CS Paper Radar

GlaucomaMarker - Biomarker-Grounded Glaucoma Vision-Language Model

Ahammed Sakir Nabil, Sadia Siraz, Nikita Chincholkar, Atalie C. Thompson, Jason Xiao, Theodore Leng, Jennifer I. Lim, Minhaj Nur Alam

cs.CV ·submitted 2026-11-20 21:30 UTC · v1

Abstract

Glaucoma is a leading cause of irreversible blindness. In the current clinical setting, glaucoma diagnosis is generally conducted by assessing optic disc cupping and asymmetry. Vision-language models (VLMs) have been utilized in recent years for glaucoma, mostly trained on fixed templates or AI-generated captions, as no public text describes the biomarkers. Our proposed framework, GlaucomaMarker, hypothesizes that retinal structural biomarkers can ground glaucoma-based VLMs. It converts public segmentation masks into sentences describing eleven biomarkers, to teach retinal foundation models to read them. We applied this framework to RETFound (GlaucomaMarker-R) and FLAIR (GlaucomaMarker-F), training on 9,778 images that yielded 45,190 image-text pairs. On a real-world clinical cohort, GlaucomaMarker-F detects glaucoma with an AUROC of 0.905, against 0.848 for FLAIR, and both read the biomarkers where baselines stay near random guessing. Since the biomarker text is computed from existing masks, it comes at no extra cost.

Closest papers

Nearest neighbours by meaning across the whole index.

Auto-GlaKG: Automated Biomarker Reasoning for Explainable Glaucoma Detection

cs.CV cs.AI ·2026-11-08 ·Cheng Huang, Zeyu Han, Yian Hu, Yaopeng Ding, Jingxi Qiu +1 more
similarity 0.71
Abstract

Interpretable glaucoma detection requires a transparent connection between fundus images, clinically meaningful biomarkers, and diagnostic predictions. Knowledge graph (KG) reasoning provides this structure, but performance measured using annotated biomarkers does not establish performance when only images are available. We present Auto-GlaKG, an automated framework that combines image-based biomarker prediction with fixed clinical-prior rules. A ResNet50 network predicts the cup-to-disc ratio (CDR) and six morphological signs using biomarker supervision, and a KG reasoner aggregates their signed rule contributions into a glaucoma score. On 689 fundus images evaluated using stratified, group-aware five-fold cross-validation, Auto-GlaKG achieves a pooled area under the receiver operating characteristic curve (AUC) of 0.951 (95\% confidence interval: 0.931--0.969), with sensitivity of 0.970 and specificity of 0.779. The matched image classifier also achieves an AUC of 0.951, while the rule stage adds 0.2~ms per image. Replacing predicted CDR with its annotation increases fold-mean AUC from 0.953 to 0.995. The framework provides an explicit rule-level account of image-based predictions and identifies CDR estimation as a priority for validation using independently measured biomarkers.

0.20

A Visual Grounding Benchmark for Retinal OCT with Multimodal Large Language Models

cs.CV ·2026-10-22 ·Ronald Fecso, José Morano, Botond Fazekas, Paul Widmann-Sedlnitzky, Dorota Himel +4 more
benchmarkcode/data similarity 0.68
Abstract · Under review at npj digital medicine

Multimodal large language models (MLLMs) can answer clinical questions about medical images, but trustworthy use requires visual grounding: models should localize the pathology they report rather than rely on spurious shortcuts. Whether MLLMs can visually ground clinical findings in retinal optical coherence tomography (OCT), the most widely used imaging modality in ophthalmology, remains largely unexplored. To address this gap, we introduce RetinaGroundBench, the first benchmark for biomarker visual grounding in retinal OCT. It comprises 815 B-scans exhaustively annotated by ophthalmologists with 4,537 bounding boxes covering 13 biomarkers across 8 diseases. Because MLLMs often fragment a single lesion into multiple partial predictions, we propose AggIoU, a metric that evaluates whether the union of overlapping predicted boxes covers the annotated region. Across 27 open-source MLLMs (0.8-38B parameters), we find that visual grounding remains largely unsolved: the best general-purpose model achieves a macro F1 of just 23.7%, with consistently low recall, despite reaching up to 73% balanced accuracy on biomarker presence questions. To narrow this gap, we developed RetGrounder, an MLLM fine-tuned using an OCT-specific strategy integrating grounding and textual information. Despite its relatively small size (8B), RetGrounder improves grounding F1 to 33.9%, a 43% relative improvement. Our benchmark provides a reference point for measuring progress in the field of OCT diagnosis with MLLMs.

