Sensor-Free Shockable Rhythm Classification During CPR Using the Existing ECG Channel of Public-Access Automated External Defibrillators

Jaechan Lim, David Hicks, Matt Valentine, Ki H. Chon

eess.SP ·submitted 2026-11-19 16:45 UTC · v1

Abstract

Automated external defibrillators (AEDs) are public-access devices intended for use by lay rescuers, yet they must pause chest compressions to analyze the rhythm because compressions corrupt the electrocardiogram (ECG). Removing this pause requires a method that uses the hardware already present in the device, fits within its processor budget, and meets the rhythm-recognition performance required for defibrillator approval. Existing approaches rely either on an auxiliary sensor, which entails a hardware redesign, or on an additional network that reconstructs the ECG before classification. This work classifies the compression-contaminated ECG directly, using only the existing ECG channel of the AED. A cascade of three compact convolutional networks trained with different class ratios verifies each decision with a second network biased toward the proposed outcome; disagreement yields an indeterminate outcome. Evaluated on an independent manufacturer-provided cohort of 464 subjects over 15 train-validation partitions, the cascade satisfies both adjudicable American Heart Association criteria under all six noise conditions at an eight-second window and a signal-to-artifact ratio of 0 dB, with sinus-rhythm specificity of 99.20-99.43% and other non-shockable specificity of 95.48-96.20%, leaving only 1.07-1.48% of segments indeterminate. The criteria are not met at -3 dB. Single networks matched in parameter count and inference cost do not reproduce this performance. Each decision evaluates two of the three networks and requires 6.68 ms on a single thread of a general-purpose processor, and eight-bit quantization reduces the model to 1.45 MiB without changing any compliance verdict. Thus, rhythm analysis during ongoing CPR can be implemented with the ECG hardware already present in public-access AEDs, without auxiliary sensing hardware, subject to validation on the target device.

Closest papers

Nearest neighbours by meaning across the whole index.

ECGWmark: Deep Watermarking of Electrocardiogram Signals With Error-Correcting Codes

eess.SP cs.CRcs.CV ·2026-10-09 ·Kuan-Yu Chen, Kuan-Chen Wang, Yu Tsao, Jian-Jiun Ding
similarity 0.67
Abstract · 10 pages, 3 figures, 4 tables

Wearable electrocardiogram (ECG) recordings pass through multiple networks and systems before automated interpretation, making patient metadata vulnerable to loss. Digital watermarking embeds this metadata directly into the signal. However, conventional ECG watermarking methods fail under temporal desynchronization, and waveform similarity does not guarantee downstream diagnostic preservation. This article presents ECGWmark, a deep watermarking framework for single-lead ECG. A fully convolutional generator embeds the payload without signal quantization, a detector decodes the message frame by frame and verifies watermark presence, and a frozen arrhythmia classifier penalizes changes that would alter diagnostic predictions. To bridge the gap between bit accuracy and whole-message recovery, payloads are protected by extended Hamming codes, validation-selected interleaving, and soft-decision decoding. On the MIT-BIH Arrhythmia Database, ECGWmark maintains over 90\% bit accuracy under time shifts of 10 to 50 samples, where transform baselines fall to chance level. With the coding layer, the protected 16-bit payload achieves 99.86\% exact recovery on clean segments and sustains over 90\% recovery under time shifts, 10\% sample deletion, and 10\% packet loss. Inter-patient evaluation confirms improved ventricular-beat sensitivity with preserved macro-F1. Requiring only 0.56 million parameters and about 15~ms per segment on a desktop CPU, ECGWmark highlights the need to assess physiological watermarking through whole-message recovery and diagnostic consistency.

0.18

BeatFlow-ECG: Rectified Flow for ECG Reconstruction from Indirect Wearable Signals

cs.LG eess.SP ·2026-10-06 ·Mohamed Kamel, Sahar Selim, Walaa Medhat, Tamer Nadeem
similarity 0.66
Abstract · 27 pages. Preprint. Under review

Continuous cardiac monitoring outside clinical settings requires signals that are both informative and practical to collect during daily life. Electrocardiography (ECG) provides rich information about cardiac rhythm and waveform morphology, while wearable photoplethysmography (PPG) is easier to acquire continuously but is only an indirect cardiovascular measurement and is highly sensitive to motion. We present BeatFlow-ECG, a conditional rectified-flow model for reconstructing single-channel ECG from synchronized PPG and inertial measurements. BeatFlow-ECG models reconstruction as conditional transport from noise to ECG using a convolutional encoder-decoder with a transformer bottleneck and explicit flow-time conditioning. Motion information is incorporated through IMU-derived conditioning features, motion-dependent loss weighting, and an easy-to-hard training curriculum. We evaluate the model under leave-one-subject-out protocols on PPG-DaLiA and WESAD. BeatFlow-ECG achieves the best results among the evaluated deterministic, adversarial, and diffusion-based baselines across all reported waveform and beat-timing metrics, with Pearson correlations of 0.983 and 0.986 and R-peak F1 scores of 0.946 and 0.955, respectively. Compared with Conditional DDPM-1D, L1 error decreases from 0.085 to 0.062 on PPG-DaLiA and from 0.074 to 0.055 on WESAD. Additional analyses on PPG-DaLiA show higher correlation in fixed R-peak-relative waveform regions and lower reconstruction error across low-, medium-, and high-motion subsets.

