CS Paper Radar

How Seasonal Reference Choice Changes the Apparent Gains of Chronos Models in Electricity Load Forecasting

ChandraMohan K

cs.LG ·submitted 2026-11-22 17:57 UTC · v1

Abstract

When a forecasting model is said to beat a simple baseline, the size of that win depends on which baseline was used. We measure how much this matters for two zero-shot foundation models, Chronos-Bolt and Chronos-2, on hourly electricity load. The study uses 60 fixed cases drawn from eight series in four public collections, with forecasts 24 and 168 hours ahead and up to 2,048 hours of history. Each model is compared with daily persistence, weekly persistence, a weekday hybrid, a daily-weekly blend, and a reference chosen from these on a validation period. We keep every origin-level forecast and estimate uncertainty with paired circular block bootstrap intervals using 168- and 336-hour blocks. A week ahead, Bolt clearly beats weekly persistence in 21 of 30 cases but the validation-selected reference in only 14, and its median gain falls from 17.3% to 11.9%. For Chronos-2 the clear-win counts are 18 and 15. Chronos-2 has lower week-ahead MAE than Bolt in 24 cases, yet only 12 of those differences are clear. The selected reference is not always the harder baseline, since on some test windows it does worse than weekly persistence. The choice of baseline therefore changes both how large the reported gain is and how sure we can be of it. The results are exploratory: the series and windows are related, an earlier pilot was inspected, pretraining overlap cannot be ruled out, and the case-level intervals are not corrected for multiple comparisons.

Comment
8 pages, 3 figures, 3 tables

Closest papers

Nearest neighbours by meaning across the whole index.

EnergyBench: a live, gate-aligned benchmark of day-ahead forecasts for European power markets

cs.LG eess.SY ·2026-11-05 ·Evgenii Genov, Ander Martinez Alonso, Christoph Bergmeir
benchmark similarity 0.66
Abstract · 21 pages, 10 figures, 7 tables. Live benchmark at https://energybench.foretec.co

Energy forecasting models are usually compared on backtests and fixed public datasets. Backtests can use data that did not yet exist when the forecast would have been made, and a fixed test set, reused across studies and possibly contained in the pretraining data of foundation models, invites overfitting to the benchmark. EnergyBench evaluates every entry live instead. Each day at 11:30 CET/CEST, thirty minutes before the day-ahead (SDAC) gate closes, every model forecasts the next day's price, wind and solar generation and load on the 15-minute grid for six bidding zones (BE, NL, FR, DE-LU, DK1, DK2). Unlike existing live benchmarks, EnergyBench runs the models itself, on one information set that it freezes at the cut-off and publishes, including three numerical weather prediction models, so that foundation models can be compared with and without the same weather covariates under the actual market deadline. Errors are pooled per series against a seasonal-naive baseline, and models are ranked by a Bradley-Terry rating on the Elo scale with a day-bootstrap interval. The field spans baselines, linear and gradient-boosted models on the frozen weather, eighteen time-series foundation models from eleven families, ensembles, and the grid operators' own forecasts. Over the first thirty-two live days, the covariates reduced the error of each of the ten foundation models run with and without them by 37-51% on matched races (64-73% on wind, 48-61% on solar). Used zero-shot, these models match or outperform a LightGBM model trained on the same covariates. Model size, from 3M to 331M parameters, has a much smaller effect, and median ensembles of the covariate models rank highest. The grid operators' pre-gate forecasts remain ahead on wind and solar, where the best single foundation models have 16-22% more error; on load the gap is 4-6%, within the intervals.

0.29

How Much Computation Does Every Forecast Need? Structured Block Skipping in Two Time-Series Foundation Models

cs.LG ·2026-10-09 ·Max Bourgeat
similarity 0.66
Abstract

Time-series foundation models use the same network depth for every input, although forecasting windows differ in structure and difficulty. We test whether whole Transformer blocks can be removed at inference time in two pretrained models: Chronos-Bolt and TimesFM 2.5. Our bypasses avoid the original block computation and preserve the dense model exactly when all blocks are enabled. Masks are selected only on calibration windows and evaluated on 1,088 held-out windows from ETTh1, Traffic, Weather, and Exchange. At moderate sparsity, Chronos-Bolt with 7/11 candidate blocks and TimesFM with 16/20 blocks show little change in mean relative forecasting quality across datasets while reducing median A100 batch-1 latency by 11.2% and 13.4%. More aggressive TimesFM skipping accelerates inference further but substantially harms Traffic and Weather. Across both models, different equal-budget masks win on different windows, and a retrospective oracle significantly improves over the best static mask on every dataset. However, dataset-specific masks transfer inconsistently, and Chronos representations do not support reliable unseen-domain routing. These results establish cross-architecture structured redundancy and input-dependent opportunity, but not a deployable dynamic inference method.

