CS Paper Radar

SECURE-AI: Multi-Signal Uncertainty Quantification for Trustworthy Acoustic Cough Detection

Sejal Solkhan, Feiya Xiang, Mayur Sanap, Geet Khatri, Edgar Lobaton

cs.LG cs.AIcs.SDeess.AS ·submitted 2026-10-07 22:02 UTC · v1

Abstract

Acoustic models for cough detection achieve high accuracy on curated benchmarks but fail silently in deployment, where speech, environmental noise, and audio unlike the training data induce confident misclassifications. In health monitoring, a confidently wrong prediction is worse than no answer at all. We present SECURE-AI (Self-aware Estimation of Cough Uncertainty for Reliable Evaluation of AI), a multi-signal uncertainty quantification framework that wraps a frozen MobileNetV3 cough classifier and estimates when its predictions should not be trusted, combining Monte Carlo Dropout, Temperature Scaling, and Mahalanobis distance in the embedding space. On a held-out split of 12,161 Coswara recordings, the probability-space methods are individually insufficient: Monte Carlo Dropout assigns lower uncertainty to incorrect than to correct predictions, and temperature scaling improves calibration but not discrimination. The strongest signal is embedding-space distance: Mahalanobis distance separates true positives from false positives (means 44.7 versus 63.4; Cohen's $d = 0.94$; AUROC 0.86) and, among predicted non-coughs, false negatives from true negatives (AUROC 0.82), so the same signal can flag both false alarms and missed coughs. At a descriptive operating point selected from labeled test data, retaining 90 percent of true-positive detections removes about two-thirds of false positives and raises precision from 59.9 to roughly 80 percent. A rejection threshold tuned on one split does not transfer to another (validation F1 of 82 percent falls to 34 percent on test), so we report threshold-independent AUROC as the main measure. An error taxonomy shows that failures are systematic, with most false positives related to speech. The pipeline runs on Raspberry Pi hardware costing 30 to 90 US dollars. Probabilistic calibration alone is thus inadequate for reliable cough detection.

Closest papers

Nearest neighbours by meaning across the whole index.

Why ML-based cough models do not generalize: a systematic cross-dataset evaluation for tuberculosis screening

eess.AS cs.AIcs.LGcs.SD+1 ·2026-08-26 ·Wensi Zhang, Tomas Teijeiro, Jérôme Thevenot, David Atienza
similarity 0.67
Abstract

Cough acoustics are promising for non-invasive tuberculosis (TB) screening, yet whether machine learning (ML) models capture disease-related acoustics or artifacts of data collection remains unresolved. We evaluated the cross-dataset generalizability of classical ML and deep learning (DL) cough-based TB classifiers across three independent datasets. Despite moderate within-dataset performance (ROC-AUC up to $0.755 \pm 0.056$), both pipelines fail to generalize, with external performance frequently below 0.6, indicating a possible limitation of the data. We further observed audio representations are organized by recording device and dataset rather than TB status, predicted TB probability tracks country-level prevalence in CODA, and device mismatch degrades transfer while device-diverse training improves it. Additionally, a clinical-variable baseline generalizes more consistently (ROC-AUC $0.655 - 0.711$), indicating acquisition-specific variability is a stronger driver of poor generalizability than population shift. High within-dataset performance is not enough. External validation is essential before cough-based TB models are clinically ready.

0.07

Listening for Airway Stenosis: A Foundation Model-Based Method for Rapid and Accessible Detection

cs.SD ·2026-09-14 ·Jean Groeninger, Zihao Zhao, Juliana de Castilhos, Sven Nebelung, Daniel Truhn
code/data similarity 0.62
Abstract · Jean Groeninger and Zihao Zhao contributed equally. Code is available at https://github.com/JeanGrng/listening-for-airway-stenosis

Airway stenosis can cause severe respiratory complications, yet its detection often relies on specialized examinations and medical imaging. This study explores the potential of acoustic AI for rapid and accessible airway stenosis detection using readily acquired patient voice recordings. We systematically investigate whether acoustic foundation models (AFMs) can extract acoustic representations associated with airway stenosis-related speech patterns. Experiments are conducted on a cohort of 748 participants from the Bridge2AI-Voice dataset, 134 with airway stenosis and 614 without. The best-performing model achieves an AUROC of 0.952 and an accuracy of 0.924 (means over five-fold cross-validation), highlighting the potential of AFMs to transfer beyond general-purpose speech applications to clinical diagnostic tasks. Further analysis reveals that the model primarily relies on connected-speech recordings rather than isolated acoustic tasks, such as sustained phonation and breathing. Overall, these results suggest that voice-based acoustic AI could complement existing diagnostic workflows by enabling rapid, low-burden, and widely accessible screening for airway stenosis.

