functional-level evaluations are dissociable: broader embedding-space utilization does not consistently correspond to anatomical transfer or disease-classification performance, and no single encoder is universally optimal. Domain-specific external-eye encoders outperform DINOv2 and MAE on cross-dataset anatomical transfer despite being pretrained at substantially smaller scale, while external-eye-pretrained ViT models match or outperform these general-purpose baselines on frozen disease-classification probes. We release benchmark code, evaluation scripts, and preprocessing pipelines to reproduce SEEC at https://monkeygobah.github.io/seec-project/

Comment
36 Pages, 10 Figures, 9 Tables

Closest papers

Nearest neighbours by meaning across the whole index.

Representation Learning for 3D Brain Imaging: A Benchmark

cs.CV ·2026-11-04 ·Pierre Falconnier, Robin Trombetta, Nicolas Duchateau, Carole Lartizien
top venuebenchmarkcode/data similarity 0.69
Abstract

Many deep learning architectures for computer vision tasks rely on features extracted by a pre-trained encoder on large databases of natural 2D RGB images. However, the wide domain gap with medical images hampers the direct transfer of optimized deep learning models from computer vision to clinical applications. Recently, self-supervised pre-training and foundation models emerged as promising alternatives to mitigate these limitations. Yet, constructing such models for medical imaging faces critical challenges, including designing and adapting training strategies for large 3D volume datasets, and the need for standardized benchmarks to evaluate feature extraction performance. In this study, we propose an extensive comparison of vision encoders with a focus on 3D brain MRI. First, we consider 8 fully and self-supervised models pretrained on natural images (e.g. ResNet, DINO, CLIP) and 10 backbone architectures trained on medical images, either based on supervised (e.g. RadImageNet) or self-supervised (e.g. BiomedCLIP, SimCLR) tasks. All pre-trained encoders are evaluated on various downstream tasks to assess the representation power of their latent representations, including age and sex prediction as well as disease classification on the ADNI and PPMI datasets. Our study shows that 2D encoders pre-trained on natural images perform the most favorably, even compared to models pre-trained on more than 100k brain MRI volumes, highlighting the need for more suitable and robust methods for representation learning in 3D medical imaging. The source code for this study is publicly available at: https: //github.com/PierreFalconnier/brain-representation-benchmark.

0.50

Learning Where to Focus: Self-Supervised Multi-Scale ViTs for Histopathology

cs.CV ·2026-09-16 ·Anabel Stammer, Valay Bundele, Mehran Hosseinzadeh, Hendrik P. A. Lensch
published similarity 0.69
Abstract · 13 pages, 5 figures, plus supplementary material. Accepted at DAGM GCPR 2026

Pathologists diagnose diseases by first locating suspicious tissue and then examining it at higher magnification, whereas self-supervised vision transformers (ViTs) allocate the same spatial resolution to every image region despite diagnostic evidence being sparse and spanning multiple biological scales. Recent pathology foundation models have substantially improved representation quality by scaling training data and model capacity, but largely retain uniform tokenization. We instead investigate whether pathology representations can be improved by learning where to allocate spatial resolution during self-supervised learning. To this end, we propose CRAFT (Coarse-to-fine Region-Adaptive Feature Tokenization), a DINO-based framework that learns image-dependent mixed-scale representations by using self-supervised attention to selectively refine informative regions while preserving coarse context, together with a symmetric cross-scale regularization objective that encourages complementary coarse and fine representations. Across CAMELYON16, TCGA-Lung subtype classification, and TCGA-LUAD survival prediction, CRAFT consistently outperforms comparable-scale self-supervised methods while requiring lower inference computation. Despite using only a compact 22M parameter backbone trained on comparatively small pathology datasets, CRAFT remains competitive with, and often surpasses, substantially larger pathology foundation models.

