CS Paper Radar

Longitudinal Characterization of Personalized Hydration Dynamics Using a Facial-Video Digital Hydration Biomarker

Janindu Athukorala, D. M. J. Prathapa, Thanveer Ahamed, Yudara Kularathne

cs.CV q-bio.QM ·submitted 2026-11-24 10:16 UTC · v1

Abstract

Background. Hydration is often assessed at a single time point despite continuous changes in body water. A facial-video biomarker has tracked hydration-state transitions, but its longitudinal behavior is unclear. Objective. To assess within-person hydration score changes, individual differences in fluid response, and implications for personal calibration. Methods. Five adults completed water and electrolyte days with an identical 2.0 L fluid schedule, using facial videos every 30 minutes over 12 hours (250 videos). On a separate morning, each completed a 500 mL electrolyte challenge with baseline and four follow-up videos over 2 hours (25 videos). Analyses assessed trajectories, post-drink changes, variability, time at or above score 50, and exploratory effects of starting score and beverage day. Results. The first scan was the day's lowest on 7 of 10 days. Across 50 intakes, the mean post-drink change was +4.0 points, exceeding a shuffled-time comparison (p less than 0.001). For 21 intakes starting below 50, no subsequent score fell; the mean rise was +11.3 points versus +5.7 expected under permutation (p less than 0.001). Intakes starting at 50 or above showed no rise beyond chance. After 500 mL electrolytes, mean change over 2 hours was positive for all five participants, with peak increases of 7.2 to 22.6 points at 30 to 90 minutes. Despite identical fluid schedules, time at or above 50 ranged from 16% to 100%. The electrolyte day showed a greater mean increase from morning baseline than the water day (+7.7 points), although day order was fixed. Conclusion. Facial-video hydration scores showed longitudinal changes associated with drinking and marked individual differences. These exploratory findings support further research on personal calibration and hydration protocols in larger controlled studies.

Comment
18 pages, 8 figures, 5 tables

Closest papers

Nearest neighbours by meaning across the whole index.

Validation of a Facial-Video Digital Hydration Biomarker Score for Tracking Hydration State Transitions in a Real-World Fasting Model

cs.CV ·2026-11-11 ·Yudara Kularathne, D. M. J. Prathapa, Thanveer Ahamed, Janindu Athukorala, Thisara Perera
unusual similarity 0.81
Abstract · 12 pages, 6 tables, 5 figures

Hydration influences physiology and daily function, yet repeated practical measurement in everyday settings remains limited. We present initial real-world evidence that a facial-video lifestyle digital biomarker score can track the direction of hydration state transitions. Using Ramadan fasting as a model of prolonged fluid abstinence, we assessed whether the score tracks the transition between the fasting (pre-drink) state and the rehydrated (post-drink) state across three validation layers. In the primary cohort (104 participants, 208 videos), the score increased from a mean of 36.6 in the fasting (pre-drink) state to 70.6 in the rehydrated (post-drink) state (change = +33.9, 95% CI [+30.7, +37.1], p < 0.001, Cohen's d = 2.03), with 102 of 104 participants (98.1%) showing an upward shift. In a nested body-weight subgroup (20 participants), body weight increased by +0.74 kg after fluid intake (p < 0.001), confirming fluid uptake and providing supportive physical anchoring. In a nested serum osmolality subgroup (10 participants), osmolality decreased by -5.1 mOsm/kg (p < 0.001), with all post-drink values within the normal clinical range, providing exploratory biological support. An exploratory secondary comparison of water versus electrolyte rehydration showed no statistically significant difference in short-term score change (p = 0.247). This study does not establish a clinical diagnostic test for dehydration. Rather, these findings support the score as a lifestyle digital biomarker for tracking the direction of hydration state change in real-world settings.

0.27

It's All in the Way You Say It: The Role of Information Representation in LLM-Based Glycemic-Event Prediction

cs.AI ·2026-09-08 ·Andrea Apicella, Pasquale Arpaia, Matteo Orefice, Andrea Pollastro, Roberto Prevete
similarity 0.45
Abstract · Submitted to a journal for peer-review

Large Language Models (LLMs) are increasingly being investigated for physiological time-series prediction, yet their effectiveness may depend not only on the model itself, but also on how physiological information is represented and presented at inference time. This study investigates prompt-based general-purpose LLMs for postprandial hyperglycemia and hypoglycemia prediction in individuals with type 1 diabetes. Using the OhioT1DM dataset, we evaluate multiple open-weight LLMs under zero-shot and few-shot inference across prediction horizons of 30, 60, and 90 minutes. The analysis varies both the textual representation of the available physiological information and the amount of information exposed to the model, ranging from glucose observations alone to derived descriptors and additional contextual variables related to insulin, meals, carbohydrates, and physical activity. Performance is compared with conventional patient-specific supervised models and with Gluco-LLM, a language-model-based architecture explicitly adapted to glucose time-series forecasting. Results show a marked task-dependent behavior. Conventional supervised models achieve the strongest performance for hyperglycemia prediction, whereas the best observed prompt-based LLM configurations improve performance for hypoglycemia across all investigated horizons. The effectiveness of prompt-based inference is also strongly influenced by how physiological information is represented, while providing additional contextual information does not lead to a systematic improvement. Overall, these findings highlight physiological information representation as a central design factor in prompt-based LLM approaches to glycemic-event prediction.

