CS Paper Radar

Listening for Airway Stenosis: A Foundation Model-Based Method for Rapid and Accessible Detection

Jean Groeninger, Zihao Zhao, Juliana de Castilhos, Sven Nebelung, Daniel Truhn

cs.SD ·submitted 2026-09-14 12:20 UTC · v1
code/data

Abstract

Airway stenosis can cause severe respiratory complications, yet its detection often relies on specialized examinations and medical imaging. This study explores the potential of acoustic AI for rapid and accessible airway stenosis detection using readily acquired patient voice recordings. We systematically investigate whether acoustic foundation models (AFMs) can extract acoustic representations associated with airway stenosis-related speech patterns. Experiments are conducted on a cohort of 748 participants from the Bridge2AI-Voice dataset, 134 with airway stenosis and 614 without. The best-performing model achieves an AUROC of 0.952 and an accuracy of 0.924 (means over five-fold cross-validation), highlighting the potential of AFMs to transfer beyond general-purpose speech applications to clinical diagnostic tasks. Further analysis reveals that the model primarily relies on connected-speech recordings rather than isolated acoustic tasks, such as sustained phonation and breathing. Overall, these results suggest that voice-based acoustic AI could complement existing diagnostic workflows by enabling rapid, low-burden, and widely accessible screening for airway stenosis.

Comment
Jean Groeninger and Zihao Zhao contributed equally. Code is available at https://github.com/JeanGrng/listening-for-airway-stenosis

Closest papers

Nearest neighbours by meaning across the whole index.

SpiroPhonia: Non-Invasive Respiratory Health Assessment from Spontaneous Speech

cs.SD ·2026-09-15 ·Roksana Khanom, Shafia Supty, Nirupam Roy, Ashok Agrawala
top venuedatasethot direction similarity 0.71
Abstract · Accepted at Interspeech 2026, Sydney, Australia

Chronic Obstructive Pulmonary Disease (COPD) remains a major global health challenge, emphasizing the need for accessible and non-invasive detection. Since speech production is fundamentally linked to respiratory physiology, its disruptions can serve as indirect indicators of pulmonary impairment. This study introduces SpiroPhonia, a machine learning framework that leverages spontaneous speech for respiratory health assessment. We evaluated SpiroPhonia on a new dataset of 201 speakers (102 with COPD, 99 healthy controls). By integrating statistical analysis with recursive feature selection, we identified a compact set of discriminative speech markers. Our best model achieved 78% accuracy, 80% F1-score, and 87% AUC. This performance on spontaneous speech is competitive with methods using controlled laboratory recordings. Findings demonstrate that everyday speech encodes robust respiratory biomarkers, paving the way for continuous health monitoring via voice-enabled technologies.

0.64

Design and Architecture of Airmod: An Active Noise Cancellation and Deep Learning System for Real-Time Respiratory Rate Estimation from Tracheal Sounds

cs.SD ·2026-10-27 ·Shang-Ran Huang, Fu-Shun Hsu, Ji-Chang Huang, Chuan Chen, Shou-Zen Fan +3 more
similarity 0.69
Abstract

Tracheal auscultation is recommended by clinical practice guidelines, and required by some U.S. state regulations, for monitoring ventilation during procedural sedation and monitored anesthesia care. However, continuous auscultation with a conventional stethoscope is impractical, susceptible to ambient noise, and difficult to interpret. We developed the Artificial Intelligence Respiratory MOnitoring Device (Airmod), an FDA-cleared software as a medical device (510(k) K242798) that continuously monitors tracheal sounds and estimates breath-to-breath respiratory rate in real time. In this paper, we describe its software architecture and key processing modules. Ambient noise is suppressed by active noise control, using a normalized least-mean-square adaptive filter with a dual-microphone electronic stethoscope. A multiclass convolutional bidirectional gated recurrent unit (CNN-BiGRU) model detects inhalations and exhalations in 15-s inference windows. It was trained on HF_Tracheal_V2, a new database of 373 continuous tracheal sound recordings (8,521 min; 107,644 labeled inhalations) from 369 subjects under sedation. To handle continuous acoustic streaming, Airmod runs inference on overlapping 15-s windows. It refines the detected inhalations by removing incomplete events, low-energy false positives, and double counts, concatenates them into a history list, and estimates respiratory rate from the mean period of the last three breaths. On the test set, at the default 2-s prediction interval with refinement enabled, inhalation detection achieved a sensitivity of 0.828, a positive predictive value of 0.832, and an F1-score of 0.830. Airmod also broadcasts the noise-cancelled tracheal sound and displays a real-time spectrogram to help clinicians recognize respiratory abnormalities.

