CS Paper Radar

Duplicate- and Patient-Overlap Leakage in Brain MRI Tumor Classification: A Multi-Model Evaluation

Xin Li, Samson Oluwadare

eess.IV cs.CV ·submitted 2026-11-20 00:39 UTC · v1
benchmark

Abstract

Background. Repeated MRI images and distinct slices from the same patient can both compromise evaluation of brain tumor classifiers. Objective. We audited image duplication and examined how patient overlap relates to discrimination, probability error and model ranking. Methods. The Cheng/Figshare dataset contains 3,064 contrast-enhanced T1 MRI slices, three tumor classes and 233 recorded patient IDs. The dataset author advised treating the IDs as individuals, but original DICOM records were unavailable for verification. Four CNN architectures were trained under image-level and recorded-ID-disjoint protocols with five folds matched on size and class counts (40 original runs). A patient-cluster bootstrap quantified uncertainty. The extension added 60 split-seed runs, 40 training-seed runs and 72 fixed-test sibling-exposure runs with class-matched other-patient controls. Results. We found no exact duplicate images and little evidence of cross-patient near-duplicates among screened pairs. Image-level minus recorded-ID-disjoint balanced accuracy ranged from +0.0318 to +0.0462 across models. Expected calibration error and multiclass Brier scores were lower on the image-level evaluation sample. The balanced-accuracy difference persisted across new seeds for ResNet50 and DenseNet121, but their original ranking reversal did not replicate. Only ResNet50 in fold 2 passed Holm correction in the five-test exposure family. All 16 correlated exploratory subgroup estimates were positive, with no consistent dose-response. Conclusions. Patient overlap was associated with higher apparent performance on this benchmark. Fixed-test comparisons could not isolate patient identity from shared anatomy or acquisition characteristics. No independent external clinical validation was performed.

Comment
14 pages, 6 figures, 2 table

Closest papers

Nearest neighbours by meaning across the whole index.

Benchmarking CNNs, Vision Transformers, and Foundation Models for Explainable Brain Tumor MRI Classification: Calibration, Decision Analysis, and External Validation

cs.CV ·2026-11-09 ·Akwasi Asare
similarity 0.75
Abstract · Under review at Scientific Report Journal, Springer

Deep learning models for brain tumor MRI classification are usually compared by accuracy alone, on public datasets whose independence is rarely checked. We benchmarked six architectures: two convolutional networks (EfficientNetV2-M and ConvNeXt-V2-Tiny), two vision transformers (Swin-V2-S and ViT-L/16), and two foundation models (DINOv2-L and MedSigLIP-448), for four-class classification of 7,216 public MRI images. We assessed accuracy, calibration, explainability, ensembles, and decision curves, with every fitted quantity estimated on validation data only. Pixel-verified duplicate screening showed that 36% of the test images had a near-duplicate in the training data. Test accuracy ranged from 94.5% to 95.6%, with no pairwise difference after Holm correction, and fell to 90.3% to 91.7% on the 773 test images free of duplicates and shared patients. Ensembles did not outperform the best single model. Attribution maps passed a model-randomization test but localized expert-annotated tumors poorly. On 1,675 external BDNeuro-MRI images that did not duplicate the training data, accuracy ranged from 77.6% (MedSigLIP-448) to 95.0% (ViT-L/16), and 12 of 15 pairwise differences were significant. Internal accuracy on this public collection therefore did not distinguish the architectures, whereas the duplicate-filtered external test did.

0.15

Identity-Duplication Auditing in National-Scale Neuroimaging Repositories

cs.CV ·2026-10-07 ·Jiheng Li, Michael E. Kim, Trent M. Schwartz, Yuhan Cui, Gaurav Rudravaram +13 more
code/data similarity 0.70
Abstract · Code and documentation: https://github.com/MASILab/HAPPEN

National-scale magnetic resonance imaging (MRI) repositories increasingly integrate data from different studies and institutions. However, subject identifiers assigned to study participants are typically specific to individual datasets, so the same person may appear under different identifiers when these datasets are aggregated, a problem we define as identity duplication. Such duplication can create leakage between training and test data and inflate apparent performance in downstream biomedical studies. Existing methods do not provide an end-to-end, image-based workflow to address this problem. In this work, we present HAPPEN, a human-in-the-loop pipeline for auditing identity duplication in T1-weighted brain MRI repositories. It combines SHA-256 fingerprinting for exact-duplicate detection with embeddings learned through supervised contrastive learning to retrieve near-duplicate candidates: pairs of non-identical scans that may originate from the same person. Retrieved pairs are reviewed as candidates in a locally hosted interface rather than automatically classified as duplicates. We deployed the workflow in a national-scale aggregated repository containing 95,129 scans and assessed end-to-end recovery of 54 pairs of subject records identified as duplicates using genome-wide genotype data. Transferability was assessed by locally deploying the same workflow on 22,386 scans at an independent institution without model retraining or image transfer. Deployment in the study repository identified 1,316 exact-duplicate scan groups and 1,275 near-duplicate groups of subject records supported by human review. Of these groups, 56% and 82%, respectively, crossed dataset boundaries. All 54 genetic-reference pairs were recovered. The external team independently completed the full workflow using a locally selected operating threshold and review standard.

