CS Paper Radar

DDxBasis: Explaining Frozen Foundation Encoder-based Medical Classification by Exact Differential Diagnosis

Luojie Huang, Gregory N. McKay, Nicholas J. Durr

cs.CV q-bio.QM ·submitted 2026-11-24 19:46 UTC · v1
code/data

Abstract

In differential diagnosis (DDx), a clinician explains a diagnosis by the few findings that separate it from the alternatives. Medical image classifiers cannot yet explain themselves this way. Existing explanations are either faithful but spread over hundreds of concepts, or compact but leave part of each decision unexplained. We present DDxBasis, which explains a classifier on a frozen foundation encoder as a differential diagnosis in three steps. First, a concept bottleneck reads all patch tokens at every encoder layer using gated, second-order slot attention. A concept basis then regroups the concepts into two-pole axes, each a differential between groups of diagnoses. Finally, we read a differential diagnosis from each axis through the typical presentation of its poles, the pertinent findings of the case, and counterfactual edits of borderline cases. Across five medical datasets, DDxBasis is the most accurate frozen-encoder model and close to the best published domain-specific results. Because every concept adds its own evidence, its reproducible concept basis splits each decision exactly, at no cost in accuracy. Without ordered stage or concept labels, the axes recover cell lineages and rare subtypes, agree with dermatologists' structure annotations, and expose planted and real shortcuts.

Comment
Project page: durrlab.github.io/DDxBasis

Closest papers

Nearest neighbours by meaning across the whole index.

Learning from the Right Regions: Class-Conditioned Explanation Guidance for Medical Imaging

cs.CV cs.LG ·2026-10-17 ·Zubair Faruqui, Rahul Dubey
similarity 0.69
Abstract · Submitted to the Explainable and Trustworthy AI for Clinical Decision Support Systems Workshop, IEEE BIBM 2026

Deep neural networks can achieve strong predictive performance in medical imaging while relying on regions unrelated to the predicted finding. Explanation-guided learning can address this problem, but multi-label classification introduces a key challenge: multiple abnormalities may coexist in an image, requiring each prediction to align with its corresponding spatial evidence. We propose a class-conditioned explanation-guided learning framework that constructs a separate explanation for each positive class and penalizes evidence outside its class-specific annotated regions. We instantiate the framework using Gradient-weighted Class Activation Mapping (Grad-CAM) and evaluate it on 14 abnormalities using EfficientNet-B1, ViT-B/16, ViT-B/32, and Swin-B. Explanation guidance substantially improves annotation alignment across all architectures: All-Saliency Precision increases from 0.140 to 0.625, 0.052 to 0.551, 0.060 to 0.403, and 0.095 to 0.570, respectively. These improvements are accompanied by smaller, architecture-dependent changes in classification performance. Our results show that class-conditioned explanation guidance can substantially improve where multi-label classifiers concentrate their explanatory evidence while largely preserving predictive performance.

0.10

SAP-ViT: A Self-Attributing Patch Vision Transformer for Medical Image Classification

cs.AI ·2026-10-26 ·Wei Zhang, Wolfgang Nejdl, Ming Tang
similarity 0.68
Abstract

Vision Transformer (ViT) classifiers commonly rely on a global classification (CLS) token for image-level prediction, which is poorly aligned with local interpretability requirements in medical imaging. We propose SAP-ViT, a Self-Attributing Patch Vision Transformer that replaces CLS-based classification with direct aggregation of last-layer patch embeddings. This design makes class predictions decomposable into patch-level contributions as part of the forward pass. To encourage concise and readable evidence, SAP-ViT applies sparsity regularization to the patch-weight distribution. Since self-attention mixes information across patch tokens, we further introduce an input-space back-mapping mechanism to estimate which input patches contribute to influential output patch embeddings. We evaluate SAP-ViT qualitatively and quantitatively on multiple medical image classification datasets spanning different imaging modalities. The results show that SAP-ViT maintains strong classification performance while providing consistent and interpretable patch-level explanations across datasets. Ablation results further show that both sparsity regularization and the alignment component of input-space back-mapping contribute to the final explanation quality. Overall, SAP-ViT provides a favorable trade-off between predictive accuracy and interpretability for ViT-based medical image classification.