0.21

Clinician Assessment of Laryngeal Disease with Auditory AI before Laryngoscopy: A Paired Reader Study

eess.AS cs.AI ·2026-11-15 ·Siyuan Hou, Shuting Yang, Zengrui Jin, Liyu Cheng, Siyin Wang +11 more
similarity 0.69
Abstract · 45 pages, including supplementary material

Background: Before laryngoscopy, clinicians assess the likely cause of hoarseness and whether to suspect a precancerous or malignant lesion. Whether voice-based artificial intelligence (AI) supports pre-laryngoscopic categorization is unknown. Methods: We developed an auditory large language model that generates a patient-level assessment card (provisional category, voice-quality ratings, and rationale) and a prespecified malignancy alert from voice recordings, patient information, and acoustic measures obtained before laryngoscopy at one center. We evaluated both in a held-out test set and a later cohort. In a sequential reader study, 32 otolaryngology clinicians categorized held-out cases without AI and, 1 to 2 weeks later, reviewed their initial categories with the card (without the alert). Results: Across 800 paired assessments, reader accuracy was 49.8% before and 56.8% after review (difference, 7.0 percentage points; 95% CI, 1.7 to 13.5; P < 0.001); 99 categories changed from incorrect to correct and 43 from correct to incorrect (ratio, 2.30; 95% CI, 1.22 to 5.31). Accuracy rose 14.7 points when the model was correct and fell 8.7 when incorrect. Provisional-category accuracy was 72% in held-out testing and 67% in temporal validation. The malignancy alert flagged 85.7% and 86.8% of precancerous or malignant lesions. Sensitivity for precancerous or malignant lesions increased from 53.9% to 75.0% after AI-assisted review (difference, 21.1 percentage points; 95% CI, 4.3 to 42.0). Conclusions: In this single-center study, clinicians' pre-laryngoscopic categorization accuracy was higher after reviewing the AI assessment card, although the sequential design cannot fully separate AI assistance from reassessment; gains depended on model correctness without clearly selective adoption. Randomized and external evaluations, including of the malignancy alert, are needed.

0.21

Feature Scaling Beats Architecture Choice in Offline Respiratory Screening for Low-Resource Clinics

cs.LG cs.AIcs.SD ·2026-10-12 ·Abubakar Chilala, Cleophas Kadima, Innocent Anyaele, Victor Olufemi
similarity 0.68
Abstract

Deep models are the usual choice for respiratory sound classification, but in clinics without GPUs or connectivity that choice carries a cost. We compare classical and deep classifiers on a five-class respiratory-sound corpus of 1,211 clips (asthma, COPD, pneumonia, Bronchial, healthy) from 201 patient groups, with a 3.86:1 class imbalance, using pre-registered patient-grouped cross-validation (25 runs per configuration). An SVM over 30 summary features (MFCC, ZCR and RMS statistics) reaches macro recall 0.78 and 0.71 recall on the rarest class. A 1.13M-parameter convolutional recurrent network over log-Mel spectrograms reaches 0.75 to 0.77, and no difference between model families is resolved. The largest single effect we measure is a preprocessing effect rather than an architectural one. Standardizing the SVM's features, a routine step for RBF kernels, moves its macro recall from 0.51 to 0.78, a 27-point swing wider than any gap between model families here. Augmentation did not help: SMOTE, waveform augmentation and SpecAugment have no measurable effect. Latency does not separate the models (51 to 74 ms per clip on a CPU-only laptop), but the classical models avoid a 449 MB PyTorch runtime. Clip-level splits, which let a patient's recordings fall on both sides, inflate macro recall by 7.5 to 9.8 points. Recording source is strongly tied to label (Cramer's V = 0.65 between native sampling rate and class), and in an exploratory analysis clips recorded at a class's minority rate are mostly assigned to classes typical of that rate; we state this confound as the paper's main limitation.

0.13

Clinically Informed Acoustic-Aware Attribute Modeling for Respiratory Sound Classification

cs.SD ·2026-10-16 ·Xinhong Li, Li Xiao, Ziyang Chen, Yuhong Yang, Weiping Tu
similarity 0.67
Abstract · Accecpted by BIBM2026 regular paper

Automated respiratory sound classification (RSC) aims to identify normal and adventitious respiratory sounds, such as crackles and wheezes. Most existing methods formulate RSC as a flat four-class classification problem over norma, crackle, wheeze and both. However, unlike conventional classification tasks with semantically independent and mutually exclusive categories, the commonly used four-class RSC labels have a compositional structure and can be represented by two clinically meaningful sound attributes: crackle presence and wheeze presence. Existing flat classifiers do not explicitly exploit this structure, which may increase the learning burden by treating the four labels as independent targets. Meanwhile, crackles and wheezes exhibit distinct temporal characteristics, with sparse transient crackle events and sustained continuous wheeze patterns, making a single temporal aggregation strategy less suitable for modeling different adventitious sound evidence. To address these limitations, we propose an Acoustic-Aware Asymmetric Framework (AAAF) for RSC. AAAF reformulates four-class recognition as two sound-attribute detection tasks and recovers the final category through logical composition during inference. Built upon a pretrained BEATs encoder, AAAF employs branch-specific multi-layer fusion and asymmetric temporal aggregation to capture localized crackle evidence and sustained wheeze patterns. Auxiliary normal--abnormal supervision and a batch-adaptive dynamic loss are further introduced to improve global discrimination and robustness under imbalanced labels. Experiments on ICBHI and SPRSound demonstrate that AAAF improves overall RSC performance and generalizes across datasets, achieving a state-of-the-art four-class Score of 65.30% on ICBHI.

