Leveraging Fast Healthcare Interoperability Resources (FHIR) for the Exchange of Wearable Inertial Sensor Data: Design and Development Study

Gabriela Ciortuz, Joshua Wiedekopf, Hannes Ulrich, Hawzhin Hozhabr Pour, Sebastian Fudickar

cs.CY cs.DBcs.LG ·submitted 2026-11-23 16:30 UTC · v1
survey

Abstract

Continuous monitoring with wearables can support the assessment of frailty, functional decline, and movement disorders, but raw inertial measurement unit (IMU) recordings are typically stored in proprietary files that electronic health records cannot exchange or interpret. HL7 Fast Healthcare Interoperability Resources (FHIR) standardizes health data exchange, yet existing FHIR profiles for personal health devices target spot measurements and short waveforms, not long multichannel motion recordings with their recording context and activity labels. We present WHIR (Wearable Health Interoperable Recordings), a FHIR R5-based information model and implementation guide for wearable IMU recordings. Metadata requirements were derived from a review of 23 published human activity recognition datasets and formalized in a FHIR-independent information model, which was then mapped to FHIR R5 and authored in FHIR Shorthand. Raw signals are kept in files referenced through DocumentReference resources, so that FHIR holds the metadata and activity labels. Terminology reuses SNOMED CT, LOINC, and ISO/IEEE 11073 concepts wherever available. The implementation guide defines 9 profiles, 4 extensions, 10 code systems, and 15 value sets; all artifacts and 67 example instances passed the conformance checks of the HL7 FHIR IG Publisher without errors. Two use cases, machine learning training data and automated home-based geriatric assessment, were implemented as conformant example instances, and we compare the model with the HL7 Personal Health Device Implementation Guide. WHIR provides a FHIR R5-conformant representation of wearable IMU recordings together with device metadata, sensor placement, and time-aligned activity labels, covering concepts that the Personal Health Device Implementation Guide does not address. The implementation guide and its sources are openly available for reuse and extension.

Closest papers

Nearest neighbours by meaning across the whole index.

Rotation-Invariant Multi-IMU Activity Recognition under Independent Per-Location Orientation Shifts

cs.AI cs.LG ·2026-08-16 ·Seungyeol Baek, Yoonbyung Chai, Yonghyeon Lee, Sungjoon Choi, Sungho Suh
published similarity 0.64
Abstract · 6 pages, 2 figures. ACM International Symposium on Wearable Computing (ISWC) 2026

Human Activity Recognition (HAR) with self-administered wearables, such as at-home rehabilitation and exercise monitoring, often requires reattaching inertial measurement units (IMUs) across sessions. In multi-IMU settings, this can induce independent orientation offsets across body locations, a deployment shift that conventional scalar HAR models do not structurally handle. Existing remedies rely on rotation augmentation, whose robustness depends on sampled transformations, or calibration and orientationnormalization pipelines requiring additional reference-frame assumptions or explicit procedures. We present Truly Rotation-Invariant HAR (TRI-HAR), a rotation-invariant framework that makes robustness to independent per-location IMU orientation offsets a structural model property. TRI-HAR reshapes accelerometer and gyroscope streams into triaxial vectors, applies a shared SO(3)-equivariant backbone and invariant projection to each IMU location, and fuses the resulting invariant features for activity classification. Across four multi-IMU benchmarks, TRI-HAR preserves macro-F1 under fixed independent per-location SO(3) rotations and outperforms rotation-augmented baselines under this target shift without requiring rotational augmentation.

0.58

Learning Human Health and Diseases from 24-hour Wrist Movement

cs.LG ·2026-08-30 ·Yong Wang, Dylan McGagh, Katya Broomberg, Zizheng Zhang, Jonathan Carter +19 more
similarity 0.62
Abstract

Much of human health and function unfolds beyond the clinic, through the movements of everyday life. Wrist-worn accelerometers capture these movements continuously, yet their rich signals are often reduced to a small set of predefined behavioural summary measures. Here, we present Sensori, a self-supervised foundation model that learns general-purpose health representations directly from 24 hours of raw tri-axial wrist movement. We developed and evaluated the model across four population-based cohorts from the United Kingdom, China and the United States, comprising 122,640 participants contributing 683,617 person-days of free-living recordings. Sensori condensed each day of movement into a representation that captured diverse movement behaviours, demographic characteristics, health axes and physical function. Evaluation in independent cohorts showed that these representations generalised across populations and measurement settings without retraining. When added to common clinical covariates, Sensori significantly improved prevalent disease classification for 52 of 102 eligible conditions (median delta AUROC, 0.060; range, 0.012-0.242) and incident disease risk prediction for 26 of 87 eligible conditions (median delta Uno's C-index, 0.064; range, 0.025-0.172), with the largest gains for neurological and psychiatric disorders. These findings establish 24-hour wrist movement as a rich and scalable source of health information, with the potential to support passive health monitoring and disease prediction at population scale.

