CS Paper Radar

Quantum kernels on breast data: concentration, surrogates, and two ways an advantage gets manufactured

Rana Saad, Achraf Toufah, Moulay Youssef El Hafidi

cs.LG quant-ph ·submitted 2026-11-24 16:46 UTC · v1

Abstract

Quantum-kernel advantage claims on breast data are usually a single number: one quantum arm, one comparator, one test split. We asked what that number measures once the full comparator set and selection history are visible. We report three active benchmarks, all exact classical statevector simulations of 8-qubit fidelity kernels with no quantum component in the inference path: a sample-efficiency sweep on Wisconsin Diagnostic Breast Cancer at ten training-set sizes; raw-versus-processed arms on 1,200 M-SYNTH simulated mammograms with a matched closed-form dequantisation surrogate, five classical methods at the same input and eleven kernel families; and a 30-seed selection-inflation measurement on BreastMNIST. A CMMD D1 clinical arm is withdrawn as a result arm because its frozen splits leak the label through patient serial order, a defect reported in a separate study; it is retained only as a worked example. All three active arms are negative. On M-SYNTH raw an apparent +0.1736 (p = 5.2e-06) against a tuned RBF-SVM falls to +0.0019 (p = 0.937) against a random forest at the same input, and a Laplacian kernel wins on validation. On WDBC, with model selection confined to training data, the quantum kernel is below the selected classical arm at every training-set size, with 2 of 200 paired subsamples ahead. Best-of-30 seed selection adds +0.0210 on BreastMNIST. One result does not fit: at bandwidth 2pi the matched closed-form Gaussian surrogate failed to reproduce the M-SYNTH raw kernel (0.5410 against 0.7045, p = 6.3e-06). Comparator choice and selection each produce effects larger than any quantum-classical difference we measured; we give a reporting standard that removes both.

Comment
17 pages, 4 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Matched but Not Better: An Equivalence-Tested Benchmark of Quantum Machine Learning on Six Clinical Datasets and the QML-Health-READY Reporting Framework

cs.LG ·2026-11-03 ·Mohammed Siraj B, Gousia Habib, Ruban S
benchmark similarity 0.71
Abstract

Background: Quantum machine learning (QML) is promoted for clinical prediction, but comparisons with classical models are rarely paired or tested for equivalence. Methods: We compared a quantum-kernel support vector machine (QSVM; 4 qubits, tuned bandwidth) and a variational quantum classifier (VQC) with five tuned classical models across six public clinical datasets. All models used identical four-component inputs and 25 cross-validation splits. Paired AUROC differences were assessed using a corrected resampled t-test, Holm-adjusted equivalence tests (margins: +/-0.02 and +/-0.05), and random-effects pooling. Ablation, noise, finite-shot, and implementation-fault analyses were conducted. We propose QML-Health-READY, an eight-domain reporting framework. Results: Neither quantum model significantly outperformed any classical comparator. Pooled across datasets, QSVM differed from the kernel-matched radial basis function (RBF) SVM by -0.006 AUROC (95% CI: -0.017 to +0.004), equivalent to +/-0.02. VQC differed from the best classical model by -0.007 (95% CI: -0.019 to +0.004). QSVM was equivalent to RBF SVM within +/-0.05 in four of six datasets but was significantly worse than the best classical model on NHANES 2017-18 (-0.076). A classically trivial product-state kernel performed as well as the entangling kernel. With depolarizing noise (p = 0.01) and 1,024 shots per kernel entry, QSVM AUROC decreased by 0.054 (95% CI: 0.036 to 0.071). Untuned bandwidth produced near-chance AUROC (0.48-0.59). Conclusions: Correctly configured quantum classifiers approached but did not exceed tuned classical models. Finite-shot estimation, rather than gate noise, was their main practical cost, while configuration errors could reverse conclusions. QML-Health-READY defines reporting requirements for credible claims.

0.03

Empirical Evaluation of Quantum Kernel Methods for Classification: A Comparative Study with Classical Kernels

cs.LG quant-ph ·2026-10-30 ·Ronak Bhalgami
position similarity 0.71
Abstract

Quantum kernel methods are the most concrete near-term proposal for quantum machine learning on classical data, yet published benchmarks disagree on whether they outperform tuned classical kernels, and the disagreement cannot be resolved from the literature because the comparisons are not protocol-controlled. We argue that the obstacle is one of measurement, not theory: the usual setup fixes the quantum feature map's data scaling while grid-searching the classical kernel's hyperparameters, recomputes nothing per fold, and reports cost in simulator time. We therefore treat the comparison itself as the object of study and impose three controls. The bandwidth is tuned on the same grid budget as the classical $γ$, the kernel is recomputed inside every fold from fold-fitted preprocessing, and cost is counted in hardware circuit evaluations. On top of these we run a factorial design of 324 cells in which dimensionality, training size, class separability and data structure are explicit covariates, together with four standard datasets, a shots-versus-gate-noise ablation, and a cost sweep. The dominant effect we measure is not quantum: tuning the feature map's bandwidth is worth 0.120 accuracy on synthetic data and 0.339 on real data, exceeding every quantum-classical difference we observe. Tuned quantum kernels are then statistically indistinguishable from a tuned RBF on all four real datasets. The advantage on synthetic data is confined almost entirely to data generated by the feature map itself, and it shrinks with dimensionality (-0.0045 per qubit) while growing with sample size. Finite sampling costs an order of magnitude more accuracy than gate and readout noise, and a fidelity kernel needs $5\times10^{7}$ circuits at n = 10,000. Protocol variance is thus sufficient to explain the field's contradictory conclusions.