0.30

FOCUS: Benchmarking Retinal Model Generalization from Foundation Vision Encoders to Multimodal LLMs

cs.CV cs.AI ·2026-09-27 ·David Restrepo, Chenwei Wu, Luis Filipe Nakayama, Miguel L. Martins, Stergios Christodoulidis +2 more
top venuebenchmarkdatasetcode/data similarity 0.68
Abstract · Accepted at NeurIPS 2026, Evaluations & Datasets Track. Interactive benchmark dashboard: https://huggingface.co/spaces/dsrestrepo/FOCUS-Reti…

Progress in AI-based retinal image analysis has accelerated with the adoption of foundation models, yet evaluating their real-world reliability remains challenging. Performance reported on a single dataset does not capture how models behave under dataset shift, across clinical definitions, or for different patient subgroups. This limitation is particularly critical in medical imaging, where robustness, calibration, and fairness are essential for safe deployment. We introduce FOCUS (Foundation Ophthalmic Cross-Dataset Understanding under Shift), a cross-dataset benchmark evaluating retinal fundus models across vision-only encoder models (VM), vision-language dual-encoder models (VLM), and multimodal large language models (MLLM). FOCUS harmonizes binary diabetic retinopathy, referable diabetic retinopathy, and glaucomatous optic neuropathy tasks across ten public datasets spanning diverse geographies, acquisition conditions, and label protocols. The benchmark evaluates models through a unified analysis layer that measures ranking performance, calibration, subgroup disparities, and image-quality robustness. We present a large-scale evaluation covering 532 base configurations and 228 MLLM configurations adapted via LoRA fine-tuning. Results show no model family consistently dominates across tasks and datasets: general VM encoders achieve the strongest average ranking performance, medical MLLMs are competitive but variable, and dual-encoder VLMs benefit substantially from lightweight adaptation. Fine-tuning improves in-domain performance but exhibits heterogeneous transfer to external datasets, particularly in calibration. FOCUS provides a practical framework and public benchmark to assess generalization, reliability, and robustness beyond single-dataset leaderboards.

0.52

Pseudo-Label Foreground Quality Weighting for Domain-Generalized Fundus Image Segmentation

cs.CV ·2026-09-30 ·Lucas Gabriel Telesco, José Ignacio Orlando
published similarity 0.66
Abstract · 5 pages, 3 figures, 2 tables. Accepted at SIPAIM 2026

Optic disc (OD) and optic cup (OC) segmentation is central to automated glaucoma assessment, but models trained on limited labeled fundus datasets often degrade under domain shift. Semi-supervised Teacher-Student learning can improve generalization by leveraging unlabeled data, yet standard Noisy Student training treats all pseudo-labels as equally reliable. In this paper we investigate a targeted extension of Noisy Student training in which OD- and OC-specific pseudo-label supervision is modulated using a mask-derived reliability estimate. A multitask Dice predictor estimates OD- and OC-specific pseudo-label quality from Teacher-generated masks, and these estimates are used to weight the pseudo-label loss during Student training. This preserves the baseline contribution of low-scoring foreground pseudo-labels while assigning greater relative emphasis to pseudo-labels predicted to be more reliable. Experiments across known and unseen domains show improvements over the Noisy Student baseline, particularly for OC segmentation, while maintaining competitive generalization performance.