0.28

Foundation models for movement data: Are they ready for prime-time?

eess.SP cs.LG ·2026-08-13 ·Alexander Bräuer, Benjamin Cauchi, Nils Strodthoff
code/data similarity 0.62
Abstract · 14 pages, 6 figures, 8 tables, code is available at https://github.com/AI4HealthUOL/movement-fm-benchmarking

Foundation models (FMs) trained on large-scale accelerometer data have been proposed as general-purpose feature extractors for health monitoring, but systematic evidence of their advantages is lacking. We present the first comprehensive evaluation of four open-source accelerometer FMs against supervised baselines covering 19 tasks across the domains of activity recognition including activities of daily living, clinical monitoring, and physiological inference. We find task-dependent performance results: supervised models remain competitive with FMs on human action recognition (HAR), with no consistent advantage for either, while selected FMs lead on fall and stress detection and are the most robust to sensor-placement variation. As frozen feature extractors, FMs are strongest for demographic inference, whereas sleep staging performance remains near chance level for all models. The internal FM representations show strong similarity across layers, highlighting potential for future FM improvements. Linear and frozen probing reveals that UniMTS provides the strongest representations and is the only FM that surpasses the supervised baselines without finetuning. Concept discovery analysis shows all models capture high-intensity activities clearly but struggle with sedentary, complex or ambiguous activities. We provide scenario-based deployment recommendations. Furthermore, we identify FM-derived activity profile inference-moving beyond fixed category classification-as a promising research direction.

0.30

Personalized health coaching via coachable health age and counterfactual wearable trajectories

cs.LG q-bio.QM ·2026-11-05 ·Simon A. Lee, Zeinab Esmaeilpour, Menglian Zhou, Marius Guerard, Sohrab Sidhu +15 more
similarity 0.62
Abstract

Personalized health coaching requires moving beyond retrospective wearable summaries toward quantitative, actionable behavioral prescriptions. We introduce Coachable Health Age (CHA), an interpretable health-age metric built from modifiable physiological and behavioral signals passively captured by consumer wearables. Across the WEAR-ME (N=2,780), All of Us (N=22,748), and longitudinal Fitbit (N=1,464) cohorts, CHA aligns with established cardiometabolic health constructs and improves prognostic discrimination for incident cardiovascular and metabolic disease beyond age, sex, and body mass index. To enable prospective behavioral optimization, we developed Sensor World Model (SensorWM), an action-conditioned wearable world model pretrained on over 2.2 million person-weeks of longitudinal sensor data from approximately 100,000 participants. SensorWM accurately forecasts multi-week physiological responses to candidate lifestyle changes ($R^2=0.664$), outperforming generic time-series foundation models while preserving downstream clinical signal for diabetes, hypertension, and other health outcomes. Finally, we integrate CHA and SensorWM into an agentic counterfactual coaching system to synthesize personalized 12-week coaching plans. In blinded paired reviews, certified lifestyle coaches preferred counterfactual-grounded plans over plans grounded in wearable history alone for overall quality (71.4%, P < 0.001) and anticipated adherence (71.0%, P < 0.001), and board-certified clinicians judged 99.2% of counterfactual-grounded plans to meet clinical safety criteria (vs. 97.6% of comparison plans). Automated evaluations across the full cohort (N=2,780) also favored counterfactual-grounded plans. By closing the loop between longitudinal tracking, trajectory prediction, and counterfactual coaching, our framework provides a scalable path to systematically improve cardiometabolic health.

0.14

An Event-Driven Cloud-Native Wearable Analytics Framework for Real-Time Clinical Workloads

cs.DC ·2026-08-11 ·Elias Grünewald, Daniil Cherepko, Linus Gustafsson, Jakob Möhler, Oskar Rabe +5 more
code/data similarity 0.60
Abstract · Wearables, Cloud Native, Stream processing, FHIR, Clinical Decision Support

Continuous physiological monitoring using consumer-grade wearables offers a transformative opportunity for clinical care and research, yet integration remains hindered by device heterogeneity, proprietary data formats, and strict regulatory requirements. We present an event-driven, cloud-native system designed to ingest, normalize, and analyze high-frequency vital signs from wearables at scale and without vendor lock-in. The system design proposes a multi-layered microservice architecture using cluster orchestration. Data acquisition is handled via a cross-platform mobile application that leverages native health frameworks, ensuring compatibility across fragmented device ecosystems. To address interoperability, we implement an event-driven transformation pipeline using stream processing engines and specialized services to map raw measurements to the FHIR standard for medical interoperability. Our novel dependency-aware FHIR minimization scheme reduces storage overhead while maintaining lossless resource reconstruction. Furthermore, the platform integrates a modular data analytics and machine learning layer based on a medallion lakehouse architecture, supporting the full machine learning lifecycle from real-time stream processing to model serving. Performance evaluation demonstrates that the ingestion pipeline sustains 50 full ingestion requests per second with median response times under 8 ms, satisfying the low-latency requirements for real-time patient monitoring. Our open-source implementation adheres to regulatory compliance standards through role-based access control and secure service-to-service communication, providing a robust foundation for deploying wearable-based monitoring in institutional healthcare settings for clinical decision support and research workloads.