0.25

Self-supervised Pre-training Helps Retinal Disease Progression Modelling Most When Data Is Scarce

cs.CV ·2026-09-11 ·Ifeoma Veronica Nwabufo, Julius Gervelmeyer, Sarah Müller, Philipp Berens
similarity 0.68
Abstract

Modelling how a disease progresses over time requires longitudinal imaging cohorts, which are scarce and small, whereas cross-sectional data -- one image per participant -- is abundant. Self-supervised pre-training on such data offers a way to bridge this gap, but it is unclear which strategy best supports progression modelling, or how that answer depends on the amount of labelled longitudinal data. We study this for age-related macular degeneration (AMD), pre-training encoders on the large cross-sectional NAKO cohort and predicting time to late AMD on the longitudinal AREDS dataset. We compare in-house self-supervised encoders against a general-purpose (DINOv2) and a domain-specific (RETFound) foundation model, across contrastive, masked-autoencoding, and self-distillation objectives, under frozen and fine-tuned protocols, and across labelled training sets from 100 to 32,250 examples. Which model performs best depends on how the encoder is used. When the encoder is frozen and labels are few -- the regime typical of longitudinal cohorts -- pre-trained representations reach clinically reasonable discrimination from a few hundred labelled samples, while models trained from scratch do not; this advantage fades under fine-tuning. Transfer is governed by the self-supervision objective rather than corpus scale or domain match, so that an encoder pre-trained on a modest cross-sectional cohort matches or exceeds a far larger in-domain foundation model. Together, these results offer a practical recipe for building progression models where longitudinal data is scarce: a frozen self-supervised encoder with a lightweight survival head.

0.15

Augmentation Strategy for DINO in Glaucoma Classification

cs.CV ·2026-10-23 ·Ashish Kumar Meena, Chandra Sekhar Seelamantula
publishedbenchmarkcode/data similarity 0.66
Abstract · 11 pages, 3 figures. Accepted at the 17th International Workshop on Machine Learning in Medical Imaging (MLMI 2026), held in conjunction wit…

Self-supervised learning (SSL) offers a promising approach to medical image representation learning, yet augmentation strategies of SSL frameworks validated on natural images do not reliably transfer to specialized medical imaging domains. We analyze DINO, a knowledge-distillation based SSL framework, and empirically demonstrate that its default augmentation strategy produces unreliable representations for retinal fundus images, degrading downstream glaucoma classification performance. Guided by the principle that effective cropped views should share minimal redundant information while retaining clinically relevant signal, we redesign DINO's augmentation strategy. Our approach biases the learned representations toward diagnostically critical features rather than low-level image statistics. We evaluate our method for glaucoma classification by training a linear classifier on the frozen representations, achieving strong generalization across seven benchmark datasets. URL for code and weights: https://github.com/ashish-256/task_dino

0.43

Domain-Specific Self-Supervised Representation Learning for Retinal Fundus Classification

cs.CV cs.LG ·2026-08-27 ·Bekzat Nurlanbekova, Fung Fung Ting
similarity 0.66
Abstract

Annotated medical images remain scarce and costly to obtain, which motivates self-supervised learning (SSL). We present a controlled empirical study of two SSL frameworks, SimSiam and SimCLR, for retinal fundus classification, asking whether retina-specific augmentations (Graham's local-mean subtraction and CLAHE) improve representations beyond standard augmentation and grayscale conversion. ResNet-18 backbones are pretrained on 48K unlabeled fundus images and evaluated by linear probing and fine-tuning on EDID (multi-disease) and RetinaMNIST (DR grading). On EDID, grayscale conversion accounts for most of SimSiam's linear-probe gain, and Graham or CLAHE add little on top of it. After fine-tuning, SimSiam with Graham+Gray exceeds an ImageNet-supervised baseline on RetinaMNIST (+3.0 accuracy points) but only matches it on EDID. Retina-specific augmentation therefore helps inconsistently and should be validated per SSL method and task.

0.14

CAMEL: Cross-Architecture Masked Embedding Learning for Ultra-Lightweight Retinal Foundation Models

cs.LG cs.AIcs.CV ·2026-10-29 ·Andre Guarnier De Mitri, Giovani Decico Lucafo, Miller Matheus Lima Anacleto Rocha, Diego Furtado Silva
similarity 0.66
Abstract · 8 pages, 6 figures, pre-print