0.31

Interpretable AI plus Handheld, Portable Retinal Photographs: A Low-Cost Glaucoma Screening Solution for West Africa

cs.CV cs.AI ·2026-09-22 ·Charis Y. N. Chiang, Tarela Sarimiye, Adeyinka Ashaye, Martin Buist, Michael A. Hauser +2 more
similarity 0.65
Abstract · 31 pages, 2 Tables, 5 Figures, 1 Supplementary Material

Purpose: To develop and evaluate an interpretable artificial intelligence (AI) framework for glaucoma screening from low-cost portable, handheld retinal fundus photographs in a West African population and to compare its performance with clinical tabletop fundus imaging. Methods: We used data from a community-based study of 681 participants (1,362 eyes) in Nigeria, comprising 414 glaucoma, 478 glaucoma suspect, and 470 non-glaucoma eyes. Fundus photographs were acquired using the low-cost handheld, portable Volk Viva retinal camera and the Canon CR-2-AF tabletop camera. We fine-tuned component models separately to each device to perform vessel segmentation, cup and disc boundary segmentation, and feature extraction to detect optic nerve head features. A final classification model combined these components to classify scans as glaucoma, glaucoma suspect or non-glaucoma. Feature-weight analysis and Gradient-weighted Class Activation Mapping were used for interpretation. Results: The models performed well on both Volk Viva and Canon CR-2-AF images: Vessel segmentation: 0.98 Dice Coefficient (DC) (Volk) and 0.94 DC (Canon); Cup and disc segmentation: 0.95 DC (Volk) and 0.96 DC (Canon); Optic nerve head feature detection: area under the receiver operating characteristic curve (AUCs) of 0.83$\pm$0.03 (Volk) and 0.87$\pm$0.04 (Canon); Classification model: AUCs of 0.85$\pm$0.01 (Volk) and 0.93$\pm$0.01 (Canon). Reports for each image, present model decision confidence scores and decision-rationale visualizations to support clinical interpretation. Conclusions: Volk Viva results were reasonably comparable to Canon CR-2-AF in the component models and not far behind in classification. This shows that interpretable AI combined with low-cost, portable imaging may enhance community-level glaucoma screening, especially in settings with limited specialist access and resources.

0.32

EyeVQA: Benchmarking Ophthalmic Vision-Language Models from Recognition to Spatial Grounding

cs.CV cs.AI ·2026-09-26 ·Gujie Shao, Zixun Xie, Xuechun Xing, Ruixiang Wang, Ziyun Lan +5 more
publishedbenchmarkcode/data similarity 0.64
Abstract · Accepted to MICCAI 2026 CREATE Workshop. 19 pages, 2 figures, 2 tables. Project page: https://github.com/PKUTHM/EyeVQA

Vision-language models (VLMs) have shown increasing potential for medical image understanding, yet their capabilities in ophthalmic imaging remain insufficiently characterized. Existing ophthalmic datasets are typically designed for individual diseases or specialized tasks, making it difficult to systematically evaluate whether VLMs can move beyond disease recognition toward comparative reasoning and fine-grained spatial grounding. We introduce EyeVQA, a unified visual question answering benchmark for comprehensive evaluation of ophthalmic VLMs. EyeVQA is constructed from 21 available ophthalmic datasets and contains 20,000 question-answer pairs spanning six disease groups and seven question types: Single-Choice, Multi-Select, Variable-Select, True-False, Ranking, Point Location, and Bounding Box. Gold answers are deterministically derived from source-provided diagnoses, severity grades, clinical findings, segmentation masks, bounding boxes, and anatomical landmarks, enabling reproducible evaluation without relying on model-generated annotations. Notably, 44.5% of the questions require reasoning across multiple images, extending evaluation beyond conventional single-image medical VQA. We benchmark fourteen representative general-purpose, scientific, and medically specialized VLMs under a unified zero-shot protocol. The best-performing model only achieves an overall score of 62.8, while substantial gaps remain in spatial grounding and cross-task generalization. These results highlight the limitations of current VLMs in comprehensive ophthalmic visual understanding and establish EyeVQA as a diagnostic benchmark for developing more reliable and spatially grounded ophthalmic multimodal models. The project page is available at https://github.com/PKUTHM/EyeVQA.

