CS Paper Radar

Feature Scaling Beats Architecture Choice in Offline Respiratory Screening for Low-Resource Clinics

Abubakar Chilala, Cleophas Kadima, Innocent Anyaele, Victor Olufemi

cs.LG cs.AIcs.SD ·submitted 2026-10-12 17:19 UTC · v1

Abstract

Deep models are the usual choice for respiratory sound classification, but in clinics without GPUs or connectivity that choice carries a cost. We compare classical and deep classifiers on a five-class respiratory-sound corpus of 1,211 clips (asthma, COPD, pneumonia, Bronchial, healthy) from 201 patient groups, with a 3.86:1 class imbalance, using pre-registered patient-grouped cross-validation (25 runs per configuration). An SVM over 30 summary features (MFCC, ZCR and RMS statistics) reaches macro recall 0.78 and 0.71 recall on the rarest class. A 1.13M-parameter convolutional recurrent network over log-Mel spectrograms reaches 0.75 to 0.77, and no difference between model families is resolved. The largest single effect we measure is a preprocessing effect rather than an architectural one. Standardizing the SVM's features, a routine step for RBF kernels, moves its macro recall from 0.51 to 0.78, a 27-point swing wider than any gap between model families here. Augmentation did not help: SMOTE, waveform augmentation and SpecAugment have no measurable effect. Latency does not separate the models (51 to 74 ms per clip on a CPU-only laptop), but the classical models avoid a 449 MB PyTorch runtime. Clip-level splits, which let a patient's recordings fall on both sides, inflate macro recall by 7.5 to 9.8 points. Recording source is strongly tied to label (Cramer's V = 0.65 between native sampling rate and class), and in an exploratory analysis clips recorded at a class's minority rate are mostly assigned to classes typical of that rate; we state this confound as the paper's main limitation.

Closest papers

Nearest neighbours by meaning across the whole index.

RespFocus: Learning Temporal Evidence for Weakly Supervised Respiratory Sound Classification

cs.LG cs.AI ·2026-10-11 ·Yi Tian, Xiaohuan Chen, Yufei tang, Xinyu Lin, Hongliang Li +3 more
similarity 0.72
Abstract · 9 pages, 5 figures,2 tables

Respiratory auscultation provides a low-cost means of assessing pulmonary function, yet transient crackles and sustained wheezes can be difficult to recognize in noisy clinical recordings. Conventional deep learning classifiers often operate as black boxes, offering limited insight into the temporal acoustic evidence supporting their predictions. We present RespFocus, a weakly supervised framework that uses multiple instance learning (MIL) to learn inspectable temporal evidence from cycle-level labels and integrate it into classification. We also introduce PedResp2026, a multicenter pediatric respiratory sound cohort collected in routine clinical environments with adjudicated cycle-level annotations. In classification experiments, RespFocus achieves four-class Scores of 69.55\% on public ICBHI 2017 and 72.91\% on PedResp2026. Evidence diagnostics and matched temporal interventions support the functional contribution of the learned evidence to model predictions. Together, these findings highlight RespFocus's potential as a tool for automated respiratory sound diagnosis.

0.30

Clinically Informed Acoustic-Aware Attribute Modeling for Respiratory Sound Classification

cs.SD ·2026-10-16 ·Xinhong Li, Li Xiao, Ziyang Chen, Yuhong Yang, Weiping Tu
similarity 0.69
Abstract · Accecpted by BIBM2026 regular paper

Automated respiratory sound classification (RSC) aims to identify normal and adventitious respiratory sounds, such as crackles and wheezes. Most existing methods formulate RSC as a flat four-class classification problem over norma, crackle, wheeze and both. However, unlike conventional classification tasks with semantically independent and mutually exclusive categories, the commonly used four-class RSC labels have a compositional structure and can be represented by two clinically meaningful sound attributes: crackle presence and wheeze presence. Existing flat classifiers do not explicitly exploit this structure, which may increase the learning burden by treating the four labels as independent targets. Meanwhile, crackles and wheezes exhibit distinct temporal characteristics, with sparse transient crackle events and sustained continuous wheeze patterns, making a single temporal aggregation strategy less suitable for modeling different adventitious sound evidence. To address these limitations, we propose an Acoustic-Aware Asymmetric Framework (AAAF) for RSC. AAAF reformulates four-class recognition as two sound-attribute detection tasks and recovers the final category through logical composition during inference. Built upon a pretrained BEATs encoder, AAAF employs branch-specific multi-layer fusion and asymmetric temporal aggregation to capture localized crackle evidence and sustained wheeze patterns. Auxiliary normal--abnormal supervision and a batch-adaptive dynamic loss are further introduced to improve global discrimination and robustness under imbalanced labels. Experiments on ICBHI and SPRSound demonstrate that AAAF improves overall RSC performance and generalizes across datasets, achieving a state-of-the-art four-class Score of 65.30% on ICBHI.