0.24

Zero-shot time-series foundation models against the Khepri v1.5 baselines for 96-hour carbon-intensity forecasts in nine Nordic bidding zones: a preregistered comparison

cs.LG physics.soc-ph ·2026-11-02 ·Eirik Botten Nicolaysen
code/data similarity 0.65
Abstract · 15 pages. Code, data and preregistration proofs: https://doi.org/10.5281/zenodo.23881315

We compare three zero-shot time-series foundation models (Timestral-5M, Timestral-209M and Chronos-2, 8192-hour context, no covariates) with the Khepri v1.5 SARIMA and GBM baselines, with their code and hyperparameters unchanged, for 96-hour forecasts of hourly carbon intensity in the Nordic bidding zones NO1-NO5 and SE1-SE4. The design, the analysis code and a minimum detectable effect (MDE) were timestamped before any foundation-model forecast by an OpenTimestamps proof (Bitcoin-confirmed) and the GPG-signed tag prereg-v1; the proofs are archived in Zenodo (DOI 10.5281/zenodo.23881315). The preregistration was also submitted to OSF Registries 2026-11-02 07:49 UTC (osf.io/hncz5; embargo requested, pending OSF approval). On the 2025 test (361 daily origins, contamination not ruled out) all three models have a lower zone-averaged MAPE than both baselines, by 0.952 to 1.347 percentage points (Diebold-Mariano with the Harvey-Leybourne-Newbold correction, all p < 0.0001), and each beats SARIMA in 9 of 9 zones. On a post-release holdout of 14 origins from 2026-10-16 the point estimates have the same sign (0.729 to 1.326 percentage points lower), but all lie within the preregistered MDE of 2.989 points and are reported as not determined. For calibration (RQ4) the preregistration locked a Diebold-Mariano-HLN test on CRPS; the MDE applies to MAPE only. Holdout CRPS point estimates (n = 14) are 1.1114 (Timestral-5M), 1.0733 (Timestral-209M) and 1.1198 (Chronos-2) against 1.4165 gCO2-eq/kWh for SARIMA (each p < 0.0001). The SARIMA quantiles are constructed from the fitted model's Gaussian predictive distribution (deviation D-03), not taken from a native v1.5 forecast, so the difference may partly reflect the SARIMA intervals. The contamination indicator does not exceed its preregistered threshold for any comparison; with 14 holdout origins it has low power (HAC standard errors 0.124 to 0.360 pp).

0.43

Benchmarking Time Series Foundation Models for Load Forecasting Under Covariate Uncertainty

cs.LG eess.SY ·2026-10-05 ·Tomas Kaljevic, Ivan Arzola, Yu Zhang
publishedbenchmark similarity 0.65
Abstract · 5 pages, 1 figure, 5 tables. Accepted to the 2027 IEEE PES Grid Edge Conference & Expo, Salt Lake City, UT, USA, 19-22 April 2027

Accurate short-term load forecasting (STLF) is essential for the reliable and efficient operation of modern power systems. While time series foundation models (TSFMs) have recently demonstrated remarkable performance across a wide range of forecasting tasks, their effectiveness for STLF under realistic operational conditions remains largely unexplored. In this paper, we present a comprehensive benchmark of four trained-from-scratch (TFS) models and four TSFMs across three real-world load forecasting datasets under operational scenarios that differ in the availability and quality of future covariate information. Our results show that Chronos-2 consistently achieves state-of-the-art performance in both zero-shot and fine-tuned settings when future covariates are available or accurately forecast. However, its performance degrades as covariate forecasts become increasingly noisy, whereas TimesNet exhibits greater robustness under severe covariate uncertainty. These findings demonstrate the effectiveness of covariate-informed TSFMs for STLF while highlighting the critical role of robust covariate modeling in real-world forecasting applications.

0.19

Parameter-Efficient Adaptation of Time Series Foundation Models for Electrical Load Forecasting

cs.LG cs.AI ·2026-10-20 ·Aliullah, Julian Oelhaf, Edouard Fouché, Jessica Deuschel, Christian Bergler +2 more
published similarity 0.64
Abstract · Accepted for presentation at the IEEE Power & Energy Student Summit (PESS 2026), Karlsruhe, Germany. 6 pages, 4 figures, 1 table

Accurate electrical load forecasting supports power-system operation across countries, regions, cities, and buildings, but repeated development of target-specific models is costly. Time series foundation models (TSFMs) provide reusable pretrained backbones, although multi-domain pretraining may not fully capture load-specific characteristics. This paper compares pretrained inference, full fine-tuning, and low-rank adaptation (LoRA) in terms of forecasting accuracy and adaptation efficiency across four electrical load aggregation levels. MOIRAI 1.0 Large serves as the primary backbone, while Chronos-2 assesses whether the findings transfer across model families. The evaluation covers both in-distribution (ID) and out-of-distribution (OOD) settings and examines whether compact adaptation provides consistent gains over strong pretrained checkpoints. Pretrained foundation models outperform the implemented seasonal naive and XGBoost baselines across the evaluated aggregation levels. On MOIRAI Large, rank-16 LoRA reduces normalized mean absolute error (NMAE) by 7.5% on average while updating 3.146 million parameters, about 1% of the model, and retains most of the improvement from full fine-tuning. Chronos-2 achieves lower pretrained NMAE than MOIRAI, while its relative adaptation gains remain smaller overall. OOD results show that adaptation benefits vary by target, with the clearest gains for the local-area series and several buildings. Overall, LoRA provides a favorable accuracy-efficiency trade-off when adaptation yields a meaningful gain over a strong pretrained checkpoint.