0.32

Scores That Hold, Benchmarks That Leak: Measuring Dataset Contamination in Public Brain-Tumor MRI Classification

cs.CV cs.AI ·2026-09-30 ·Bhanu Prakash Vangala, Sowmya Guda, Latha Peddi, Navya Vangala
benchmark similarity 0.65
Abstract

Automated classification of brain tumors from MRI is a heavily published application of deep learning in medical imaging, with reported accuracies on public benchmarks routinely exceeding 98%. However, accuracy does not capture a critical dimension of benchmark quality: dataset integrity, defined as the independence of test from training data at the image, patient, and acquisition-source levels. We introduce a three-layer contamination framework comprising duplicate, patient, and source-label leakage to assess the public corpora on which this literature rests. We audit the three most widely used corpora against a chest-radiograph negative control and quantify each layer's effect on measured performance across nine architectures and three evaluation conditions. Contamination is severe at every layer: 28.8% of the dominant corpus's official test split has a near-twin in its own training split, a second corpus leaks 22.3% of its test images byte-identically, 95.5% of traceable test images share a patient with training, and file-header features containing no anatomy separate tumor from no-tumor at 0.959 balanced accuracy, at parity with fine-tuned ResNet backbones. The unexpected result is that removing every identified leaked test image leaves balanced accuracy essentially unchanged: stable performance after deduplication does not establish benchmark integrity. Our findings establish dataset integrity as a distinct, measurable axis of benchmark quality that a stable leaderboard cannot certify. For biomedical research, reported accuracy on these corpora alone does not establish that a model has learned to recognize tumors rather than exploit dataset-specific cues. We release the contaminated-file lists, recovered patient identifiers, and deduplicated splits.

0.43

Model validation in machine learning: A scenario-based guide from hold-out splits to nested group cross-validation in biomedical and applied research

cs.LG cs.AI ·2026-10-01 ·Mehmet Baygin, Sengul Dogan, Turker Tuncer
similarity 0.64
Abstract · Tutorial with eight controlled scenarios; includes MATLAB and Python/scikit-learn code listings

Model validation estimates the performance of a complete learning procedure on new data. However, an invalid split can produce an optimistic and stable result. This tutorial reviews hold-out validation, train/validation/test designs, repeated random subsampling, k-fold and repeated stratified cross-validation, leave-one-out and leave-p-out schemes, group-aware validation, and nested group cross-validation. General machine-learning principles are linked to EEG epochs, paired-eye OCT images, repeated clinical measurements, and multicenter data. Eight controlled scenarios compare flawed and leakage-safe designs: seven use locked confusion matrices with auditable metrics, and one uses a reproducible repeated-study simulation. The scenarios cover global feature selection, normalization leakage, dependent records, center mixing, repeated test-set use, and estimator instability. Bias, variance, metric aggregation, uncertainty, and computational cost are also examined. A data-size matrix, a decision tree, and reporting checklists are provided. Reproducible MATLAB templates and scikit-learn counterparts are included. The results show that no validation method is universally best. The independent unit must match the intended deployment target. Every data-dependent operation must also exclude the observations used for performance estimation.

0.22

On the Role of MRI Sequences in Cross-Dataset Generalization for Brain Tumor Segmentation

cs.CV ·2026-08-30 ·Henrique Zan Grande, João G. Pitol, Lucas B. Schuck, Rafael V. Serenato, Rayson Laroca +1 more
publishedcode/data similarity 0.62
Abstract · Accepted for presentation at the 2026 Conference on Graphics, Patterns and Images (SIBGRAPI)

Brain tumor segmentation in magnetic resonance imaging (MRI) is a critical task for diagnosis and treatment planning. Despite the success of deep learning architectures such as U-Net and its variants, performance degradation across datasets remains a major challenge, particularly under domain shift and limited annotated data. To address this issue, this study systematically evaluates how individual MRI sequences influence model robustness across two well-known datasets. A ResUNet-based framework is employed, where each modality is trained independently to isolate its effect under a controlled cross-dataset evaluation protocol with tumor size stratification, without target-domain training, or with limited domain adaptation. Results show that the T2f/FLAIR sequence achieves the best cross-dataset performance, with Dice scores exceeding 75%. It consistently outperforms other modalities across most tumor size ranges, while multi-sequence training further improves performance. Additionally, even limited target-domain adaptation yields rapid initial gains, reducing the need for extensive annotations and costly retraining. Our source code is publicly available at https://github.com/henrique-zan/brain_tumor_segmentation/.