Recent progress in deep learning has substantially advanced automated grading of ophthalmologic pathologies, supported by large annotated datasets and improved representation learning. However, a significant gap remains between state-of-the-art performance and clinical scalability. In particular, foundation models have reshaped image-based medical screening and diagnosis. These large-scale architectures trained on extensive datasets learn rich, generalizable feature representations that can be adapted to a wide range of downstream tasks. In ophthalmology, RETFound, one of the most relevant foundation models for retinal images, performs strongly across classification, segmentation, and risk prediction tasks. Despite their effectiveness, foundation models are often computationally prohibitive, hindering their deployment in real-world clinical environments where hardware constraints and latency are critical. To bridge this gap, we introduce CAMEL (Cross-Architecture Masked Embedding Learning), a novel cross-architecture distillation framework that uses an asymmetric masking strategy during embedding learning to effectively transfer knowledge from massive teacher foundation models to compact, lightweight student models. Our experimental evaluation across four datasets shows that CAMEL preserves accuracy while drastically reducing computational complexity, enabling lightweight yet highly accurate models suitable for resource-limited clinical settings.

0.21

FOCUS: Benchmarking Retinal Model Generalization from Foundation Vision Encoders to Multimodal LLMs

cs.CV cs.AI ·2026-09-27 ·David Restrepo, Chenwei Wu, Luis Filipe Nakayama, Miguel L. Martins, Stergios Christodoulidis +2 more
top venuebenchmarkdatasetcode/data similarity 0.66
Abstract · Accepted at NeurIPS 2026, Evaluations & Datasets Track. Interactive benchmark dashboard: https://huggingface.co/spaces/dsrestrepo/FOCUS-Reti…

Progress in AI-based retinal image analysis has accelerated with the adoption of foundation models, yet evaluating their real-world reliability remains challenging. Performance reported on a single dataset does not capture how models behave under dataset shift, across clinical definitions, or for different patient subgroups. This limitation is particularly critical in medical imaging, where robustness, calibration, and fairness are essential for safe deployment. We introduce FOCUS (Foundation Ophthalmic Cross-Dataset Understanding under Shift), a cross-dataset benchmark evaluating retinal fundus models across vision-only encoder models (VM), vision-language dual-encoder models (VLM), and multimodal large language models (MLLM). FOCUS harmonizes binary diabetic retinopathy, referable diabetic retinopathy, and glaucomatous optic neuropathy tasks across ten public datasets spanning diverse geographies, acquisition conditions, and label protocols. The benchmark evaluates models through a unified analysis layer that measures ranking performance, calibration, subgroup disparities, and image-quality robustness. We present a large-scale evaluation covering 532 base configurations and 228 MLLM configurations adapted via LoRA fine-tuning. Results show no model family consistently dominates across tasks and datasets: general VM encoders achieve the strongest average ranking performance, medical MLLMs are competitive but variable, and dual-encoder VLMs benefit substantially from lightweight adaptation. Fine-tuning improves in-domain performance but exhibits heterogeneous transfer to external datasets, particularly in calibration. FOCUS provides a practical framework and public benchmark to assess generalization, reliability, and robustness beyond single-dataset leaderboards.

0.52

Where to Predict in Retinal OCT? Anatomy-Guided Target Selection for I-JEPA

cs.CV ·2026-11-12 ·Yunchu Feng, Wai Tak Lau, Kaveri A. Thakoor
published similarity 0.65
Abstract · 18 pages. Accepted as a poster at the GenAI for Health Workshop at NeurIPS 2026 (non-archival)

Self-supervised learning aims to learn meaningful representations from unlabeled data, potentially allowing models to capture subtle anatomical variations across patients and reduce the amount of labeled data needed. Image-based Joint-Embedding Predictive Architecture (I-JEPA) learns by predicting target-region representations from visible context rather than reconstructing pixels. However, its uniform target placement does not account for the anatomical structure of retinal OCT, where retinal tissue occupies only part of each B-scan. We investigate anatomy-guided target selection using image intensity and predicted retinal segmentation while retaining the I-JEPA architecture and latent prediction objective. We compare anatomy-guided rectangular targets, anatomy-shaped targets and coverage-constrained placement with uniform masking, and evaluate the learned representations using linear probing for glaucoma classification on FairVision. We found that rectangular targets guided by image intensity achieved the highest linear-probe AUC in our comparisons. We show that anatomically meaningful target selection is promising for retinal OCT representation learning, while greater anatomical specificity did not consistently improve performance.

0.35