0.35

Sensitivity-driven Personalization of a Glucoregulatory Model for Digital Twin Therapeutics in Type 1 Diabetes

eess.SY ·2026-09-25 ·Clara Escorihuela-Altaba, Vihangkumar V. Naik, Eleonora Manzoni, Jose Garcia-Tirado
similarity 0.44
Abstract

Digital twins are increasingly used in diabetes research, but reproducing individual glucose dynamics requires accurate identification of glucoregulatory model parameters. Traditional sensitivity analysis can identify influential parameters, yet a ranking based on limited conditions may miss parameters that matter during specific disturbances or for particular individuals. We therefore examine both the magnitude and timing of parameter influence across dynamic input-output conditions and assess whether a common ranking holds across participants. We analyze the Hovorka glucoregulatory model using data from 192 participants receiving automated insulin delivery therapy in the Type 1 Diabetes and Exercise Initiative dataset. We extend Sobol sensitivity analysis to time series and rank parameter influence under four conditions: full-day profiles, isolated meal disturbances, insulin bolus injections, and postprandial responses. We combine the condition-specific results into a global ranking and use it to select parameters for participant-specific identification. Compared with population parameters, identification restricted to the sensitivity-derived subset reduces the root mean square error of 60-minute glucose predictions by 60%, to approximately 31 mg/dL. These findings suggest that a global ranking can capture parameter influence across individuals and dynamic conditions. By narrowing the parameters requiring identification, this approach reduces computational cost and could accelerate the development of personalized diabetes digital twins.

0.20

Does Lifestyle Information Improve Hypertension Prediction? A Leakage-Controlled Evaluation on NHANES

cs.LG ·2026-11-14 ·Uriel Benymon
top venuecode/data similarity 0.43
Abstract · Accepted to the Machine Learning for Health (ML4H) 2026 Symposium, Findings Track. Code: https://github.com/urielbenymon/nhanes-lifestyle-hy…

Does readily available lifestyle information improve machine-learning prediction of hypertension beyond routine demographic and anthropometric data? On NHANES 2017-March 2020, five model families (Logistic Regression, Random Forest, Gradient Boosting, Bagged Decision Trees, and XGBoost) were evaluated with fold-local preprocessing and paired bootstrap confidence intervals. Adding physical activity, alcohol use, smoking, and sleep information showed no consistent detectable improvement in held-out discrimination: every paired ROC-AUC confidence interval included zero, including under a stricter measured-blood-pressure phenotype and without synthetic oversampling. Mean cross-model SHAP rank agreement fell from 0.873 to 0.806 over all encoded columns, but this decline was largely attenuated over the 19 baseline columns shared by both arms (0.873 vs. 0.863), and likewise under both robustness checks; attribution-agreement comparisons across feature sets of different sizes therefore require a matched comparison space. In exploratory analysis of untreated adults (measured-blood-pressure outcome), all five models showed small positive differences, two with unadjusted intervals excluding zero, meriting confirmation. These results do not imply that lifestyle factors are clinically unimportant; within this cohort, the evaluated lifestyle block added little incremental discrimination beyond an already-informative baseline.

0.48

Video-Based Palm-Vein Authentication under Challenging Conditions

cs.CV ·2026-09-02 ·Xiaofeng Yan, Kechen Liu, Abhilash Venkatesh, Cathy Zhang, Xia Zhou +1 more
benchmarkdatasetcode/data similarity 0.43
Abstract

Palm-vein biometrics are increasingly used for secure, contactless authentication. Yet real-world deployment exposes them to surface noise (sweat, dirt), illumination and motion variation, and temperature-driven changes in vascular visibility, which remain underexplored for lack of data captured under such conditions. To study these effects, we introduce the Columbia University Palm-vein (CUP) dataset, to our knowledge the first public video-based palm-vein dataset. CUP records every palm under four surface conditions (a clean baseline, warm, wet, and dirty) and pairs each subject with physiological and demographic metadata. On it we benchmark twenty-one recognizers spanning static, video, and multi-frame aggregation architectures. Models that verify reliably on clean palms lose most of their accuracy on dirty ones, and the mean equal error rate (EER) roughly quadruples. We recover much of that robustness along both axes of the capture. Temporally, a consensus over the few frames the sensor already returns cancels transient corruption; spatially, a test-time matcher that adds no learned parameters fuses the global cosine with a saliency-steered region-level optimal transport that routes the comparison around corrupted regions. The full design leads on every surface of CUP in EER, TAR@FAR=0.01, and Rank-1, at 4.3M parameters and 3.1 GFLOPs, a fraction of the video models' cost. Attached to four frozen state-of-the-art backbones it cuts their mean EER by 29-37% without retraining, and on four public single-image datasets the regional matching alone still helps. A preliminary audit across ten demographic and physiological traits finds two warm-condition gaps, along body water and gender, that survive multiple-comparison correction. CUP will be released for non-commercial research use at https://github.com/MobileX-CU/CUP_v1 upon publication.