0.42

Co-Annotator: Expert-Distilled ViT and VLM for Visual and Documentation Guidance in Age-Related Macular Degeneration

cs.AI cs.HC ·2026-08-31 ·Ziheng "Leo" Li, Benjamin Freeman, Akshay Raman, Kavin Aravindhan Rajkumar, Xinxin Fang +3 more
top venue similarity 0.63
Abstract · 23 pages, 11 figures. To appear in UIST '26: Proceedings of the 39th Annual ACM Symposium on User Interface Software and Technology, Novembe…

Clinical AI often optimizes predictive performance without engaging how clinicians decide where to look and what to write. We present Co-Annotator, which distills expert gaze and dictation into two guidance components: a gaze-aligned Vision Transformer producing fixation-aligned areas of interest (AOIs), and an ontology-bounded vision-language model (VLM) that pre-fills editable biomarker summaries for retinal optical coherence tomography (OCT). We first collect expert gaze and dictations (US1) to train the models, significantly improving diagnostic accuracy and biomarker generation. We then deploy the system with ophthalmology residents: a controlled resident study (US2) confirmed each modality is safe and independently beneficial, with AOI guidance producing lasting perceptual efficiency gains through post-guidance carryover and VLM guidance more than doubling biomarker documentation breadth. In a combined deployment across two academic institutions (US3), providing both modalities simultaneously produced efficiency gains that substantially exceeded either modality alone: correct diagnoses per minute increased by 40% and comment editing time fell by 67%, without compromising diagnostic accuracy. Notably, neither modality improved efficiency during guidance in US2, which makes the in-guidance efficiency gain under combined guidance in US3 the more striking result. Expert-distilled multimodal guidance can remove two distinct clinical workflow bottlenecks at once (visual search overhead and documentation burden) without compromising the diagnostic accuracy clinicians already achieve.

0.40

Detecting Glaucoma Across Multi-ethnic Myopic and Non-Myopic Populations Using an Uncertainty-Aware Vision Transformer: A Multicentre Model Development and Validation Study

cs.CV cs.AI ·2026-09-24 ·Raghavan Lavanya, Yangqin Feng, Ten Cheer Quek, Quan V. Hoang, Linda Yi-Chieh Poon +34 more
similarity 0.63
Abstract

Background: Artificial intelligence (AI)-based glaucoma detection from colour fundus photographs (CFP) offers scalable screening, but performance may decline on external datasets because of differences in ground-truth definitions, populations, and coexisting conditions such as high myopia (HM). We developed and validated a Vision Transformer-based deep learning (DL) model for glaucoma detection across multi-ethnic cohorts with and without HM. Methods: A ViT-B/16 model with predictive uncertainty estimation was developed using 56,483 CFPs (57.1% with myopia; 14.4% with HM). Glaucoma labels were standardised using clinical, imaging, and perimetry data. The model was validated on 16 independent datasets across three continents, including four datasets with explicit HM labels. Findings: Internal AUROC was 98.7% (95% CI 98.2-99.1%), with sensitivity 94.5% and specificity 97.3%. Across 16 external datasets from eight countries, AUROCs ranged from 86.4% to 99.6%. In HM eyes, internal AUROC was 97.8% (95% CI 96.1-99.2%), with sensitivity 94.8% and specificity 93.7%. External HM AUROCs were 86.5% in the Beijing Eye Study and 93.3%, 91.8%, and 85.5% in hospital-based datasets from Taiwan, Thailand, and South Korea. In an exploratory HM clinical evaluation, the model had higher CFP-only diagnostic accuracy than ophthalmologists and trained graders (92.0% vs 70.0%; p=0.008) and performed comparably to glaucoma specialists using full clinical information. Interpretation: The model showed robust glaucoma detection across myopic and non-myopic multi-ethnic populations and may support AI-assisted screening in settings with high HM prevalence.

0.28