0.12

Beyond Explanation: Debugging Medical Imaging Models via Concept Intervention

cs.CV cs.LG ·2026-10-06 ·Samrajya Thapa, Daniel J. Quest, Timothy L. Kline, Carrie L. Langstraat, Emanuel C. Trabuco +1 more
published similarity 0.68
Abstract · Accepted at the 5th Workshop on Applications of Medical AI (AMAI), MICCAI 2026

Medical imaging models often operate as black boxes, limiting interpretability and systematic debugging. We introduce an easy-to-use, plug-and-play framework for concept-based interpretation and model refinement. By aligning a single-modality encoder to BioMedCLIP, we construct a Concept Bottleneck Model (CBM) that enables concept-level interventions. These interventions allow us to isolate causal versus spuriously correlated concepts, validate insights with domain experts, and generate counterfactual samples for targeted fine-tuning. We evaluate our framework on a Mayo Clinic ultrasound dataset and the CheXpert 5x200 chest X-ray dataset. Results demonstrate that concept intervention enables reliable model diagnosis while maintaining, and occasionally improving predictive performance via guided fine-tuning. Our findings highlight the practical value of this framework for controlled, interpretable refinement of clinical deep learning models.

0.19

SMILE: Self-Explainable Multimodal Information Bottleneck for Medical Diagnosis

cs.CV cs.LG ·2026-09-04 ·Yuqing Yang, Alexander Schmatz, Zhaozhao Ma, Changkyu Choi, Robert Jenssen +1 more
similarity 0.67
Abstract · 30 pages, 10 figures

Explainability is increasingly seen as a crucial requirement in AI-based medical diagnosis, particularly in safety-critical clinical decision-making. Most existing explainability methods in healthcare operate in a post-hoc manner and are predominantly designed for unimodal data, which limits their applicability in increasingly prevalent multimodal diagnostic settings. This paper addresses the problem of self-explainable multimodal diagnosis by formulating it within the information bottleneck (IB) framework. We propose a unified learning paradigm that jointly optimizes predictive performance and modality-specific explainability by identifying the most informative elements inside each modality that contribute to diagnostic decisions. To enable tractable and stable optimization, we employ a matrix-based Renyi's $α$-order entropy functional under the assumption of sufficiently expressive encoders. Extensive experiments on representative medical datasets spanning heterogeneous modalities demonstrate that the proposed method consistently achieves strong diagnostic performance, including an absolute accuracy improvement of 9.1 percentage points on the iCTCF dataset. Moreover, the learned explanations provide transparent and modality-aware insights into feature relevance, thereby improving both the explainability and generalization.

0.18

ReCAP: Sequential Concept Acquisition with Guarantees under Imperfect Concept Predictors

cs.CV ·2026-11-24 ·Md Nahiduzzaman, Steven Korevaar, Alireza Bab-Hadiashar, Ruwan Tennakoon
theory similarity 0.66
Abstract

Sequential concept acquisition enables interpretable diagnosis from a compact set of human-understandable findings. Such explanations are useful only if clinicians can trust them, yet most existing methods treat predicted concepts as correct, so a correct diagnosis can rest on incorrectly predicted evidence. We propose Reliable Concept Acquisition with Pruning (ReCAP), which reasons over what the concept predictor reports, including errors and abstentions, and replaces conditional information gain with a label-discriminating objective that separates cases requiring different diagnoses. We prove this objective adaptively monotone and adaptively submodular, yielding a (1-1/e) guarantee for greedy fixed-budget acquisition that degrades boundedly under learned estimates, and combine it with abstention-aware acquisition and diagnosis-preserving pruning to keep explanations short and reliable. Across five medical imaging datasets, ReCAP reduces the share of correct diagnoses supported by at least one incorrectly predicted concept from 27.1% to 9.6% relative to the strongest baseline, while using fewer than half as many concepts and achieving higher diagnostic accuracy.

0.26

Seeing Beyond the Lesion: Disease Recognition from Reactive CNS Tissue

eess.IV cs.CVq-bio.TO ·2026-09-02 ·Jan Schnorrenberg, Jan Ernsting, Enrico Küllenberg, Tim Hahn, Benjamin Risse +1 more
benchmark similarity 0.66
Abstract