0.03

QuantumBoostNet: Hybrid Classical-Quantum Cardiac View Identification

cs.LG ·2026-08-27 ·Mihai Udrescu-Milosav, Stefan-Alexandru Jura, Mihai Udrescu, Gerhard-Paul Diller
similarity 0.69
Abstract · Additional classical baseline model; classical ablation; QPU inference

Accurate identification of the correct view or angle in cardiac ultrasound (echocardiogram) is critical for cardiologic imaging, precise anatomical interpretation, and reducing clinical errors. Most state-of-the-art classical models perform well on standard benchmarks but give suboptimal results in specialized medical imaging due to high noise levels. To address these challenges, this work proposes the hybrid classical-quantum architecture QuantumBoostNet, which combines a classical backbone with two heads: one classical and one quantum, a parametrized 10-qubit quantum circuit. The main contribution of this work is training in two stages, with an adaptive transition between heads controlled by a mixing parameter that monitors loss dynamics. Extensive experiments show that QuantumBoostNet outperforms the implemented baselines under matched training conditions. Statistically significant gains appear on FashionMNIST ($p_t=9.91\!\times\!10^{-6}$) and MNIST ($p_t=1.29\!\times\!10^{-5}$), with a less significant improvement on the echocardiography task ($p_t=0.0711$). The model also shows robustness to noise. These findings support continued development of hybrid classical-quantum models for specialized medical imaging applications.

0.24

Comparative Study of Quantum and Classical Machine Learning Models in Binary Classification

cs.LG quant-ph ·2026-09-20 ·Anand Kumar Mishra, Ramanuj Awasthi
similarity 0.68
Abstract

A potential path forward is Quantum Machine Learning (QML), which aims to leverage quantum computing in conjunction with classical machine learning to enhance computing efficiency and the expressiveness of models. In this paper, two different quantum classifiers - Variational Quantum Classifier (VQC) and Quantum Kernel Support Vector Machine (QSVM) - are compared with three classical classifiers as baseline classifiers - Logistic Regression, Support Vector Machine (SVM), and a Multi-Layer Perceptron (MLP) - on the Breast Cancer Wisconsin dataset. The quantum circuits were created in the PennyLane framework and simulated on a classical backend. However, in terms of accuracy, classical Logistic Regression performed better with an accuracy of 97.8%, classical SVM and QSVM with an accuracy of 95.6% each, although the Quantum VQC achieved a lower accuracy of 88.9% and had a recall of 100% for the benign class, though it correctly identified only 12 of the 17 malignant cases (a malignant-class recall of approximately 70.6%). The drawback of quantum models is the higher training time; however, since the quantum circuit needs to be classically simulated, the quantum SVM took 23.29 seconds compared to less than 0.01 seconds for the classical linear models. These results indicate that for small structured datasets, classifiers based on quantum computing have not yet surpassed well-tuned classical counterparts. In some respects (e.g., benign-class recall), they perform competitively, though not on malignant-class recall, where the VQC in particular performed worse than the classical baselines, which is worth further investigation on real quantum computers.

0.16

Quantum Kernel Estimation for the Discovery of Early Lung Cancer Detection

cs.LG cs.AIq-bio.QM ·2026-08-19 ·Hamed Javidi, Alex Zajichek, Hakan Doga, Laxmi Parida, Filippo Utro +1 more
published similarity 0.67
Abstract · Accepted at the CIBB 2026 conference (https://cibb2026.teralab.ai/)

Lung cancer screening with low-dose chest computed tomography reduces mortality, but its impact is limited by uptake, adherence, and management challenges. Blood-based cell-free DNA (cfDNA) biomarkers offer a complementary approach, although early detection remains difficult because of lung cancer heterogeneity and high-dimensional, nonlinear molecular signals. We evaluated quantum-classical hybrid machine learning for lung cancer detection using DNA fragmentomics and DNA methylation. After feature selection, models were trained using 20- and 40-feature subsets. Features were encoded into quantum Hilbert space using angle and dense-angle feature maps with multiple entanglement strategies. Fidelity-based quantum kernels were computed with exact statevector simulation and integrated with precomputed-kernel SVM and kernel-PCA logistic regression and compared with an SVM model trained on the original features. This framework enabled systematic evaluation of how encoding and entanglement design affect classification. Across repeated held-out evaluations, quantum-kernel models achieved competitive performance on both datasets. For fragmentomics, several 20-feature configurations improved AUC relative to a classical SVM baseline, suggesting effective capture of nonlinear cfDNA fragmentation structure. For methylation, the classical SVM achieved the highest AUC, although selected quantum models remained competitive and improved specificity in some cases. Increasing features from 20 to 40 did not consistently improve performance and often increased variability. Overall, these results support quantum kernel methods as a promising approach for cfDNA-based lung cancer detection.