0.20

HeteroWear: Sensor-Aware Self-Supervised Learning for Heterogeneous Wearable Activity Recognition

cs.LG cs.AIeess.SPstat.ML ·2026-11-13 ·Yasaman Mohammadpour, Pouya Shaeri
publishedcode/data similarity 0.60
Abstract · Extended version of a paper accepted at IEEE BigData 2026. Code: https://github.com/yasamanmohammdpour/HeteroWear

Self-supervised learning for wearable sensing is usually confined to a single dataset or device family, leaving open whether representations transfer across heterogeneous sensor configurations and whether gains come from pretraining rather than architecture or richer sensor input. We present HeteroWear, a sensor-aware self-supervised framework pretrained on an eight-dataset wearable corpus (173 subjects, 358,261 windows) spanning inertial and physiological signals across body locations, devices, and sampling rates. HeteroWear separates within-sensor temporal modeling from cross-sensor relational modeling using sensor-context embeddings, temporal and cross-sensor Transformers, and latent cross-attention fusion. Training combines structured sensor dropout, cross-configuration consistency, and per-axis masked sensor modeling; missing sensors are omitted rather than reconstructed. Under leave-one-dataset-out pretraining and subject-disjoint evaluation on PAMAP2, WISDM, HHAR, HARTH, and UCI-HAR, HeteroWear improves mean macro-F1 from 0.688 to 0.724 over the identical architecture trained from scratch, with the largest gain on HHAR (0.823 versus 0.741), and achieves the highest macro-F1 on four of five benchmarks relative to single-accelerometer supervised baselines. Held-out-device evaluation yields a mean +0.066 macro-F1 improvement. Under 50% test-time channel removal, HeteroWear retains 73.8% of full-channel performance versus 64.1% for the same architecture trained from scratch without sensor dropout. Ablations show that structured sensor dropout primarily drives robustness, while cross-configuration consistency and sensor-context encoding contribute to transfer.

0.24

Health Ikigai: Semantic Conversational Interfaces for Wearable Health Data to Support Behavioral Change for Senior Indian

cs.HC ·2026-11-21 ·Md Haseen Akhtar, Hansoo Lee, Rafael A. Calvo
published similarity 0.59
Abstract · 5 pages, 5 figures, 1 table. Poster presented at UbiComp/ISWC 2026, Shanghai, China; to appear in UbiComp Companion '26 (ACM). Md Haseen Akh…

In ubiquitous health contexts, wearable feedback is often encountered in brief, interrupted moments of everyday life. However, many wearable and mobile health systems still present personal health data through numerical dashboards, leaving users and health coaches to interpret trends, thresholds, and deviations on their own. This interpretive burden may be especially relevant for adults aged 50-65 in India, where digital literacy, health literacy, language, and daily routines can shape how health technologies are understood and used. We present Health Ikigai, a design-oriented proof-of-concept framework that reframes wearable activity feedback from dashboard-based numerical interpretation to semantic conversational feedback. The prototype transforms replayed wearable-derived activity data into baseline-aware triggers, plain-language feedback, limited-turn conversational prompts, and coach-facing review summaries. A preliminary formative evaluation with ten adults in India suggests that participants perceived the interaction as understandable, lightweight, supportive, and actionable. We discuss design implications for low-burden wearable health interfaces that preserve coach oversight while reducing users' interpretive work.

0.31

GaitFM: A Cross-Modal Foundation Model for Wearable Gait Assessment

cs.CV ·2026-11-01 ·Yize Cai, Zhiqing Hong
similarity 0.59
Abstract · 18 pages, 4 figures

Gait assessment supports the diagnosis, monitoring, and prognosis of diverse movement-related conditions, such as neurological and musculoskeletal disorders. Recent advances in deep learning using everyday wearable inertial measurement units (IMUs) offer an accessible and low-cost approach to automated gait assessment. However, IMU measurements vary substantially across individuals, body locations, and device configurations, while existing deep learning models are typically developed using small, homogeneous datasets for specific clinical tasks, limiting their robustness and generalizability in diverse real-world contexts. Here we present GaitFM, a cross-modal foundation model for gait assessment using IMU sensors. GaitFM improves the generalizability of gait assessment by transferring knowledge from large vision models and pretraining on unlabeled IMU sensor data. We pretrain GaitFM on a large curated dataset comprising about 4,000 participants and 1.23 million gait windows across diverse clinical and daily conditions, sensor modalities, and body locations. GaitFM demonstrates strong performance across 18 gait-related tasks, including 3 gait parameter estimation tasks, 14 disease and gait abnormality detection tasks, and 1 clinical outcome prediction task. Furthermore, GaitFM generalizes across different sensor configurations and body locations, including those commonly used in clinical settings and everyday wearable devices. These findings demonstrate the effectiveness of transferring visual knowledge in improving sensor-based gait assessment performance, offering a new promising pathway for addressing data scarcity in the sensor and medical domains.

0.13