0.24

Towards clinical adoption of voice and speech as measures of health: the need for harmonization

cs.ET cs.SD ·2026-09-24 ·Nicholas Cummins, Vikram Ramanarayanan, Daniel Low, Fabio Catania, Si-Ioi Ng +7 more
similarity 0.67
Abstract

Speech and voice are multidimensional signals that capture both communicative intent and underlying physiological processes, providing a unique, non-invasive window into health. Analyzing these signals has the potential to yield digital biomarkers that (i) provide scalable, objective measurement tools for research and clinical care and (ii) reflect the presence or progression of diverse conditions, including neurological, psychiatric, respiratory, and cardiovascular disorders. Realizing this promise, however, requires the field to overcome pervasive reproducibility and generalizability issues due to heterogeneous data collection, processing, and analysis practices. A major source of this heterogeneity is how underlying acoustic measures themselves are defined and computed. In this paper, we outline key considerations across the speech biomarker discovery lifecycle, from data collection through machine learning modeling to clinical interpretation, needed to achieve reliable, reproducible, and clinically translatable results. Chief among these is the need for harmonization efforts to start from common, precisely specified measure definitions. As a first step, we therefore provide definitions, physiological correlates, and computational implementations for a minimal, clinically interpretable set of core speech measures spanning respiration, phonation, articulation, and fluency. We close by discussing ongoing standardization efforts and the open challenges that remain in advancing the adoption of speech- and voice-based digital biomarkers.

0.08

BreathGRU: A Novel Semi-Supervised Bidirectional Gated Recurrent Unit Framework for Speech and Breath Segmentation for Respiratory Audio

cs.SD cs.LGeess.AS ·2026-09-25 ·Sania Fatima Sayed, John W. Holloway, Reyer Zwiggelaar, Faisal I. Rezwan
similarity 0.66
Abstract

Speech-breath segmentation is a fundamental preprocessing step in respiratory audio analysis, enabling applications such as respiratory acoustic biomarker extraction, lung function prediction and disease monitoring. Existing approaches, including threshold methods, Fourier Transform-based techniques, and unsupervised and pretrained voice activity detection (VAD) models, primarily focus on speech detection and often classify breathing events as non-speech or silence, limiting their applicability for precise breath detection. To address this limitation, we propose BreathGRU, a semi-supervised Bidirectional Gated Recurrent Unit (BiGRU) framework specifically designed for speech-breath segmentation. The proposed framework combines frame-level acoustic feature extraction with bidirectional recurrent modelling, pseudo-label refinement and duration-constrained Segmental Viterbi decoding to produce speech and breath segmentation. BreathGRU was evaluated against the existing approaches, using manually annotated recordings. Performance was assessed using event-based, time-based, overlap-based, duration-based and boundary-based segmentation metrics. Experiment results demonstrated that BreathGRU achieved the highest breath event recall (0.83), the lowest onset-localisation error (0.14s) and the highest Mean Match Intersection over Union (0.81), with competitive overall segmentation performance compared to large pretrained VAD models like Silero. Qualitative evaluation on manually annotated recordings further showed close agreement between BreathGRU and manual annotation, with better breath detection compared to Silero. These findings demonstrate that explicit breath event modelling provides advantages over general-purpose VAD models and establish BreathGRU as an effective speech-breath segmentation framework which can be applied for respiratory audio analysis and pulmonary healthcare applications.

0.29

RespFocus: Learning Temporal Evidence for Weakly Supervised Respiratory Sound Classification

cs.LG cs.AI ·2026-10-11 ·Yi Tian, Xiaohuan Chen, Yufei tang, Xinyu Lin, Hongliang Li +3 more
similarity 0.66
Abstract · 9 pages, 5 figures,2 tables

Respiratory auscultation provides a low-cost means of assessing pulmonary function, yet transient crackles and sustained wheezes can be difficult to recognize in noisy clinical recordings. Conventional deep learning classifiers often operate as black boxes, offering limited insight into the temporal acoustic evidence supporting their predictions. We present RespFocus, a weakly supervised framework that uses multiple instance learning (MIL) to learn inspectable temporal evidence from cycle-level labels and integrate it into classification. We also introduce PedResp2026, a multicenter pediatric respiratory sound cohort collected in routine clinical environments with adjudicated cycle-level annotations. In classification experiments, RespFocus achieves four-class Scores of 69.55\% on public ICBHI 2017 and 72.91\% on PedResp2026. Evidence diagnostics and matched temporal interventions support the functional contribution of the learned evidence to model predictions. Together, these findings highlight RespFocus's potential as a tool for automated respiratory sound diagnosis.

0.30