Sampling error yields exclusively reactive, non-lesional brain parenchyma in a significant proportion of intracranial biopsies, leaving the underlying disease undiagnosed. We benchmark four pathology foundation models (UNI2-h, Virchow2, Prov-GigaPath, H-optimus-0) as frozen patch encoders within a shared attention-based multiple-instance learning framework using 245 whole-slide images from 186 patients with confirmed downstream diagnoses. We first show that coarse disease-category prediction can be reproduced largely from slide size alone. After restricting classification to three finer diagnostic distinctions within common tissue categories, this confound no longer explains performance, yet disease labels remain predictable above chance under permutation testing (p $\le 10^{-4}$ throughout). Surprisingly, performance is statistically indistinguishable across all foundation-model encoders, suggesting that recovering these weak morphological signatures is not limited by current patch representations. Signed instance-contribution maps and expert review further test whether predictive evidence localizes to reactive parenchyma rather than sampling-induced bias like blood introduced during tissue sampling. These results position acquisition-shortcut auditing via a provenance-only baseline as a necessary control in computational-pathology benchmarks, and show, once that confound is removed, that weakly supervised models still recover disease signal from tissue conventionally regarded as non-diagnostic.

0.23

MedReaMM: Evaluating Large Multimodal Models on Expert-Level Clinical Diagnostic Synthesis

cs.CV ·2026-08-23 ·Lai Wei, Yuchao Chen, Zhenbiao Cao, Xiaojin Zhang, Zhongyu Wei +3 more
top venuebenchmark similarity 0.64
Abstract

The application of Large Language Models (LLMs) to diagnostic decision-making has garnered growing interest. However, existing benchmarks largely focus on textual reasoning or isolated visual question-answering (VQA) tasks, lacking holistic integration of clinical narratives and medical imaging, and thus failing to assess the multimodal diagnostic synthesis capability central to expert clinical judgment. To bridge this gap, we introduce MedReaMM, a benchmark specifically designed to evaluate models' ability to synthesize heterogeneous clinical evidence consisting of detailed patient histories alongside multiple medical images into accurate differential diagnoses under a complete-information paradigm. Constructed from case reports sourced from top-tier medical journals and curated clinical case databases, MedReaMM comprises 625 expert-validated cases with an average of 2.79 medical images per case and a total of 1,042 standardized diagnoses annotated with ICD-11 codes. These cases predominantly represent rare, atypical, or multi-system presentations that demand expert-level evidence integration beyond routine pattern recognition. We evaluate 23 Large Multimodal Models (LMMs) and find that most achieve diagnostic accuracy scores below 50%, underscoring a substantial gap in multimodal diagnostic synthesis capability. Further analysis reveals that medical knowledge proficiency, medical image understanding, and evidence integration are all highly correlated with diagnostic performance.

0.40

MedCORE: Criteria-Grounded Clinical Reasoning for Interpretable Medical Image Diagnosis

cs.CV cs.AI ·2026-10-06 ·Asim Khan, Samee Ullah Khan, Dwarikanath Mahapatra
similarity 0.64
Abstract · 16 pages, 4 figures, conference

Clinical diagnosis is inherently a structured reasoning process, yet existing deep learning models often bypass this structure by mapping image features directly to disease labels without explicitly interrogating the morphological and textural criteria that clinicians systematically evaluate. This limits diagnostic transparency and may compromise safe clinical deployment. We present MedCORE (Medical Criteria-Oriented Reasoning and Evidence), a structured diagnostic framework that operationalizes clinical reasoning within a vision-language architecture. For each input image, MedCORE decomposes the diagnostic process into clinically defined criteria, spatially localizes each criterion to diagnostically relevant image regions, encodes evidence through multi-scale representations that capture macro-structural and micro-textural pathological characteristics, and refines criterion representations using a Graph Attention Network that explicitly models inter-criteria dependencies. Criterion representations are further aligned with clinical text descriptors, reinforced through class-wise visual prototypes, and aggregated using uncertainty-calibrated weighting that proportionally discounts low-confidence diagnostic evidence. MedCORE is validated across three clinically heterogeneous imaging modalities, including dermoscopic lesion classification on ISIC 2018, breast ultrasound lesion characterization on BUSI, and diabetic retinopathy grading on IDRiD. Quantitatively, MedCORE achieves 89.2% accuracy, 85.7% macro-F1, and 96.4% AUC on ISIC 2018; 96.1% accuracy, 95.2% macro-F1, and 98.4% AUC on BUSI; and 84.3% accuracy, 80.2% macro-F1, and 92.8% AUC on IDRiD. These results demonstrate consistent improvements over strong CNN, transformer, biomedical vision-language, concept-based, and prototype-based baselines.

0.20