0.43

Ensemble-Based Perceptual Audio Quality Assessment with Confidence Intervals

eess.AS cs.SD ·2026-10-05 ·Pablo M. Delgado, Andreas Brendel, Konstantin Schmidt, Jürgen Herre
similarity 0.59
Abstract · 5 Pages. 3 Figures. Submitted to 2027 IEEE International Conference on Acoustics, Speech, and Signal Processing

Objective audio quality metrics typically provide point estimates, whereas listening tests yield score distributions from which mean opinion scores (MOS), confidence intervals (CIs), and significance decisions are derived. We propose a lightweight intrusive metric that combines a PEAQ-style perceptual front-end (ITU-R BS.1387) with a bagging ensemble of regressors. Calibration with subjective data aligns ensemble outputs with listener scores. The resulting item-dependent score distributions enable uncertainty assessment, panel-size-matched CIs, and identification of less conclusive predictions. Calibration improves agreement with subjective distributions and CI coverage across all evaluated datasets while preserving MOS accuracy. Using only 11 fixed PEAQ features, low-capacity regressors, and public training data, the method performs comparably to more data-intensive end-to-end approaches. Its output can support uncertainty-aware assessment and target listening tests towards uncertain conditions. The distributions also enable approximate pairwise comparisons, but not yet reliable significance inference.

0.21

Leakage-aware acoustic drone detection: fusing hand-crafted and pretrained audio features in a stacking ensemble

cs.SD cs.LG ·2026-11-03 ·Zahid Iqbal
benchmarkhot direction similarity 0.58
Abstract

Small multirotor drones produce a characteristic acoustic signature, and microphones offer a low-cost way to detect them. High accuracies have been reported on public drone audio benchmarks, often with random clip-level splits of datasets built from a few long recordings and pieces of existing sound collections, so pieces of one source can appear in both training and test data. We study the binary task of the public DroneAudioDataset (11,704 one-second clips). Its 1,332 drone clips come from 257 five-second chunks of 7 recordings, and 96.4% of its non-drone clips are pieces of the 2,000 clips of the ESC-50 sound dataset. A grouped, source-disjoint protocol (five folds, three repeats) is compared with a random split. Each clip is described by 57 hand-crafted acoustic descriptors, reduced by a hybrid minimum-redundancy maximum-relevance and ReliefF selection or by NSGA-II multi-objective search, and by a 1024-dimensional embedding from the pretrained YAMNet network. Random Forest and XGBoost learners on both views form a stacking ensemble. Under the grouped protocol, the two-view stack reached a mean accuracy of 95.29% (SD 1.62 points over 15 test folds), a specificity of 98.29% and an area under the ROC curve of 0.990, and it correctly classified 98.78% of unseen ESC-50 source clips as non-drone. The random split overstated accuracy by 1.89 to 3.22 points for the four models. Adding YAMNet embeddings to the hand-crafted view raised accuracy by 1.11 points (higher in 12 of 15 folds). Hybrid selection matched the accuracy of all 44 baseline descriptors with 16 to 18 features, and NSGA-II retained 4 to 6 features at lower accuracy. The stack took 51.0 ms per clip on one CPU thread. Source-disjoint evaluation exposes the optimism of random splits and gives a reliable benchmark, and fusing hand-crafted with YAMNet features consistently improves detection in real time on one CPU thread.

0.30

SpiroPhonia: Non-Invasive Respiratory Health Assessment from Spontaneous Speech

cs.SD ·2026-09-15 ·Roksana Khanom, Shafia Supty, Nirupam Roy, Ashok Agrawala
top venuedatasethot direction similarity 0.58
Abstract · Accepted at Interspeech 2026, Sydney, Australia

Chronic Obstructive Pulmonary Disease (COPD) remains a major global health challenge, emphasizing the need for accessible and non-invasive detection. Since speech production is fundamentally linked to respiratory physiology, its disruptions can serve as indirect indicators of pulmonary impairment. This study introduces SpiroPhonia, a machine learning framework that leverages spontaneous speech for respiratory health assessment. We evaluated SpiroPhonia on a new dataset of 201 speakers (102 with COPD, 99 healthy controls). By integrating statistical analysis with recursive feature selection, we identified a compact set of discriminative speech markers. Our best model achieved 78% accuracy, 80% F1-score, and 87% AUC. This performance on spontaneous speech is competitive with methods using controlled laboratory recordings. Findings demonstrate that everyday speech encodes robust respiratory biomarkers, paving the way for continuous health monitoring via voice-enabled technologies.

