CS Paper Radar

Daily listing

2026-10-07 · eess.AS

22 papers first submitted this day (UTC) in eess.AS — Audio and Speech Processing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

AI & Machine Learning 2

Controlled Acquisition and Abstention in Three-Channel Score Conflicts

cs.LG cs.MMeess.AS ·2026-10-07 ·Mengzhe Geng
benchmark
Abstract

When audio, video, and text disagree, accuracy alone does not show whether to acquire another source or abstain. We study these choices in a controlled three-score benchmark: a policy observes two signed scores, may request the third at a cost, and can abstain. The primary reward is mechanism-specific: abstention is correct only for one designated ambiguity mechanism and is penalized under mixed corruption. Matched controls show that a threshold policy matches always-request decisions with fewer requests; its advantage over always-answer fusion depends on the reward assigned to that ambiguity. On a partially held-out synthetic split, the threshold policy reaches 0.789 +/- 0.006 targeted decision accuracy and 0.481 +/- 0.014 utility across 83 seeds. A three-score majority reference reaches 0.626 +/- 0.008 and 0.252 +/- 0.016, but uses more information. In a matched-budget test, a train-only value selector improves utility over no-query and matched-random policies at 10% and 25% budgets, while pair uncertainty has higher utility at every budget. At 50% and 63.7% budgets, the selector lowers utility despite slightly higher non-ambiguous accuracy. If all abstentions are scored incorrect, majority outranks the threshold policy in utility. At a central temporal setting, full-trace controls match the neural models while position perturbations separate them. On held-out-actor emotion clips, eight-frame fusion has opposite-signed accuracy differences for two encoder pairs, with both actor intervals containing zero; matched-request routing gains are small and uncertain. These results separate full-modality accuracy from pre-request selection value and show that selection value depends on budget and the observed-pair ranking.

0.26

SECURE-AI: Multi-Signal Uncertainty Quantification for Trustworthy Acoustic Cough Detection

cs.LG cs.AIcs.SDeess.AS ·2026-10-07 ·Sejal Solkhan, Feiya Xiang, Mayur Sanap, Geet Khatri, Edgar Lobaton
Abstract

Acoustic models for cough detection achieve high accuracy on curated benchmarks but fail silently in deployment, where speech, environmental noise, and audio unlike the training data induce confident misclassifications. In health monitoring, a confidently wrong prediction is worse than no answer at all. We present SECURE-AI (Self-aware Estimation of Cough Uncertainty for Reliable Evaluation of AI), a multi-signal uncertainty quantification framework that wraps a frozen MobileNetV3 cough classifier and estimates when its predictions should not be trusted, combining Monte Carlo Dropout, Temperature Scaling, and Mahalanobis distance in the embedding space. On a held-out split of 12,161 Coswara recordings, the probability-space methods are individually insufficient: Monte Carlo Dropout assigns lower uncertainty to incorrect than to correct predictions, and temperature scaling improves calibration but not discrimination. The strongest signal is embedding-space distance: Mahalanobis distance separates true positives from false positives (means 44.7 versus 63.4; Cohen's $d = 0.94$; AUROC 0.86) and, among predicted non-coughs, false negatives from true negatives (AUROC 0.82), so the same signal can flag both false alarms and missed coughs. At a descriptive operating point selected from labeled test data, retaining 90 percent of true-positive detections removes about two-thirds of false positives and raises precision from 59.9 to roughly 80 percent. A rejection threshold tuned on one split does not transfer to another (validation F1 of 82 percent falls to 34 percent on test), so we report threshold-independent AUROC as the main measure. An error taxonomy shows that failures are systematic, with most false positives related to speech. The pipeline runs on Raspberry Pi hardware costing 30 to 90 US dollars. Probabilistic calibration alone is thus inadequate for reliable cough detection.

0.16