CS Paper Radar

Weekly top 50 · cs.MS

2026-W38 Sep 14 – Sep 20, 2026

Ranked from 4,297 papers submitted on 7 days.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works
1

Implementation Note 2: Approximating a Smooth Three-Dimensional Function on a Coarse Lattice

cs.GR cs.MS ·2026-09-20 ·Dennis Luxen
unusual
Abstract

A smooth 3D function can be efficiently and accurately approximated by a 3D lookup table of significantly lower resolution combined with tetrahedral interpolation. The function is sampled once on a coarse grid in a preprocessing step. For each input, the enclosing grid cube is located, one of the 6 tetrahedra in this cube is selected, and the values at its 4 corners are combined by a weighted sum. For RGB to CMYK color conversion, a particularly frequent application of this, a table with $n = 16$ cells per axis ($17^3$ nodes, 16-bit values) requires 38\,KiB. A full 8-bit table requires 64\,MiB. As shown in an experimental evaluation, the mean error of the $n = 16$ table is 0.08\,\% ink per channel. For 8-bit input, the lookup uses integer arithmetic only (Section~\ref{sec:integer}). It requires no floating point and no division, and all intermediate values fit in 32 bits. Floating point is needed only to build the table, once and offline. The integer result differs from tetrahedral interpolation with exact fractions by at most 1 unit of the 16-bit output, and white and black are reproduced exactly. This makes the approach suitable for low-power devices and real-time applications where computational resources are limited.

0.29
2

Verification of PETSc with CIVL using LLM-generated ACSL contracts and deterministic driver generation

cs.CL cs.MScs.PLcs.SE ·2026-09-16 ·Hansol Suh, Jan Hückelheim, Stephen Siegel
Abstract

Parallel numerical libraries such as PETSc are widely used in science and engineering applications where wrong results can have costly consequences. Despite this, numerical libraries are rarely formally verified. One of the challenges is the need for an expert to hand-write a specification and manually apply a verification tool, often requiring the development of a harness or driver, all of which can contain additional bugs that lead to false positives or false negatives during verification. With recent advancements in large language models (LLMs), it is tempting to generate such drivers and reference models automatically, but one-shot generation based on a simple prompt is brittle and leads to additional unverified code that needs to be audited. In this paper, we present an approach to use LLMs in a limited setting to generate a small, human-certifiable ACSL contract from the function's documentation, combined with a deterministic toolchain that supports a restricted ACSL profile and generates a driver that uses the CIVL verifier to check the implementation against the contract and, when available, an existing reference model. We demonstrate the pipeline end-to-end on three PETSc functions: MatAXPY (reference model already exists), MatAYPX (no reference model, so the certified contract is the sole oracle), and the non-compressing mode of MatFilter (no reference model, with more complex, conditional behavior). With this pipeline, we were able to discover a bug in PETSc's MatAYPX function that was previously undiscovered and had been present in the code since 1997.

0.25
3

ARTA: Graph Combinatorial Optimization for Robust Interbeat Interval Estimation from Wearable Electrocardiogram Signals

eess.SP cs.CLcs.MS ·2026-09-15 ·Shovito Barua Soumma, Asiful Arefeen, Hassan Ghasemzadeh
Abstract · Under Review

Accurate heart rate (HR) and interbeat interval (IBI) estimation from wearable electrocardiogram (ECG) is essential for continuous physiological monitoring, but motion artifacts can create false QRS-like peaks and obscure true R-peaks. Conventional detectors and local interval-repair rules process detections independently and may become unreliable when several consecutive beats are corrupted. We present ARTA (Artifact-Robust Temporal Alignment), a graph-based combinatorial framework that estimates the heartbeat sequence through constrained temporal optimization. ARTA combines candidates from multiple ECG detectors, represents them as nodes in a directed acyclic graph and connects candidates through physiologically plausible RR intervals. Candidate confidence uses detector agreement and local ECG quality, while history-dependent transition costs capture recent IBI consistency and a soft heart-rate prior. Beam-search dynamic programming selects a coherent low-cost path across the recording, suppressing false detections and recovering missed beats when plausible auxiliary candidates are available. On the IEEE Signal Processing Cup exercise dataset with electrode-motion artifacts from -2 to 12 dB, ARTA achieved an HR mean absolute error of 1.79 beats per minute, 54% lower than the strongest single-detector baseline, with 92.38% of windows within +/-5 beats per minute, an R-peak F1 score of 0.95, and an IBI mean absolute error of 6.52 ms. Cross-dataset evaluation on the European ST-T Database further assessed transfer to long clinical ambulatory recordings and a label-free reliability analysis examined conditional performance without using reference annotations for segment selection. ARTA is single-channel, training-free, interpretable and computationally lightweight, operating approximately 27 times faster than real time with peak memory below 2.1 MB in a single-thread CPU simulation.

0.17