0.65

Real-Validated UAV Audition Under Rotor Ego-Noise for Low-False-Alarm Human Detection

cs.CE ·2026-09-19 ·Junhao Wei, Haochen Li, Dexing Yao, Yanxiao Li, Yifu Zhao +5 more
benchmark similarity 0.57
Abstract

Detecting human acoustic cues from UAV-mounted microphones could support acoustic search and rescue, but rotor ego-noise often masks speech, cries, coughs, and other human sounds at extremely low SNRs. We study UAV human-audible-presence detection under this real operating constraint. Models are trained on a reproducible synthetic mixture pipeline built from public audio, but selected and evaluated on real DroneAudioSet recordings using a metadata-defined audibility filter, recording-grouped Dev/Test splits, and group-bootstrap confidence intervals. Our results show that synthetic accuracy is a weak and non-monotonic proxy for real UAV transfer: a from-scratch SE-ResNet appears competitive on synthetic mixtures but collapses on real ego-noise, while frozen audio foundation models and lightweight adapters transfer more reliably. We further evaluate a BEATs adapter family with rotor-aware conditioning and domain regularization. The Real-Dev-selected EgoRAP-DA configuration achieves the best locked-test low-false-alarm recall among the candidates, but its advantage over a vanilla adapter is not statistically significant under paired group bootstrap. The main contribution is therefore a real-validated benchmark and evaluation protocol showing that honest progress in UAV audition requires real, group-level validation rather than synthetic scores alone.

0.11

Unsupervised Data Drift Monitoring for Deployed Deepfake Speech Detectors

cs.SD cs.AIcs.CRcs.CV+1 ·2026-10-12 ·Lukáš Prokeš, Vojtěch Staněk, Anton Firc, Kamil Malinka
similarity 0.57
Abstract · Accepted at IEEE International Workshop on Information Forensics and Security (WIFS) 2026

Deepfake speech detectors are typically evaluated as binary classifiers on fixed benchmarks, but deployed systems face evolving attacks, codecs, speakers, and recording conditions, with labels unavailable during operation. This makes it difficult to know when a detector operates in familiar conditions and can be relied on. We propose an unsupervised drift monitor that operates on the internal embeddings of a deployed detector. The monitor compares each input against bona fide and spoof references using regularized Mahalanobis distances. These distances define trusted, ambiguous, and novel regions of the detector embedding space, allowing unfamiliar inputs to be routed for review. We evaluate the monitor on four modern detectors on three datasets. The monitor raises alerts for dataset mismatches and substantially reduces the security-critical case of accepting deepfakes at the cost of reduced automatic coverage. The results also show that drift affects both classes: bona fide recordings can move away from the training reference, increasing alert rates even in in-domain settings. Our findings suggest that deployed deepfake speech detectors should be treated not only as a binary classification, but also as a reliability problem.

0.21

Feature Scaling Beats Architecture Choice in Offline Respiratory Screening for Low-Resource Clinics

cs.LG cs.AIcs.SD ·2026-10-12 ·Abubakar Chilala, Cleophas Kadima, Innocent Anyaele, Victor Olufemi
similarity 0.57
Abstract

Deep models are the usual choice for respiratory sound classification, but in clinics without GPUs or connectivity that choice carries a cost. We compare classical and deep classifiers on a five-class respiratory-sound corpus of 1,211 clips (asthma, COPD, pneumonia, Bronchial, healthy) from 201 patient groups, with a 3.86:1 class imbalance, using pre-registered patient-grouped cross-validation (25 runs per configuration). An SVM over 30 summary features (MFCC, ZCR and RMS statistics) reaches macro recall 0.78 and 0.71 recall on the rarest class. A 1.13M-parameter convolutional recurrent network over log-Mel spectrograms reaches 0.75 to 0.77, and no difference between model families is resolved. The largest single effect we measure is a preprocessing effect rather than an architectural one. Standardizing the SVM's features, a routine step for RBF kernels, moves its macro recall from 0.51 to 0.78, a 27-point swing wider than any gap between model families here. Augmentation did not help: SMOTE, waveform augmentation and SpecAugment have no measurable effect. Latency does not separate the models (51 to 74 ms per clip on a CPU-only laptop), but the classical models avoid a 449 MB PyTorch runtime. Clip-level splits, which let a patient's recordings fall on both sides, inflate macro recall by 7.5 to 9.8 points. Recording source is strongly tied to label (Cramer's V = 0.65 between native sampling rate and class), and in an exploratory analysis clips recorded at a class's minority rate are mostly assigned to classes typical of that rate; we state this confound as the paper's main limitation.

0.13