Near-Field Physical-Layer Authentication Under Noisy Enrollment
Abstract
In near-field physical-layer authentication (PLA), the receiver estimates a spatial reference from noisy enrollment pilots. With a fixed residual-energy threshold, even a small reference error can cause the false rejection (FR) probability to approach one as the received energy increases. We derive the distribution of the overlap between the true and enrolled spatial directions and use it to calibrate a test based on the aligned energy and the residual-to-aligned energy ratio. The calibration bounds FR for arbitrary regional gains and all legitimate received energies above a prescribed minimum. For a fixed enrolled reference, we reduce the problem of finding the maximum acceptance probability of a multi-antenna attacker to a one-dimensional search. We also derive a pre-enrollment upper bound that holds when the attacker chooses its precoder after observing the enrolled reference. For a single region and a fixed angular threshold, the enrollment energy sufficient to preserve angular separation grows inversely with the square of the available angular margin. In the numerical study with 128 receive elements at 28 GHz, the FR upper bound was 0.9984, including the enrollment outage allowance. At a regional phase perturbation of 20, four regions provided the best trade-off among the tested partitions: its simulated FR was 0.1442, while its false acceptance (FA) at 9 m was 1.084 under the fixed transmit-energy setting.