0.40

PPG-Bench: A Unified Benchmark for PPG Foundation Models

cs.LG ·2026-10-09 ·Arvasu Kulkarni, Mahir Jain, Aditya Ray Mishra, Sandeep Singh, Siddharth Panwar
benchmarkcode/data similarity 0.43
Abstract

Photoplethysmography (PPG) is increasingly recorded by wearable and clinical devices at enormous scale, and a growing number of PPG foundation models (FMs) have been developed to compute reusable representations for various downstream tasks. These models are difficult to compare: different evaluations use different datasets, task definitions, preprocessing, downstream heads, hyperparameter tuning, and baselines. We present PPG-Bench, a unifying open-source benchmark evaluating five public PPG FMs across nine open-access datasets and 26 tasks spanning cardiovascular state estimation, activity, sleep, screening, and identification. We evaluate models under four downstream regimes of increasing adaptability (linear probing, random forests, frozen MLP probes, and end-to-end finetuning), with model-specific hyperparameter optimization and subject-disjoint cross-validation. We also evaluate against three controls: random/constant baseline, a deterministic pulse-rate-variability (PRV) feature set, and a generic time-series FM (MOMENT). Across all 68 task-regime combinations, 35.3% show no meaningful FM advantage over the random/constant baseline, and in 83.8% no PPG-specific FM outperforms both PRV and MOMENT. We also find that added downstream head capacity generally improves performance, but can cause significant degradation if the model is performing at chance/constant level. Current PPG FMs therefore cannot yet claim to provide generalised and transferrable representations of PPG signals, and future evaluation in this field should include checks against simple, non-learned controls. Code for the benchmark and instructions to evaluate more models can be found here - https://github.com/mannas-ai/ppg-bench.

0.31

Using Machine Learning to Investigate Predictors of Fasting Blood Glucose: Insights into Circadian Timing and Age Interactions

cs.LG ·2026-09-26 ·Viktoriya Bu-Dager, Silvia Cirstea
similarity 0.42
Abstract · 25 pages, 10 figures, 11 tables

Impaired glucose regulation is a major contributor to metabolic dysfunction and type 2 diabetes. This study developed an interpretable machine-learning framework to predict log-transformed fasting blood glucose using metabolic, hormonal, lifestyle, demographic, nutritional, and circadian variables from the National Health and Nutrition Examination Survey 2017--2020 pre-pandemic dataset. After merging multiple NHANES sub-datasets, data processing used a leakage-resistant pipeline in which imputation, scaling, and one-hot encoding were performed only after dataset splitting and within training folds. Elastic Net, LASSO, and XGBoost models were evaluated using 94 candidate predictors and engineered circadian interaction terms. Performance was assessed using mean absolute error, root mean squared error, coefficient of determination, calibration, and Shapley Additive Explanations. The final interaction-augmented XGBoost model achieved strong performance on the independent test set, with a mean absolute error of 0.0804, a root mean squared error of 0.1148, and a coefficient of determination of 0.7761, using 10 predictors. Glycohemoglobin was the dominant predictor, followed by insulin, diabetes diagnosis, gamma-glutamyl transferase, age, race, and gender. Among the engineered interaction terms, sleep midpoint multiplied by age was consistently retained in repeated random-split analyses, although its contribution remained modest relative to dominant glycaemic predictors. These findings support further investigation of circadian-age interactions in metabolic health.

0.25

Tracking Human Daily Cognitive Activity from EEG and Biometric Data

cs.HC ·2026-10-02 ·Alina Gutoreva, Zhaniya Omar
published similarity 0.42
Abstract

Understanding human cognitive activity in everyday life remains challenging due to the dynamic, context-dependent, and multimodal nature of cognition. Laboratory-based studies often fail to capture real-world cognitive processes, while single-modality approaches provide only partial insight into cognitive states. Advances in wearable sensing now enable the collection of heterogeneous data streams for a more comprehensive view of daily cognition. This paper presents a multimodal framework for tracking human cognitive activity using electroencephalography (EEG), wearable physiological signals, behavioral context, and self-reported measures. A preliminary pilot study was conducted with observational data from three participants (N = 3) over 280 annotated 10-minute intervals spanning nine activity domains across two weeks. Results reveal consistent temporal patterns, including a discernible mid-day decrease in motivation and energy at 13:00, followed by afternoon recovery. Work and IADLs yielded the highest flow state rates (51% and 50%), while ADLs produced the lowest (15%). Motivation correlated strongly with arousal (r = 0.78) and attention (r = 0.74), whereas perceived stress showed a weaker negative relationship (r = -0.33). A linear regression model predicting motivation from arousal, attention, energy, and stress achieved R2 = 0.76 (MAE = 9.84, RMSE = 12.85). Lag-based analysis indicates that prior energy levels positively predict subsequent motivation, confirming temporal dependencies in cognitive dynamics. These findings demonstrate the feasibility of multimodal cognitive activity analysis in real-world environments and highlight the importance of integrating physiological and behavioral indicators. The proposed framework provides a foundation for future large-scale multimodal systems and applied intelligent solutions.

0.22