0.35

QuPID: Quantum Parameter-Efficient Input-Dependent Retrieval Adaptation for Medical RAG

cs.AI cs.LG ·2026-09-27 ·Hyojun Ahn, Emily Jimin Roh, Soohyun Park, Walid Saad, Hyung-Chul Lee +1 more
similarity 0.62
Abstract · 42 pages, 18 figures, 33 tables

Fidelity-based quantum retrieval ranks candidates by the fidelity between query and archive states. Applying a shared input-independent unitary after fixed state encoding leaves that fidelity unchanged, so training the circuit cannot alter the ranking. Quantum parameter-efficient input-dependent retrieval adaptation (QuPID) repairs this by making the circuit input-dependent through data re-uploading and by comparing measurement readouts, vectors of local Pauli expectations, rather than states. The result is a small readout for adapting frozen image features to a local archive with limited data: training simulates the circuit classically, and inference runs on a GPU with fixed learned parameters. We characterize the class as a structured factorization of input-modulated quadratic feature maps, bound the frequency support of its re-uploading channel, and give a parameter-count generalization bound that motivates its small budget. Under a shared frozen backbone and a label-free protocol, QuPID's 60 parameters give higher precision-at-5 (P@5) on ChestX-ray14 and MURA than frozen medical encoders, and than adapters and low-rank adaptation (LoRA) with up to 5.25 million trainable parameters. On ChestX-ray14, the P@5 gain over the frozen encoder is +0.116, the lead over retuned adapters is widest at 512 adaptation examples (+0.040), and the full-budget margin over an equally compact classical rotation-plane head is +0.023 with a 95% interval excluding zero. Medical imaging is the primary testbed; the pattern recurs on two non-medical benchmarks, in report generation, and under simulated gate noise and finite-shot readout.

0.12

When do quantum views help? Complementary classical-quantum representations in multi-view fusion

cs.AI quant-ph ·2026-10-15 ·Azadeh Alavi, Fatemeh Kouchmeshki, Hossein Akhoundi, Yongli Re, Abdolrahman Alavi +1 more
benchmark similarity 0.62
Abstract · 35 pages, 4 figures

Recent studies have reported promising results from quantum machine learning in drug discovery, healthcare, materials science and cybersecurity. Research includes comparisons with classical machine learning algorithms and the development of sequential hybrid pipelines. We propose that fusion can improve prediction when classical and quantum representations capture complementary predictive relationships. Our classical-quantum multi-view framework preserves the full classical input alongside simulated quantum features. Concatenation and attention combine the views; single-view comparisons, replacement and masking controls assess both views' contributions. Controlled angular-polynomial experiments distinguish targets adequately represented by a single view from those that depend on complementary angular and polynomial relationships. For these mixed targets, fusion improves prediction by combining the relevant feature sets, while matched classical representations recover the same benefit, linking the improvement to their complementary predictive content. Controlled classification tests further show that gains depend on alignment between the chosen representation and the target, and on a suitable fusion rule. Benchmark validation shows improved mean predictive performance over classical baselines on Wine, Wisconsin Diagnostic Breast Cancer, three-class Fashion-MNIST and Steel Plates Faults within the evaluated protocols. Classical replacement and masking controls remain competitive, classical baselines lead on Digits and Covertype, and outcomes with missing or corrupted views depend on the available inputs. These findings support evaluating quantum representations for their complementary predictive contribution and matching the representation and fusion strategy to the target relationships.

0.26

Quantum data loading from the learned shared structure of real signals

cs.LG quant-phphysics.comp-ph ·2026-10-05 ·Pablo Herrero Gómez, Antonio Jimeno Morenilla, David Muñoz-Hernández, Higinio Mora Mora
similarity 0.62
Abstract

Preparing quantum states from classical data can cost more than the computation they serve; most loaders tailor a circuit to each input. Here we show that the signals of a real dataset share structure that can be learned once and reused. Our quantum-native loader learns a low-dimensional description of a dataset and prepares every signal with one fixed circuit set by a few numbers. Across seven views of five public datasets it meets the targets of the strongest structured loader at equal gate cost with several times fewer numbers per signal. These numbers can be inferred from a random subset: in a preregistered blind replication the subset needed to come within ten per cent of full-signal accuracy stayed constant within a prespecified margin as signals grew sixteenfold, whereas the structured loader needed ever more. It declines what it cannot represent, covering fewer cases than that baseline and no electrocardiogram.

0.29