0.24

Why ML-based cough models do not generalize: a systematic cross-dataset evaluation for tuberculosis screening

eess.AS cs.AIcs.LGcs.SD+1 ·2026-08-26 ·Wensi Zhang, Tomas Teijeiro, Jérôme Thevenot, David Atienza
similarity 0.68
Abstract

Cough acoustics are promising for non-invasive tuberculosis (TB) screening, yet whether machine learning (ML) models capture disease-related acoustics or artifacts of data collection remains unresolved. We evaluated the cross-dataset generalizability of classical ML and deep learning (DL) cough-based TB classifiers across three independent datasets. Despite moderate within-dataset performance (ROC-AUC up to $0.755 \pm 0.056$), both pipelines fail to generalize, with external performance frequently below 0.6, indicating a possible limitation of the data. We further observed audio representations are organized by recording device and dataset rather than TB status, predicted TB probability tracks country-level prevalence in CODA, and device mismatch degrades transfer while device-diverse training improves it. Additionally, a clinical-variable baseline generalizes more consistently (ROC-AUC $0.655 - 0.711$), indicating acquisition-specific variability is a stronger driver of poor generalizability than population shift. High within-dataset performance is not enough. External validation is essential before cough-based TB models are clinically ready.

0.07

Listening for Airway Stenosis: A Foundation Model-Based Method for Rapid and Accessible Detection

cs.SD ·2026-09-14 ·Jean Groeninger, Zihao Zhao, Juliana de Castilhos, Sven Nebelung, Daniel Truhn
code/data similarity 0.68
Abstract · Jean Groeninger and Zihao Zhao contributed equally. Code is available at https://github.com/JeanGrng/listening-for-airway-stenosis

Airway stenosis can cause severe respiratory complications, yet its detection often relies on specialized examinations and medical imaging. This study explores the potential of acoustic AI for rapid and accessible airway stenosis detection using readily acquired patient voice recordings. We systematically investigate whether acoustic foundation models (AFMs) can extract acoustic representations associated with airway stenosis-related speech patterns. Experiments are conducted on a cohort of 748 participants from the Bridge2AI-Voice dataset, 134 with airway stenosis and 614 without. The best-performing model achieves an AUROC of 0.952 and an accuracy of 0.924 (means over five-fold cross-validation), highlighting the potential of AFMs to transfer beyond general-purpose speech applications to clinical diagnostic tasks. Further analysis reveals that the model primarily relies on connected-speech recordings rather than isolated acoustic tasks, such as sustained phonation and breathing. Overall, these results suggest that voice-based acoustic AI could complement existing diagnostic workflows by enabling rapid, low-burden, and widely accessible screening for airway stenosis.

0.43

SpiroPhonia: Non-Invasive Respiratory Health Assessment from Spontaneous Speech

cs.SD ·2026-09-15 ·Roksana Khanom, Shafia Supty, Nirupam Roy, Ashok Agrawala
top venuedatasethot direction similarity 0.66
Abstract · Accepted at Interspeech 2026, Sydney, Australia

Chronic Obstructive Pulmonary Disease (COPD) remains a major global health challenge, emphasizing the need for accessible and non-invasive detection. Since speech production is fundamentally linked to respiratory physiology, its disruptions can serve as indirect indicators of pulmonary impairment. This study introduces SpiroPhonia, a machine learning framework that leverages spontaneous speech for respiratory health assessment. We evaluated SpiroPhonia on a new dataset of 201 speakers (102 with COPD, 99 healthy controls). By integrating statistical analysis with recursive feature selection, we identified a compact set of discriminative speech markers. Our best model achieved 78% accuracy, 80% F1-score, and 87% AUC. This performance on spontaneous speech is competitive with methods using controlled laboratory recordings. Findings demonstrate that everyday speech encodes robust respiratory biomarkers, paving the way for continuous health monitoring via voice-enabled technologies.