0.25

Deep learning for non-transvenous ICD screening: tailored neural network architectures, extended experiments, and explainability

cs.LG ·2026-10-27 ·Bartosz Morawski, Samuel J. Ward, Alex Touze, Lin-Thiri Toon, Paul R. Roberts +2 more
benchmarkhot direction similarity 0.66
Abstract

This paper studies two non-transvenous implantable cardioverter-defibrillators (ICDs), namely the Subcutaneous ICD (S-ICD) and the Extravascular ICD (EV-ICD). Both avoid the complications of transvenous leads but are prone to oversensing, which can trigger inappropriate shocks associated with increased mortality. Oversensing risk is predicted by the ratio of T- or P-wave amplitude to R-wave amplitude (T:R, P:R), and these ratios vary over a 24-hour period. Yet S-ICD screening uses a single 10-second electrocardiogram (ECG) segment, and the EV-ICD has no formal screening protocol whatsoever. We present a 24-hour ambulatory screening framework for both devices which includes the first T:R analysis in an EV-ICD cohort and the first full evaluation of P:R prediction. We introduce AmpRatioNet, a family of 1D convolutional neural network architectures operating directly on the ECG signal, and benchmark it against the best existing approach - based on 2D phase space reconstruction images. Evaluation uses 4,605 clinician-annotated 10-second segments from 89 patients, with patient-level 10-fold cross-validation and bootstrap confidence intervals. AmpRatioNet-SE demonstrates superior performance on every metric in each setting with no device- or ratio-specific redesign. An explainability analysis against interpretable classical peak labelling algorithms shows that AmpRatioNet-SE's increase in error on oversensing-prone segments is up to 14 times smaller than theirs. Segment-level predictions are aggregated into a 24-hour timeline, extending S-ICD screening beyond 10 seconds and offering a plausible EV-ICD screening pathway pending device-level validation.

0.26

A Cardiorespiratory Foundation Model Pretrained on Ten Physiological Signals for Perioperative and Critical Care

cs.LG cs.AI ·2026-11-11 ·Cheol-Hui Lee, Wookyung Kim, Hyeonhoon Lee, Garam Lee, Da-in Eun +1 more
similarity 0.65
Abstract

Arterial, venous, pulmonary artery and intracranial pressures and ventilator waveforms guide decisions in operating rooms and intensive care units, yet foundation models for physiological waveforms have been built almost entirely on the electrocardiogram and photoplethysmogram. We present CARMEN, a single encoder pretrained without labels on ten cardiorespiratory waveforms (2.27 million modality-hours). CARMEN accepts any combination of co-recorded signals from 10 s to 5 min, and a conditioning mechanism, LSCNorm, restores the absolute signal level that normalization removes; without it, the AUROC for intraoperative hypotension fell from 0.894 to 0.780. Across 19 tasks from Korean and US cohorts, the frozen encoder outperformed supervised models on 12 of 15 and three foundation models, one general-purpose and two for biosignals, on 14 to 17 of 19, with none exceeding it on any task. Given the electrocardiogram or photoplethysmogram alone, it matched or exceeded signal-specific foundation models in most comparisons, and it retained its performance when channels were missing.

0.16

Beat-Synchronous Tokenization for ECG Transformers

cs.LG eess.SP ·2026-08-31 ·Ahmed Sameh, Nolan Wilson, Max Enderlein, Yogatheesan Varatharajah
published similarity 0.64
Abstract · 6 pages, 1 figure, 3 tables. Accepted at the 2026 IEEE International Workshop on Machine Learning for Signal Processing (MLSP 2026)

Transformer-based electrocardiogram (ECG) models commonly tokenize waveforms into fixed temporal patches. Though convenient, fixed patching can split heartbeat structures across token boundaries. We study beat-synchronous tokenization as a physiologically grounded alternative, comparing fixed patches with three beat-aligned strategies: resampled beats, adaptive pooled beats, and resampled beats augmented with R--R interval information. Experiments span two settings: 10-second 12-lead diagnostic classification on PTB-XL after MIMIC-IV-ECG masked pretraining, and 60-second single-lead rhythm classification on Icentia11k after patient-level contrastive pretraining. On PTB-XL, resampled beat tokens achieve the highest mean macro Area Under the ROC Curve (AUROC; 0.8945) and nearly match the best fixed-patch macro Area Under the Precision-Recall Curve (AUPRC; 0.7414), reducing average sequence length from 100 to 11.2 tokens. On Icentia11k, beat-synchronous tokenizers obtain comparable AUPRC to fixed patching with better stability across runs. These results suggest morphology-preserving beat tokenization is a compact, competitive alternative to fixed temporal patching.