0.28

Do Time-Series Foundation Models Forecast Index-Futures Returns? A Preregistered Evaluation of Models, Metrics, and Input Representations

cs.LG ·2026-11-09 ·Rishabh Upadhyay
benchmark similarity 0.63
Abstract

We ask whether the apparent forecasting skill of frozen time-series foundation models (TSFMs) on intraday index-futures returns is incremental skill. In a pre-registered evaluation on E-mini Nasdaq-100 (NQ) and E-mini S&P 500 (ES) futures, a common panel of five zero-shot models (Chronos-Bolt, Chronos-2, TimesFM 2.5, Moirai 2.0 and TiRex), plus separate experiments with Kronos, is compared with a no-change forecast at 5-120 minutes, using native prices, log returns, volatility-standardised returns and a volume clock as inputs. On a blind set opened once, 0 of 160 model-representation-horizon-market cells beat no-change, and a Hansen SPA test gives p = 1.000 on both markets; a later retrospective hold-out, scored as a descriptive check, gives 0 of 120. Input representations change forecast magnitude but not accuracy, and a transformation-aware ridge regression does as well. Several standard measures nevertheless suggest skill. Price-level correlation exceeds 0.9996, but no-change scores higher. Within-day RankIC across forecast origins rewards a trivial revert-to-mean rule (+0.35 at 30 minutes); we derive the expected within-day covariance under a random walk in closed form, and a sign-randomised null reproduces about 95% of the observed value. One model beats HAR for 5-minute volatility, but not the EWMA its input already contains. On strongly planted synthetic signals the models recover part of the signal at 5 minutes, and recovery deteriorates at 30 minutes. Benchmark-level success of TSFMs should therefore not be assumed to carry over to low-signal domains such as intraday returns.

0.25

Chronos-2: A foundation model for multivariate time series forecasting

cs.LG cs.AIstat.ML ·2026-10-30 ·Abdul Fatir Ansari, Oleksandr Shchur, Jaris Küken, Andreas Auer, Boran Han +20 more
code/data similarity 0.61
Abstract · 41 pages, 9 figures. Extended version of the Chronos-2 technical report (arXiv:2510.15821), adding scientific case studies (epidemiology, ma…

Accurate forecasting with uncertainty quantification is critical in a variety of scientific applications ranging from epidemiology and economics to energy systems and earth sciences. Yet most forecasting models still need to be developed and trained separately for each domain-specific dataset. Time series foundation models (TSFMs) aim to remove this limitation and enable the application of the same model across domains through large-scale pretraining. However, most existing TSFMs treat each time series independently and therefore cannot model interactions among time series and external drivers. Here, we introduce Chronos-2, a foundation model for zero-shot forecasting that models the interactions between multivariate time series and heterogeneous covariates, which commonly arise in scientific applications. The model infers relationships among time series directly from historical context and generates probabilistic forecasts without task-specific treatment. Across various benchmarks, Chronos-2 achieves state-of-the-art accuracy on average by improving skill scores by 5.2 percentage points relative to the strongest baselines and increasing win rates by 10 percentage points. Chronos-2 is also computationally efficient, generating forecasts for 100 time series in under one second on a single mid-range GPU, 50x and 1000x faster end-to-end than the best task-specific point and probabilistic forecasters, respectively. In addition, we demonstrate its effectiveness in diverse scientific settings -- including infectious-disease forecasting, macroeconomic modeling, carbon-flux prediction, and runoff simulation -- where the model matches or surpasses specialized methods developed for each domain. These results show that a single pretrained model can capture structure shared across temporal systems.

0.21

Stealing profits: Spread-based temporal hierarchy forecasting for day-ahead electricity markets

cs.LG q-fin.STecon.EM ·2026-09-19 ·Arkadiusz Lipiecki, Nikolaos Kourentzes, Rafal Weron
similarity 0.61
Abstract

Day-ahead electricity price forecasts support trading and storage decisions, but for battery arbitrage predicting intraday price spreads is more relevant than predicting individual hourly prices. Here we show that a temporal hierarchy forecasting (THieF) framework that jointly reconciles forecasts of hourly electricity prices and all intraday price spreads consistently improves performance across two major European electricity markets and three different forecasting architectures. Using five years of out-of-sample data from Germany and Spain, we obtain accuracy improvements of up to 19.7% and profit gains of up to 10.4% relative to unreconciled hourly price forecasts. The gains persist even for a highly accurate pretrained TabPFN foundation model. Our results demonstrate that exploiting coherent relationships between economically relevant forecasting targets can improve both predictive accuracy and decision value, and that better statistical forecasts do not necessarily imply better economic decisions.

0.10