0.65

Metadata-Conditioned Audio Transformers for Adaptive Respiratory Sound Classification

cs.SD cs.AIeess.AS ·2026-11-02 ·George Kontogiannis, Pantelis Tzamalis, Sotiris Nikoletseas
publishedbenchmark similarity 0.66
Abstract

Respiratory sound classification from auscultation recordings is confounded by heterogeneous acquisition conditions, including recording device, auscultation site, and patient characteristics, that introduce systematic variability unrelated to the underlying pathology. Although such metadata is often available, existing approaches either ignore it or rely on naïve fusion strategies that do not model how distinct metadata sources influence different components of the acoustic representation. We propose a family of metadata-conditioning mechanisms for the Audio Spectrogram Transformer (AST), progressing from gated residual fusion to Feature-wise Linear Modulation (FiLM) adapted to the Transformer architecture. We further introduce two novel variants: Token-Aware FiLM (TAFiLM), which applies distinct modulation to classification and patch tokens, and Soft-Factorized FiLM (SoftFiLM), which learns soft masks to align metadata factors with disentangled feature subspaces. Experiments on the ICBHI benchmark demonstrate consistent gains across all conditioning strategies. SoftFiLM achieves 64.11% on the official 4-class task (+3.94% over the baseline) and 72.40% on the 2-class task, establishing a new state-of-the-art on the 2-class task and competitive performance on the 4-class benchmark.

0.24

APRIL: Ambiguity-Aware Expert Routing for Respiratory Sound Domain-Incremental Learning

cs.SD cs.AI ·2026-10-20 ·Xinhong Li, Weiping Tu
similarity 0.64
Abstract

Automated respiratory sound classification enables continuous, non-invasive respiratory assessment, yet long-term deployment remains challenging due to domain shifts from evolving recording devices and acquisition periods. When privacy and governance regulations prohibit replaying historical data, sequential learning easily overwrites previously acquired knowledge. Preserving dedicated domain experts prevents parameter interference, but selecting the correct expert at inference is difficult under overlapping acoustic distributions and absent domain labels. To resolve this dilemma, we propose APRIL, an exemplar-free domain-incremental framework for RSC. Built on a shared frozen BEATs backbone, APRIL sequentially inherits and isolates low-rank experts to enable new-domain adaptation without altering earlier models. A multi-level prototype router retrieves the top-two candidate experts and dynamically selects the final model by integrating domain-routing posteriors with classification confidence, adaptively weighted by matching ambiguity. We establish standardized device- and temporal-incremental benchmarks on the ICBHI and SPRSound datasets across forward and reversed domain orders. Evaluated over five random seeds, APRIL consistently achieves the highest final-session average Score among compared continual learning approaches, reaching 64.4% and 65.4% on ICBHI, and 83.1% and 82.2% on SPRSound under forward and reversed sequences, respectively. Crucially, average forgetting remains under 1.0% across all protocols, demonstrating robust domain adaptation and long-term knowledge retention without data replay. Overall, APRIL offers a reliable and privacy-preserving paradigm for deploying continuous respiratory sound classification across real-world healthcare settings.

0.08

Breath-Dx: A Time Series Classification Benchmark for Disease Screening with eNose

cs.LG cs.AI ·2026-11-11 ·Ivan Poddiakov, Ivan Kruzhilov, Galina Zubkova, Svetlana Erofeeva, Andrey Savchenko +1 more
publishedbenchmarkdatasetcommunity pick similarity 0.64
Abstract · IEEE ICDM 2026 - Best Paper Runner-Up (Applied Track)

Electronic nose (eNose) technology offers a portable, non-invasive route for disease screening via exhaled breath analysis. However, progress in the field is hindered by the lack of systematic benchmarks that compare machine learning methods under realistic conditions, particularly sensor drift, a known but rarely quantified failure mode. Most existing studies rely on small, private datasets with inconsistent protocols, rendering results non-comparable and slowing progress. We introduce Breath-Dx, the first comprehensive benchmark of time series classification methods for breath-based disease screening. Our work leverages the Scent of Health (S-OH) dataset, the largest public clinical eNose collection to date, comprising 1,234 patients across nine diagnostic groups, each providing a 17-channel multivariate time series with explicit temporal train/test splits that account for sensor drift. We systematically evaluate 10 methods spanning four families: feature-based tabular learners, convolution-based models, graph-based, and time series architectures. All methods degrade significantly under temporal validation (0.05-0.12 AUC drop compared to random cross-validation), confirming that drift embeds a strong temporal signal. Under this realistic evaluation, the best methods achieve ROC AUC of 0.74-0.76 for some lung conditions, though others remain near chance. Recurrent architectures show the most consistent performance across diseases, while specialized time series methods achieve the highest peak results. Demographic confounders matter: breath signals provide independent diagnostic value for some conditions but add little beyond age for others. We release the S-OH dataset, all temporal splits, evaluation protocols, and code to enable reproducible research and accelerate progress in clinical breathomics.

0.43