0.20

Few-Shot Prototype Head Adaptation for On-Device ECG Personalization on PSoC~6

cs.LG cs.AI ·2026-10-05 ·Guilherme Silva, Pedro Silva, Gladston Moreira, Eduardo Luz
published similarity 0.63
Abstract

Wearable and bedside electrocardiogram (ECG) monitors must adapt to patient-specific morphology to maintain arrhythmia detection accuracy across users, yet personalization is typically performed offline and cannot account for individual physiology, electrode placement, or recording drift. On-device adaptation by backpropagation is expensive for microcontroller-class medical devices because it requires an optimizer state, repeated backward passes through convolutional layers, and labeled arrhythmic beats that may not be available at deployment time. This letter proposes prototype-only head adaptation as a compact personalization primitive for TinyML ECG systems. A one-dimensional convolutional neural network (1-D CNN; 1,314 parameters and 72.6k multiply-accumulate operations per beat) is trained offline on the MIT-BIH Arrhythmia Database under an inter-patient protocol, frozen as a feature extractor, and exported to a PSoC 6 microcontroller. Patient-specific adaptation then reduces to computing closed-form class means in a 32-dimensional embedding space, requiring no convolutional backward pass, no iterative optimization, and only one forward pass per support beat. Prototype adaptation improves inter-patient macro-F1 from 0.635/0.639/0.646 to 0.731/0.771/0.797 at 1/5/10-shot, outperforming linear stochastic-gradient-descent (SGD) head fine-tuning at every shot count for the target tiny backbone. On-device replay over 18 one-shot episodes on a PSoC 6 Cortex-M4F matches the host macro-F1 for the prototype head (0.798), with 11.39 ms per beat, 5.2 KB flash, and 22.2 KB SRAM. A restricted variant that updates only the normal-class prototype from passively buffered sinus beats yields a consistent +0.05 macro-F1 gain, reducing the annotation burden during initial

0.37

TransECG-SSL: Hybrid Self-Supervised Representation Learning for ECG Arrhythmia Classification

cs.LG ·2026-10-26 ·Ahtisham Ayyub, Fasih Haider, Muhammad Rehan Usman, Saturnino Luz, Christos Politis +1 more
similarity 0.63
Abstract · Submitted to IEEE Journal of Biomedical and Health Informatics

Cross-dataset generalisation remains a major challenge for automated electrocardiogram (ECG) arrhythmia classification because of differences in patient populations, acquisition protocols, annotation practices, and class distributions. Learning representations that remain informative across independent datasets could reduce reliance on dataset-specific labelled data. We propose TransECG-SSL, a self-supervised framework for transferable heartbeat representation learning from unlabelled ECG data. A Transformer encoder is pretrained using a hybrid objective combining masked signal reconstruction and contrastive learning, then frozen and evaluated by linear probing under patient-disjoint evaluation. Experiments across three public ECG databases and seven source--target settings show that Hybrid SSL consistently outperforms randomly initialised Transformers and achieves higher balanced accuracy than architecture-matched source-supervised pretraining. Reconstruction-only SSL remains competitive with Hybrid SSL, whereas contrastive-only pretraining performs substantially worse, highlighting the importance of masked reconstruction for transferability. Cross-dataset transfer nevertheless reduces balanced accuracy relative to target-specific self-supervised pretraining, while minority arrhythmia classes remain challenging under severe class imbalance. These findings demonstrate the potential of label-efficient self-supervised learning for cross-dataset ECG representation transfer while highlighting persistent limitations from domain shift and class imbalance.

0.24

Test-Time Adaptation for ECG Classification via SQI-Gated Self-Training and Beat-Rhythm Consistency

cs.LG ·2026-08-24 ·Wenhan Jiang, Zhipeng Deng, Jiale Zhou, Haolin Wang, Yafei Ou +1 more
top venue similarity 0.63
Abstract · Accepted at MICCAI 2026

Deep learning models for electrocardiogram (ECG) classification often suffer from significant performance degradation when deployed in unseen domains due to shifts in acquisition devices and patient populations. Test-time adaptation (TTA) offers a practical solution by adapting models using only unlabeled data at inference time. However, existing TTA methods often underperform on ECG tasks, since naive online updates ignore the hierarchical beat-rhythm structure of cardiac cycles and are vulnerable to signal artifacts, which leads to unstable adaptation and model drift. We propose BeatRhythm-TTA, an ECG-tailored TTA framework that explicitly accounts for ECG's noisy observations and structured beat-rhythm semantics under domain shift. First, to handle pervasive ECG artifacts, we introduce a Signal Quality Index (SQI)-gated adaptation scheme that selectively filters out low-quality signals to prevent harmful updates. Second, to leverage ECG's beat-rhythm semantics, we enforce dual-level consistency so the model preserves beat morphology and rhythm dynamics while adapting to shifted acquisition conditions. Extensive experiments on multi-label ECG diagnosis across three adaptation protocols, using PTB-XL as the source domain and CPSC2018/Georgia as two target domains, demonstrate the effectiveness of our method, yielding an average +2.70% relative improvement in Macro-F1 over the best competing method.

0.55