0.39

Towards Trustworthy AI for Glioma Diagnosis: A Task-Aware Evaluation of Uncertainty Quantification

cs.CV cs.AI ·2026-09-30 ·Gonzalo Esteban Mosquera Rojas, Sebastian R. van der Voort, Carolin M. Pirkl, Sandeep Kaushik, Marion Smits +1 more
top venue similarity 0.62
Abstract · Accepted for publication at the Journal of Machine Learning for Biomedical Imaging (MELBA) https://melba-journal.org/2026:033

Uncertainty Quantification (UQ) is a key requirement for trustworthy AI in high-stakes medical image analysis. In this work, we evaluate UQ in a multi-task Deep Learning framework for MRI-based glioma diagnosis that performs tumor segmentation and predicts IDH mutation status, 1p/19q co-deletion status, and tumor grade. Monte Carlo Dropout (MCD) is used for a detailed task-aware analysis of predictive, aleatoric, and epistemic uncertainty. We assess MC sample convergence, calibration, error detection, selective prediction, associations with segmentation performance, and the effect of voxel-wise uncertainty aggregation on case-level reliability. We also compare MCD with Deep Ensembles (DE) and Monte Carlo Deep Ensembles (MCDE), examine interactions between segmentation quality and classification, and evaluate a composite trust score integrating segmentation and classification uncertainty. Across tasks, uncertainty estimates supported meaningful error detection, while calibration depended on the dropout rate, with moderate rates yielding the most reliable probabilities. Uncertainty decomposition provided task-dependent interpretability but did not consistently improve error detection over predictive uncertainty alone. DE and MCDE showed comparable operational utility, with no method consistently dominating across tasks and metrics. The composite trust score did not consistently outperform classification uncertainty for selective prediction. Overall, our results provide a task-aware evaluation strategy and practical guidance for the development of trustworthy AI for glioma diagnosis.

0.41

Evaluating the Safety of Deep Learning-Based Brain MRI Reconstruction

eess.IV cs.CV ·2026-08-28 ·Dat Tat Mai, Thai Viet Pham, Thu Nguyen Thi Dang, James Jin Kang
similarity 0.61
Abstract

Objective: Deep learning accelerates brain MRI four- to tenfold, but models can erase lesions or synthesize false tissue - failures pixel-averaged metrics like PSNR and SSIM miss. We review whether current evaluation practices detect this blind spot. Methods: Following PRISMA 2020, we searched seven databases without date limits, including 263 studies (1995-2026), appraised them using QUADAS-2 and matched instruments, and synthesized narratively. Categories were derived from titles, abstracts, and controlled vocabulary; reported prevalence figures represent floors. Duplicate screening achieved high agreement (Fleiss kappa = 0.877), as did appraisal (0.788; 0.390 where observable). Extraction is unaudited. Results: Only 18 of 263 studies (6.8%) recorded both a fidelity metric and reader assessment on identical data, leaving the central surrogate unmeasured. Reader studies mostly measured inter-reader agreement, which was weak: fastMRI 2020 concordance reached 0.457 and 0.386 (Kendall W), improving only where SSIM diverged. Erasing a 100 mm3 lacunar infarct shifts global PSNR by 0.03 dB under the stated error model. As the corpus grew fivefold, reader assessments dropped from 32% to 18%, recovering to 21%. Generative models - most associated with hallucination (39%) - were among the least reader-evaluated (11.3%), while self-supervised models reached 47% with zero reader evaluation. Only 5% released code and ran reader studies; none evaluated a model observer; no named dataset covered acute stroke or hemorrhage. Conclusions: On these floors, current evaluation practices cannot certify diagnostic safety. We derive five requirements safety-oriented evaluations must meet.

0.21

MedSegBenchmarker: A Raw-Count-First Framework for Controlled 2D Medical Image Segmentation Benchmarks

cs.CV cs.AI ·2026-08-30 ·Vanessa Borst, Lukas Horn, Daniel Grillmeyer, Thomas Prantl, Samuel Kounev
benchmark similarity 0.60
Abstract · 10 pages, 4 figures;

Despite rapid advances in MIS, fair and reproducible comparisons of segmentation models remain challenging due to heterogeneous datasets, inconsistent evaluation protocols, and rapidly evolving architectures. In particular, comparisons often implicitly assume that model rankings are invariant to data partitioning, preprocessing, metric aggregation, uncertainty estimation, and computational constraints. The lack of extensible and unified evaluation frameworks further limits systematic investigation of new models, datasets, and training paradigms. We present MEDSEGBENCHMARKER (MSB), a configuration-driven framework for controlled benchmarking of 2D MIS. It integrates duplicate and near-duplicate image detection, group-aware data splitting, YAML study specifications, resumable training, hyperparameter optimization, cross-validation, and checkpoint-based evaluation. Rather than retaining only aggregate performance measures, MSB exports sample- and class-level pixel counts and predictions together with the evaluation context. These elementary artifacts enable post-hoc analyses without repeated inference. We demonstrate MSB in a case study involving three heterogeneous 2D datasets and multiple MIS and general-purpose vision models evaluated at 256- and 512-pixel input resolutions. Reaggregation of identical predictions changes the top-ranked architecture in three of six dataset-resolution settings, despite high rank correlations between aggregation strategies. Increasing input resolution produces model- and dataset-dependent performance gains and losses that must be considered alongside empirically measured inference complexity. These results show that seemingly minor choices in evaluation and experimental setup can affect benchmark conclusions. MSB, available at GitHub, provides a practical and extensible basis for making benchmark conditions and evaluation choices explicit and reproducible.

0.45